• Title/Summary/Keyword: 연구도구

Search Result 10,706, Processing Time 0.047 seconds

Developing and Applying the Questionnaire to Measure Science Core Competencies Based on the 2015 Revised National Science Curriculum (2015 개정 과학과 교육과정에 기초한 과학과 핵심역량 조사 문항의 개발 및 적용)

  • Ha, Minsu;Park, HyunJu;Kim, Yong-Jin;Kang, Nam-Hwa;Oh, Phil Seok;Kim, Mi-Jum;Min, Jae-Sik;Lee, Yoonhyeong;Han, Hyo-Jeong;Kim, Moogyeong;Ko, Sung-Woo;Son, Mi-Hyun
    • Journal of The Korean Association For Science Education
    • /
    • v.38 no.4
    • /
    • pp.495-504
    • /
    • 2018
  • This study was conducted to develop items to measure scientific core competency based on statements of scientific core competencies presented in the 2015 revised national science curriculum and to identify the validity and reliability of the newly developed items. Based on the explanations of scientific reasoning, scientific inquiry ability, scientific problem-solving ability, scientific communication ability, participation/lifelong learning in science presented in the 2015 revised national science curriculum, 25 items were developed by five science education experts. To explore the validity and reliability of the developed items, data were collected from 11,348 students in elementary, middle, and high schools nationwide. The content validity, substantive validity, the internal structure validity, and generalization validity proposed by Messick (1995) were examined by various statistical tests. The results of the MNSQ analysis showed that there were no nonconformity in the 25 items. The confirmatory factor analysis using the structural equation modeling revealed that the five-factor model was a suitable model. The differential item functioning analyses by gender and school level revealed that the nonconformity DIF value was found in only two out of 175 cases. The results of the multivariate analysis of variance by gender and school level showed significant differences of test scores between schools and genders, and the interaction effect was also significant. The assessment items of science core competency based on the 2015 revised national science curriculum are valid from a psychometric point of view and can be used in the science education field.

Role of Actigraphy in the Estimation of Sleep Quality in Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡증의 수면의 질 평가와 액티그라프의 역할)

  • Lee, Seung-Hee;Lee, Jin-Sung;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.2
    • /
    • pp.86-91
    • /
    • 2007
  • Background: Actigraphy is a reliable and valid method for assessing sleep in normal, healthy populations, but it may be less reliable and valid for detecting disturbed sleep in patients. In this study, we attempted to assess the utility of actigraphy in the estimation of sleep quality in patients with obstructive sleep apnea syndrome (OSAS), a major sleep disorder. Method: We analyzed the data of patients who underwent polysomnography (PSG) and actigraphy simultaneously for one night at the Center for Sleep and Chronobiology, Seoul National University Hospital from November 2004 to March 2006. Eighty-nine subjects with OSAS alone and 21 subjects with OSAS and periodic limb movement disorder (PLMD) were included for final data analyses between groups. Polysomnographic and actigraphic data were also compared. Results: In subjects with mild OSAS (RDI<15), modretae ($15{\leq}RDI$<30), and OSAS with PLMD, PSG and actigraphy did not show significant difference in total sleep time and sleep efficiency. However in severe ($30{\leq}RDI$) OSAS subjects, PSG and actigraphy showed significant difference in total sleep time and sleep efficiency. In all patients, no correlations were found between sleep parameters from PSG and from those using actigraphy. Conclusions: We suggest that in severe OSAS patients, PSG is the diagnostic tool. In mild and moderate cases, actigraphy might be used as a screening tool.

  • PDF

Some General Characteristics of the Abstracting Journals Published in Korea (한국초록집의 특성)

  • 최성진
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.7 no.1
    • /
    • pp.5-22
    • /
    • 1994
  • This paper attempts to define some general characteristics of the Abstracting Journals published in Korea as evidenced in those published during last ten years. This purpose is achieved by comparing the results of the two studies conducted by the author in 1984 and in 1994. Both studies were conducted to present the state of the art in the abstracting services in Korea. The major conclusions made in this paper are summarised as follows: (1) Researchers and professionals working in a small number of subject fields are benefited by the abstracting journals, which provide current-awareness services of recent achievements in research and development in Korea. Those in most of the fields have no abstracting journals of their own, and naturally they have no substantial abstract-ing services. Even many researchers and professionals in the fields that have some abstracting journals are not informed of research results in their fields because the abstracting journals are scattered in many narrow subjects and in many cases, the abstracting journals only cover publications in some specific forms and kinds. (2) Abstracting journals that cover more than two subject fields, which are supposed to be of more or less help to the researchers and professionals in the subject fields that have no abstracting journals published in their fields, have rapidly increased in number in the past ten years. Most of suh abstracting journals carry thesis and dissertation abstracts, and the rest, those of research papers published in specific places, in specific forms, by specific institutions, and of reports of research projects sponsored by specific foundations. These abstracting journals are not of the kind that comprehensively provide researchers in related fields with current awareness of publications of research results in Korea. (3) Most of the abstracting Journals existing in Korea are Published by institutions of higher education and research institutes, and the rest, by commercial publishers, industrial firms, libraries, information centres, government agencies, research foundations, learned societies, etc. Those which publish many titles are small in number and those publish one or two titles are large in number. The former is largely made up of institutions of higher education and research institutes. (4) The abstracting journals published in Korea are classified by type into those of dissertations, research papers, journal articles, patent specifications in that descending order. The fact that Master; and doctoral dissertation abstracts ate dominating in Korea is due to the irrational practice of publishing those abstracts at many different institutions. (5) Most of the abstracting journals existing in Korea are published by national or government-supported research institutes in order to publicise their own research outputs. Their coverage of literature is normally narrow, and naturally their value to users is limited. (6) Korean is the desirable language for the abstracting journals intended to be distributed within Korea. About half of the abstracting jornals published in Korea is printed in Korean and the other half, in foreign languages, and in Korean and in foreign languages together. All the abstracting journals in foreign languages are printed in English except one, which is printed in Japanese. (7) Some twenty per cent of the abstracting journals in Korea is published monthly, bimonthly, and quarterly. The others are published annually, biannually and irregularly. The latter may not function properly as a current-awareness tool due to long intervals between their issues. It is particularly undesirable that about half of the abstracting journals in Korea is published irregularly. Most of the abstracting journals published in Korea are distributed freely to individuals and institutions selected by the publishers. (8) The abstracting journals published by the use of computers increased drastically in the past ten years. The abstracting journals produced by the conventional type-setting method will possibly disappear in Korea in another ten years to come. Automation of the production of abstracting journals does not simply mean technical, economic improvement in publishing processes but availability of machine-readable databases that can be used for many other pur-poses, including generation of other bibliographical publications and provision of machine literature searching capabilities. Necessary steps should be taken for this important development immediately.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

A Comparative Study of Two Different Heel Lancet Devices for Blood Collection in Preterm Infants (미숙아에서 채혈을 위한 발뒤꿈치 천자시 두 종류 천자 기구의 비교)

  • Lim, Hyo-Bin;Rhu, Mi-Joo;Jung, Ji-Mi;Jeon, Ga-Won;Sin, Jong-Beom
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.239-244
    • /
    • 2010
  • Purpose: To evaluate two different heel lancet device in terms of pain response and success of the procedure in the preterm infants undergoing heel puncture. Methods: 100 preterm infants undergoing capillary blood gas analysis or capillary bilirubin monitoring underwent heel puncture, were randomly allocated to blood sampling from the heel with either a conventional manual lancet or an automatic incision device. Primary outcome measures included the Premature Infants Pain Profile (PIPP) score, total duration of procedure, number of heel puncture and number of bruise. The pain response was evaluated using PIPP score and the effectiveness was evaluated using three criteria: total duration of blood sampling, number of puncture, bruising of the heel or ankle. Statistical analysis was performed using the SPSS ver. 13.0 program. Difference between the groups were analysed with t test (continuous variables) and the Chi square test or Fisher test (categorical variables). Results: The mean PIPP score was 4.91 for the automatic lancet group compared with 5.84 for the conventional manual lancet group (P=0.0255).The number of pain scores above 7 during blood collection did not differ between two groups (P=0.2167). The procedure took less time to perform in the automatic lancet group (mean, 30.69 seconds) than in the conventional lancet group (mean, 48.92 seconds) (P<0.0001). Conclusion: This study demonstrated that the automatic lancet device causes less pain and a shorter procedure time than the conventional manual lancet in preterm infants undergoing heel puncture. On the basis of these results the automatic lancet device is very useful method for blood collection in preterm infants by heel puncture.

A marine deep-towed DC resistivity survey in a methane hydrate area, Japan Sea (동해의 메탄 하이드레이트 매장 지역에서의 해양 심부 견인 전기비저항 탐사)

  • Goto, Tada-Nori;Kasaya, Takafumi;Machiyama, Hideaki;Takagi, Ryo;Matsumoto, Ryo;Okuda, Yoshihisa;Satoh, Mikio;Watanabe, Toshiki;Seama, Nobukazu;Mikada, Hitoshi;Sanada, Yoshinori;Kinoshita, Masataka
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • We have developed a new deep-towed marine DC resistivity survey system. It was designed to detect the top boundary of the methane hydrate zone, which is not imaged well by seismic reflection surveys. Our system, with a transmitter and a 160-m-long tail with eight source electrodes and a receiver dipole, is towed from a research vessel near the seafloor. Numerical calculations show that our marine DC resistivity survey system can effectively image the top surface of the methane hydrate layer. A survey was carried out off Joetsu, in the Japan Sea, where outcrops of methane hydrate are observed. We successfully obtained DC resistivity data along a profile ${\sim}3.5\;km$ long, and detected relatively high apparent resistivity values. Particularly in areas with methane hydrate exposure, anomalously high apparent resistivity was observed, and we interpret these high apparent resistivities to be due to the methane hydrate zone below the seafloor. Marine DC resistivity surveys will be a new tool to image sub-seafloor structures within methane hydrate zones.

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

Levels of Barriers to Pain Management of Cancer Patients and their Nurses (암 환자와 간호사의 통증관리 장애정도)

  • Yoo, Yang-Sook;Lee, Won-Hee;Cho, Ok-Hee;Lee, So-Woo
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.2
    • /
    • pp.224-233
    • /
    • 2005
  • Purpose: This study was conducted to provide basic data for developing an effective strategy for cancer pain management by comparing the levels of barriers to pain management of metastatic or advanced cancer patient and their nurses. Methods: The subject of this study were 155 patients who were treated for metastatic or advanced cancer at one of three hospitals in Seoul from January 2004 to January 2005, and 153 nurses who take care of those patients. The levels of barriers to pain management were measured using a tool developed by Gunnarsdottir et al. (2002), 27 questions on a six point scale. The levels of stresses were measured using a tool modified from a stress response measurement reported by Goh Gyung-bong et al. (2000), 27 questions on a five point scale. The levels of barriers in cancer patients were analyzed using t-test and ANOVA, while the data obtained from patients and nurses were compared by t-test. Results: Higher levels of barriers to pain management were found in three groups: 'less than middle school,' 'not treated with anti-cancer chemotherapy,' and 'ECOG of 2.' The level (2.55) of barriers to pain management in the patient group was higher than that (1.76) of the nurse group. Both of the two groups had high levels of barriers in two variables: 'There is a danger of becoming addicted to pain medicine.' and 'Using pain medicine blocks your ability to know if you have any new pain.' There was not a significant difference in the levels of stresses between the two groups. Conclusion: It was found that, for effective cancer pain management practices, it would be necessary to provide cancer patients and their nurses with education and training about pain management and related barriers.

  • PDF

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

Polymorphism of Salmonella Strains Using Arbitrary-Primed Polymerase Chain Reaction (Arbitrary-Primed PCR 기법을 이용한 Salmonella 균의 다형성 분석)

  • Hwang, Eui-Kyung;Kim, Sang-Kyun;Kim, Yeon-Soo;Kim, Woo-Tea;Lee, Jeong-Koo
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.2
    • /
    • pp.191-199
    • /
    • 2002
  • In this study, eight primers were used to detect genetic variability and phylogenetic relationships among the eighteen Salmonella strains by the arbitrary-primed PCR(AP-PCR) techniques. Five strains of Salmonella typhimurium, four strains of S entertidis, three strains of S choleraeuis, three strains of S gallinarum and three strains of S pullorum were typed by AP-PCR. The number of AP-PCR bands detected per each primer varied from 39 to 52, with an average of 43.6. A total of 349 AP-PCR bands were generated and among them, 185 bands(53.0%) were polymorphic. Among the primers, GEN 703 and GEN 708 primer showed a high level of polymorphism with 0.682 and 0.676, respectively. But GEN 603, GEN 604 and GEN 607 primer showed a low level of polymorphism with 0.404, 0.460 and 0.472, respectively. Therefore, the these primers will be the most effective for AP-PCR analysis of Salmonella strains. The level of polymorphism of S typhimurium CU 2001(0.77) was similar to that of S typhimurium CU 2002(0.77) and lower than those of other strains such as S typhimurium CU 2003(0.63), S typhimurium ATCC 14028(0.50) and S typhimurium CU 2004(0.43). The level of polymorphism of S enteritidis ATCC 13076(0.83) was similar to that of S enteritidis CU 2005(0.83) and lower than those of other strains such as S enteritidis CU 2006(0.63) and S enteritidis CU 2007(0.58). The level of polymorphism of S choleraeuis CU 2009(0.67) was similar to that of S choleraeuis CU 2010(0.67) and higher than those of other strains such as S choleraeuis CU 2008(0.53). The level of polymorphism of S gallinarum CU 2011(0.70) was similar to that of S gallinarum CU 2012(0.70) and higher than those of other strains Such as S gallinarum ATCC 9184(0.60). The level of polymorphism of S pullorum CU 2013(0.80) was similar to that of S pullorum CU 2014(0.80) and higher than those of other strains such as S pullorum No 11(0.53). Therefore, the AP-PCR analysis will be used a powerful tool for estimating genetic variation and phylogenetic relationships among Salmonella strains.