• Title/Summary/Keyword: 열감지기

Search Result 26, Processing Time 0.016 seconds

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings (국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.533-538
    • /
    • 2014
  • This study examines the performance of and searches for improvements to the existing automatic fire detection systems installed at domestic apartment buildings as a basic study for development of intelligent fire detection systems specifically for apartments. Thus, this study aims to find out the problems in performance and maintenance of the existing fire detectors installed at apartment buildings which is the prerequisite process for development of intelligent fire detection system for that specific application. It is also found impossible to check whether or not the detectors installed at each apartment are in an operational state at normal times. This study finds that it is desirable to replace the slow-sensing heat detectors by a smoke and single smoke detectors which can detect a fire at its early stage in an effort to improve the problems of fire detectors installed at apartment buildings presently. Because we need to the independence fire detection system of apartment building.

A Study on the Characteristics of an Optical Sensor Linear Fire Detection System with Miniature Model Fire Experiment (축소 모형실험을 통한 광센서 선형 화재 감지 시스템의 특성에 관한 연구)

  • Kim, Dong-Eun;Kim, Si-Kuk;Lee, Young-Sin;Lee, Chun-Ha;Lim, Woo-Sup
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.19-26
    • /
    • 2016
  • In this study, we conducted a low temperature operating test and miniature tunnel model test to study the fire detection capability and properties of an early fire detection system using an optical sensor linear detector that can be installed in harsh environments such as tunnel or utility-pipe conduits which are becoming the major and national infrastructure facilities. The test showed that the optical sensor linear detector was the only one functioned properly among five thermal detectors installed at a low temperature of $-20^{\circ}C$ for 5 days. To study were analyzed adaptability of optical sensor linear detector in the windy tunnel, the operating properties of the optical sensor linear detector when the wind velocity was varied between 0 m/s and 1 m/s in a miniature tunnel model. The temperature change was high when the wind velocity was 0 m/s.

A Study on Remote IoT operating time for Fire Detector of Smart Home (스마트 홈에서 연소에 따른 화재감지기 원격 IoT 작동 시간에 관한 연구)

  • Ko, Eun-young;Hong, Sung-Ho;Cha, Jae-sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.235-238
    • /
    • 2020
  • In the smart home era, fire safety is very important for human life and facility safety. Casualties and property damage from the fire would be a huge national loss. In this paper, we propose to predict the risk by determining the operating time of the fire detector according to the fire in the smart home. Among IoT fire detectors, heat detectors and smoke detectors, the risk can be predicted due to the difference in the operating time depending on the fire. Based on the results of this experiment, the ion-type smoke detector shows very fast characteristics, so it would be good to use the results in future fire prevention facility.

An Experimental Study on the Comparison of Operating Temperatures in Thermal Detector due to Tunnel Fire (터널 화재 시 열감지기 작동 온도의 비교에 관한 실험적 연구)

  • Roh, Hyeong-Ki;Park, Kwang-Young;Im, Seok-Been
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.23-27
    • /
    • 2011
  • Due to the rapid development of construction technology with effective land utilization in this nation, many tunnels were and are being built across the country. However, the smoke and the heat generated from tunnel fire are the most important critical factors which may results in both massive personal injury and property damage, especially, due to the closed surrounding of the tunnel. Considering this particular nature of the tunnels, this study aims to install a fire detection system using an optic fiber cable to measure the temperature changes, compare, and analyze the resulted values with the times of temperature changes of the sensor by performing fire simulations under the same condition as a real fire test. From the results, it has been found that the temperature sensor detects a fire occurrence and generates an alarm within one minute after ignition for both a real fire test and a fire simulation alike, and also that the characteristics of temperature changes of the sensor has close relations with the speeds of the currents inside the tunnel. In addition, considering the tunnel fires can affect the evacuation efficiency and the fire extinguishing activities of the fire brigade inside the tunnel, the temperature sensor must be able to search and find the locations and directions of the fires correctly.

Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling (화재모델링 예측성능 개선을 위한 이온화식 연기감지기의 장치물성 측정)

  • Kim, Kyung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2013
  • The high prediction performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of PBD (Performance Based fire safety Design). The main objective of the present study is to measure input information in order to predict the accurate activation time of smoke detector into a Large Eddy Simulation (LES) fire model such as FDS (Fire Dynamics Simulator). To end this, FDE (Fire Detector Evaluator) which can measure the device properties of detector was developed, and the input information of Heskestad and Cleary's models was measured for a ionization smoke detector. In addition, the activation times of smoke detectors predicted using default values into FDS and measured values in the present study were systematically compared. As a result, the device properties of smoke detector examined in the present study showed a significant difference compared to the default values used into FDS, which resulted in the considerable difference of up to 15 minutes or more in terms of the activation time of smoke detector. The database (DB) on device properties of various smoke and heat detectors will be built to improve the reliability of PBD in future studies.