• Title/Summary/Keyword: 연소 실험

Search Result 1,890, Processing Time 0.037 seconds

Environmental Pollution in Korea and Its Control (우리나라의 환경오염 현황과 그 대책)

  • 윤명조
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.5-6
    • /
    • 1972
  • Noise and air pollution, which accompany the development of industry and the increase of population, contribute to the deterioration of urban environment. The air pollution level of Seoul has gradually increased and the city residents are suffering from a high pollution of noise. If no measures were taken against pollution, the amount of emission of pollutant into air would be 36.7 thousand tons per year per square kilometer in 1975, three times more than that of 1970, and it would be the same level as that of United States in 1968. The main sources of air pollution in Seoul are the exhaust has from vehicles and the combustion of bunker-C oil for heating purpose. Thus, it is urgent that an exhaust gas cleaner should be instaled to every car and the fuel substituted by less sulfur-contained-oil to prevent the pollution. Transportation noise (vehicular noise and train noise) is the main component of urban noise problem. The average noise level in downtown area is about 75㏈ with maximum of 85㏈ and the vehicular homing was checked 100㏈ up and down. Therefore, the reduction of the number of bus-stop the strict regulation of homing in downtown area and a better maintenance of car should be an effective measures against noise pollution in urban areas. Within the distance of 200 metres from railroad, the train noise exceeds the limit specified by the pollution control law in Korea. Especially, the level of noise and steam-whistle of train as measured by the ISO evaluation can adversely affect the community activities of residents. To prevent environmental destruction, many developed countries have taken more positive action against worsening pollution and such an action is now urgently required in this country.

  • PDF

Experimental Study on the Characteristics of Combustion in the Indirect Moxibustion with Ginger (격강구(隔薑灸)의 연소(燃燒) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Geon-hui;Moon, Sung-jae;Hwang, Byung-chun;Guk, Uo-suk;Jang, Ji-yeon;Kim, Yang-jung;Jang, Jae-ho;Yun, Ju-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.193-214
    • /
    • 2004
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion with ginger objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with ginger. Methods : We have selected the indirect moxibustion with ginger among many indirect moxibustions. We produced a slice of ginger to a thickness of 3, 4, 5mm and the moxa cone having a diameter of 8mm, a height of 10mm for making a comparative study of characteristics of moxa cone according to change the density. We have made a comparative study of the thermodynamic characteristics of moxibustion with ginger with or without holes. We measured combustion times and calculated temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. We found out it was not significantly influenced by the existence of the punched holes in a slice of ginger because the punched holes grow smaller immediately. 2. The duration of the preheating period became longer according to thickness of a slice of ginger and was not directly proportional to the density of moxa cone. The duration of the preheating period was extremely short when it burned a 100mg moxa cone. That was influenced by the density of moxa cone. 3. The duration of the heating period became longer according to thickness of a slice of ginger likewise the preheating period bacause the density of moxa cone had effected on the combustion characteristics. The duration of the heating period was extremely long when it burned a 100mg moxa cone. On the other hand the maximum temperature in the heating period was appeared that the combustion with a thin slice of ginger was highest and measured that the large density of moxa cone was higher. But the maximum temperature in the heating period was about $37.8^{\circ}C{\sim}44.2^{\circ}C$respectively lower in others. 4. The duration of the retaining period was some doubling shorter than that of the heating period that is concerned the shape of moxa cone. The temperature measured the close of a retaining period was $36.6^{\circ}C{\sim}41.8^{\circ}C$, that was considerably lower temperature. 5. The mean ascending temperature velocity and the mean descending temperature velocity were $0.042{\sim}0.073^{\circ}C/sec$, $-0.027{\sim}-0.064^{\circ}C/sec$ respectively. Then, the ascending temperature velocity was some faster than the ascending temperature velocity. Conclusions : The quantitative standard for obtaining the effective heating stimulation is that if the slice of ginger made a hole in it, we had to use the needle above 1.5mm diameter. The recommended size of a slice ginger is the 14mm diameter and the 2~3mm thickness. The moxa cone is formed the conical shape that the base diameter was 8mm, the height was 10mm, the density was $600mg/cm^2$.

  • PDF

Conceptual Design and Hydrodynamic Properties of a Moving Bed Reactor for Intrinsic $CO_2$ Separation Hydrogen Production Process ($CO_2$ 원천분리 수소 제조 공정을 위한 이동층 반응기의 개념 설계 및 수력학적 특성)

  • Park, Dong-Kyoo;Cho, Won-Chul;Seo, Myung-Won;Go, Kang-Seok;Kim, Sang-Done;Kang, Kyoung-Soo;Park, Chu-Sik
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.69-77
    • /
    • 2011
  • The intrinsic $CO_2$ separation and hydrogen production system is a novel concept using oxidation and reduction reactions of oxygen carrier for both $CO_2$ capture and high purity hydrogen production. The process consists of a fuel reactor (FR), a steam reactor (SR) and an air reactor (AR). The natural gas ($CH_4$) is oxidized to $CO_2$ and steam by the oxygen carrier in FR, whereas the steam is reduced to hydrogen by oxidation of the reduced oxygen carrier in SR. The oxygen carrier is fully oxidized by air in AR. In the present study, the chemical looping moving bed reactor having 200 L/h hydrogen production capacity is designed and the hydrodynamic properties were determined. Compared with other reactors, two moving bed reactors (FR, SR) were used to obtain high conversion and selectivity of the oxygen carrier. The desirable solid circulation rates are calculated to be in the range of $20{\sim}100kg/m^2s$ from the conceptual design. The solid circulation rate can be controlled by aeration in a loop-seal. To maintain the gas velocity in the moving beds (FR, SR) at the minimum fluidization velocity is found to be suitable for the stable operation. The solid holdup in moving beds decrease with increasing gas velocity and solid circulation rate.

Removal of Alkali Metal Ion using Inorganic Ion Exchanger (무기이온교환제를 이용한 알카리 금속이온 제거)

  • Ha, Ji-Won;Yi, Kwang Bok;Lee, Si Hyun;Rhee, Young-Woo;Kim, Jong-Nam
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.423-429
    • /
    • 2008
  • Currently, Ash-free clean coal producing process by solvent extraction is under development. The produced ash-free clean coal can be directly combusted in a gas turbine which results in substantial improvement of power generation efficiency. However, the clean coal produced by the solvent extraction still contain trace amount of alkali metal which may cause corrosion on turbine blades during the direct combustion. In present work ${\alpha},{\beta}$-metal (Zr and Ti) phosphates and H-Y zeolite were synthesized and their ion exchange characterizations were investigated for the application on alkali metal removal for clean coal production. $Na^+$ ion removal capacities of the metal phosphates and H-Y zeolite were measured and compared in both aqueous solution (100 ppmw, $Na^+$) and coal dissolved N-methyl-2-pyrrolidone (NMP, 12 ppmw $Na^+$) at elevated temperature. In aqueous solution, the ${\beta}$ form metal phosphates showed very high ion exchange capacities compared to ${\alpha}$ form. ${\beta}$ form metal phosphates also showed higher $Na^+$ removal capacities than H-Y zeolite. In ion exchange medium of NMP, all the ${\alpha}$ form metal phosphates showed over 90% of $Na^+$ ion removal efficiency in the temperature range of 200 to 400 while that of H-Y zeolite decreased as a half when the temperature was over 350. In addition, the regenerated metal phosphates by acid treatment showed no sign of degradation in $Na^+$ removal efficiency. Among the metal phosphates used, $Zr_{0.75}Ti_{0.25}(HPO_4)_2$ showed the best performance in $Na^+$ removal and is expected to be the most suitable inorganic ion exchanger for the alkali metal removal process.

Effect of Added NH$_3$ to AMP on Absorption Rate for Simultaneous Removal of CO$_2$/NO$_2$ in Composite Absorption Process (복합흡수공정에서 CO$_2$/NO$_2$ 동시제거 시 AMP(2-amino-2-methyl-1-propanol)에 Ammonia 첨가가 흡수속도에 미치는 영향)

  • Seo, Jong-Beom;Choi, Won-Joon;Moon, Seung-Jae;Lee, Gou-Hong;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1287-1293
    • /
    • 2008
  • In this study, a blend of 2-amino-2-methyl-1-propanol (AMP) and ammonia (NH$_3$) was used to achieve high absorption rates for carbon dioxide (CO$_2$) as suggested at several literatures. The absorption rates of aqueous AMP and blended AMP+NH$_3$ solutions with CO$_2$ and nitrogen dioxide (NO$_2$) were measured using a stirred-cell reactor at 303 K. The effect of the added NH$_3$ to enhance absorption characteristics of AMP was studied. The performances were evaluated under various operating conditions. The absorption rates increased following the increase of the concentration of NH$_3$. The absorption rate of NH$_3$ blended into 30 wt.% AMP solution with NO$_2$ at 303 K was 12.6$\sim$32.6% higher than that of aqueous AMP solution without NH3. Also, the addition of 3 wt.% NH$_3$ to 30 wt.% AMP increased 48.2$\sim$41.6% values for the reactions with CO$_2$ and NO$_2$ at 303 K. Therefore, it clearly shows that the reaction rate of AMP with CO$_2$ and NO$_2$ can be increased by the addition of NH$_3$.

A Comprehensive Study on the Forced Aging of Flue-cured Tobacco-Leaves (황색종 잎담배의 발효숙성 촉진에 관한 종합적 연구)

  • Bae, H.W.
    • Applied Biological Chemistry
    • /
    • v.13 no.1
    • /
    • pp.1-27
    • /
    • 1970
  • The process of the forced aging of flue-cured tobacco leaves were studied extensively from various scientific points of view. The Flue-cured tobacco leaves were inoculated and fermented with nicotine resistant Hansenula yeast, or the leaves were subjected under simple forced aging. The above two processes of forced aging were studied from the summarized points of microbiology, physics, chemistry, and biochemistry, and the resulted products ware compared in their physical, chemical and biochemical quality determining factors with that of raw material tobacco leaves (dried-tobacco leaves) and 2 years aged high quality tobacco leaves. The summary results were as follows. 1) The Korean flue-cured tobacco leaves, were forcedly aged under the basic optimum aging condition, temperature $40^{\circ}C$, moisture contents 18%, relative humidity 74%. It was found that this aging condition was the best in bringing the quality of forcedly aged tobacco leaves to the utmost state. 2) Under this optimum temperature and moisture condition of forced aging in about 20 days the forcedly aged tobacco leaves both with yeast inoculation and without yeast inoculation showed the equivalent tobacco qualities comparable with that of more than 2 years aged tobacco leaves. 3) The forcedly aged tobacco leaves both with and without yeast inoculation under $40^{\circ}C$ temperature and $74^{\circ}C$ relative humidity achieved the necessary quality determining physical and chemical changes in about 20 days. 4) The microbial changes during the forced aging were as follows. The population of yeasts and bacteria increased until to 15 days of aging, then decreased thereafter. Whereas the molds grew continously until the end of fermentation. 5) The tobacco quality determing physico-chemico-properties of yeast inoculated aged and simple forcedly aged tobacco leaves, progressed as the follows in time. As the forced aging progresses, swelling and combustibility properties were improved. The pH, total reducing materials, total sugars, alkaloids contents decreased. The contents of organic and ether extractable materials increased. The total nitrogen, protein, crude fiber, ash contents showed no changes. The color properties, excitation purity, luminance, main wave length, showed equivalent changes comparable with that of 2 years aged tobacco leaves. 6) The changes in chemical components in yeast treated and simple forcedly aged tobacco leaves during $15{\sim}20{\;}days$ of forced aging were as follows. The following chemical components decreased as the aging. Sugars-sucrose. rhamnose, glucose. Pigments-chlorophyll, carotenes, xanthophyll and violax anthine. Polyphenols-rutin, chlorogenic and, coffeic acid. Organic acids-iso-butylic, crotonic, caprylic, galacturonic, tartaric, succinic, citric acid. Alkaloids-nicotine, nornicotine. The following components increased as the forced aging progressed. Sugars-frutose, maltose, raffinose. Amino acids-proline, cystine. Organic acids-formic, acetic, propionic, n-butyric, iso-valeric, n-valeric, malic, oxalic, malonic, ${\alpha}-ketoglutaric$, fumaric, glutaric acid. 7) During the forced aging of tobacco Leaves the oxygen-uptake decreased gradually. The enzyme activities of polyphenol oxidase, ${\beta}-amylase$ ${\alpha}-amylase$ decreased gradually. The activities of the enzymes, catalase, and invertase increased once then decreased at the later stage.

  • PDF

Thermal Property and Fire Resistance of Cellulose Insulation (섬유질 단열재의 열적 특성 및 내화성능)

  • Kwon, Young-Cheol;Seo, Seong Yeon;Kim, Sung Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.203-212
    • /
    • 2005
  • Cellulose insulation is primarily manufactured from recycled newsprint and treated with fire retardants for the fire resistance. Thanks to the fire retardants, it is not combustible and flammable. In addition to that, Its thermal resistance is much better than that of fiberglass or rock wool. It is made from waste paper and easily decayed when it is demolished, and it has small embodied energy. So it is very environment-friendly building material. For broader use of cellulose insulation in buildings in Korea, it is necessary to test its physical performance to compare the results with the requirements on the Korean Building Code. To this end, apparent thermal conductivity (ka) measurements of Korean-made loose-fill cellulose insulations were recently completed using equipment that was built and operated in accordance with ASTM C 518 and the fire resistance was tested in accordance with ASTM C 1485. Korean loose-fill cellulose has thermal conductivity about 5% greater than the corresponding U.S. product at the same density. This is likely due to differences in the recycled material being used. Both spray-applied and loose-fill cellulose insulation lose about 1.5% of their thermal resistivity for $5.5^{\circ}C$ increase in temperature. The fire resistance of cellulose insulation is increased in linear proportion to the increase of the rate of fire retardant. Thanks to the high fire resistance, cellulose insulation can be used as a substitution of Styrofoam or Urethane foam which is combustible. The thermal conductivity of cellulose insulation was $0.037-0.043W/m{\cdot}K$ at the mean specimen temperature from $4-43^{\circ}C$. It corresponds to the thermal resistance of "Na Grade" according to the Korean Building Code. The effect of chemical content on thermal conductivity was negligible for all but the chemical-free specimen which had the highest value for the thermal conductivity over the temperature range tested. The thermal resistance of cellulose insulation is better than that of fiberglass or rock wool, and its fire resistance is higher than that of Styrofoam or Urethane foam. Therefore it can be substituted for those above considering its physical performance. Cellulose insulation is no more expensive than Styrofoam or rock wool, so it is recommended to use it more widely in Korea.

Methodological Comparison of the Quantification of Total Carbon and Organic Carbon in Marine Sediment (해양 퇴적물내 총탄소 및 유기탄소의 분석기법 고찰)

  • Kim, Kyeong-Hong;Son, Seung-Kyu;Son, Ju-Won;Ju, Se-Jong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.235-242
    • /
    • 2006
  • The precise estimation of total and organic carbon contents in sediments is fundamental to understand the benthic environment. To test the precision and accuracy of CHN analyzer and the procedure to quantify total and organic carbon contents(using in-situ acidification with sulfurous acid($H_2SO_3$)) in the sediment, the reference material s such as Acetanilide($C_8H_9NO$), Sulfanilammide($C_6H_8N_2O_2S$), and BCSS-1(standard estuary sediment) were used. The results indicate that CHN analyzer to quantify carbon and nitrogen content has high precision(percent error=3.29%) and accuracy(relative standard deviation=1.26%). Additionally, we conducted the instrumental comparison of carbon values analyzed using CHN analyzer and Coulometeric Carbon Analyzer. Total carbon contents measured from two different instruments were highly correlated($R^2=0.9993$, n=84, p<0.0001) with a linear relationship and show no significant differences(paired t-test, p=0.0003). The organic carbon contents from two instruments also showed the similar results with a significant linear relationship($R^2=0.8867$, n=84, p<0.0001) and no significant differences(paired t-test, p<0.0001). Although it is possible to overestimate organic carbon contents for some sediment types having high inorganic carbon contents(such as calcareous ooze) due to procedural and analytical errors, analysis of organic carbon contents in sediments using CHN Analyzer and current procedures seems to provide the best estimates. Therefore, we recommend that this method can be applied to measure the carbon content in normal any sediment samples and are considered to be one of the best procedure far routine analysis of total and organic carbon.

  • PDF

Changes in Sink capacity and Source Activity of Rice Cultivars in Response to Shift of Heading date (벼 품종들의 출수기에 따른 동화산물 생산능력 및 수용기관 크기 변화)

  • Lee, Sok-Young;Kwon, Yong-Woong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.2
    • /
    • pp.260-267
    • /
    • 1995
  • In temperate zone planting rice at different date subjects the Crop to different climatic condition. The present study aimed at comparison of the change in source-sink relationship of the Japonica(J) and that of IndicaxJaponica(I$\times$J) type rice cultivars caused by shift of heading date. Two J- and two I$\times$J-type cultivars were made to head on August 16, August 26, and September 5. Sink capacity was changed by shift of heading date in different mode between the types of cultivars. In both types major determinant of sink capacity was number of effective tillers, and the number of spikelets per panicle was the minor. In J-type earlier planting/heading was beneficial to increased panicle numbers and this was due mainly to a larger diurnal difference in temperature. I$\times$J-type cultivars favored a higher daily mean temperature to increase the sink capacity. The ability of source at heading, in terms of leaf area per panicle, chlorophyll content per spiklet, photosynthetic ability of leaves per unit area at 25$\^{\circ}C$, carbohydrate and N contents of leaves, was not so different among different heading dates in both types. However, the source activity was governed principally by temperature during grain filling. The J-type cultivars headed on Sept. 5 and I$\times$J-type cultivars headed later than August 16 could not have had sufficient source activity in grain filling due to lower temperature.

  • PDF

Experimental Study on Energy Saving through FAN Airflow Control in the Generator Room of a 9200-ton Training Ship (9200톤급 실습선 발전기실 FAN 송풍유량 제어를 통한 선박에너지 절약에 관한 실험적 연구)

  • Moon-seok Choi;Chang-min Lee;Su-jeong Choe;Jae-jung Hur;Jae-Hyuk Choi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.697-703
    • /
    • 2023
  • As a part of the global industrial efforts to reduce environmental pollution owing to air pollution, regulations have been established by the International Maritime Organization (IMO). The IMO has implemented various regulations such as EEXI, EEDI, and CII to reduce air pollution emissions from ships. They are also promoting measures to decrease the power consumption in ships, aiming to conserve energy. Most of the power used in ships is consumed by electric motors. Among the motors installed on ships, the engine room blower that takes up a significant load, operates at a constant irrespective of demand. Therefore, energy savings can be expected through frequency control. In this study, we demonstrated the efficacy of energy savings by controlling the frequency of the electric motor of the generator blower that supplies combustion air to the generator's turbocharger. The system was modeled based on the output data of the turboharger outlet temperature in response to the blower frequency inpu. A PI control system was established to control the frequency with the target being the turbocharger outlet temperature. By maintaining the turbocharger design standard outlet temperature and controlling the blower frequency, we achieved an annual energy saving of 15,552kW in power consumption. The effectiveness of energy savings through frequency control of blower fans was verified during the summer (April to September) and winter (March to October) periods. Based on this, we achieved annual fuel cost savings of 6,091 thousand won and reduction of 8.5 tons of carbon dioxide, 2.4 kg of SOx, and 7.8 kg of NOx air pollutants on the training ship.