Heating and Cooling Energy Demand Analysis of Standard Rural House Models (농어촌 주택 표준모델의 냉난방에너지요구량 분석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3307-3314
    • /
    • 2012
  • The annual energy demand of the standard rural house models was analyzed using the DesignBuilder. Indoor temperature set-point, U-value of outer wall, type of window, and degree of ventilation were selected as simulation parameters. In all the simulation cases, heating energy demand was higher than cooling energy demand regardless of the building size. When the lower U-value of the outer wall was applied to account for the thicker insulation layer, heating energy demand was decreased while cooling energy demand was increased. However, it is better to reduce the area of outer wall which is directly exposed to outdoor air because reducing the U-value of the outer wall is not effective in decreasing heating energy demand. Among the four different window types, the double skin window is most favorable because heating energy demand is the lowest. For a fixed infiltration rate, higher ventilation rate resulted in an increased heating energy demand and had minor impact on cooling energy demand. As long as the indoor air quality is acceptable, lower ventilation rate is favorable to reduce the annual energy demand.

A Study on Standard Heating and Cooling Load according to Design Factors using Prototypical Load Model (표준부하모델을 이용한 설계 변수에 따른 표준부하량 분석)

  • Kim, Kwonye;Bae, Sangmu;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • Before newly-built building and building remodeling, it is important to predict and analyze building energy performance through energy simulation programs. Nevertheless, simulation results widely vary depending on individual user experience and input values. Therefore, this study uses prototypical building model, a versatile tool in building energy modeling, simulation and research for researchers and policy-makers, and ASHRAE standards. Then, it analyzed the changes in design type (roof type, number of floors) for the base case. As the result, it was found that the gap of annual energy demand per between them is maximally 9.1%.

Improvement of Energy Efficiency in Wood Frame House with Energy Efficient Methods (건물 에너지 절약요소 적용을 통한 목조주택의 에너지 성능 개선)

  • Kim, Sejong;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.77-86
    • /
    • 2013
  • This research was carried out to evaluate and raise the energy efficiency of wood frame house. The commercial solution program CE3 (Construction Energy Efficiency Evaluation) was used for simulating the energy consumption in the single-family wood frame house. The results showed that the annual heating energy demand of the house was 160 kWh per 1 $m^2$ floor area. In order to decrease the heating energy demand, the following energy efficiency methods were applied to the simulation : a) simplification of building shape, b) decrease of windows area, c) application of high performance windows (with low thermal transmittance) and d) application of heat recovery ventilator. In case of replacement of the windows with high performance one with thermal transmittance 1 $W/m^2{\cdot}K$, the lowest heating demand of 80 $kWh/m^2{\cdot}a$ was obtained. The best combination of methods, application of high performance windows and heat recovery ventilator, showed heating energy demand 34.5 $kWh/m^2{\cdot}a$.

반도체 공정의 배기계통 및 진공펌프 실시간 상태진단기술 개발

  • Choe, Gyeong-Min;Song, Gyeong-Ho;Park, Sang-Hyeon;Gang, Min-Ho;Im, Seong-Gyu;Gang, Sang-U;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.101.2-101.2
    • /
    • 2015
  • 급속한 산업화로 인하여 에너지 부족 문제가 대두되고 있는 가운데 에너지 저감 기술의 개발이 요구되고 있다. 국내 반도체 공정의 배기계통에서 소비되는 에너지는 전체 공정에 소비되는 에너지중 상당량에 달하며 10%의 에너지 절감은 연간 1000억원 이상의 비용절감 효과를 기대할 수 있다. 반도체 공정 배기계통은 진공펌프의 특성, 챔버의 부피, 도관의 구조(직경, 길이, 형상), 진공재료의 기체방출 등 여러 가지 요소의 복합적인 영향으로 그 상태가 달라지므로 보다 효과적인 공정의 운용과 에너지 절감을 위해 반도체 공정의 복합 상태 진단기술 개발이 요구되고 있으며 그중 큰 비중을 차지하는 드라이펌프의 실시간 모니터링 기술의 개발이 시급하다. 본 연구에서는 반도체 공정의 복합 상태 진단기술 개발에 대한 기초 연구로서 반도체 공정 배기계통의 conductance 및 유량 변화에 대한 드라이펌프의 특성을 이론적 계산으로 얻어진 결과와 실험을 통하여 얻어진 결과를 비교, 분석하였다. 진공펌프의 기본 특성은 한국표준과학연구원에서 국제규격에 따라 도달진공도, 배기속도, 소비전력, gas load, 소음, 진동 등을 분석하였고, 나노종합기술원의 PECVD 장비(chamber A: amorphous silicon 및 loadlock chamber)에 챔버의 부피, 도관의 구조, 공정가스의 유량 등을 측정하여 simulation 하였으며, 실제 측정값은 LabVIEW 프로그래밍으로 자동화 된 MFC를 이용하여 실제 공정 상태를 모사하였다. 실험은 PECVD의 특성을 고려하여 질소분위기에서 CDG (Capacitance Diaphragm Gauge)를 사용하였다.

  • PDF

Hydrologic Performance Characteristics of Small Hydropower Resources with Rainfall Condition (강우상태에 따른 소수력자원의 수문학적 특성 분석)

  • Lee, Chulhyung;Park, Wansoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.207.2-207.2
    • /
    • 2011
  • 소수력자원의 개발을 위해서는 소수력발전입지에 대한 설계변수의 분석이 매우 중요하다. 설계변수는 해당유역의 강우사상과 밀접한 관계가 있으므로 이에 대한 정량적인 분석이 요구된다. 본 연구에서는 수계별 소수력발전입지에 대하여 설계변수의 특성을 분석하였다. 분석결과, 금강수계, 남한강수계 및 섬진강수계는 유역면적이 증가하여도 비가용량의 변화가 크지않지만, 낙동강수계와 북한강수계는 유역면적의 크기에 관계없이 비가용량의 변화가 크게 나타났다. 또한 비출력량의 경우에도 비가용량과 유사하게 금강수계, 남한강수계 및 섬진강수계는 유역면적이 증가하여도 비출력량의 변화가 크지않지만, 낙동강수계와 북한강수계는 유역면적의 크기에 관계없이 비출력량의 변화가 크게 나타났다. 이러한 현상은 우리나라의 연강수량이 남부지방이 중부지방에 비하여 많기 때문으로 판단된다. 낙동강수계는 하도가 남북으로 길기 때문에 소수력발전입지의 위치에 따라 비가용량의 크기의 변화가 크고, 북한강수계도 이와 비슷한 경향을 갖는다. 반면에 금강수계, 남한강수계 및 섬진강수계는 하도가 동서방향으로 길기 때문이다. 또한 연간가동율의 경우에는 모든 수계에 대하여 변화가 크지 않았고, 유역면적의 변화에 대해서도 큰 변화가 없었다.

  • PDF

Study for Clean Energy Farming System by Mass and Energy Balance Analysis in the Controlled Cultivation of Vegetable Crop (Cucumber) (물질 및 에너지 수지 분석을 통한 시설채소(오이)의 청정에너지 농업 시스템 구축을 위한 기초 연구)

  • Shin, Kook-Sik;Kim, Seung-Hwan;Oh, Seong-Yong;Lee, Sang-En;Kim, Chang-Hyun;Yoon, Young-Man
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.280-286
    • /
    • 2012
  • Clean energy farming is the agricultural activity to improve an efficiency of agricultural energy use and to replace fossil fuels. This study was carried out to establish the clean energy farming system in the controlled cultivation of vegetable crop (cucumber) adopting the biogas production facility. In order to design the clean energy farming system, mass and energy balance was analyzed between the controlled cultivation system and the biogas production facility. Net yearly heating energy demands ($E_{YHED}$) of forcing and semi-forcing cultivation types were 48,697 and $13.536Mcal\;10^{-1}$ in the controlled cultivation of vegetable cucumber. To cover these $E_{YHED}$, the pig slurry of 511 and $142m^3\;10a^{-1}$ (biogas volume of 9,482 and $2,636Nm^3\;10a^{-1}$, respectively, as 60% methane content) were needed in forcing and semi-forcing cultivation types. The pig slurry of $511m^3\;10a^{-1}$ caused N 1,788, $P_2O_5$ $511kg\;10a^{-1}$ in the forcing cultivation type, and the pig slurry of $142m^3\;10a^{-1}$ caused N 497, $P_2O_5$ $142kg\;10a^{-1}$ in the semi-forcing cultivation type. The daily heating energy demand ($E_{i,DHED}$) by the time scale analysis showed the minimum $E_{i,DHED}$ of $7.7Mcal\;10a^{-1}\;day^{-1}$, the maximum $E_{i,DHED}$ of $515.1Mcal\;10a^{-1}\;day^{-1}$, and the mean $E_{i,DHED}$ of 310.2 in the forcing cultivation type. And the minimum $E_{i,DHED}$, the maximum $E_{i,DHED}$, and the mean $E_{i,DHED}$ were 5.3, 258.0, and $165.1Mcal\;10a^{-1}\;day^{-1}$ in the semi-forcing cultivation type, respectively. Input scale of biogas production facility designed from the mean $E_{i,DHED}$ were 3.3 and $1.7m^3\;day^{-1}$ in the forcing and the semi-forcing cultivation type. The maximum $E_{i,DHED}$ gave the input scale of 5.4 and $2.7m^3\;day^{-1}$ in the forcing and the semi-forcing cultivation type.

수치모형실험을 활용한 조류발전단지의 후류 특성에 관한 연구

  • Jeong, Hae-Chang;Kim, Bu-Gi;Kim, Jun-Ho;Yang, Chang-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.193-194
    • /
    • 2018
  • 최근 정부의 RPS(신재생에너지 의무할당제, Renewable Energy Portplio Standard) 확대 시행과 신재생 3020 정책에 맞물려 정부뿐만 아니라 기업체의 신재생에너지 발전설비용량과 발전량의 확대가 요구되는 시점이다. 특히 조류에너지는 환경친화적이며 지속가능한 에너지원으로서 그 관심이 더욱 커지고 있다. 그러나 조류발전 후보지는 유속이 매우 빠르고, 설치가 어려워 그에 따른 제반사항들이 다른 에너지원에 비해 상대적으로 많다는 단점이 있어, 조류발전단지 구축 시에는 후보지를 선정하고 타당성 조사를 수행하는 과정이 매우 중요하다. 따라서 본 논문에서는 최대의 조류에너지를 얻을 수 있는 해역을 선정하여 조류발전단지를 설계하고 후류의 특성을 분석하였다. 먼저 전자해도의 상세 수심 자료를 추출해 상용 프로그램인 ADCIRC 프로그램에 실제 지형을 수치 모형화하였고, 잠재적 에너지 분포가 높은 해역에 1MW급 수평축 조류발전 터빈을 설계하여 적용하였다. 또한 조류발전단지 내의 터빈의 배치 방법(Centered, Staggered Layout)에 따른 후류의 특성을 분석하여 연간 전력 생산량을 계산하였다.

  • PDF

Evaluation of Power Generation Efficiency according to Geometric Characteristics of Reservoir in Micro Vortex Hydro-electric Power Generation System (마이크로 보텍스 수력발전시스템에 있어 저수조의 기하학적 특성에 따른 발전 효율 평가)

  • Jeong, Woo Chang;Kang, Hyun Sil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.432-432
    • /
    • 2021
  • 우리나라는 대부분의 에너지 공급을 해외에 의존하고 있는 실정이다. 산업통상자원부와 에너지경제연구원에서 발간하는 2018년 에너지통계연보(에너지경제연구원과 산업통상자원부, 2018)에 실린 2010년부터 2017년까지의 에너지수급 균형을 보면 원유, 천연가스, 석탄, 우라늄 등 평균 95.4%의 에너지를 수입하고 있는 실정이다. 수력 및 신재생에너지의 경우 기후변화에 대응하는 수단 그리고 정부의 저탄소에너지 전환 정책으로 인정받아 상대적으로 낮은 에너지 경제성에도 불구하고 꾸준히 보급되고 있다. 우리나라뿐만 아니라 독일, 프랑스, 영국, 중국 그리고 인도와 같은 세계 주요 국가들이 친환경 에너지 정책을 주도함에 따라 향후 신재생에너지의 공급 규모는 크게 확대될 것으로 전망된다. 중력 물 보텍스 마이크로 수력 발전 시스템은 시스템의 상하류부의 수두(hydraulic head) 차에 의해 저류조(basin)에서 발생되는 물의 보텍스 즉 소용돌이(whirlpool)를 이용하여 임펠러(impeller)를 회전시켜 전기에너지를 생산하는 친환경적 재생에너지의 일종이다. 또한, 시스템으로 유입되는 물은 전기에너지 생산을 위한 임펠러를 통과한 후 다시 하천으로 방류되므로 하천 수의 손실 그리고 하천의 물길도 거의 교란 시키지 않는다. 4가구 정도의 연간 가정용 전기 요구량인 12와 15kW 사이의 전기에너지를 생산하기 위해서는 발전시스템의 상류와 하류의 수두차가 단지 1.5에서 1.7m 이하이면 충분한 것으로 알려져 있다. 본 연구에서는 중력 물 보텍스 친환경 마이크로 발전 시스템을 구성하는 저류조(basin)에 대해 최대 발전효율을 발생시키기에 최적인 기하학적 형태를 도출하는 것이며, 이를 위해 저류조의 cone angle에 따른 다양한 저류조 직경 및 물 보텍스 생성을 위한 저류조 형태의 변화, 유입수로와 저류조와의 각도인 notch angle의 변화, 유입부 폭과 유출부 직경, 유입수로의 길이 그리고 유입수로에서의 초기수심과 같은 기하학적 매개변수를 변화시켜 모의를 수행하였다.

  • PDF

A Rough Estimation of Environmental Capacity in the Yellow Sea using a Numerical Hydrodynamic Model (해수운동모델을 이용한 황해 환경용량의 개략 산정)

  • Kim Gwang Su;Kim Dong Myung;Park Chung Kil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.1
    • /
    • pp.63-73
    • /
    • 1999
  • The results of residual currents simulation by a three-dimensional hydrodynamic model showed the water volume transport and the residence time to be about 4km³ per tidal cycle and about 6 years through the line of latitude, 34° 25' N in the Yellow Sea, and to be about 13km³ per tidal cycle and about 2.5 years through the southeastern boundary line of the Yellow Sea, respectively. On the bases of the entire seawater volume of the Yellow Sea and dissolved oxygen (DO) in summer, the environmental capacity of the Yellow Sea for reception of the maximum pollution load without reducing DO concentration below 5.0mg/ℓ in seawater may be estimated to be about 58×10/sup 6/tons of chemical oxygen demand (COD), which is equivalent to the load about 8 times as high as the annual organic pollution load from 14 major rivers. On the bases of DO transports by residual currents calculated on the line of 34° 25' N latitude and on the southeastern boundary line of the Yellow Sea being about 57×10³tons and about 203×10³tons of DO per day, respectively, the environmental capacities of the Yellow Sea for reception of the maximum pollution loads without reducing DO concentration in seawater nay be equivalent to COD loads about 3 times and 10 times, respectively, as high as the existing organic pollution loads from 14 major rivers.

  • PDF

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (지열원 멀티열펌프 시스템의 용량가변 특성 연구)

  • Cho, Chanyong;Oh, Myung Suk;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.120-120
    • /
    • 2010
  • 에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.

  • PDF