• 제목/요약/키워드: 에어컨 소음

검색결과 89건 처리시간 0.025초

천장형 에어컨 소음의 허용 음압레벨 도출 (Allowable sound pressure levels of ceiling mounted air-conditioning sounds)

  • 유진;정충일;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

공조용 로터리 압축기 소음저감을 위한 어큐뮬레이터 최적설계 (Design Optimization of an Accumulator for Noise Reduction of Rotary Compressor)

  • 이의윤;김봉준;이정배;성춘모;이운섭;이종수
    • 대한기계학회논문집A
    • /
    • 제35권7호
    • /
    • pp.759-766
    • /
    • 2011
  • 최근 가정용 에어컨은 냉방효율뿐 아니라 소음에 대한 중요성이 지속적으로 높아지고 있다. 로터리 압축기는 에어컨의 소음 중 매우 높은 영향도를 가지고 있으며, 압축기의 소음을 줄이기 위해 머플러 및 공명기에 관한 많은 연구들이 진행되어 왔다. 압축기의 부품 중 어큐뮬레이터는 큰 용적으로 인해 공명에 의한 추가 소음을 에어컨에 전달하는 소음 전달경로가 되며, 어큐뮬레이터의 내부구조는 소음저감을 위해 중요한 설계요소가 되나 지금까지는 연구결과가 미비한 수준이었다. 본 논문에서는 어큐뮬레이터의 소음 저감을 위해 목표주파수 대역에서의 투과손실이 최대가 되는 설계최적화를 수행하였다. 높은 비선형성을 가진 문제의 최적화를 위해 실험계획법과 반경기저신경망기법을 이용한 근사 모델을 사용하였으며, 유전알고리즘을 사용한 최적화를 수행하였다.

에어컨 실내기의 방사소음과 실외기의 투과소음에 의한 환경소음 예측 (Environmental Noise Assessment of Indoor and Outdoor Units of Air-conditioner)

  • 장서일;최진권;손진희;모진용;구형모
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.40-47
    • /
    • 2003
  • This study was conducted to determine the sound paths and transmitted sound level in house. An air-conditioner system was selected a typical sound source. The measured transmission loss data shows that the apertures have an significant effect on the transmitted noise and comparable with the existing theoretical data. Therefore the complex aperture was substitute to quantitative apertures approximately. An effective simulation method, ray tracing and mirror image source method, was employed in the prediction of transmitted sound level. The measured results were efficiently reflected on the simulated results. So it is important that measuring the acoustic parameter prior to the prediction of the transmitted sound level in the house.

차량용 에어컨 부밍 소음의 전달 특성에 관한 연구 (A Study on Transfer Characteristics of Vehicle Air-conditioner Booming noise)

  • 임승택;주경훈;안휴남;박영덕;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.476-481
    • /
    • 2013
  • Transfer path analysis(TPA) and operational deflection shape(ODS) have been widely utilized to analyze the characteristics of noise. TPA enables to decompose a noise into air-borne and structure-borne noises then estimate the path contribution of noise. ODS enables to analyze a moving shape and direction of interest components at a particular frequency. In this paper, TPA and ODS are applied to transfer paths of air-conditioner booming noise in a vehicle to reduce noise level, then a fixture is mounted it's path for distributing the high portion path contribution to the low portion path contribution. Through this experiment, the reduction of sound pressure level in air-conditioner booming noise is observed. Thereafter, TPA is again employed to verify the results of contribution.

  • PDF

에어컨 실내기에서 발생하는 충격 소음원의 위치 추정 (Source localization of impact noise on an indoor unit of air-conditioner)

  • 최영철;김양한;이종구;김구영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

R-410A 냉매를 적용한 9,000Btu 군용에어컨의 진동시험규격과 동특성시험 비교 분석 (A Comparison Analysis on The Vibration Test Standard and The Dynamic Characteristic Test of 9,000 Btu Military Airconditioner Applying Refrigerant R-410A)

  • 최동설;이원영;신영훈;임영택
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.519-520
    • /
    • 2010
  • R-410A 냉매를 적용한 9,000 Btu 군용에어컨은 2 1/2톤 쉘터카고 차량에 탑재된 쉘터를 냉, 난방하기 위해 사용된다. 이 에어컨은 차량에 탑재된 쉘터의 벽면에 설치되기 때문에 차량 이동 중의 진동, 충격 환경에서 그 기능이 유지되어야 하며, 이에 대한 진동시험을 실시한다. 진동시험은 MIL-STD-810G, 514.5C-VII Composite Wheeled Vehicle 규격에 따라 수행하며, 동특성시험을 통해 확보된 입력 진동값을 진동 규격과 비교하여 적합성을 판단한다.

  • PDF

실험적 방법을 통한 에어컨 실내기의 소음원 검출에 관한 연구 (A Study on Noise Identification of Indoor Air-conditioner Using Experimental Methods)

  • 이성진;오재응;이정윤;강태호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.87-87
    • /
    • 2004
  • An air-conditioner has various noise sources such as a fan noise, a motor noise, and a vibration induced noise. To reduce these noise effectively, noise sources must be identified. Especially in this paper, the structure borne sound radiated from the motor bracket of the indoor air-conditioner is considered. To do this, the operational deflection shape, which is used for understanding of the behavior of the motor bracket at a particular frequency, is obtained and compared with the sound intensity, which is used for the noise identification. Through this study, the noise sources of indoor air-conditioner are defined and the effective noise reduction method is proposed.

  • PDF

에어컨 소음의 Sound Quality 평가 (Evaluation of Sound Quality of Air-conditioning Noise)

  • 전진용;유진;김수연
    • 한국소음진동공학회논문집
    • /
    • 제16권5호
    • /
    • pp.551-558
    • /
    • 2006
  • Noise from air-conditioner system installed in the ceiling of a classroom was evaluated to investigate the sound quality of air-conditioning noise. Harmonics of air-conditioning noise were removed and the sound pressure levels of the frequency bands from $250{\sim}630Hz$ were changed to control sound quality. Evaluation for refreshing sensation was conducted using a paired comparison method and the results showed that noise without harmonics were preferred to noise with harmonics. The noises which have larger level increases to the unchanged noise at $250{\sim}630Hz$ were evaluated better in both of the noises with and without harmonics. Results of multiple regression analysis on psychoacoustic parameters and subjective preferences showed sharpness as a major affecting factor in describing the refreshing aspect of air-conditioning sound.