• Title/Summary/Keyword: 연제진

Search Result 9, Processing Time 0.029 seconds

회원작품

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.2 s.84
    • /
    • pp.33-49
    • /
    • 1976
  • PDF

Single Axis Vibration Isolation System Using Series Active-passive Approach (직렬형 능-수동 제진 방법을 이용한 1축 제진 시스템)

  • Banik, Rahul;Lee, Dong-Yeon;Gweon, Dae-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.176-179
    • /
    • 2005
  • To control the vibration transmitted to the precision instruments from ground has always been of great interest among the researchers. This paper proposes a single axis vibration isolation system which can be used as a module far a table top six axis isolator for highly precise measurement and actuation system. The combined active-passive isolation principle is used for vertical vibration isolation by mounting the instrument on a passively damped isolation system made of Elastomer along with the active stage in series which consists of very stiff piezo actuator. The active stage works in combination with the passive stage for working as a very low frequency vibration attenuator. The active stage is isolated from the payload disturbance through the Passive stage and thus modularity in control is achieved. This made the control algorithm much easier as it does not need to be tuned to specific payload.

  • PDF

Grounding method for Improving of the Characteristics on Cable TV Transmission Line (케이블 TV 전송선로의 특성 개선을 위한 접지방식)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Yeon, Che-Chin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF

A study on the Grounding method for reduce an interference by CATV Transmission Line (CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구)

  • Hwang, Jong-Sun;Yon, Che-Chin;Park, Sung-Jin;Kim, Yeong-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

A study on the Grounding method for reduce an interference by CATV Transmission Line (CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구)

  • 황종선;연제진;박성진;김영민
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

A Study on the Long term Properties of Epoxy Resin (에폭시 제진의 장기적인 특성연구)

  • 한만엽;송병표;이원창;연규석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.89-94
    • /
    • 1997
  • As the reinforced concrete structures are aged, repair and rehabilitation materials and techniques have ben developed. However, most of the repair materials and methods are imported from abroad and theoretical study and repairing techniques are also not well established yet. A specification for quality of repair materials should be established, in order to secure the stability and to improve the serviceability of the repaired structures. In this study, long term properties of repair materials such as thermal expansion coefficient, hardening shrinkage, creep, and chemical resistance have been tested. The material properties shows to be affected many actors such as curing period, temperatures, relative humidity, and etc. The repair material should be selected by considering the cause and shape of the defects, mix properties, workability, quality control of construction, and etc.

  • PDF

The Usefulness of Fluorescein Angiography and Alternative Tests for Assessment of Fundus Hemorrhage (안저 출혈 시 형광안저혈관조영술 및 대체 검사의 유용성)

  • Yeon, Je-Jin;Koo, Bon-Kyeong;Park, Sang-Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.266-276
    • /
    • 2021
  • Fundus hemorrhage refers to abnormalities in the retinal tissue and blood vessels. Therefore, when a hemorrhagic change in the fundus occurs, the ophthalmologist orders various ophthalmic tests to evaluate the degree of hemorrhage and determine the progress of the lesion before, during, and after treatment to accordingly establish a treatment plan. Currently, the most useful and universal fundus examination includes optical coherence tomography (OCT), fundus photography (FP), and fluorescein angiography (FAG). Existing fluorescein angiography test methods for establishing a treatment plan for severe fundus bleeding have limitations. The authors propose that peripheral pupil and the 5-quadrant method should be performed using ultra-wide-angle fluorescence fundus angiography (UWFFA). Using this method, it is possible to quickly determine the area to be described, avoid the radius of bleeding as much as possible, and provide the ophthalmologist with a range of damaged tissue and abnormal blood vessels. Nevertheless, there are cases in which ophthalmologists judge that fundus bleeding is so severe that ultra-wide-angle fluorescence fundus angiography is meaningless. In such cases, ophthalmic ultrasound and electroretinogram may be used in that order as alternative methods of examination. Therefore, some clinical situations require the use of ophthalmic ultrasound and electroretinogram and should be performed accurately.