• Title/Summary/Keyword: 연성재하

Search Result 386, Processing Time 0.034 seconds

An Experimental Study on Flexural Strength of SC Composite Beams Enforced by Unbonded Post Tension (비부착 포스트텐션 SC합성보의 휨내력에 관한 실험적 연구)

  • Kim, Heui Cheol;Ahn, Hyung Joon;Ryu, Soo Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.135-144
    • /
    • 2009
  • This study aims to suggest an appropriate flexural reinforcement technique by evaluating the reinforcement capacity of specimens that underwent flexural reinforcement according to the post-tension method with the anchoring position of an unbonded tension member on the conventional SC composite beam and the applied tension level as variables. For the experiment, up to a predetermined yield load was applied to each type of specimen and then, unbounded post-tensioning was additionally conducted to examine its reinforcement capacity. The analysis of the said experiment showed that the post-reinforced SC composite beam was characterized by significantly improved yield stress and initial stiffness, compared with the pre-reinforced one and the experimental measurements/theoretical values of maximum stress ranged from 0.95 to 1.13 following reinforcement. There was little or no change depending on the maximum stress and tension in the specimen (D160, Class 240) whose neutral axis and upper part had anchoring devices mounted prior to reinforcement. Rather, the ductility decreased with the increasing tension. On the contrary, in the case of the other specimen (Class D120) whose neutral axis had anchoring devices mounted after reinforcement, both the maximum stress and ductility increased with increasing tension, which indicates that the latter tension reinforcement was reasonably appropriate and effective for the neutral axis reinforcement.

Performance of Fresh and Hardened Ultra High Performance Concrete without Heat Treatment (상온 양생한 초고성능 콘크리트(UHPC)의 경화 전과 후의 성능 관계)

  • Kang, Sung-Hoon;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.23-34
    • /
    • 2014
  • This study investigates the relationship between the performance of fresh and hardened Ultra-High Performance Concrete (UHPC) without heat treatment. The performance of fresh UHPC is determined by the slump flow test related to the fluidity of concrete mixtures, and the air content test. The variables of these tests are the water to binder ratio, superplasticizer dosages and volume fractions of steel fiber. Generally, insufficient fluidity and excessive air contents in concrete mixtures lead to the insufficient packing density related to the performance of harden concrete. The performance of hardened UHPC is determined by the compressive and flexural tensile tests. The results of the fresh UHPC tests show that there is the linear correlation between each variable and the slump flow diameter, and that the slump flow diameter is linearly decreased as the air content ratio increase. Using these results, the formula is developed to predict the fresh performance before mixing UHPC. The results of the hardened UHPC tests show that the hardened performance is not influenced by the air content ratio in the range of 3.2 to 4.2 per cent. However, the flexural tensile strength dominantly influenced by the volume fractions of steel fiber.

Analysis of Behavior on GCP Composite Ground Considering Loading and Foundation Conditions (하중 및 기초조건에 따른 GCP 복합지반의 거동분석)

  • Kim, Gyeong-Eop;Park, Kyung-Ho;Kim, Dae-Hyeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.1
    • /
    • pp.127-137
    • /
    • 2018
  • Gravel Compaction Pile (hereinafter referred to as GCP) is a ground improvement technique by packing crushed stones on fragile clay ground, pressing it, and forming stakes on the foundation. Although many researchers have analyzed stress behavior of GCP composite ground on domestic GCP technique using laboratory experiment and field experiment, analyses of stress behavior according to the difference of stiffness of mat foundation loaded on the upper foundation of GCP composite ground have not been done actively. Therefore, this study aimed to identify the stress concentration ratio in accordance with the difference of basis stiffness by interpreting figures. To perform this, replacement ratio was changed and modelled using ABAQUS, software for finite element analysis and analyzed the stress concentration ratio, amounts of settlement, and maximum amounts of horizontal displacement of composite ground in accordance with the difference of stiffness. An analysis showed that the stress concentration ratio of rigid foundation was highly assessed than unloading of flexible foundation in case of unloading, while amounts of settlement under flexible unloading condition were slightly higher than under rigid condition. This indicates that the characteristic of stress behavior on the different stiffness of upper foundation needs to be clarified. In addition, the maximum horizontal displacement was generated in a constant level regardless of the difference of stiffness.

Flexural Behavior of Segmental U-Girder and Composite U-Girder Using Ultra High Performance Concrete (초고강도 섬유보강 콘크리트를 사용한 분절형 U거더 및 합성 U거더의 휨거동)

  • Lee, Seung-Jae;Makhbal, Tsas-Orgilmaa;Kim, Sung-Tae;Han, Sang-Mook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.290-297
    • /
    • 2017
  • The flexural behavior tests of UHPC segmental U-girder and composite U-girder which has 160MPa compressive strength and 15.4m length were carried out. The test variables are volume fraction of steel fibers and slab over the U-girder. Each U-girder has longitudinal re-bars in web and lower flange. PS tendons which has 2 of 15.2mm diameter in upper flange and PS tendons which has 7 of 15.2mm diameter in lower flange were arranged and prestressed at onetime in U-girder connection stage. Enough strong prestressing force which applied to U-girder due to ultra high performance concrete strength can withstand the self weight and dead load in U-girder stage. By comparison with the brittle behavior of U-girder, composite U-girder showed the stable and ductile behavior. After the construction of slab over U-girder, flexural load capacity of composite U-girder can bear the design load in final construction stage with only one time prestressing operation which already carried out in U-girder stage. This simple prestressing method due to the ultra high strength concrete have the advantage in construction step and cost. The shear key which has narrow space has the strong composite connection between ultra high strength concrete U-girder and high strength concrete slab didn't show any slip and opening right before failure load.

Strength Prediction Model of Interior Flat-Plate Column Connections according to Design Parameters (설계변수에 따른 플랫플레이트-기둥 접합부의 강도산정모형)

  • Lee, Do-Bum;Park, Hong-Gun;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.405-414
    • /
    • 2006
  • In the present study, a numerical analysis was performed for interior connections of continuous flat plate to analyze the effect of design parameters such as column section shape, gravity load and slab span on the behavioral characteristics of the connections. For the purpose, a computer program for nonlinear FE analysis was developed, and the validity was verified. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases and gravity load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. And as the slab span loaded with relatively large gravity load increases, the negative moment around the connection increases and therefore the strength of connection against unbalanced moment decreases. By considering the effect of design parameters on the strength of the connections, the effective shear strength to calculate the torsional moment capacity of connection was proposed and the effectiveness of the proposed shear strength was verified.

Seismic Performance of High Strength Steel(HSA800) Beam-to-Column Connections with Improved Horizontal Stiffener (개량수평스티프너를 보강한 고강도강(HSA800) 접합부 내진성능평가)

  • Oh, Sang Hoon;Park, Hae Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.361-373
    • /
    • 2014
  • As the height and beam span of buildings built in the construction market increase, increasingly higher quality is being required of the construction materials. In response to this trend, 800MPa tensile strength class steel was developed in domestic company. Currently, experiments applying flexural member, compression member, and connections are continuously conducted, but a design guideline for high strength steel has yet to be established. Among those construction materials, for the high strength steel beam-to-column connections, the evaluation of implementing ductile connections for the high strength steel beam-to-column connections is producing pessimistic results and the number of related researches is inadequate because of the high yield ratio, which is the characteristic of high strength steel. This study on implementation of ductile connections made of high strength steel was conducted using the connection detail as the variable, for the purpose of enhancing the deformation capacity of high strength steel beam-to-column connections. Cyclic loading test and nonlinear finite element analysis were conducted with full-scale mock-up connection models with the applied connection details. As a result, the structural performance of high-strength steel beam-to-column connection with presented detail was contented with demand of Special Moment Frames of KBC standard.

전주전단대 화강암류의 SHRIMP U-Pb 저어콘 연령측정: 호남전단대의 운동시기에 대한 고찰

  • 이승렬;이병주;조등룡;기원서;고희재;김복철;송교영;황재하;최범영
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2003.05a
    • /
    • pp.55-55
    • /
    • 2003
  • 호남전단대는 옥천대 남서부지역에 북동 내지 북북동 방향으로 발달하는 일련의 우수향 연성전단대로 한반도를 포함하는 동북아 지역의 중생대 부가작용과 관련하여 매우 중요한 조구조적 요소이며, 특히 북중국 대륙과 남중국 대륙이 유라시아 대륙에 부가되는 과정과 관련하여 동북아 지역의 중생대 지체구조 발달사를 설정하는데 매우 중요하게 생각되고 있다. 그러나 이러한 조구조적 중요성에도 불구하고 호남전단대의 정확한 운동 시기는 아직 밝혀지지 않고 있다. 이번 연구는 전주전단대가 지나가는 김제 금산사 지역과 무안 지역에 분포하는 화강암류를 대상으로 SHRIMP U-Pb 저어콘 연대 측정을 실시하여 전단운동시기를 밝혔다. 금산사 지역은 엽리상 각섬석-흑운모 화강섬록암이 흑운모 화강암에 포획된 명확한 지질학적 증거를 보이고 있는 곳으로 화강섬록암의 U-Pb 저어콘 연대는 172.7 $\pm$ 1.4 Ma이며 화강암의 연대는 169.6 $\pm$ 1.8 Ma과 167.5 $\pm$ 2.4 Ma로 구해졌다. 따라서 전주전단대의 전단운동은 약 173 - 170 Ma 기간에 일어났다. 특히 화강암 내에 포획된 화강섬록암 내에는 전반적인 우수향 전단운동 후기에 관입한 다수의 석영질 맥이 좌수향의 전단운동을 받은 증거가 관찰되는데 이러한 사실은 우수향의 전단운동 이후 화강암의 관입 이전에 좌수향의 전단 운동이 있었음을 지시한다. 무안 지역은 전주전단대의 끝 부분에 해당하는 곳으로 각섬석화강섬록암과 이를 관입한 각섬석화강암이 모두 우수향의 전단운동을 받았다. 화강섬록암의 U-Pb 저어콘 연대는 176.3 $\pm$ 1.7 Ma이며 화강암의 연대는 165.8 $\pm$ 2.0 Ma로 구해졌으며, 따라서 최종 우수향 전단운동의 시기는 166 Ma 이후로 생각된다. 무안 지역에 분포하는 화강섬록암과 화강암의 관입시기는 금산사 지역의 화강섬록암과 화강암과 각각 조화적이다. 호남전단대의 운동 시기를 밝히기 위해 전주전단대에 해당하는 금산사 지역과 무안 지역에 분포하는 화강암류에 대한 U-Pb 저어콘 연대 측정을 실시한 결과 호남전단대의 특징적인 우수향 전단운동은 적어도 2회에 걸쳐 일어났음을 알 수 있다. 즉 첫 번째 광역적인 전단운동은 약 173 - 170 Ma 시기에 일어났으며, 두 번째 전단운동은 166 Ma 이후에 일어났음을 알 수 있다. 한편 전기의 우수향 전단운동은 후기 화강암 관입 이전에 좌수향 전단 운동에 의해 부분적으로 재활성 되었으며, 후기 화강암의 관입 이후에 재차 우수향 전단운동으로 활성화 되었음을 알 수 있다. 이상의 결과를 종합하면 호남전단대는 쥬라기 중기에 발생한 광역적인 우수향의 연성전단운동이나, 운동 특성은 연속적이기 보다는 단속적으로 일어난 것으로 생각된다.

  • PDF

Numerical Study on Seismic Performance Evaluation of Circular Reinforced Concrete Piers Confined by Steel Plate (강판으로 보강된 원형철근콘크리트교각의 내진성능 평가에 관한 해석적 연구)

  • Lee, Myung-Jin;Park, Jong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.116-122
    • /
    • 2021
  • This study quantitatively evaluated the performance improvement of a circular reinforced concrete pier under dynamic load with strengthening using a steel plate. Various three-dimensional elements were applied using the finite element program ABAQUS. The analytical parameters included the ratios of the steel cover length to the pier's total height and the ratios of the steel cover thickness to the pier diameter for inelastic-nonlinear analysis. The lower part of the pier had fixed boundary conditions, and lateral repetitive loads were applied at the top of the pier. The pier was investigated to evaluate the dynamic performance based on the load-displacement curve, stress-strain curve, ductility, energy absorption capability, and energy ratio. The yield and ultimate loads of piers with steel covers increased by 3.76 times, and the energy absorption capability increased by 4 times due to the confinement effects caused by the steel plate. A plastic hinge part of the column with a steel plate improved the ductility, and the thicker the steel plate was, the greater the energy absorption capacity. This study shows that the reinforced pier should be improved in terms of the seismic performance.

Geological Structures of the Hadong Northern Anorthosite Complex and its surrounding Area in the Jirisan Province, Yeongnam Massif, Korea (영남육괴 지리산지구에서 하동 북부 회장암복합체와 그 주변지역의 지질구조)

  • Lee, Deok-Seon;Kang, Ji-Hoon
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.287-307
    • /
    • 2012
  • The study area, which is located in the southeastern part of the Jirisan province of the Yeongnam massif, Korea, consists mainly of the Precambrian Hadong northern anorthosite complex (HNAC) and the Jirisan metamorphic rock complex (JMRC) and the Mesozoic granitoids which intrude them. Its tectonic frame is built into NS trend, unlike the general NE-trending tectonic frame of Korean Peninsula. This paper researched the structural characteristics at each deformation phase to clarify the geological structures associated with the NS-trending tectonic frame which was built in the HNAC and JMRC. The result indicates that the geological structures of this area were formed at least through three phases of deformation. (1) The $D_1$ deformation formed the $F_1$ sheath or "A"-type folds in the HNAC and JMRC, and the $S_{0-1}$ composite foliation and the $S_1$ foliation and the $D_1$ ductile shear zone which are (sub)parallel to the axial plane of $F_1$ fold, and the $L_1$ stretching lineation which is parallel to the $F_1$ fold axis owing to the large-scale top-to-the SE shearing on the $S_0$ foliation. (2) The $D_2$ deformation (re)folded the $D_1$ structural elements under the EW-trending tectonic compression environment, and formed the NS-trending $F_2$ open, tight, isoclinal, intrafolial folds with the $S_{0-1-2}$ composite foliation and the $S_2$ foliation and the $D_2$ ductile shear zone with S-C-C' structure and the $L_2$ stretching lineation which is (sub)parallel to the axial plane of $F_2$ fold. The extensive $D_2$ ductile shear zone (Hadong shear zone) of NS trend was persistently developed along the eastern boundary of HNAC and JMRC which would be to the limb of $F_2$ fold on a geological map scale. The Hadong shear zone is no less than 1.4 km width, and was formed in the mylonitization process which produced the mylonitic structure and the stretching lineation with the reduction of grain size during the $F_2$ passive folding. (3) The $D_3$ deformation formed the EW-trending $F_3$ kink or open fold under the NS-trending tectonic compression environment and partially rearranged the NS-trending pre-$D_3$ structural elements into (E)NE or (W)NW direction. The regional trend of $D_1$ tectonic frame before the $D_2$ deformation would be NE-SW unlike the present, and the NS-trending tectonic frame in the HNAC and JMRC like the present was formed by the rearrangement of the $D_1$ tectonic frame owing to the $F_2$ active and passive folding. Based on the main intrusion age of (N)NE-trending basic dyke in the study area, these three deformation events are interpreted to have occurred before the Late Paleozoic.

A Study on the Evaluation of Field Installation Damage and Strength Reduction Factor of Geogrid for Reinforced Retaining Wall (보강토 옹벽용 지오그리드의 현장 내시공성 및 강도 감소계수 평가에 관한 연구)

  • Park, Juhwan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.7
    • /
    • pp.5-12
    • /
    • 2012
  • Recently the installation of reinforced earth retaining walls in the domestic construction site has increased, surpassing conventional RC walls. These reinforced walls have various types depending on the reinforcing material, installation method and the form of face panel. However, there are difficulties in design and construction management due to the unproved safety of construction method. In case of reinforcing materials, despite the fact that they come in all different sizes and types produced by small businesses or partially imported with cheap price and low quality, no proper standards for designing the walls have been suggested. In order to apply reinforced retaining wall system to broad cases and design the walls effectively considering site conditions, specific design and construction guidelines for efficient construction management are needed. In conclusion, this study verified that reduction factors can be greatly affected by grain sizes and stiffness of backfill materials and granularity range, therefore in case of relatively large construction site, it is required to redesign the reinforced retaining wall by evaluating site installation resistance test, applying respective reduction factors to each backfill material and select the right geogrid depending on the usage of retaining wall so as to enhance the safety of reinforced earth retaining walls with efficiency.