When designing the size of a heavy maintenance shop for rolling stock, it is required to arrange buildings and facilities in the minimum site so as to improve the maintenance efficiency. However, the fluctuation rate (hereinafter "allowance rate") on which factors such as service and maintenance fluctuation should be applied when estimating the size of the maintenance shop has been used without verification. The objective of the study is to calculate a reasonable allowance rate and to review its appropriateness through the analysis of the facilities layout and process simulation to absorb the above elements into the staying time in the heavy maintenance shop. Since the working time, in this study, is assumed to be average working time, 10~20% was given to the standard deviation of working time in consideration of difference between workers, and possible allowance rate was drawn by analysis of the simulation results. In the future, it is required to optimize the size of the shop by applying appropriate allowance rate through scientific review of such factors as O&M plan, R/S reserve rate, capability of the shop, outsourcing rate, standard work amount, and so on.
Kim, Jin-San;Choi, Jin-Sung;Kang, Feel-soon;Bin, Jae-Goo
Proceedings of the KIPE Conference
/
2015.07a
/
pp.437-438
/
2015
수중함 전력시스템(UVPS: Underwater Vehicle Power System)은 함 내에 모든 부하들의 전력 공급을 담당하는 시스템으로서 전력 계통의 안정적인 운영을 위하여 수중함 전력시스템의 신뢰성 확보는 매우 중요한 요소이다. 본 논문에서는 기본형태의 수중함 전력시스템과 장비 여유율을 고려한 수중함 전력시스템의 전기 계통 구성을 비교하고 이에 따른 고장나무 분석을 실시하여 장비 여유율을 고려한 수중함 전력시스템의 신뢰성 향상을 확인한다.
Cascaded H-bridge 멀리레벨인버터는 출력전압 레벨 수를 증가시켜 고전압 응용이 가능하도록 하는 전력변환장치로 모듈화 특성이 우수하여 그 활용 범위를 넓혀가고 있다. 출력 전압레벨 수를 증가시켜 보다 정현파에 가까운 양질의 출력전압을 생성하기 위해서는 스위칭 소자와 입력 전압원 개수의 증가로 인해 회로구조와 제어방법이 복잡해지는 문제가 발생한다. 하지만 스위칭 여유율(Redundancy)에 따른 대체 스위칭 패턴의 적용으로 전체 시스템의 신뢰성을 개선시킬 수도 있다. 본 논문에서는 고장나무 분석을 통해 Cascaded H-bridge 멀티레벨 인버터의 위험도를 계산하고 스위칭 여유율과의 관련성을 분석하고자 한다.
전기부문 표준품셈은 전기공사의 예정가격 산정시 가격결정의 기초자료로 활용됨은 물론 적정공사비 반영을 통한 부실시공방지 및 전기공사의 질적 향상과 전기공사업계의 건전한 발전을 유도하고 나아가 국가산업발전에도 큰 영향을 미치는 중요한 기준이나 이러한 중요성에도 불구하고 그 제 개정 절차가 표준화 되어 있지 않는 바, 전기부문 표준품셈 제 개정절차, 표준품셈 실사시 여유율적용 필요성, 여유율 적용요소, 적용사례 등 국내외 관련 자료를 수집 검토하여 합리적인 적용기준(안)을 제시하고자 한다.
KSCE Journal of Civil and Environmental Engineering Research
/
v.30
no.5B
/
pp.509-518
/
2010
This study aims to evaluate for flood stage on vegetated patterns by clearance space rate (CSR) using the numerical models divided into large, medium and small river in river scales with watershed area or design flood discharge. Using the HEC-RAS (1D) and RMA-2 (2D) numerical models, evaluated results of the design flood stages before vegetated modeling of these rivers which CSR in the 1D are obtained over 100% at all points in large river and medium river of except upper part 2 sections, but small river is showed about average 46.0%. It is judge that evaluated results in the 2D are obtained average 101.5% in large river, 96.7% in medium river, 71.1% in small, respectively and because of 1D mainly used to formulate of the river's master plan. However, after vegetated modeling, CSR in case of 1D showed with 91.8% in large river, 74.2% and 38.3% in medium and small rivers, respectively and 2D showed with 95.5% in large river, 86.72 and 37.0% in medium and small rivers, respectively. It is estimate that evaluated results using the 2 numerical models by the vegetated modeling are less affected the CSR for large river in a large area more than the cross section area in medium and small rivers.
Proceedings of the Korean Operations and Management Science Society Conference
/
1993.04a
/
pp.215-224
/
1993
본 논문에서는 고가의 수리가능제품의 최적여유재고 수준을 결정하는 효율적인 방법을 제안한다. 고려하는 시스템은 각 기지창과 중앙창에서 한정된 수리능력을 가지며 중앙창에서 수리가 끝난 후 수리된 제품은 원래의 기지창으로 되돌아가서 재고에 포함되는 형태이다. 제안한 방법은 최소비용의 재고수준을 결정하는 방법 및 최소요구충족율을 가장 적은 비용으로 만족시키는 여유재고수준을 결정하는 최적해법이다. 제안한 방법을 실제시스템에 적용하면 최소의 비용으로 장비나 무기를 원하는 수준으로 가동시킬 수 있으므로 국방비의 효율적인 사용 및 절감에 도움이 될 것이다.
It has been built or remodeled in every year train maintenance centers including subways. However, there is no standard to measure exact capacity. In today, most of criteria is referenced on Japanese. In general, we can standardize the process for 'Train Overhaul Maintenance' because its processes are similar or same patterns. The processes can be the base standard of train maintenance after being classified in detail and validating it. This study is adapt BPR methodology to present standardizes processes and the processes are mapping to layout drawing to constraint from the real world, and then evaluate the capacity using simulation. To guarantee objectivity of input data, we use research data by the National Railroad Administration and Association of Japanese Railway Engineering. Using these data to simulation, we compare to the 'Allowances' and evaluate its adequacy.
Kim, Jin-San;Choi, Jin-Sung;Kang, Feel-soon;Bin, Jae-Goo
Proceedings of the KIEE Conference
/
2015.07a
/
pp.298-299
/
2015
수중함에서 전력시스템(PS:Power System)이란 함의 추진시스템 뿐만 아니라 함 내에 모든 부하들의 전력공급을 담당하는 매우 중요한 요소이다. 수중함에 있어 전력시스템의 고장은 안정성에 직결되는 요소이므로 이에 대한 분석과 신뢰성 확보는 필수적이다. 본 논문에서는 수중함의 전력생산부에서부터 부하까지 전력이 공급되는 과정을 전기계통도로 표현하여 이에 대해 고장나무분석을 실시하였으며, 기본구조와 계통 여유율을 고려한 전기적 구조의 고장나무분석을 실시하여 이에 따른 구조변화를 비교한다.
In HVDC systems, the full-bridge submodule increases the number of components compared to the half-bridge submodule, but the failure-rate can be reduced by securing 100 % redundancy. However, full-bridge submodules require more complex control algorithms to ensure the redundancy and to prevent arm-short with sufficient dead-time. To solve this problem, we analyse the failure-rate of the paralleled half-bridge configuration with the same number of components and 100 % redundancy as the full-bridge submodule. The fault tree analysis (FTA) method is applied to the conventional part failure analysis to reflect the operation risk of the submodule, thereby predicting the life-cycle of the submodule more accurately. To verify the validity, the failure-rate results of the proposed FTA based analysis method are compared with the failure rate obtained by the part failure method.
Proceedings of the Korea Water Resources Association Conference
/
2009.05a
/
pp.1541-1545
/
2009
홍수 기간 중 부유잡목에 의한 수위상승 원인은 크게 상류부에서 이송되어진 유송잡물에 의한 교량 등의 수공구조물에 집적으로 인한 통수능 부족에 의하여 발생되는 수위상승과 하천내 수공 구조물의 부적절한 설계 및 시공으로 인한 수위상승으로 구분되어 진다. 현재 교량의 여유고 산정에 사용되는 홍수위는 통수능을 고려하지 않은, 하천정비계획에 사용되는 홍수위를 적용하고 있으며, 다만 통수능의 확보를 위하여 경간장에 대한 제한을 두고 있을 뿐이다. 중소하천에 위치하는 교량의 경우, 여유고 확보에 대한 기준을 적용함에 있어서 교량이 위치한 하천 단면에서의 통수능의 영향이 고려되어야 유수의 월류에 대한 위험성을 줄일 수 있다. 더욱이 하천설계기준(2005)에서는 고정 홍수량에 의한 여유고 산정치를 제안하고 있을 뿐이기 때문에, 하천설계기준에서 교량과 관련된 여유고도 하상변동과 만곡부에 의한 수위 상승, 유송잡물에 의한 통수능 영향, 계산오차 등을 고려하여 충분한 여유고를 확보하도록 보완할 필요가 있다. 본 연구에서는 부유잡목에 의한 수위상승 원인을 분석을 하고, 이에 따른 수리모형실험을 통하여 부유잡목의 높이/폭(H/B)변화에 의한 수위상승, 부유잡목의 형태별 수위상승, 교각사이 개도비에 따른 수위 상승량을 산정하여 기존의 여유고에 대한 추가적인 여유고를 확보하여 홍수시 통수능을 확보하고자 하였다. 부유잡목의 형태에 따른 수위상승량을 산정하기 위하여 개도비를 70%로 고정한 후, Fr수를 변화시켜 부유잡목의 높이/폭(H/B) 형태에 따라 산정한 결과, 부유잡목이 존재하지 않는 상태에 비하여 부유잡목에 의한 영향으로 인한 수위증가율이 Fr값이 클수록 더욱 크게 나타났으며, 부유잡목이 동일면적인 경우 폭(B)에 비하여 높이(H)가 커질수록 수위 상승이 크게 나타났다. 또한, Fr수 변화에 따른 최고수위 상승율을 구하였을 때, 상류조건에서 Fr < 0.5 인 경우는 기존 여유고에 대하여 최대 10%의 여유고를 추가 확보하며, 0.5 < Fr < 1 인 경우는 기존 여유고에 대하여 최대 20%의 여유고를 추가 확보하도록 설계하는 것이 바람직하다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]