• Title/Summary/Keyword: 연돌 효과

Search Result 77, Processing Time 0.021 seconds

The Influence on the Stack effect that Pressure differential system to smoke control in High-rise buildings (초고층 건축물에서 급기가압제연이 연돌효과에 미치는 영향)

  • Lim, Chae-Hyun;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.235-238
    • /
    • 2008
  • High-rise buildings with stack effect caused by the foreclosure, which significantly delayed the spread of a fire in effects of these stack effect driving force said. In this research on the stack effect of the lobby if the pressurization of the stairwell analysis of the pressure distribution of the CONTAMW. Overall, the pressurization of the lobby makes it stairwell amount of pressure(+) to the zone in pressure designed to prevent the spread of smoke control performance and found that, the way a normal state and sub-pressurization in the stairwell with stack effect of the turbulence Such as the formation of the upper flow, but, in the upper atmosphere with pressurization was formed by the underlying trend.

  • PDF

Furnace Performance Analysis Fired with Oil Using Atomizers (압축 공기 분사식 버너를 이용한 오일 연소시의 연소로 성능분석에 관한 연구)

  • 한규일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.2
    • /
    • pp.192-203
    • /
    • 1990
  • 여러 가지 다른 형태의 노즐을 공기 선회식 버너와 공기의 선회가 없는 버너(CB-125 Burner)에 장치하여 공기 분사식으로 오일을 분사하여 연소로에서 연소시켰다. 연소로는 길이 3m에 약 1m 상(3) 의 연소공간을 가졌으며 상부에는 열전대를 장치하고 하부에는 물이 흐르는 관을 설치하여 열효율을 계산할 수 있게 설계하였다. 연소로 연돌부에는 CO 하(2), CO, O 하(2) 가스 분석기를 사용하여 과잉공기량과 고온계로 배기가스 온도를 측정하도록 하였다. 모든 측정치는 연소곡선과 효율곡선에 의하여 얻어진 상수를 이용하여 계산한 연소로 성능방정식에 의하여 평가하였다. 실험치에 의해 계산한 벽면 열손실량과 열전달 공식에 의해 산출한 열손실량을 비교 분석하여 측정치의 정확도를 추정하고 과잉공기의 효과도 검토하였다. 그 결과 본 연구에서 사용된 두 종류의 버너와 여러 형태의 노즐이 오일 연소시 열효율 면에서 큰 차이를 보이지 않고 있음을 알았다.

  • PDF

초고층아파트 최적 설비시스템 개발 -급수설비시스템 개발을 중심으로-

  • 이대원;김태형;최도혁;김종필
    • 월간 기계설비
    • /
    • s.35
    • /
    • pp.84-96
    • /
    • 1993
  • 본 연구는 '초고층 아파트 최적 설비시스템 개발'의 제2차년도 연구로서 아직까지 국내에서 확립되어 있지 않은 초고층 아파트 급수설비 시스템 및 수격방지 시스템의 모델정립과 연돌효과에 의한 열손실 추정 및 적정 설계 지침 설정에 관한 연구를 수행하였다. 이를 위하여 이론 해석 및 현장실험을 수행하였고, 결과분석을 통하여 최적화 설계방안도 아울러 도출하였다. 급수설비 분야에서는 각종 급수 시스템의 해석 및 비교를 통한 효율적인 시스템의 설계 및 선정방법을 제시 하였고, 실제 초고층 아파트에 대한 수격현상 해석 및 실험을 통하여 수격작용의 영향을 감소시킬 수 있는 설계방안을 검토하였다. 또 입주중인 초고층 아파트 현장에서의 실측을 통하여 건물의 높이에 따라 불균일한 틈새가 있는 일반적인 경우에 대한 모델을 정립하였고, 수치해석을 통한 수직통로 내의 실제 열유동 현상을 정량화하고 설계지침을 제시하였다. 결과로서 각종 급수시스템의 해석을 위한 프로그램을 개발하였고, 수격의 발생을 억제하기 위한 최적 밸브 폐쇄형태를 제시하였으며, 초고층 건물의 내외부에 형성되는 압력차와 유인풍량 및 열손실량 사이의 관계식을 얻었다.

  • PDF

The Study on Optimization of HVAC Systems Design in Tall Buildings (초고층 건축물의 최적화된 설비시스템 설계를 위한 기초연구)

  • Yu, Jung-Yeon;Cho, Dong-Woo;Yu, Ki-Hyung
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.11-18
    • /
    • 2005
  • The optimized HVAC system design in tall buildings enable owners to save unnecessary energy consumption and residents to have comfort environments. The purpose of this study is to develop design process for optimized HVAC system design in tall buildings. As basic researches, literature researches and case studies of HVAC system design in tall buildings were performed. Survey was processed among expert in the field and key considerations on HVAC system design were drew as conclusions. With these conclusions, studies were performed on effects of wind velocity, outdoor air temperature, and solar radiation that are main factors of load calculation in tall buildings. Finally, air-tightness and stack effect were analyzed and estimated by literature studies, field measurements and computer simulations.

A Study on the Performance of Natural Ventilation of Solar Chimney Using Stack Effect (연돌 효과를 이용한 태양열 굴뚝의 자연환기 성능에 관한 연구)

  • Cho, S.W.;Lee, J.Y.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.2
    • /
    • pp.35-43
    • /
    • 2001
  • The results of numerical simulation on the performance of a solar chimney system in building are described. The inside surface temperature of four walls within the solar chimney arc calculated with solar radiation and outdoor temperature in summer. The air within the solar chimney is heated by conduction, convection and radiation. Air temperature distribution from the bottom to the top and outlet air temperature can be obtained by solving energy balance equation. Since the buoyance or stack effect is affected by temperature difference between the bottom and the top within the solar chimney. It is evaluated using inlet and outlet temperatures. It is expected that natural ventilation by the solar chimney of witch the height is 7.8m and the cross sectional area is $4.93m^2$ can provide about $6400m^3/h$ on sunny day.

  • PDF

A Study on the Historical Comparative of Smoke Control for Fire Safety Law and Building Law (국내의 연기제어 관련 소방법과 건축법의 변천과정에 관한 연구)

  • Kim, Hye-Won;Jin, Seung-Hyun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.97-98
    • /
    • 2017
  • These days the buildings are getting higher, bigger, and in a deep. According to that, it was the Large-Scale casuality by smoke from Daeyeongak Hotel fire in 1971 to Uijeongbu apartment fire in 2015, and the law of smoke control has consistently changed. but the analysis for improving the law isn't working. Therefore on this study, it conducts the analysis of historical comparative about smoke control and it will present the basic data for improving the law of smoke control and in-depth analysis.

  • PDF

The Influence on the Stack Effect with the Opening of Smoke Ventilators in High-rise Buildings (초고층 건축물에서 배연창 개방이 연돌효과에 미치는 영향)

  • Lim, Chae-Hyun;Kim, Bum-Gyue;Yeo, Yong-Ju;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.209-213
    • /
    • 2008
  • The effects on the performance of natural smoke exhaust ventilators installed in high-rise buildings were analyzed depending on the wind velocities and smoke temperatures using CONTAMW tool. The results showed that the smoke exhaust ventilators can maintain given performances in such conditions as low smoke temperatures and low wind velocities. However, high smoke temperatures and high wind velocities can prevent the smoke ventilators to exhaust smokes from the fire room. Significant changes in stack effects in high-rise buildings can also occur with the opening of smoke ventilators in the fire floor.

  • PDF

A Study on the Stack Effect Characteristics in High-Rise Apartments (초고층 주상복합 아파트의 연돌효과 특성에 관한 연구 -D 프로젝트를 중심으로-)

  • Choi, Dong-Tak;Son, Won-Tug;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.1
    • /
    • pp.37-43
    • /
    • 2011
  • Study of stack effects in the early design stage is the most appropriate moment to draw any problems and provide the right solutions. However, In a real process, The pre-design planning stage review is not thoroughgoing enough to high-rise construction site. Therefore, this study has reviewed by selecting one of inappropriate project [D] to find the possible stack effect alternatives in an early design documentation stage and provide countermeasures to be a foundations of stack effect in the construction stages.

A Study on Improving the Fire Performance of Elevator Shaft in Existing Buildings (기존 건축물의 승강로 화재안전성능 개선 방안에 관한 연구)

  • Choi, Keum-Ran;Ryu, Seung-Kwan;Yoon, Myung-O
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.303-310
    • /
    • 2010
  • 기존 건축물은 현행 소방법 및 건축법을 소급해 적용할 수 없다는 이유로 비상용승강기와 제연설비가 설치되어 있지 않는 경우가 상당수 존재한다. 이렇듯 화재에 취약할 수밖에 없는 기존 건축물에서 화재가 발생했을 때 소방대 진입 및 구조활동이 가능한 통로를 확보하는 것이 매우 중요하다. 본 연구는 이러한 관점에서 기존 건축물의 화재안전성능 개선에 따른 부담을 최소화하는 방안으로 승강로 급기가압 방식을 제시한다. 먼저, 수직통로를 통한 연기 확산에 무방비 상태인 기존의 고층 건축물의 문제점 및 화재사례를 분석하고, 국내외 비상용승강기 및 제연설비 관련 법규 현황을 비교분석하였다. 그리고 NIST의 Contam을 이용한 시뮬레이션을 통하여 승강로 급기가압 전과 후의 층별 차압을 비교함으로써 승강로 가압이 연돌효과에 미치는 영향을 분석하였다.

  • PDF

A Sutdy on the Pressure Distribution Characteristic of High-rise Buildings in Fire Using Computer Simulation (시뮬레이션을 이용한 화재 시 고층건축물의 압력분포 특성에 관한 연구)

  • Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.49-50
    • /
    • 2019
  • In the case of High-rise buildings, it has a problem by stack effect that rise of vertical height. Especially in case of fire, it need to the consideration of stack effect that it has bigger than general. Therefore in this study, we used to the Contamw and FDS simulation for analysis of stack effect and pressure distribution characteristic in fire. As a result the Contamw simulation shows the pressure distribution by stack effect in general high-rise buildings. However, in case of fire, the height of the neutral plane is lowered and stack effect is larger. Therefore, it is necessary to multiply analyze the temperature distribution and the stack effect in fire.

  • PDF