• Title/Summary/Keyword: 에리스로신

Search Result 8, Processing Time 0.028 seconds

Study on Adsorption Characteristics of Erythrosine Dye from Aqeous Solution Using Activated Carbon (활성탄에 의한 에리스로신 염료수용액의 흡착특성에 관한 연구)

  • Lee, Jong-Jib
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.224-229
    • /
    • 2011
  • Adsorption characteristics of erythrosine dye onto the activated carbon has been investigated in a batch system with respect to initial concentration, contact time and temperature. Kinetic studies of the adsorption of erythrosine were carried out at 298 K, using aqueous solutions with 100, 250 and 500 mg/L concentration of erythrosine. The adsorption process followed a pseuo second order model, and the adsorption rate constant (k2) decreased with increasing the initial concentration of erythrosine. The equilibrium process can be well discribed by Freundlich isotherm in the temperature range from 298 to 318 K. Free energy of adsorption (${\Delta}G^o$), enthalpy (${\Delta}H^o$), and entropy (${\Delta}S^o$) change were calculated to predict the nature the adsorption. The estimated values for ${\Delta}G^o$ were -3.72~-9.62 kJ/mol over the activated carbon at 250 mg/L, indicated toward a spontaneous process. The positve value for ${\Delta}H^o$ indicates that the adsorption of erythrosine dye on activated carbon is an endothermic process.

Effect of Potassium Iodide on Erythrosine-Mediated Photodynamic Therapy on Streptococcus Mutans Biofilms (Streptococcus mutans 바이오필름에 대한 에리스로신 매개 광역동 치료 시 potassium iodide의 효과)

  • Yongsoon, Kim;Howon, Park;Juhyun, Lee;Haeni, Kim;Siyoung, Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.321-328
    • /
    • 2022
  • The aim of this in-vitro study is to evaluate the effect of potassium iodide (KI) on erythrosine-mediated photodynamic therapy (PDT) against Streptococcus mutans biofilms. S. mutans ATCC 25175 was cultured to form a biofilm on a hydroxyapatite disk. After diluting erythrosine to 20 μM and KI to 10, 50, and 100 mM, respectively, PDT was performed. The number of surviving bacteria was calculated as colony forming units (CFU)/mL and the statistical significance of the difference between groups was confirmed by Bonferroni post-hoc analysis. Cell viability was visually evaluated using confocal laser scanning microscopy (CLSM). As a result of the experiment, a significant decrease (p < 0.05) in CFU was observed in the experimental groups in which PDT was performed after applying KI regardless of the concentration of KI. In addition, a significant reduction (p < 0.05) in CFU was observed in the experimental group to which 100 mM KI was applied compared to 10 mM KI. The same results were confirmed when observing CLSM. KI significantly improved the efficacy of erythrosine-mediated PDT on S. mutans biofilms at all concentrations. This may compensate for the low sensitivity of PDT to biofilm-state bacteria strains, but it is necessary to establish an optimal clinical protocol through further research.

Antimicrobial effect of toothbrush with light emitting diode on dental biofilm attached to zirconia surface: an in vitro study (지르코니아 표면에 부착된 바이오필름에 대한 LED 치솔의 항균효과)

  • Park, Jong Hew;Kim, Yong-Gun;Um, Heung-Sik;Lee, Si Young;Lee, Jae-Kwan;Chang, Beom-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.160-169
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the antimicrobial effects of a toothbrush with light-emitting diodes (LEDs) on periodontitis-associated dental biofilm attached to a zirconia surface by static and dynamic methods. Materials and Methods: Zirconia disks (12 mm diameter, 2.5 mm thickness) were inserted into a 24-well plate (static method) or inside a Center for Disease Control and Prevention (CDC) biofilm reactor (dynamic method) to form dental biofilms using Streptococcus gordonii and Fusobacterium nucleatum. The disks with biofilm were subdivided into five treatment groups-control, commercial photodynamic therapy (PDT), toothbrush alone (B), brush with LED (BL), and brush with LED+erythrosine (BLE). After treatment, the disks were agitated to detach the bacteria, and the resulting solutions were spread directly on selective agar. The number of viable bacteria and percentage of bacterial reduction were determined from colony counts. Scanning electron microscopy (SEM) was performed to visualize alterations in bacterial morphology. Results: No significant difference in biofilm formation was observed between dynamic and static methods. A significant difference was observed in the number of viable bacteria between the control and all experimental groups (P < 0.05). The percentage of bacterial reduction in the BLE group was significantly higher than in the other treated groups (P < 0.05). SEM revealed damaged bacterial cell walls in the PDT, BL, and BLE groups, but intact cell walls in the control and B groups. Conclusion: The findings suggest that an LED toothbrush with erythrosine is more effective than other treatments in reducing the viability of periodontitis-associated bacteria attached to zirconia in vitro.

Susceptibility of Mutans streptococci in the Planktonic and Biofilm State to Erythrosine (부유 상태와 바이오필름 상태에서 Mutans streptococci의 Erythrosine에 대한 감수성 평가)

  • Gong, Jungeun;Seo, Hyunwoo;Lee, Siyoung;Park, Howon;Lee, Juhyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.135-138
    • /
    • 2019
  • The aim of this study was to investigate the susceptibility of Mutans streptococci in both planktonic and biofilm states to erythrosine. S. mutans was cultured in brain-heart infusion (BHI) broth. Erythrosine was diluted in BHI broth and prepared at a concentration range of $0.02-10000{\mu}g/L$. The minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) were measured using the microdilution method. After forming biofilms on 96-well plates, the minimum biofilm inhibitory concentration (MBIC) and minimum biofilm eradication concentration (MBEC) were measured. S. mutans was susceptible to erythrosine in both planktonic and biofilm states. MIC and MBC values were both $19.5{\mu}g/L$ for the planktonic state, while MBIC and MBEC values were $313{\mu}g/L$ and $2500{\mu}g/L$, respectively, for the biofilm state. Erythrosine ($19.5{\mu}g/L$) exhibited a bactericidal effect on S. mutans (killing 99.9%) in the planktonic state. For biofilms, erythrosine inhibited biofilm growth and eradicated 99.9% of biofilm bacteria at higher concentrations than MIC and MBC. These MBIC and MBEC concentrations are much lower than known noxious doses, and the MIC, MBC, and MBIC values were even lower than clinical concentrations.

THE EFFECT OF PHOTODYNAMIC THERAPY ON THE VIABILITY OF STREPTOCOCCUS MUTANS ISOLATED FROM ORAL CAVITY (광역동 치료가 구강 내에서 분리한 수종의 Streptococcus mutans의 생존력에 미치는 영향)

  • Jung, Ji-Sook;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo;Lee, Si-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.233-241
    • /
    • 2012
  • Photodynamic therapy (PDT) is a technique that involves the activation of photosensitizer by light in the presence of tissue oxygen, resulting in the production of reactive radicals capable of inducing cell death. The aim of this study was to evaluate the effect of PDT on Streptococcus mutans in planktonic conditions, previously treated with different photosensitive concentrations of erythrosine, using halogen and LED curing unit as a light source. And we compared the effects of PDT on six strains of S. mutans isolated from oral cavity and reference strain. As a result, S. mutans was susceptible to the combination of hand held photopolymerizer (HHP) and erythrosine. The higher concentration of erythrosine in the presence of light irradiation induced greater effects in reduction of viability of S. mutans. Isolated S. mutans showed a significant reduction in bacterial counts of the groups submitted to PDT compared to the control groups. And they appeared to be similar or slightly lower antimicrobial effect compared with reference strain. However, the difference was not significant (p < 0.05). In conclusion, PDT using erythrosine as a photosensitizing agent and HHP as a light source could be an efficient option for diseases caused by S. mutans.

Aqueous-Based Photocurrent Generation by Fluorescence Resonance Energy Transfer between Conjugated Oligoelectrolytes and Erythrosin B (전도성 올리고전해질과 에리스로신 B간 형광공명 에너지전달에 의한 수용액 기반 광전류 생성)

  • Kang, Insung;Park, Jonghyup;Jo, Hyunjin;Park, Juhyun
    • Polymer(Korea)
    • /
    • v.39 no.2
    • /
    • pp.353-358
    • /
    • 2015
  • Aqueous-based, environmentally friendly photocurrent generation has been highlighted to produce electricity by mimicking photosynthesis in nature. We fabricated a photocurrent generation system using a conjugated oligoelectrolyte (COE) assembled in lipid vesicles and a fluorescence dye, and investigated the fluorescence resonance energy transfer (FRET) between two species and the influence of FRET on the photocurrent generation. The FRET efficiency from the electron donor, COE, to the electron acceptor, the dye, increased with the dye concentrations, but the photocurrent increased and then decreased with the dye concentrations. We discussed about the role of FRET and electron shuttles over the variation of photocurrent.

Removal Charateristics of Erythrosine by Activated Carbon Adsorption (활성탄 흡착에 의한 Erythrosine의 제거 특성)

  • Lee, Jong-Jib;Yoon, Sung-Wook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.499-504
    • /
    • 2009
  • Erythrosine is used a food coloring, ink and dye, etc. but erithrosine is rarely used in United States due to its known hazards. The adsorption characteristics of erythrosine by granular activated carbon were investigated in the batch adsorber and the packed column. The adsorptivity of activated carbon for erythrosine were largely improved by pH control. When the pH was 11 in the sample, the erythrosine could be removed 98% of initial concentration. It was estabilished that the adsorption equilibrium of erythrosine on granular activated carbon was successfully fitted by Freundlich isotherm equation in the concentration range from 10mg/L to 1,000mg/L. The characteristics of breakthrough curve of activated carbon packed column depend on the design variables such as initial concentration, bed height, and flow rate.

Color stability of three dimensional-printed denture teeth exposed to various colorants (다양한 색소에 대한 3D 프린팅 인공치의 색 안정성)

  • Koh, Eun-Sol;Cha, Hyun-Suk;Kim, Tae-Hyung;Ahn, Jin-Soo;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • Purpose: This study evaluated color stability of Dentca 3D-printed denture teeth, in comparison to color stabilities of four conventional types of denture teeth, upon being immersed in various colorants. Materials and methods: Four types of conventional prefabricated denture teeth (Surpass, GC, Artic 6, Heraeus Kulzer, Premium 6, Heraeus Kulzer, Preference, Candulor), 3D-printed denture teeth (Dentca); and Z250 (Filtek Z250, 3M ESPE) were prepared for testing. The samples were immersed in erythrosine 3%, coffee, cola, and distilled water (DW) at 37℃. Color change (ΔE) was measured by spectrophotometer before immersion and at 7, 14, and 21 days after immersion. One-way analysis of variance was performed along with Tukey's honestly significant difference multiple comparisons test (P<.05). Results: No great difference was observed between the color change of Dentca denture teeth and that of conventional denture teeth in most cases (P>.05). The color change of Dentca denture teeth immersed in erythrosine 3% was greater than that of Surpass (ΔE = 0.67 ± 0.25) after 1 week; Artic 6 (ΔE = 1.44 ± 0.38) and Premium 6 (ΔE = 1.69 ± 0.35) after 2 weeks; and Surpass (ΔE = 1.79 ± 0.49), Artic 6 (ΔE = 2.07 ± 0.21), Premium 6 (ΔE = 2.03 ± 0.75), and Preference (ΔE = 2.01 ± 0.75) after 3 weeks (P<.05). Conclusion: A color change was observed in Dentca denture teeth when immersed in some colorants; however, the maximum value of ΔE for Dentca denture teeth was within the clinically acceptable range.