• Title/Summary/Keyword: 연소 독성

Search Result 112, Processing Time 0.02 seconds

A Study on the Combustion Characteristics of Organic Insulation Materials According to the Gas Toxicity Evaluation Method (가스유해성 평가방법에 따른 유기단열재의 연소특성에 관한 연구)

  • Shim, Ji-Hun;Lee, Jae-Geol;Han, Kyoung-Ho;Kim, Ju-Wan;Song, Seok-Hun;Jo, Hyung-Won;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.519-524
    • /
    • 2022
  • Domestic building finishing materials are being evaluated according to KS F 2271 standards according to the notification of the Ministry of Land, Infrastructure and Transport, and this test is evaluated using laboratory animals. In this study, experiments were conducted on highly combustible organic insulation materials such as EPS, urethane, and phenolic foam. The purpose of this study was to analyze the cause of the behavioral suspension of the experimental mice by measuring the average behavioral suspension time of the mice caused by the harmful gas generated when these three types of insulation materials were burned. FTIR analysis and smoke density experiment were performed as a cause analysis method for the behavioral suspension of mice, and the experimental results were analyzed by dividing the causes of behavioral suspension into suffocation by particulate matter and toxic inhalation by gaseous substances. As a result of the test, urethane was evaluated as the most harmful insulation material, and as a result of FTIR analysis and smoke density test as a cause analysis for the gas toxicity test results, it is judged that the behavioral stop of the rats by suffocation is higher than the effect of toxic inhalation. This study is a basic study on the cause analysis of harmful gases, and it will be necessary to prepare the toxicity basis and analyze various materials and gases.

A Comparative Study on the Toxicity Evaluation for Fire Smoke by FDS (FDS를 이용한 화재시 연소가스의 독성평가에 관한 비교 연구)

  • Jeong, Beom Jin;Lee, Keun Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • FDS (Fire Dynamics Simulator) is the most widely used computational fluid dynamics software in the fire safety engineering community, and it is applicable to various evaluations of fire growth and its effects. This study made use of a range of outputs from FDS simulation to predict FED (Fractional Effective Concentration) and FEC (Fractional Effective Concentration) levels which are often adopted to evaluate toxicity of fire smoke. As it is not possible to calculate these values directly from outputs of FDS, it was necessary to produce them by means of additional calculation procedures incorporating results of evacuation simulation. In this study, the latest version of FDS, which was recently updated in November 2013, was utilized for the purpose of quantitative comparison with the old version of FDS. As a result, it was found that they make about 10 percent difference on average in predicting FED and FEC levels for the cable fire case study.

The Study of Propellant Characteristic for Low Carbon & High Nitrogen Oxidizer (저탄소 고질소 산화제 적용 추진제 특성 연구)

  • Won, Jong-ung;Choi, Sung-han;Park, Young-chul
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.2
    • /
    • pp.26-31
    • /
    • 2017
  • Environmental problem of the solid propellants is an issue of growing importance in solid rocket. For examples, ammonium perchlorate (AP) as an solid propellants oxidizer could create a poisonous gas and atmospheric pollutions, such as HCl. Among the several oxidizers, N-guanylurea dinitramide (GuDN) is an effective candidate substance for eco-friendly oxidizer, which has high performance, pressure exponent, and eco-friendly smog during combustion for solid propellant of gas generator. In this paper, the theoretical analysis of characteristics as a gas generator propellant, propellant manufacturing processability, propellant hardness properties and combustion characteristics were studied.

Fire test procedures for flammability of bulkhead, ceiling and deck finish materials (선박의 격벽, 천정, 내장재 및 표면바닥재의 화재안정성 평가방법)

  • Kim, S.Y.;Kim, D.S.;Ahn, B.H.;No, H.S.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.157-159
    • /
    • 2007
  • It is very important to protect life, property at sea from any fire. Recommendation on improved fire test procedures for surface flammability of bulkhead ceiling and deck finish materials specifies a procedure for measuring fire characterizing their flammability and thus their suitability for use in marine construction. In this paper we investigated the positive expected by fire test procedures for flammability of bulkhead ceiling and deck finish materials. Also, unusual materials were analyzed. Finally, we suggest methods to solve several problems related to unusual materials.

  • PDF

Analysis of Dioxins and Furans from Bottom Ash Produced in an Municipal Solid Waste Incinerator (도시 소각로 시설의 고형 쓰레기 연소 후 생성된 바닥재 시료에 대한 다이옥신과 퓨란류의 분석)

  • Chang, Yoon-Seok;Hong, JongKi;Kim, Jin-Young
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.7
    • /
    • pp.513-523
    • /
    • 1995
  • Polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) are the most concerned toxic organic pollutants to human. Because of their extremely high toxicity and uncertain genotoxic potential, their determination in environmental and biological samples is of great interest. Municipal solid waste incinerator facilities have been reported as the major contributors of dioxins and furans to the environment, and their formation from combustion is a universal phenomenon, everywhere. In this study dioxins and furans were analyzed from the bottom ash produced during combustion in an municipal waste incinerator located in Seoul. The EPA method was modified for sample pretreatment: the soxhlet method was used for extraction and clean-up procedures were performed by using silica and basic alumina, excluding active-carbon. The extract was then analyzed by HRGC/HRMS. A general trend of increase in the amounts of 6∼7 chlorine-substituted dioxins and furans was observed. Total dioxins, furans and 2,3,7,8-TCDD were determined as 8.05 ng/g, 4.75 ng/g, and 6.93 pg/g, respectively.

  • PDF

Combustion-Retardation Properties of Pinus rigida Treated with Ammonium Salts (암모늄염으로 처리된 리기다 소나무의 난연성)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.627-631
    • /
    • 2010
  • This study was performed to test the combustion-retardation properties of Pinus rigida-based materials by the treatment of ammonium salts. Pinus rigida plate was soaked by the treatment with three 20 wt% ammonium salt solutions consisting ammonium sulfate (AMSF), monoammonium phosphate (MAPP), and diammonium phosphate (DAPP), respectively, at the room temperature. After the drying specimen treated with chemicals, combustion properties were examined by the cone calorimeter (ISO 5660-1). When the ammonium salts were used as the retardant for Pinus rigida, the flame retardancy improved due to the treated ammonium salts in the virgin Pinus rigida. However the specimen shows increasing CO over virgin Pinus rigida and It is supposed that toxicities depend on extents. Also, the specimen with ammonium sulfate showed both the lower total smoke release (TSR) and lower total smoke production (TSP) than those of virgin plate. Among the specimens, the sample treated with diammonium phosphate showed a strong inhibitory effect of combustion.

Analysis of Flame Shape in Flare Stack (플레어스택의 화염 형상 분석)

  • Lee, Heon-Seok;Kim, Bum-Su;Jung, Sang-Yong;Yoo, Jin-Hwan;Park, Chul-Hwan;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.49-53
    • /
    • 2009
  • Relief systems can improve the process safety because it has the function for the prevention of overpressure. Flare stacks is necessary to avoid explosion, radiation, or toxicity by waste-gas emitted from relief system. Safe combustion is one of the important factors to improve safety and the quantity and velocity emitted is ruled in the API code 521. Due to the pressure of released gas and mass flow, a flame from flare stack is similar to jet fire. In this study, we have investigated the effect of flame form on complete combustion and heat emission. API code was similar to jet fire model in flame length, the flame had an effect on the ground.

  • PDF

Study on the Effect of Toxic Gas Filter Effect of Wet Towel during Fire (화재 시 젖은 수건의 유독가스 필터 효과에 관한 연구)

  • Sim, Jaeung;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.52-56
    • /
    • 2018
  • The damage caused by fires is fatal as opposed to the damage caused by heat, and toxic gas generated by fires can be protected against by using a wet towel. In this study, we quantified the filtration effect of gas generated by an actual fire using a wet towel. In order to confirm the filtration effect of the wet towel on three harmful gases ($CO_2$, HCl, HCN), gases passed through a filter using FT-IR were analyzed in realtime. HCl and HCN, which are gases, were filtered by a wet towel, and the detection time of each gas was delayed. Therefore, it was confirmed that evacuation time can be secured by using a wet towel in the case of toxic gas, especially water-soluble gases in an actual fire.

Characteristics of the Particulate Concentrations of Polycyclic Aromatic Hydrocarbons (PAHs) at Gosan in Jeju island (제주도 고산에서 측정한 대기 중 입자상 다환방향족 탄화수소의 농도 특성)

  • 이지이;김용표;강창희
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.83-84
    • /
    • 2003
  • 벤젠고리의 수가 2∼3개인 저분자 PAHs는 대체적으로 급성 독성을 나타내고, 고분자인 벤젠고리 4∼6개의 PAHs들은 대부분 발암성 및 돌연변이성 물질로 알려져 있다. 이러한 PAHs들은 화석연료의 불완전 연소 등에 의해 발생되고, 대표적인 오염원으로는 석탄, 자동차, 가정 난방 등이 있다. 대기 중의 다환방향족탄화수소(PAHs) 농도는 지역별, 계절별로 큰 차이를 나타내며, 일반적으로 차량 통행이 많은 대도시나 공단지역이 높고 계절적으로는 연료사용이 많은 겨울철에 높은 농도를 보인다. PAHs는 다양한 고정 배출원 및 이동배출원에서 발생하기 때문에 동일 배출원에 영향을 받더라도, 지역에 따라 농도 및 조성비가 달라질 수 있다(백성옥, 1999; Simcik et al., 1999). (중략)

  • PDF

나일 틸라피아, Oreochromis niloticus의 cytochrome P450 효소계에 미치는 Aroclor 1254 와 Hexachlorobenzene의 영향

  • 강주찬;조규석;민은영
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.10a
    • /
    • pp.237-238
    • /
    • 2000
  • 최근 산업사회의 발전에 따라 수계 오염문제가 심각하게 대두되고 있다. 따라서 이들 오염물질에 대한 모니터링을 위한 방법들이 강구되고 있으며, 이 중에서 어류 간의 cytochrome P450 호소계는 지방친화성 물질의 오염상태를 평가할 수 있는 물질로 알려지고 있다(Payne et al., 1987). PCBs(Polychlorinated biphenyls)와 HCB(Hexachlorobenzene)는 유기염소계 화합물로서 환경중에 널리 분포하고 있으며, 이중 PCBs는 신경계, 면역계 및 내분비계 등 생체내에 미치는 영향이 크므로 내분비장애물질(endocrine disruptor)로 분류되고 있고, HCB는 독성이 강한 화합물로서 주로 농업에서 fungicide로서 사용되어 왔으며. 다양한 산업 연소과정의 부산물로 발생되고 있다. (중략)

  • PDF