• Title/Summary/Keyword: 연기농도

Search Result 162, Processing Time 0.022 seconds

A Study on the Model Experiment for Smoke Flow in Road Tunnel Fire (도로터널 화재발생시 연기유동에 관한 축소모형실험 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kang, Se-Gu;Ahn, Kyung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.141-149
    • /
    • 2004
  • In this study, smoke movement in tunnel fire with natural and longitudinal ventilation systems has been investigated. Reduced-scale experiments were carried out under the Froude scaling using 14.55kW fire source with a wick and experimental data is obtained with 1/18 model tunnel test. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gas was measured at emergency exit point. The results show that refuge time for 225m intervals of emergency exit in case of natural ventilation systems is 256 seconds and critical velocity for sufficient back-layer prevention is 2.8m/s for fire strength of 20MW.

  • PDF

Effect of Tobacco Smoke Solution on Mitotic Abnnormalities in Root Tip Cells of Allium cepa L. (양파 근단 세포의 유사분열에 미치는 담배연기 수용액의 영향)

  • 소웅영
    • Journal of Plant Biology
    • /
    • v.37 no.1
    • /
    • pp.69-76
    • /
    • 1994
  • The present work was conducted to examine the effect of tobacco smoke solution, and its components such as nicotine and catechol treated separately on the root tip cells of Allium cepa L The mitotic abnormalities in root tip cells treated with those three components were increased linearly, while the mitotic index was decreased following concentrations of the components. Chromosomal abnormalities showed 29.7%, 15.8% and 13.0% in the treatment of tobacco smoke solution, nicotine, and catechol, respectively. The abonormalities were included polyploid, c-mitosis, stickness at metaphase, laggard, bridge formation at anaphase or telophase, and micronucleus, abnormal nucleus at interphase, after the treatment of the components for 24 hours. hours.

  • PDF

PWR 불시정지시 냉각재화학 변화에 따른 화학제어 방향 도출

  • 성기웅;나정원;구제휴;성기방;강덕원;정홍호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.357-362
    • /
    • 1997
  • PWR 원전 계획 예방정비 기간 중에는 Crud 제거를 위한 정지화학 제어가 수행되고 있으나, 불시정지시 화학제어에 대한 접근은 거의 전무하다. 이에, 정지시 냉각재화학 변화에 따른 Nickel Ferrite의 안정성에 대해 검토하고, 불시정지시 냉각재 화학제어의 방향을 도출하였다. 계획정지 화학제어가 가능한 불시정지시에는 Nickel Ferrite 용출 증대를 위한 조기 붕산화와 고농도 용존수소 (Fig. 1 참조) 유지 및 산성-산화 단계의 도입이, 적용이 불가능한 경우에는 Nickel Ferrite 용출 억제를 위한 붕산화 연기 및 용존수소의 저농도 유지가 타당할 것이다.

  • PDF

A Numerical Study of Smoke Movement with Radiation in Atrium Fires (아트리움에서 화재 발생시 복사가 고려된 연기거동에 대한 수치해석 연구)

  • 정진용;유홍선;홍기배
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.7-15
    • /
    • 2001
  • This paper describes the smoke filling process of a fire field model based on a self-developed SMEP (Smoke Movement Estimating Program) codo to the simulation of fire induced flows in the atrium space (SIVANS atrium at Japan) containing smoke radiation effect. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy term. Also it solves the radiation equation using the discrete ordinates method. The result of the calculated smoke temperature containing radiation effect has shown a better prediction than the result calculated by only convection effect in comparison with the experimental data. This seems to come from the radiation effect of $H_2$O and $CO_2$ gas under smoke productions. Thus, the consideration of the radiation effect under smoke in fire should be necessary in order to get more realistic result. Also the numerical results indicated that the smoke layer is developing at a rate of about 0.1 m/s. It would take about 450 seconds after starting the ultra fast fire of 560 kW that the smoke layer move down to 1.5m above the escape level.

  • PDF

A Study on the Toxic Gases and Smoke Hazard of PASCON Trough (파스콘 트로프의 연기유독성에 관한 연구)

  • Lee, Chang-Woo;Hyun, Seong-Ho;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research is to estimate the effect of smoke and combustion gases on humane body indirectly through measuring the toxicity of those. For this purpose, the toxic index of smoke and combustion gases was investigated by smoke hazard test and analysis of smoke which were conducted by KS F 2271 and NES 713 method respectively. It i s proved by KS F 2271 method that PASCON trough is suitable to the testing standard of interior material and construction of building. In addition, it is identified by NES 713 method that combustion gases occurring in PASCON product were only carbon dioxide and carbon monoxide, and the smoke index of those was 0.944. This value means that the hazard effect of smoke gases on humane ! body can possibly happens when exposed to the smoke gases for more than 30 min. In aspect of the domestic situation that have not regulated the hazard estimation and the emissions of smoke when the flame retarding ability of the products have been requested, the toxic indexes of PASCON products are comparatively low.

Smoke Characteristics of a Small Scale Pool Eire (작은 풀화재에서의 연기 특성)

  • Lee Eui-Ju;Ahn Chan-Sol;Shin Hyun-Joon;Oh Kwang-Chul;Lee Uen-Do
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.58-63
    • /
    • 2005
  • Experimental measurements of flames and the product properties were performed for small kerosene pool fires. which is widely used as a fire source of laboratory scale experiments with scaling modeling. The flame length and flickering frequency were investigated for the flame structures, and compared with the theory. Three measurement methods were introduced to clarify the smoke characteristics, i.e. various gas concentrations, smoke density and thermophoretic sampling with transmission electron microscopy (TEM). The yield of carbon dioxide and the consumption of oxygen were proportional to the heat release rate of pool fires, but there is no trend on carbon monoxide emission. Smoke density of turbulent flames was exponentially increased with the heat release rate. The morphology of the soot particle was investigated to address the degree of soot maturing. The results show that the similar smoke morphology between an inverse jet flame and a pool fire exists despite of different combustion controlling mechanisms.

A Numerical Study for Fire Safety Evaluation of the Multi-story Residential Buildings -The Effects of the Openings of Stairwell on Fire Characteristics- (다세대주택의 화재안전평가에 대한 수치해석 연구 -계단실 개구부의 개폐가 화재특성에 미치는 영향-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.15-23
    • /
    • 2007
  • In the events of a fire in the residential building, highly flammable polyurethane foam sofa produce toxic smokes. In this type of fire, the residents of the building can be gotten into the difficulties of evacuating from the fire places or may be to death due to a lot of hot toxic gases. In this study, CFD simulations were carried out to study the effects of the openings of stairwell on the fire characteristics of fire room and stairwell. Also, analysis of fire hazard based on the tenability limits of fire and FED(fractional effective dose) was performed to evaluate the life safety of the residents of the building. In the fire room, maximum temperature was about $290^{\circ}C$, maximum CO concentration was about 4,740 ppm, and the time to incapacitation of residents in fire room was about t=144 s. In the stairwell, temperature and CO concentration in the condition of openings to be open were even lower than those in it to be closed. Time to the tenability limit with respect to smoke visibility in the stairwell with openings, which was open, was shorter than that of it without openings to be open. It has been shown from this study that opening the stairwell openings is able to decrease the fire hazards to the life safety in the multi-story residential building fire.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Hypolipidemic Effect of Onion Peel Extract in Rats Exposed to Cigarette Smoke Extract with a High-Fat Diet (고지방식이를 섭취한 흡연 흰쥐모델에서 양파껍질 추출물의 혈액지질 대사 개선 효과)

  • Kim, Juyeon;Noh, Sang Kyu
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.2
    • /
    • pp.161-166
    • /
    • 2016
  • This study was designed to investigate whether or not onion peel extract can lower blood lipid levels in rats exposed to cigarette smoke (CS) extract with a high-fat diet. Initially, male Sprague-Dawley rats were housed individually in a stainless steel, wire-bottomed cage with free access to AIN-93G diet. Rats were weight-matched and assigned to the following five groups: 1) control rats (CT) fed standard AIN-93G diet alone, 2) control rats exposed to CS extract (CT+CS), 3) high-fat group (HF) fed standard AIN-93 diet supplemented with 3% lard and 0.2% cholesterol, 4) high-fat group exposed to CS extract (HF+CS) fed standard AIN-93 diet supplemented with 3% lard and 0.2% cholesterol plus CS extract, and 5) high-fat plus onion peel (OP) extract group exposed to CS extract (HF+CS+OP) fed standard AIN-93 diet supplemented with 3% lard, 0.2% cholesterol, and onion peel extract (20 mg/17 g diet) plus CS extract. Using this feeding protocol, all animals completely consumed their respective diets throughout the 6 week duration. Blood was collected via the orbital sinus at weeks 0, 3, and 6, following overnight food deprivation. OP extract feeding resulted in significant reductions in blood triglyceride, total cholesterol, and non-HDL-cholesterol. Further, serum activities of aspartate transaminase and alanine transaminase were significantly reduced by OP extract at 6 weeks. These results provide clear evidence that onion peel extract has a profound inhibitory effect on blood lipids in rats exposed to CS extract. These findings suggest that OP extract can be used as an effective means in alleviating the serum lipid concentration after CS exposure.