• Title/Summary/Keyword: 연계/통합

Search Result 1,920, Processing Time 0.036 seconds

Development of Optimal Thermal Transfer Calculation Algorithm by Composition of Thermal Transfer Mechanism among Integrated Energy Operators (집단에너지 사업자간의 열연계 메커니즘 구성에 의한 최적 열연계 산정 알고리즘 개발)

  • Kim, Yongha;Kim, Seunghee;Hyeon, Seungyeon
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.57-66
    • /
    • 2017
  • Since the heat is not as fast as the electric power and the loss is relatively large compared to the electric power, it is not realistic to operate the thermal transfer system with on operation center like electric power trading. In the case of the Korea District Heating Corporation, where all the thermal transfer are currently being made, only two or four adjacent heat-generating power plants are being the heat trading. Therefore, In this paper, we concluded that it is appropriate to divide the integrated operation center for heat trading into several regions, to operate the hub integrated operation power plant in each region to reflect the characteristics of the heat medium and proposed the thermal transfer mechanism among integrated energy operators. Then, we have developed an algorithm that can optimize the heat transaction for the proposed mechanism and applied it to the actual operators to verify the usefulness of the proposed algorithm.

An Integrated Interface based on CIM between Energy Management System and Heterogeneous Systems (에너지 관리 시스템(EMS)과 이기종 시스템간 CIM 기반의 통합 인터페이스)

  • Kang, Dong Hyun;Lee, Yong Ik;Park, Jong Ho;Shin, Yong-Hack
    • Journal of Software Engineering Society
    • /
    • v.24 no.3
    • /
    • pp.111-115
    • /
    • 2011
  • With the emergence of the smart grid era, the interest in green energy which reduce carbon emissions and environment-friendly smart grid which combines the advantages of power and IT technology is increasing around the world. To use the smart grid effectively heterogeneous systems such as EMS, MOS and WIS must be linked together. However, additional interface should be developed to link EMS and heterogeneous systems since IEC has only defines the interface for EMS. Especially, to link legacy system and new system, some software might need to be designed and developed because separate interfaces for connection can be developed depending on each system and environment. In this paper, we propose an integrated interface based on CIM for interconnection between systems. A proposed interface can integrate messages of heterogeneous system and will be able to reduce costs that could be incurred by the removal of the existing system and the addition of the new system.

  • PDF

A Study on Integrated Fire Protection System for high-rise Building (초고층빌딩 통합 화재방재시스템 설계 및 구현에 관한 연구)

  • Lee, Jeong-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.39-47
    • /
    • 2020
  • The fire protection system for high-rise buildings is currently confined to the preparation of sprinklers, emergency stairs, and exit and monitoring systems. On the other hand, an integrated system, including the model with scenario-based actions, is required for effective fire protection. An integrated fire protection system is needed to operate and manage the total cycle of the fire protection. In this study, an integrated fire protection system, which included sensing and consequent processes related to fire emergencies, was designed and implemented. The designed scheme can gather and analyze the data of the production, operation, and consumption patterns as it integrates fire protection systems for fire fighters and evacuating people. The integrated fire protection technology and system, which has target performance with satisfied 1/2 sec transaction response time and 1.2 transactions per second, is expected to contribute to market creation in converged technology-based fire protection fields.

The Effectiveness of the Short-term Intensive Intervention Program: Case Report (감각통합기능장애 아동에게 적용한 단기집중치료프로그램의 효과)

  • Choi, Hyun-Ae;Kang, Eun-A
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.6 no.1
    • /
    • pp.25-33
    • /
    • 2008
  • Objective : To identify the effectiveness of a short-term intensive intervention program on the improvement of adaptive response of a child with mixed sensory integration disorder. Method : Four and half years old boy who has been diagnosed of PDD received 40 min of one intervention session and 50 min of 3 intervention sessions. The intervention was a part of the 2008 Sensory Integration Treatment Course developed by the Korean Academy of Sensory Integration (KASI) and all sessions were implemented under supervision by experts. Result : Adaptive responses of the child were enhanced throughout the intervention process in terms of postural response and peer interaction. His oral defensiveness is improved. As the intervention progressed, he exhibited more active movements, louder voice, and coherence within peer group. Conclusion : This case report demonstrates effectiveness of a short-term intensive intervention program in terms of improving adaptive response. To enrich the effectiveness, tt is suggested to educate parents about neurological base of the child's behaviors so the they understand the importance of various sensory experience within play.

  • PDF

Remediation of Arsenic Contaminated soils Using a Hybrid Technology Integrating Bioleaching and Electrokinetics (생용출과 전기동력학을 연계한 통합기술을 이용한 비소 오염 토양의 정화)

  • Lee, Keun-Young;Kimg, Kyoung-Woong;Kim, Soon-Oh
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.33-44
    • /
    • 2009
  • The objective of the study was to develop a hybrid technology integrating biological and physicochemical technologies to efficiently remediate arsenic contaminated lands such as abandoned mine area. The tailing soil samples contaminated with As at a high level were obtained from Songchon abandoned mine, and the content of arsenic and heavy metals as well as physicochemical properties and mineral composition were investigated. In addition, two sets of sequential extraction methods were applied to analyze chemical speciations of arsenic and heavy metals to expect their leachability and mobility in geoenvironment. Based on these geochemical data of arsenic and heavy metal contaminants, column-type experiments on the bioleaching of arsenic were undertaken. Subsequently, experiments on the hybrid process incorporating bioleaching and electrokinetics were accomplished and its removal efficiency of arsenic was compared with that of the individual electrokinetic process. With the results, finally, the feasibilty of the hybrid technnology was evaluated. The arsenic removal efficiencies of the individual electrokinetic process (44 days) and the hybrid process incorporating bioleaching (28 days) and electrokinetics (16 dyas) were measured 57.8% and 64.5%, respectively, when both two processes were operated in an identical condition. On the contrary, the arsenic removal efficiency during the bioleaching process (28 days) appeared relatively lower (11.8%), and the result indicates that the bioleaching process enhanced the efficacy of the electrokinetic process as a result of mobilization of arsenic rather than removed arsenic by itself. In particular, the arsenic removal rate of the electrokinetics integrated with bioleaching was observed over than 2 times larger than that obtained by the electrokinetics alone. From the results of the study, if the bioleaching which is considered a relatively economic process is applied sufficiently prior to electrokinetics, the removal efficiency and rate of arsenic can be significantly improved. Consequently, the study proves the feasibility of the hybrid process integrating both technologies.