• 제목/요약/키워드: 여과재

Search Result 288, Processing Time 0.028 seconds

Initial Operating Condition of Membrane Bioreactor with PVDF Hollow Fiber and Permeate Reuse (PVDF 중공사막을 이용한 막생물반응기의 초기 운전조건 설정 및 여과수 재활용)

  • Shin, Choon-Hwan;Kang, Dong-Hyo;Park, Hae-Sik;Cho, Hyun-Kil
    • Clean Technology
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • In this paper, 4 bundle modules of PVDF hollow fiber membrane from Woori Tech company (Korea) were manufactured in a treatment capacity of 10 ton/day. A membrane bioreactor (MBR) pilot plant was installed at Sooyoung Wastewater Treatment Plant in Busan. An alternating aeration process was selected to avoid the concentration profile of suspended solid (SS) in the MBR. For stable operation, raw wastewater with mixed liquor suspended solid (MLSS) of about 1,000 ppm, which was in-flowed from the aeration tank of the wastewater treatment plant, was fed and filtered through the pilot plant. Subsequently the pilot plant were washed three times with washing water: once with ethanol solution, once with a solution of 5% NaOCl, and finally with washing water. After the chemical washing, the remaining water in the MBR was fed into the pilot plant. As a result, the SS removal efficiency was found to be more than 99.9%. The amount of filtrate with the aeration tank influent decreased by 16%, compared with that from the initial conditions, giving rise to 30% increase in the suction pressure. These results were used to set up continuous operation conditions. The results from the continuous operation with influent MLSS of 1,900 mg/L showed that the SS removal efficiency was about 99.99% and that the amount of filtrate and the suction pressure were $42{\sim}52L/m^2$ and 16~20 cmHg, respectively, indicating stable operation of the pilot plant. However, for the reuse of wastewater, methods need to be sought to avoid growth of algae which affects the SS removal efficiency at inlet and outlet of the permeate tank.

Analysis of Reduction Efficiency of Storm water and Pollutant in Filter Type and Clearance Type Permeable Blocks (침투형 및 틈새형 투수블럭에서의 빗물유출 및 오염물질 저감효율 분석)

  • Gil, Kyungik;Lee, Dawon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.210-210
    • /
    • 2020
  • LID (Low Impact Development, 저영향개발)는 산업화 및 도시화 진행 지역에서 비점오염원으로부터 배출되는 오염물질을 제어해 개발지역 내 자연순화 기능을 최대한 유지하고, 물순환 기능증대를 통해 강우 유출수를 지역 내에서 관리하는 것을 목표로 한다. 비점오염원 저감 LID 시설에는 자연형과 장치형 시설이 있다. 자연형 시설에는 저류형, 침투, 식생형 시설 등이 있다. 특히, 침투시설에는 대표적으로 투수블럭이 있으며, 이는 투수성 포장재를 통해 강우 유출수를 지하로 침투시켜 여과나 흡착 등으로 비점오염물질을 제어하는 시설이다. 장치형 시설로는 여과재나 망을 이용해 비점오염물질을 분리하는 여과형 및 스크린형 시설, 응집과 침전을 통해 비점오염물질을 분리하는 응집·침전 시설 등이 있다. 이에 본 연구는 2016년부터 2018년 3년간 전주 서곡지구 지역 내 설치된 필터형 투수블럭, 틈새형 투수블럭에서 진행했다. 각각의 투수블럭에서 총 19회, 20회의 강우 모니터링을 실시했고, 오염물질 유입 및 유출 EMC 등의 분석을 통해 유출 및 오염물질 저감효과를 분석했다. 연구 대상 각 투수블럭의 주요 제원은 시설 용량 14.4㎥, 시설 면적은 14.4㎡이다. 모니터링 결과값을 분석한 결과 필터형 투수블럭의 경우 유출 저감율은 17.4 ~ 100%, 틈새형 투수블럭은 29.6 ~ 100%이었다. 필터형 투수블럭과 틈새형 투수블럭의 단위면적당 유량 저감량은 각각 0.014 ~ 0.583㎥/㎡, 0.035 ~ 0.588㎥/㎡이었다. 오염물질 저감효율을 분석한 결과 유기물 항목(BOD, TOC)의 경우 틈새형 투수블럭에서의 저감효율(BOD 93.59%, TOC 90.39%)이 필터형 투수블럭에서의 저감효율(BOD 89.99%, TOC 86.94%) 보다 다소 높게 나타났다. 영양염류 항목(T-N, T-P)의 경우 필터형, 틈새형 모두 비슷한 저감효율(필터형 T-N 89.02%, 필터형 T-P 98.12%, 틈새형 T-N 90.41%, 틈새형 T-P 98.04%)을 보였다.

  • PDF

The Ultrafiltration Characteristics of Oil/Water Emulsion Using Modified Polysulfone Membrane (표면처리 한 polysulfone 막으로 오일/물 에멀젼의 한외여과 특성)

  • Jeong, Gyeong-Hwan;Lee, Kune-Woo;Kim, Kil-Jeong;Jung, Ki-Jung;Kim, Chul
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.119-126
    • /
    • 1999
  • 본 연구는 polysulfone 막을 표면처리 하여 오일 폐수를 한외여과 처리하였고 이때 fouling의 감소효과를 실험하였다. 고분자나 계면활성제를 polysulfone막에 흡착시켜 표면처리를 하였다. 다양하게 표면처리된 막으로 dodecane(0.1 v%)/물 에멀젼과 dodecane-계면활성제/물 에멀젼을 회분식 실험방법으로 수행하였다. SDS로 개질한 막으로 dodecane-계면활성제/물 에멀젼을 환외여과 처리하였을 때 fouling이 가장 작게 나타났고, 재사용에 좋은 방법으로 나타났다.

  • PDF

Development of Wastewater Reclamation System With Use of Microfilter and Reverse Osmosis (정밀여과와 역삼투를 이용한 방류수 재이용 시스템 개발)

  • 강신경
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.119-122
    • /
    • 2004
  • 최근 들어 용수가격 상승과 갈수기 대비 대체용수 확보차원에서 폐수를 처리하여 공업용수를 재이용하는 사례가 증가하고 있다. 국내의 경우 단위 사업장에서 폐수재이용 시설을 설치한 사례는 비교적 많은 편이나, 정상적으로 가동하는 경우는 드문 것으로 조사되고 있다[1]. 이는 초기 시설 투자비를 줄이기 위하여 전처리를 소홀히 한 것이 가장 큰 원인으로 판단된다.(중략)

  • PDF

A Study of the Reduction of Diesel-Engine Emissions for Off-Road Vehicles (비도로 차량용 디젤엔진의 배기가스 저감에 관한 연구)

  • Cho, Gyu-Baek;Kim, Hong-Suk;Kang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.577-583
    • /
    • 2011
  • To meet the requirements of the Tier 4 interim regulations for off-road vehicles, emissions of particulate matter (PM) and nitrogen oxides (NOx) must be reduced by 95% and 30%, respectively, compared to current regulations. In this research, both the DPF and HPL EGR systems were investigated, with the aim of decreasing the PM and NOx emissions of a 56-kW off-road vehicle. The results of the experiments show that the DOC-DPF system is very useful for reducing PM emissions. It is also found that the back pressure is acceptable, and the rate of power loss is less than 5%. By applying the HPL EGR system to the diesel engine, the NOx emissions under low- and middle-load conditions are reduced effectively because of the high differential pressure between the turbocharger inlet and the intake manifold. The NOx emissions can be decreased by increasing the EGR rate, but total hydrocarbon (THC) emission increases because of the increased fuel consumption needed to compensate for the power loss caused by EGR and DPF.

Comparison of Algal Growth Kinetics using Reclaimed Wastewaters from Various Treatment Processes (다양한 수질정화 공정 별 하수처리수 재이용수의 조류성장 비교)

  • Joo, Jin-Chul;Seo, Sou-Hyun;Song, Ho-Myeon;Kim, Il-Ho;Ahn, Chang-Hyuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.309-309
    • /
    • 2011
  • 지구온난화와 도시기후 변화에 대응하기 위해 자연의 생태적 기능을 복원하고 환경에 대한 오염부하를 저감하여 도시 환경의 건강성과 지속성을 높이기 위해 도심 내 물순환시스템(urban water circulating system)의 구축이 요구된다. 즉, 물순환시스템을 활용하여 도심 내 다양한 수원(생태하천/호수 유지용수, 하수처리수, 우수, 지하수 등)을 네트워크 및 통합 관리하여 도시 내 물순환의 건전성과 수자원의 재이용률을 향상시킬 수 있다. 이를 위해서 연중 발생량이 일정하고 막대한(66.4억톤/년, 2009년 기준) 하수처리수 방류수는 고도처리를 통해 수질이 양호하며 안정적인 대체 수자원으로 고려된다. 또한, 하수처리수의 재이용은 공공수역으로 배출되는 오염부하량의 총량 삭감 및 상수사용량의 절감과 수자원을 효율적으로 이용한다는 면에서 최근 재이용 사례가 증가하고 있는 추세이다. 그러나, 도심 내 친수공간(생태하천/호수)은 저류수량에 비해 유입수량이 적어 체류시간이 비교적 장시간이고, 이로 인해 부영양화가 쉽게 발생해 수질이 악화된다. 따라서, 본 연구에서는 하수처리수 재이용수를 도심 내 친수공간의 유지용수로 활용 시, 수질정화공정(응집 후 여과, 응집 후 여과+한외여과, 응집 후 여과+한외여과+역삼투 공정)이 친수공간 내 조류성장에 미치는 영향을 파악하기 위해, 하수처리수 재이용수 pilot plant의 수질정화공정별 유출수를 활용해 M. aeruginosa를 시험조류로 조류성장(growth kinetics)을 조사하였다. 조류는 $5\times104$ cells/mL의 초기 농도로 접종하여 배양하였으며, 조류성장에 직접적인 제한인자인 용존반응성인의 농도에 따른 성장속도를 Monod와 변형 Monod Kinetics를 이용해 반포화상수(Ks)와 최대 성장속도(${\mu}$max)를 산정하였다. 실험결과, 역삼투 공정을 제외한 다른 수질정화공정은 비록 영양염류가 80~90% 이상 제거되어 수계의 화학적 성상이 변하였으나 조류성장역학의 변화는 통계학적 (p=0.05)으로 유의할만한 수준은 아닌 것으로 판명되었다. 또한, 수리학적 체류시간이 2주 이상이 될 경우, 역삼투 공정을 제외한 수질정화공정 별 유출수에서는 조류의 과다성장으로 인해 부영양화가 발생하는 것으로 판명되었다. 결론적으로 하수처리수 재이용수를 친수용수로 활용시, 조류성장을 방지하기 위하여 용존반응성인의 농도를 중점적으로 관리하는 수질정화공정 및 유지용수 공급방안을 고려해야하는 것으로 판단된다.

  • PDF

Evaluation of Downflow Granular Media Filtration for Stormwater Treatment (강우유출수에 의한 비점오염 저감을 위한 하향류식 입상여과 효율 평가)

  • Lim, Chan-Su;Kim, Do-Gun;Ko, Seok-Oh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.684-693
    • /
    • 2012
  • The stormwater runoff from the increasing paved roads and vehicles resulted in the increase in the pollutants load to adjacent water bodies. The granular media filtration facilities are the most widely adopted to minimize the non-point source pollution from motorways. It is essential to consider the severe variation of hydraulic condition, suspended solid (SS) characteristics, and the medium characteristics for stormwater management filter. In this study, different types of media, including sand, were tested and the performance of downflow sand filters was investigated under various linear velocity and influent solid particle size. Results showed that the best medium is the coarse sand with large grain size, which showed the specific SS removal before clogging of more than $8.498kg/m^2$, the SS removal of higher than 95%, and minimum head loss. Linear velocity did not affect the total solid removal, while the performance was improved when fine solid was introduced. It is suggested that the life of a downflow sand filter bed can be extended by deep bed filtration when influent particles are fine. However, the captured particles can be washed out after a long period of operation.

A Study on the Filtration of BNR Process Effluent (BNR공정 처리수의 여과에 관한 연구)

  • Kim, Seong-Young;Bum, Bong-Su;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.895-905
    • /
    • 2000
  • This study was performed to investigate the removal efficiencies of pollutants at various filtration rates and the quality of the filtered water along the depth of filter media during treatment of a BNR process effluent by a dual-media gravitational rapid filtration. The results of the experiments at filtration rates of 200, 300 and 400 m/day using the effluent of a pilot scale 4-stage BNR plant showed that turbidity of the filtered water was below 2.6 NTU, satisfying the Korean standard for water for reuse. Even though the SS removal efficiency deteriorated as the filtration rate increased, the average SS concentration of the filtered water was 1.3 mg/L at all filtration rates. Simultaneous biological nitrification and denitrification was observed with nitrification efficiencies of 17.4, 18.8 and 14.3%, and denitrification efficiencies of 32.3, 27.7 and 21.4% respectively at filtration rates of 200, 300 and 400 m/day. At the latter period of each filtration cycle, the effluent T-P concentration was higher than influent T-P concentration by 6.1 to 21.4% due to phosphorous release under DO-deficient condition.

  • PDF