• Title/Summary/Keyword: 연성 설계

Search Result 761, Processing Time 0.026 seconds

Evaluation on Shear Performance of the Dapped Ends of Precast Gerber′s U-Beams (프리캐스트 게르버 U형보의 댑 전단 거동평가)

  • 박현석;유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.492-502
    • /
    • 2002
  • The dapped ends of the Gerber's beam were designed by PCI(Prestressed Concrete Institute) and CPCI(Canadian Prestressed Concrete Institute) methods. The depths of nibs with precast and topping concrete, which were halves of the total beam depth, were 77 cm md 18.2 cm, respectably. Shear tests were performed on four full scale beam ends. All specimens designed by PCI and CPCI methods showed crackings at the re-entrant coner of dap before the 32 % of full service design loading, and failed at the load level higher than their design strength but less than their calculated nominal strength. The specimens with increased hanger reinforcement show more effective in development of initial crackings, more ductile in failure with distributed crackings, and failed in higher strength than those of PCI requirement. The tested specimens designed by CPCI method were more ductile in failure than those of the PCI methods.

Ignition Safe-Arm-Unit Using Micro-Electromechanical Systems (MEMS를 이용한 추진기관 점화안전장치)

  • Jang, Seung-Gyo;Lee, Sang-Hun;Chang, Hyun-Kee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.282-285
    • /
    • 2009
  • Ignition Safe-Arm-Unit using micro-electromechanical systems(MEMS) for propulsion system was designed and manufactured. MEMS was designed according to the design schemes for conventional mechanical elements. By comparing the design results and the test data of the prototype, small discrepancy was found, which is due to the nonlinear characteristic of the structure and the machining accuracy. The applicability of MEMS for Safe-Arm-Unit was proved by testing MEMS which is assembled into SAU.

  • PDF

The Design Eccentricity for Torsionally Unbalanced Structure (비틀림 거동을 하는 구조물의 설계 편심)

  • 조소훈;이명규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.63-72
    • /
    • 2001
  • In this paper, to satisfy the safety and economy immediately, we assume the center of lateral load in case the dynamic motion of the torsionally unbalanced structure is transformed into the static lateral load using modal analysis and proposes a method to control the design eccentricity in order to make the center of lateral load coincide with the center of strength. And when the structure is designed by proposed method, it is shown that the structure designed by proposed method does not demand excessive additional ductility in comparison with the structure designed by provisions of other seismic building code.

  • PDF

Local Deformation Based Design Concept for Multi-layered Pipeline (국부 변형을 고려한 다중관 설계 기법)

  • Won, Jong-Hwa;Kim, Moon-Kyum;Kim, Kyu-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.570-573
    • /
    • 2011
  • 본 논문에서는 배관의 국부변형을 고려하여 각 배관의 특성으로 인하여 발생하게 되는 최대 응력 발생지점에 대한 평가 및 설계기법을 제안한다. 다중관은 일반적으로 배관의 매설 조건이 불안정한 곳이나 배관의 내부 유체의 유출 모니터링 및 난방관 등의 보온을 목적으로 사용되나, 다중관의 거동에 대한 거동 및 설계에 대한 연구는 미비한 실정이다. 본 연구에서 제안한 기법은 탄성범위에서 거동하는 연성관을 대상으로 하며 외관의 형상 및 외부 하중에 의하여 예상되는 국부 변형을 설계 인자로 고려하는 방법이다. 일반적인 원형관의 경우 관의 하단부에서 가장 큰 국부 변형 반경을 나타나며, 국내외에서 사용하고 있는 정사각 콘크리트 보호공의 경우 관의 상측, 하측부($45+90n^{\circ}$)에서 가장 큰 반경을 관찰할 수 있다. 이는 내압이 작용하는 구조물에 대하여 낮은 압력에도 항복에 이르는 환경을 제공하기 때문에 설계 시 반영되어야 할 중요한 요소이다.

  • PDF

A Study for Shear Deterioration of Reinforced Concrete Beam-Column Joints Failing in Shear after Flexural Yielding of Adjacent Beams (보의 휨항복 후 접합부가 파괴하는 철근콘크리트 보-기둥 접합부의 전단내력 감소에 대한 해석적 연구)

  • Park, Jong-Wook;Yun, Seok-Gwang;Kim, Byoung-Il;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.399-406
    • /
    • 2012
  • Beam-column joints are generally recognized as the critical regions in the moment resisting reinforced concrete (RC) frames subjected to both lateral and vertical loads. As a result of severe lateral load such as seismic loading, the joint region is subjected to horizontal and vertical shear forces whose magnitudes are many times higher than in column and adjacent beam. Consequently, much larger bond and shear stresses are required to sustain these magnified forces. The critical deterioration of potential shear strength in the joint area should not occur until ductile capacity of adjacent beams reach the design demand. In this study, a method was provided to predict the deformability of reinforced concrete beam-column joints failing in shear after the plastic hinges developed at both ends of the adjacent beams. In order to verify the deformability estimated by the proposed method, an experimental study consisting of three joint specimens with varying tensile reinforcement ratios was carried out. The result between the observed and predicted behavior of the joints showed reasonably good agreement.

Flexural Strength of Composite HSB Girders in Positive Moment (HSB 강합성거더 정모멘트부의 휨저항강도)

  • Cho, Eun-Young;Shin, Dong-Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.389-398
    • /
    • 2010
  • The flexural strength of composite HSB I-girders under a positive moment was investigated using the moment-curvature analysis method to evaluate the applicability of the current AASHTO LRFD design specifications to such girders. A total of 2,391 composite I-girder sections that satisfied the section proportion limits of the AASHTO LRFD specifications was generated by the random sampling technique to consider a wide range of section properties. The flexural capacities of the sections were calculated inthe nonlinear moment-curvature analysis in which the HSB600 and HSB800 steels were modeled as an elasto-plastic strain-hardening material, and the concrete, as a CEB-FIP model. The effects of the ductility ratio and the compressive strength of the concrete slab on the flexural strength of the composite girders made of HSB and SM520-TMC steels were analyzed. The numerical results indicated that the current AASHTO LRFD equation can be used to calculate the flexural strength of composite girders made of HSB600 steel. In contrast, the current AASHTO LRFD equation was found to be non-conservative in its prediction of the flexural strength of composite HSB800 girders. Based on the numerical results of this study for 2,391 girders, a new design equation for the flexural strength of composite HSB800 girders in a positive moment was proposed.

Quasi-Static Test for Seismic Performance of Circular Hollow RC Bridge Pier (원형 중공 콘크리트 교각의 내진성능에 대한 준정적 실험)

  • 정영수;한기훈;이강균;이대형
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.41-54
    • /
    • 1999
  • Because of relatively heavy dead weight of concrete itself and unavoidable heat of massive concrete in bridge piers, circular hollow columns are widely used in Korean highway bridges. Since the occurrence of 1995 Kobe earthquake, there have been much concerns about seismic design for various infrastructures, inclusive of bridge structures. It is, however, understood that there are not much research works for nonlinear behavior of circular hollow columns subjected to eqrthquake motions. The objective of this experimental research is to investigate nonlinear behavior of circular hollow reinforced concrete bridge piers under the quasi-static cyclic load, and then to enhance their ductility by strengthening the plastic hinge region with glassfiber sheets. Particularly for this test, constant 10 cyclic loads have been repeatedly actuated to investigate the magnitude of strength degradation for the displacement ductility factor. Important test parameters are seismic design, confinement steel ratio, axial force and load pattern. It is observed from quasi-static tests for 7 bridge piers that the seismically designed columns and the retrofitted columns show better performance than the nonseismically designed colums, i.e. about 20% higher for energy dissipation capacity and about 70% higher for curvatures.

  • PDF

Seismic Performance of a Non-Seismic Designed Pier Wall and Retrofit Concept (비내진 벽식 교각의 내진성능 및 보강개념)

  • Hoon, Lee-Jae;Ho, Choi-Young;Soon, Park-Kwang;Seok, Ju-Hyeong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.6
    • /
    • pp.87-98
    • /
    • 2009
  • It is well known that reinforcement details in the plastic hinge region of bridge piers give the most important effects on the seismic performance of bridges, from investigations of bridge failures in many earthquake events and in laboratory tests. Longitudinal reinforcement details give larger effects than lateral reinforcement details do. The lap-spliced longitudinal steel shows slip during earthquake events, which results in low ductility and inadequate seismic performance. However, before the issue of the earthquake design code, a considerable number of bridge piers were constructed with lap-spliced longitudinal steel in the plastic hinge region. Therefore, a large amount of research has been conducted on the seismic performance and retrofit of circular and rectangular shaped bridge columns with lap-spliced longitudinal steel. However, research on wall type piers is very limited. This paper investigates the seismic performance of a pier wall by a quasi-static test in the weak axis direction and proposes a retrofit method. From the test with variables being the longitudinal steel detail and the transverse steel amount, it is shown that the currently used definition of yield displacement is not adequate. Therefore a new definition of yield displacement for the ductility investigation for a pier wall is proposed. In addition, a retrofit method by steel plates and bolts is proposed to improve ductility, and test results show that slip of the longitudinal steel is prevented by up to a considerably large displacement.

Cyclic Local Buckling Behavior of Steel Members with Web Opening (유공 강구조 부재의 반복 국부좌굴거동)

  • Lee, EunTaik;Ko, KaYeon;Kang, JaeHoon;Chang, KyoungHo
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.423-433
    • /
    • 2003
  • Many study have been performed to describe the elastic and inelastic behavior of H-shaped beams with web openings that generally concentrated on the monotonic loading condition and concentric web opening. The findings of the studies led Darwin to propose formulas for the design of beams with web openings considering local buckling. While the formulas are simple and useful in real situation, more studies arc needed on their cyclic loading condition. In this experimental study, 12 H-shaped beams with web openings under cyclic loading condition were investigated. The dimension criteria based on the formulas proposed by Darwin were examined. The suitability of existing design formulas and the effects of plastic hinges on beams with web openings and of local buckling around web openings on the beam strength under cyclic loading were also studied. This was done by observing their behavior with various dimensional openings, eccentric per cent, and stiffeners.

Interaction between Flexible Buried Pipe and Surface Load

  • Yoo, Chung-Sik;Chung, Suk-Won;Lee, Kwang-Myung;Kim, Joo-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.3
    • /
    • pp.83-97
    • /
    • 1999
  • This paper presents the results of a parametric study on the interaction between buried pipes and surface load using the finite element method of analysis. A series of laboratory model tests were also performed in order to validate the adopted finite element model and to capture essential features of the physical behavior of buried pipes subjected to surface load. In the parametric study, a wide range of boundary conditions were analyzed with emphasis on the response of the buried pipes to surface load. The results of analysis such as contact stress distribution at the soil/pipe interface and axial thrust of the pipe were thoroughly analyzed, and a database on the response of buried pipe under surface load was established for future development of a semi-empirical design/analysis method. The results indicated that the degree of interaction between buried pipes and surface load significantly varies with the vertical and lateral location of pipe with respect to surface load, and that the current design method, which does not consider soil-structure interaction, cannot correctly capture the pipe response to surface loading. Furthermore, based on the results of analysis, a semi-empirical equation was suggested, which estimates the maximum pipe thrust due to surface load for flexible buried pipes.

  • PDF