• Title/Summary/Keyword: 역치

Search Result 423, Processing Time 0.035 seconds

Barrier Techniques for Spinal Cord Protection from Thermal Injury in Polymethylmethacrylate Reconstruction of Vertebral Body : Experimental and Theoretical Analyses (Polymethylmethacrylate를 이용한 척추체 재건술에서 척수의 열 손상을 방지하기 위한 방어벽 기법 : 실험적 및 이론적 분석)

  • Park, Choon Keun;Ji, Chul;Hwang, Jang Hoe;Kwun, Sung Oh;Sung, Jae Hoon;Choi, Seung Jin;Lee, Sang Won;Park, Sung Chan;Cho, Kyeung Suok;Park, Chun Kun;Yuan, Hansen;Kang, Joon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.272-277
    • /
    • 2001
  • Objective : Polymethylmethacrylate(PMMA) is often used to reconstruct the spine after total corpectomy, but the exothermic curing of liquid PMMA poses a risk of thermal injury to the spinal cord. The purposes of this study are to analyze the heat blocking effect of pre-polymerized PMMA sheet in the corpectomy model and to establish the minimal thickness of PMMA sheet to protect the spinal cord from the thermal injury during PMMA cementation of vertebral body. Materials & Methods : An experimental fixture was fabricated with dimensions similar to those of a T12 corpectomy defect. Sixty milliliters of liquid PMMA were poured into the fixture, and temperature recordings were obtained at the center of the curing PMMA mass and on the undersurface(representing the spinal cord surface) of a prepolymerized PMMA sheet of variable thickness(group 1 : 0mm, group 2 : 5mm, or group 3 : 8mm). Six replicates were tested for each barrier thickness group. Results : Consistent temperatures($106.8{\pm}3.9^{\circ}C$) at center of the curing PMMA mass in eighteen experiments confirmed the reproducibility of the experimental fixture. Peak temperatures on the spinal cord surface were $47.3^{\circ}C$ in group 2, and $43.3^{\circ}C$ in group 3, compared with $60.0^{\circ}C$ in group 1(p<0.00005). So pre-polymerized PMMA provided statistically significant protection from heat transfer. The difference of peak temperature between theoretical and experimental value was less than 1%, while the predicted time was within 35% of experimental values. The data from the theoretical model indicate that a 10mm barrier of PMMA should protect the spinal cord from temperatures greater than $39^{\circ}C$(the threshold for thermal injury in the spinal cord). Conclusion : These results suggest that pre-polymerized PMMA sheet of 10mm thickness may protect the spinal cord from the thermal injury during PMMA reconstruction of vertebral body.

  • PDF

Interaction between Pain Aspect and Sleep Quality in Patients with Temporomandibular Disorder (측두하악장애 환자에서의 통증양상과 수면과의 관계)

  • Tae, Il-Ho;Kim, Seong-Taek;Ahn, Hyung-Joon;Kwon, Jeong-Seung;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.2
    • /
    • pp.205-218
    • /
    • 2008
  • Interaction between pain and sleep has long been proved through many researches, and various studies are being conducted to identify its mechanism. However, these studies have targeted on patients with systemic disease, such as rheumatic disease and fibromyalgia. There are few researches on patients with orofacial pain including temporomandibular disorder(TMD). In this study, we studied interaction between pain aspect and sleep quality in 229 patients with TMD, who visited the TMJ and Orofacial pain clinic. Pittsburgh Sleep Quality Index(PSQI), Epworth sleepiness scale(ESS) questionnaire were surveyed and sleep-screening device was operated. PSQI showed that sleep quality in TMD patients with pain was poorer than that in TMD patients without pain. The ratio of poor sleeper was higher in TMD patients with pain. Especially, TMD patients with chronic pain showed obviously poorer sleep quality than TMD patients with acute pain. The result of ESS showed that patients with painful TMD showed more daytime sleepiness than painless TMD patients. The ratio of TMD patients with chronic pain who had daytime sleepiness was higher than TMD patients with acute pain, and the amount of daytime sleepiness was higher in the group of chronic pain. In TMD patients with chronic pain, only the poor sleeper(PSQI>5) presented mean ESS>10(diagnostic criteria of daytime sleepiness). There was no correlation between pain intensity and sleep quality or daytime sleepiness. The result of ApnealinkTM for screening of sleep related breathing disorder showed that only 1 patient presented AHI>5 among 19 participants. TMD patients with chronic pain presented poor sleep quality and excessive daytime sleepiness similar to other chronic pain patients. Evaluation of sleep state by questionnaire might be useful for diagnosis and management of TMD, because sleep disturbance decreases pain threshold and pain disturbs sleep. In addition, sleep-screening device would be useful for screening sleep related breathing disorder in dental clinic.

A Methodology of Ship Detection Using High-Resolution Satellite Optical Image (고해상도 광학 인공위성 영상을 활용한 선박탐지 방법)

  • Park, Jae-Jin;Oh, Sangwoo;Park, Kyung-Ae;Lee, Min-Sun;Jang, Jae-Cheol;Lee, Moonjin
    • Journal of the Korean earth science society
    • /
    • v.39 no.3
    • /
    • pp.241-249
    • /
    • 2018
  • As the international trade increases, vessel traffics around the Korean Peninsula are also increasing. Maritime accidents hence take place more frequently in the southern coast of Korea where many big and small ports are located. Accidents involving ship collision and sinking result in a substantial human and material damage as well as the marine environmental pollution. Therefore, it is necessary to locate the ships quickly when such accidents occur. In this study, we suggest a new ship detection index by comparing and analyzing the reflectivity of each channel of the Korea MultiPurpose SATellite-2 (KOMPSAT-2) images of the area around the Gwangyang Bay. A threshold value of 0.1 is set based on a histogram analysis, and all vessels are detected when compared with RGB composite images. After selecting a relatively large ship as a representative sample, the distribution of spatial reflectivity around the ship is studied. Uniform shadows are detected on the northwest side of the vessel. This indicates that the sun is in the southeast, the azimuth of the actual satellite image is $144.80^{\circ}$, and the azimuth angle of the sun can be estimated using the shadow position. The reflectivity of the shadows is 0.005 lower than the surrounding sea and ship. The shadow height varies with the position of the bow and the stern, perhaps due to the relative heights of the ship deck and the structure. The results of this study can help search technology for missing vessels using optical satellite images in the event of a marine accident around the Korean Peninsula.

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image (Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성)

  • Moon, A-Reum;Chi, Yong-Gi;Choi, Sung-Wook;Lee, Hyuk;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Purpose: PET/CT combines functional and morphologic data and increases diagnostic accuracy in a variety of malignancies. Especially reconstructed Fusion PET/CT images or MIP (Maximum Intensity Projection) images from a 2-dimensional image to a 3-dimensional one are useful in visualization of the lesion. But in Fusion & MIP 3D reconstruction image, due to hot uptake by urine or urostomy bag, lesion is overlapped so it is difficult that we can distinguish the lesion with the naked eye. This research tries to improve a distinction by removing parts of hot uptake. Materials and Methods: This research has been conducted the object of patients who have went to our hospital from September 2008 to March 2009 and have a lot of urine of remaining volume as disease of uterus, bladder, rectum in the result of PET/CT examination. We used GE Company's Advantage Workstation AW4.3 05 Version Volume Viewer program. As an analysis method, set up ROI in region of removal in axial volume image, select Cut Outside and apply same method in coronal volume image. Next, adjust minimum value in Threshold of 3D Tools, select subtraction in Advanced Processing. It makes Fusion & MIP images and compares them with the image no using Region Cut Definition. Results: In Fusion & MIP 3D reconstruction image, it makes Fusion & MIP images and compares them by using Advantage Workstation AW4.3 05's Region Cut Subtraction, parts of hot uptake according to patient's urine can be removed. Distinction of lesion was clearly reconstructed in image using Region Cut Definition. Conclusion: After examining the patients showing hot uptake on account of volume of urine intake in bladder, in process of reconstruction image, if parts of hot uptake would be removed, it could contribute to offering much better diagnostic information than image subtraction of conventional method. Especially in case of disease of uterus, bladder and rectum, it will be helpful for qualitative improvement of image.

  • PDF

Diagnosis and Post-Therapeutic Evaluation of Arteriovenous Malformations in Extremities Using Transarterial Lung Perfusion Scintigraphy (경동맥 폐관류 신티그라피를 이용한 상하지 동정맥 혈관기형의 진단과 치료 평가)

  • Chung, Hyun-Woo;Choi, Joon-Young;Kim, Young-Wook;Kim, Dong-Ik;Do, Young-Soo;Lee, Eun-Jeong;Lee, Su-Jin;Cho, Young-Seok;Hyun, Seung-Hyup;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.316-321
    • /
    • 2006
  • Purpose: Differential diagnosis between arteriovenous (AVMs) aud non-arteriovenous malformations (nAVMs) is important in patients with congenital vascular malformations, because AVMs can cause hemodynamic alteration and require immediate treatment. We investigated whether transarterial lung perfusion scintigraphy (TLPS) was useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities. Materials and Methods: Fifty-seven patients (M:F=26:31, $21{\pm}13$ yr, 9 upper and 48 lower extremities) suspected of congenital vascular malformations in extremities underwent TLPS using $^{99m}Tc-MAA$ before embolization/sclerotherapy. Dose-corrected shunt fraction (SF) was calculated from time-activity curve of the lung. Final diagnosis of AVMs was determined by angiography. in patients with AVMs, follow-up TLPS was done for post-therapeutic evaluation. Results: Sixteen patients (8 upper and 8 lower extremities) had AVMs, while the remaining 41 had nAVMs (1 upper and 40 lower extremities). The mean SF of AVMs on TLPS was significantly higher than that of nAVMs ($66.4{\pm}25.8%\;vs.\;2.8{\pm}4.3%$), p=0.003). The sensitivity, specificity, and accuracy of TLPS (cut-off of SF = 20.0%) in diagnosis of AVMs before treatment were 93.8% (15/16), 100% (41/41) and 98.2% (56/57), respectively. The follow-up TLPS and angiography for post-therapeutic evaluation showed concordant results in 13 of 16 patients (81.3%) with AVMs. The mean SF of TLPS was significantly decreased after embolization/sclerotherapy ($69.5{\pm}24.0%\;vs.\;41.0{\pm}34.7%$, p=0.01). Conclusion: TLPS provides hemodynamic information of AVMs in extremities semiquantitatively. Furthermore, the results of TLPS showed a high concordance rate with angiographic findings. Therefore, TLPS is useful for the diagnosis and post-therapeutic evaluation of AVMs in extremities.

Development of Automated Region of Interest for the Evaluation of Renal Scintigraphy : Study on the Inter-operator Variability (신장 핵의학 영상의 정량적 분석을 위한 관심영역 자동설정 기능 개발 및 사용자별 분석결과의 변화도 감소효과 분석)

  • 이형구;송주영;서태석;최보영;신경섭
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The quantification analysis of renal scintigraphy is strongly affected by the location, shape and size of region of interest(ROI). When ROIs are drawn manually, these ROIs are not reproducible due to the operators' subjective point of view, and may lead to inconsistent results even if the same data were analyzed. In this study, the effect of the ROI variation on the analysis of renal scintigraphy when the ROIs are drawn manually was investigated, and in order to obtain more consistent results, methods for automated ROI definition were developed and the results from the application of the developed methods were analyzed. Relative renal function, glomerular filtration rate and mean transit time were selected as clinical parameters for the analysis of the effect of ROI and the analysis tools were designed with the programming language of IDL5.2. To obtain renal scintigraphy, $^{99m}$Tc-DTPA was injected to the 11 adults of normal condition and to study the inter-operator variability, 9 researchers executed the analyses. The calculation of threshold using the gradient value of pixels and border tracing technique were used to define renal ROI and then the background ROI and aorta ROI were defined automatically considering anatomical information and pixel value. The automatic methods to define renal ROI were classified to 4 groups according to the exclusion of operator's subjectiveness. These automatic methods reduced the inter-operator variability remarkably in comparison with manual method and proved the effective tool to obtain reasonable and consistent results in analyzing the renal scintigraphy quantitatively.

  • PDF

Development of Acquisition and Analysis System of Radar Information for Small Inshore and Coastal Fishing Vessels - Suppression of Radar Clutter by CFAR - (연근해 소형 어선의 레이더 정보 수록 및 해석 시스템 개발 - CFAR에 의한 레이더 잡음 억제 -)

  • 이대재;김광식;신형일;변덕수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.347-357
    • /
    • 2003
  • This paper describes on the suppression of sea clutter on marine radar display using a cell-averaging CFAR(constant false alarm rate) technique, and on the analysis of radar echo signal data in relation to the estimation of ARPA functions and the detection of the shadow effect in clutter returns. The echo signal was measured using a X -band radar, that is located on the Pukyong National University, with a horizontal beamwidth of $$3.9^{\circ}$$, a vertical beamwidth of $20^{\circ}$, pulsewidth of $0.8 {\mu}s$ and a transmitted peak power of 4 ㎾ The suppression performance of sea clutter was investigated for the probability of false alarm between $l0-^0.25;and; 10^-1.0$. Also the performance of cell averaging CFAR was compared with that of ideal fixed threshold. The motion vectors and trajectory of ships was extracted and the shadow effect in clutter returns was analyzed. The results obtained are summarized as follows;1. The ARPA plotting results and motion vectors for acquired targets extracted by analyzing the echo signal data were displayed on the PC based radar system and the continuous trajectory of ships was tracked in real time. 2. To suppress the sea clutter under noisy environment, a cell averaging CFAR processor having total CFAR window of 47 samples(20+20 reference cells, 3+3 guard cells and the cell under test) was designed. On a particular data set acquired at Suyong Man, Busan, Korea, when the probability of false alarm applied to the designed cell averaging CFAR processor was 10$^{-0}$.75/ the suppression performance of radar clutter was significantly improved. The results obtained suggest that the designed cell averaging CFAR processor was very effective in uniform clutter environments. 3. It is concluded that the cell averaging CF AR may be able to give a considerable improvement in suppression performance of uniform sea clutter compared to the ideal fixed threshold. 4. The effective height of target, that was estimated by analyzing the shadow effect in clutter returns for a number of range bins behind the target as seen from the radar antenna, was approximately 1.2 m and the information for this height can be used to extract the shape parameter of tracked target..

Effect of Peripheral Opioid Receptor on Masticatory Muscle Pain Control (말초 opioid 수용체에 의한 저작근 통증의 조절 효과)

  • Ko, Seok-Ho;Kang, Soo-Kyung;Auh, Q-Schick;Kim, Eun-Cheol;Hong, Jung-Pyo;Chun, Yang-Hyun
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.161-174
    • /
    • 2013
  • This study was designed to evaluate the pain control effect by morphine injection to masticatory muscle pain patients. Patients with masticatory muscle pain visited the Department of Oral Medicine, Kyung Hee University Dental Hospital were recruited to this study and diagnosed by RDC/TMD. Experimental group were divided into four group; saline injection group (n=10), lidocaine injection group (n=10), morphine 1.5 mg injection group (n=10) and morphine 3 mg injection group (n=10). Evaluation list was the subjective pain evaluation(visual analogue scale, Mc Gill pain questionnaire, pain drawing) and the objective pain evaluation(pressure pain threshold, pressure pain tolerance) and evaluation time was injection before, after 1 hour, 24 hour, 48 hour and then it was analyzed statistically. The results were as follows : 1. The subjective pain evaluation were significantly different statistically in morphine 3 mg group after 48 hour. (VAS: p<0.01, MGQ: p<0.001, PD: p<0.05) 2. The objective pain evaluation were significantly different statistically in morphine 1.5 mg group after 1 hour. (PPT: p<0.01, PPTol: p<0.05) 3. The morphine 3 mg group were more significantly different than lidocaine group and morphine 1.5 mg group statistically in the McGill pain questionnaire evaluation. (1h: p<0.01, 24h: p<0.01, 48h: p<0.001) Therefore, it was revealed that the morphine 3 mg injection was effective to pain control for masticatory muscle pain patients within 48 hours and more effect than lidocaine injection.