• Title/Summary/Keyword: 여자전류

Search Result 142, Processing Time 0.035 seconds

The Design of Gas Turbine Automatic Voltage Regulator for Jeju Thermal Power Plant (제주화력 가스터빈 자동전압조정기 프로토타입 설계 및 시험에 관한 연구)

  • Kim, Bong-Suck;Ryu, Ho-Seon;Lee, Joo-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.494-496
    • /
    • 2007
  • 자동전압조정기는 발전기의 출력 전압을 측정하여 발전기 단자 전압과 계자 전류를 제어하며, 발전기 여자시스템 보호/제한 기능을 수행한다. 본 논문에서는 전력연구원이 개발한 가스터빈 자동전압조정기 프로토타입의 소프트웨어와 하드웨어에 관하여 소개하고, 실험을 통하여 건전성을 확인하였다.

  • PDF

Feasibility Study of Remote Field Eddy Current Testing for Nonmagnetic Steam Generator Tubes (비자성 증기발생기 전열관의 원격장와전류 탐상 가능성 연구)

  • Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.518-525
    • /
    • 2001
  • As steam generator (SG) tubes have aged, new and subtle flaws have appeared. Most of them start growing from outside the tubes. Since signals from outer diameter (OD) defects are very weak compared to those from inner diameter (ID) defects in the conventional eddy current testing due to skin effect, this paper studies the feasibility of using remote field eddy current (RFEC) technique, which has shown equal sensitivity to ID and OD defects in the ferromagnetic pipe inspection. Finite element modeling studies show that the operating frequency needs to be increased up to a few hundred kHz in order for RFEC effects to occur in the nonmagnetic SG tube. The proper distance between exciter and sensor coils is also found to be about 1.5 OD, which is half the distance used in the ferromagnetic pipe inspection. Defect signals obtained by the designed RFEC probe show equal sensitivity to ID and OD defects and the existence of linear relationship between defect depth and phase signal strength. These results tell us that RFEC inspection is feasible even in nonmagnetic steam generator tubes.

  • PDF

Efficiency Optimization Control of SynRM Drive using Multi-AFLC (다중 AFLC를 이용한 SynRM 드라이브의 효율 최적화 제어)

  • Choi, Jung-Sik;Ko, Jae-Sub;Jang, Mi-Geum;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.44-54
    • /
    • 2010
  • Optimal efficiency control of synchronous reluctance motor(SynRM) is very important in the sense of energy saving and conservation of natural environment because the efficiency of the SynRM is generally lower than that of other types of AC motors. This paper is proposed a novel efficiency optimization control of SynRM considering iron loss using multi adaptive fuzzy learning controller(AFLC). The optimal current ratio between torque current and exciting current is analytically derived to drive SynRM at maximum efficiency. This paper is proposed an efficiency optimization control for the SynRM which minimizes the copper and iron losses. There exists a variety of combinations of d and q-axis current which provide a specific motor torque. The objective of the efficiency optimization control is to seek a combination of d and q-axis current components, which provides minimum losses at a certain operating point in steady state. The control performance of the proposed controller is evaluated by analysis for various operating conditions. Analysis results are presented to show the validity of the proposed algorithm.

Analysis of Current Perception Threshold(CPT) Change after Dental Surgery using Neurometer (치과 수술 후 뉴로미터를 이용한 전류인지역치의 변화의 분석)

  • Park, Jin-Hyung;Ryu, Ji-Won;Ahn, Jong-Mo;Ok, Soo-Min;Yoon, Chang-Lyuk
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2010
  • The goal of this study is to contribute to the clinical application by making a quantitative nerve current perception threshold(CPT) examination for the evaluation of numbness that could be occurred after dental surgery, Measurement of CPTs at each different frequencies(2000 Hz, 250 Hz, and 5 Hz) were performed to trigeminal nerve main branch(mandibular division) of 29 patients with dental surgery on mandibular area and 25 normal subjects. There were significant differences in CPTs between patient group and control group.(p<0.05) But, there were no significant between patient male and female in both patient and control group except 2000 Hz was significantly high in the control female.

Comparative Study on Adsorption Properties of Carbons Derived from Lignin and Polymer/Lignin Composite Precursors (리그닌 및 고분자/리그닌 복합소재 탄화 생성물의 흡착 특성 비교)

  • Young Soon Im;Ahyeon Jin;Sun Young Park;Mijung Kim;Joonwon Bae
    • Applied Chemistry for Engineering
    • /
    • v.34 no.5
    • /
    • pp.488-492
    • /
    • 2023
  • In this study, a carbon film derived from a polymer/lignin composite precursor was produced by a carbonization cycle with a controlled temperature profile. The feasibility of successful formation of the carbon film using the carbonization cycle was monitored. The adsorption behavior of the carbon film toward various molecules, such as nonpolar and polar organic molecules, and dyes was investigated using ultraviolet/visible (UV/Vis) spectroscopy compared with that of carbonized lignin. Cyclic voltammetry (CV) analysis proved that a robust carbon film was prepared by the carbonization cycle. It was also demonstrated that the carbonized lignin and carbon film showed adsorption capability toward all types of organic molecules, in particular organic dyes, owing to the carbonized lignin. This work provides important information for future relevant research.

Induction Motor Starting Characterization with Power Factor Correction Capacitors (역률개선 콘덴서를 이용한 유도전동기 기동특성 분석)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.206-212
    • /
    • 2017
  • Induction motor torque is the reactive power is needed which corresponds to the exciting current to generate the magnetic flux as the product of current and flux. For use in the method of supplying the required reactive power to the induction motor power factor correction apparatus using a lot of ways to supply in place of the power supply side, when using a power factor compensation device can reduce the apparent power, the power factor can be improved. However, the distance to the emergency generator transformers or motors from the motor capacity is smaller but short and difficult to maneuver the theory and practice of the operating characteristics of the starting characteristics of the motor used a lot of large industrial plants were measured and analyzed. Therefore, this study investigated the motor starting Analysis and interpretation for the relationship with the large motor starting torque and speed during motor starting.

Vector Control of SPMSM Using MATLAB/SIMULINK & dSPACE 1104 System (MATLAB/SIMULINK와 dSPACE 1104 시스템을 이용한 표면 부착형 영구자석 동기전동기 벡터제어)

  • Lee, Yong-Seok;Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.317-326
    • /
    • 2008
  • This paper presents a vector control implementation for SPMSM(Surface-mounted Permanent Magnet Synchronous Motor) using dSPACE 1104 system and MATLAB/SIMULINK. SPMSM can be treated as a DC motor provided that currents of flux and torque component are controlled independently using vector control. Therefore various control algorithms for conventional DC motor control can be adopted to SPMSM. The system is designed to improve set-point tracking capability, fast response, and accuracy In This paper, d-q equivalent modeling of PMSM is derived based on vector control theory. PI controller is used for speed control and decoupling PI controller is used for current control. For the implementation of high performance vector control system, dSPACE 1104 system is used. Experiments were carried out to examine validity of the proposed vector control implementation.

Sliding-Mode Based Direct Power Control of a Doubly Fed Induction Generator for Wind Turbines (슬라이딩 모드 기반의 이중여자 유도형 풍력발전시스템의 직접전력제어기법)

  • Kim, Won-Sang;Sim, Gyung-Hun;Lee, Kyo-Beum;Jeong, Byoung-Chang;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.152-162
    • /
    • 2008
  • This paper presents a sliding mode controller (SMC) to directly control the active and reactive powers of a doubly ffd induction generator (DFIG) for wind turbines. Sliding-mode control (SMC) and space-vector modulation (SVM) are combined to ensure high-performance operation. SMC scheme is designed to provide robust and fast power controls without frame transformation and current controller used in the conventional FOC drive. Simulation results and experimental results demonstrate that proposed methods preserve the effectiveness and robustness during variations of active and reactive power.

Topology of the Novel High Frequency Insulated Soft Switching PWM DC-DC Converter (새로운 고주파 절전형 소프트 스위칭 PWM DC-DC 컨버터의 토폴로지)

  • Kwon, Soon-Kurl;Suh, Ki-Young;Kim, Ju-Yong;Lee, Su-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.119-124
    • /
    • 2006
  • A novel high frequency insulated soft switching PWM DC-DC converter circuit is proposed and then it is achieved the high-efficiency. This converter does not use the o(citing current of a high frequency transformer but use inductance. Then it realizes a widely stable zero voltage switching operation with the use of a novel ON-OFF control method at synchronized rectification power MOSEFETs of the high frequency insulated transformer secondary. Therefore, it is brought over 97[%] measurement efficiency by proposed DC-DC converter.

Magnetostriction and Magnetic Anisotropy Measurement Using High Efficiency Small EIectromagnet (고능률 소형 전자석에 의한 자왜 및 자기이방성 측정)

  • 이용호;신용돌;김병걸;민복기;송재성
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.179-183
    • /
    • 1994
  • A high efficiency small electromagnet (22 mm air gap and $40{\times}25mm^{2}$ core's cross section) suitable for measuring magnetostriction and magnetic anisotropy was biult. The magnet could be minaturized by reducing the measuring space and time. The excitation current of the electromagnet was supplied for only a few second of measuring time. Cooling system of the electromagnet could be eliminated since the dissipation energy was very small. An 0.5 T magnetic field was generated with 180 W power consumption. The values of magnetostriction and magnetic anisotropy were measured with a very sensitive capacitance cell with resolution of $10^{-8}$ and 1 nJ. The torque was calibrated using a soft magnetic ribbon's shape anisotropy.

  • PDF