• Title/Summary/Keyword: 연속운전

Search Result 480, Processing Time 0.028 seconds

원전 비상운전의 State Orientated Approach

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.6 no.12 s.46
    • /
    • pp.107-110
    • /
    • 1986
  • 프랑스전력청(EdF)은 원자력발전소에서 적용되고 있는 비상시 운전절차를 변경중이다. 현행의 사상지향식 방법(Event-Orientated Approach)과는 대조적으로 새로운 방법은 플랜트의 기본적인 물리적인 특성(여기서는 '플랜트상태'라고 지칭한다)의 변동을 연속적으로 모니터하고 플랜트상태만을 기준하여 교정조치를 취하는 것을 기본으로 한다.

  • PDF

Permeation Behavior of Microfiltration Membrane by Alumina Colloidal Suspension under a Cyclic Variation in TMP (운전압력의 순환변화에 따른 알루미나 현탁액의 정밀여과 투과거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.13-21
    • /
    • 2011
  • This study investigated the fouling behavior of $Al_2O_3$ colloids on polyethylene microfiltration membrane. To examine the effect of operation variation on fouling, operating pressure was increased from 0.49 to 1.96 bar along with time elapses and then was reduced to 0.49 bar reversely. A hysteresis behavior was observed in the membrane permeate flux over pressure, revealing different fluxes at the same pressure according to the pressure control type, increasing and decreasing. Permeate resistance and its rate of increase was higher in the decreasing pressure cycle than in the increasing pressure cycle. At the initial period of filtration, fouling mechanism for the both cycles was governed by the cake filtration. The degree of fouling was higher in the decreasing pressure cycle compared with in the increasing pressure cycle.

The Transition Control Technique between Sinusoidal-Wave and Square-Wave Driving Method in Inverter for PMSM (영구자석형 동기전동기용 인버터에서 정현파-구형파 운전 방식 사이의 전환 방법)

  • Lee, Seung-Yong;Yoon, Duck-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.113-114
    • /
    • 2016
  • 영구자석형 동기전동기를 구동하는 인버터에서는 기본적으로 정현파 운전 방식을 사용하지만 최근에는 구형파 운전 방식도 종종 사용되고 있다. 정현파 운전 방식은 구형파 운전 방식에 비해 토크 리플이 작고 기동 성능이 우수하며, 약자속 제어를 이용하여 정격 속도 이상의 고속 운전이 가능하다. 이에 비해 구형파 운전 방식은 제어 알고리즘이 간단하고 스위칭 손실이 적은 장점이 있지만, 토크 리플이 크고 정격 속도 이하의 영역에서만 운전이 가능하다는 단점이 있다. 최근에 인버터의 운전 중에 각각의 장점이 있는 이들 2가지 운전 방식을 서로 전환하는 방법으로 가전제품의 압축기와 같은 연속 부하에 적용하기 위한 연구가 진행되었다. 저속 구간에서는 스위칭 손실을 줄이기 위하여 구형파 운전 방식을 주로 사용하고, 고속 구간에서는 안정적인 제어 성능을 위하여 정현파 운전 방식을 사용한다. 또한, 이 2가지 운전 방식의 전환 구간에서의 발생되는 과도 상태를 짧게 줄이기 위하여 속도 및 전류 제어기의 제어 변수에 대한 초기화 방법이 제시되었다. 본 논문에서는 구형파 운전 구간의 속도 제어기에 비례 적분 전류 제어기를 추가하여 전류 리플을 감소시키고, 전환 구간에서의 속도 및 전류 제어기의 제어 변수에 대한 초기화 방법을 제시하였다.

  • PDF

역삼투막설비의 전처리를 위한 연속식 정밀여과기의 공정최적화

  • 임성린;김형진
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2002.05b
    • /
    • pp.271-272
    • /
    • 2002
  • 하수 또는 폐수의 재이용시 사용되는 역삼투막설비의 전처리공정으로 사용되는 연속식정밀여과기의 전단에 PAC와 같은 응집제를 10ppm 투입하고 역세주기를 20분으로 하여 막오염을 최소화함으로써 재이용 시스템의 안정적인 운전이 가능하였다.

  • PDF

선박의 윤활

  • 김주환
    • Tribology and Lubricants
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 1992
  • 발전기용 원동기에는 증기 Turbine engine과 디이젤 Engine으로 분류한다. 일반적으로 발전기 Bearing의 윤활유는 구동용(驅動用) 원동기와 동일한 윤활유를 사용하고 있다. 또한 디이젤 발전기는 연료가 A중유로서 비교적 양질의 연료유를 사용하고 있다고 하더라도 고부하로서 연속운전되고 있기 때문에, 윤활조건이 가혹하게 되어지고 있다. 따라서 항상 사용유의 상태를 파악할 필요가 있다.

An Implementation of Expert System for Continuous Ship Unloader (연속식 언로더용 전문가 시스템 구현)

  • 서정만;임채근;김정윤
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10b
    • /
    • pp.490-492
    • /
    • 1998
  • 환경문제를 전혀 야기하지 않으며 하역능률이 뛰어난 차세대 하역설비인 연속식 Unloarder의 하역능률을 관리하고 운전 및 정비의 효율적인 운영을 보장하는 초저가형 Expert System인 SCIS-30과 그 구현에 대하여 소개하고자 한다

Performance Evaluation of the Field Scale Sequential Washing Process for the Remediation of Arsenic-Contaminated Soils (Field 규모 연속 토양세척공정을 이용한 비소 오염토양 정화 효율 평가)

  • Choi Sang Il;Kim Kang Hong;Han Sang-Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.68-74
    • /
    • 2005
  • This study was carried out to evaluate the feasibility of field-scale sequential soil washing process for remediation on Kyongsangnamdo D mine soils which was heavily contaminated by arsonic. Arsenic concentration of untreated soils was $321\pm32mg/kg$. By applying the basic operating condition which was proposed from several pilot-scale experiments, arsenic concentration of treated soils was reduced 2.04 mg/kg ($99\%$ removal efficiency). We optimized the basic operating condition (mainly on washing solution concentration, cut-off size, and mixing ratio) to improve efficiently and economically the field-scale sequential soil washing process. The resulting optimized conditions were that solution concentration is 0.2M HCl, 1.0M HCl, 1.0M NaOH, that the cut-off size is 0.15mm (seive $\sharp$100), and that the mixing ratio is 1 3. Also, the optimized pH value for soil washing effluent treatment was 6 (33 ppb), in which the precipitation disruption caused by supersaturation of the floe did not occur. Results of TCLP tests showed that arsenic concentration from the washed gravels was 1.043 mg/L, that from soils ND (not detected), and that from filter cakes 0.066 mg/L. Also, the water content as a percentage of dewatered sludges was low $(48\%)$ and so the dewatered sludges can be disposed by landfilling. Through these results, we can concluded that tile field-scale sequential soil washing process developed in this study is adopted for remediation of arsenic-contaminated soils.

Field application on biological treatment process for removing 1,4-dioxane (1,4-dioxane 제거를 위한 생물학적 처리공정의 현장 적용성 검토)

  • Park, Doori;Lee, Kanghun;Jun, Moonhwee;Yeom, Icktae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.283-283
    • /
    • 2015
  • 1,4-dioxane은 페인트, 광택제 및 코팅제의 제조시에 첨가되는 화학물질로 인간에 대한 발암 가능성과 수중에서의 지속성으로 인해 EPA priority pollutant로 지정되어 있다. 이에 최근 고도산화법을 이용한 처리가 계속적으로 연구되고 있으며, UV/$H_2O_2$ 공법을 통하여 수계에서 발견되는 난분해성 유기 오염물의 제거가 효과적인 것으로 밝혀졌다. 하지만 고도산화공정(AOP)은 다량의 에너지 소모와 산화제 투여로 인한 높은 운전비용이 현실적인 적용에 장애가 되고 있다. 한편 상대적으로 저렴한 비용으로 1,4-dioxane을 처리할 수 있다는 장점으로 인하여 생물학적 분해에 대한 많은 연구가 진행되어 왔다. 하지만, 1,4-dioxane에 대한 많은 연구들이 주로 분해미생물의 분리동정 및 회분식 분해특성에 대한 연구들 위주로 보다 실질적인 연속적 처리반응조의 운전결과들은 거의보고 되지 않고 있다. 본 연구는 Lab scale 연속처리반응조의 장기운전 후 pilot plant 현장적용에 앞서 인공폐수와 합성폐수에서의 분해효율 비교 회분식 실험을 통해 합성폐수내 생물학적 분해에 영향을 미치는 inhibitor의 영향을 확인하였으며, 미생물의 배양 조건에 따른 분해효율 비교 회분식 실험과 modeling을 통하여 현장운영 효율을 예측하였다. 이를 반영하여 추후 진행예정인 pilot plant의 현장 적용성 검토 및 최적 설계인자 도출, 장기운전에서의 효율성 증대를 목적으로 한다.

  • PDF

Design and Test of Slag Tap Burner System for Prevention of Molten Slag Solidification in Coal Gasifier (석탄가스화기 용융슬랙의 고형화 방지를 위한 슬랙탭 버너시스템 설계 및 시험)

  • Chung, Seokwoo;Jung, Kijin;Lee, Sunki;Byun, Yongsu;Ra, Howon;Choi, Youngchan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.74.2-74.2
    • /
    • 2011
  • 석탄가스화 기술은 고온, 고압 조건에서 석탄과 산소의 불완전연소 및 가스화 반응을 통해 일산화탄소(CO)와 수소($H_2$)가 주성분인 합성가스를 제조하여 이용하는 현실적인 에너지원의 확보를 위한 방법인 동시에 이산화탄소를 저감할 수 있는 기술이다. 석탄가스화기 공급되는 석탄은 산소와의 부분 산화, 수증기 및 $CO_2$와의 반응에 의하여 합성가스로 전환되는데, 일반적으로 슬래깅 방식 석탄가스화기의 정상운전 중에 가스화기 내부 온도는 $1,400{\sim}1,600^{\circ}C$ 정도의 고온이며, 운전압력은 20~60 기압으로 매우 고압 상태에서 운전이 이루어지는데, 공급되는 석탄 시료의 성분들 중 가연성 물질의 99% 이상이 합성가스로 전환되는 반면, 회분에 해당되는 무기물의 대부분은 용융 슬랙 형태로 가스화기의 벽을 타고 흘러내리다가 슬랙탭을 통해 하부의 냉각조로 떨어지면서 급냉이 이루어지게 된다. 그러므로, 석탄가스화기 정상운전중 슬랙탭 주변의 온도를 고온으로 유지함으로써 용융슬랙의 고형화를 방지하는 것은 석탄가스화기의 안정적인 연속운전을 위하여 중요한 기술 중의 하나라고 할 수 있다. 따라서, 본 연구에서는 저급탄 가스화를 위한 1 톤/일급 고온, 고압 습식 석탄가스화기의 정상운전중 슬랙탭 부근에서 용융슬랙의 고형화를 방지하기 위한 슬랙탭 버너시스템의 설계를 진행하였으며, 안정적인 운전조건 도출을 위하여 보조연료(CNG)와 산소의 공급비율에 따른 화염특성 시험을 진행하였다.

  • PDF

Evaluation of Operating Factors for the Continuous CO2 Fixation with a Photobioreactor (폐탄산가스 고정화를 위한 연속식 광반응기의 운전 인자 평가)

  • Shin, Hang-Sik;Chae, So-Ryong;Jang, Min-Young;Park, Bong-Sun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.71-76
    • /
    • 2000
  • The biological carbon dioxide fixation using microalgae has been known as an effective carbon dioxide reduction technology. With many environmental factors influencing microalgal productivity, the desirable cultivation factors were investigated using a green alga, Euglena gracilis. It has the high protein and vitamin E to be used as fodder. In batch culture with a photobioreactor, initial pH, temperature, carbon dioxide concentration and light intensity in the optimum cultivation condition were 3.5, $27^{\circ}C$,5-10% and $520{\mu}mol/m^2/s$, respectively. After that, the optimum hydraulic retention time (HRT for the continuous cultivation was 4 days at carbon dioxide concentration of 10%. In this condition, the final dry cell weight was 1.2g/l.

  • PDF