• Title/Summary/Keyword: 에너지 측정 장치

Search Result 619, Processing Time 0.025 seconds

Parameter Measurement Method for Super Capacitor Failure Diagnosis and Application of Voltage Sag Compensation System Using Super Capacitor (수퍼 커패시터의 고장진단을 위한 파라미터의 측정기법과 순시전압강하 보상장치에의 응용사례)

  • Shon, Jin-Geun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.6
    • /
    • pp.173-179
    • /
    • 2009
  • Recently, the super capacitor(EDLC) which has drawn attention as a new energy storage element has a lot of advantage such as no maintenance, long lifetime and quick charge/discharge characteristics with large current. The objective of this paper is propose a parameter measurement method to detect the changes in equivalent series resistor (ESR) and the capacitance value of a super capacitor in order to analysis the internal characteristic and worn-out state of a super capacitor. For proposed method, only the capacitor voltage measurement using simple analog switch is required. In addition, experimental results of voltage sag compensation system in order to compensate the input voltage drop during short-term power interruption adopted super capacitor are presented.

  • PDF

Experimental Study of the Ultrasonic Vibration Effects on CHF Occurring on Inclined Flat Surfaces (초음파 진동이 경사진 평판에서의 CHF에 미치는 영향에 대한 실험연구)

  • 정지환;김대훈;권영철
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.139-144
    • /
    • 2003
  • Augmentation of CHF by ultrasonic vibration in water pool is experimentally investigated under pool boiling condition. The experiments are carried out using copper coated plates and distilled water. Measurements of CHF on flat plate heated surface were made with and without ultrasonic wave and with variations in inclined angle of the surface and water subcooling. Experimental apparatus consists of a bath, power supply, test section, ultrasonic generator, and data acquisition system. The measurements show that ultrasonic wave enhances CHF and its extent is dependent upon inclination angle as well as water subcooling. The rate of increase in CHF increases with an increase in water subcooling while it decreases with an increase in inclination angle. Visual observation shows that the cause of CHF augmentation is closely related with the dynamic behavior of bubble generation and departure in acoustic field.

A Pilot Study on Nondestructive Assessment of Compressive Strength Using Impact Force Response Signal (충격력 응답신호를 이용한 비파괴 압축강도 산정에 관한 기초연구)

  • Son, Moorak;Choi, Yoonseo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.4
    • /
    • pp.5-9
    • /
    • 2019
  • This paper is to provide the results of a pilot study of the usability and possibility of impact force response signal induced from impacting an object for the assessment of compressive strength of various materials (rock, concrete, wood, etc.) nondestructively. For this study, a device was devised for impacting an object and measuring the impact force. The impact was carried out by an initial rotating free falling impact and following repetitive impacts from the rebound action which eventually disappears. Wood and rock test specimens for different strengths were tested and an impact force response signal was measured for each test specimen. The total impact force signal energy which is assessed from integrating the impact force response signal was compared with the directly measured compressive strength for each specimen. The comparison showed that the total impact force signal energy has a direct relationship with the directly measured compressive strength and the results clearly indicated that the compressive strength of construction materials can be assessed nondestructively using total impact force signal energy which is assessed from integrating the impact force response signal induced from impacting an object.

Study on Non-destructive Assessment of Compressive Strength of Rock Using Impact Force Response Signal (타격력 응답신호를 이용한 암석의 비파괴 압축강도 산정방법에 관한 연구)

  • Son, Moorak;Seong, Jinhyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.10
    • /
    • pp.13-19
    • /
    • 2022
  • This paper is to provide the results of usability of the impact force response signal induced from initial and successive rebound impacting a rock specimen for assessing the compressive strength of rock non-destructively. For this study, a device was devised for impacting a rock specimen and a system for measuring the impact force was set up. The impact was carried out by an initial rotating free falling impact and following repetitive impacts from the rebound action which eventually disappears. Three different kinds of rock specimen were tested and an impact force response signal was measured for each test specimen. The total impact force signal energy which is assessed from integrating the impact force response signal induced from initial and rebound impacts was compared with the directly measured compressive strength for each rock specimen. The comparison showed that the total impact force signal energy has a direct relationship with the directly measured compressive strength and the results clearly indicated that the compressive strength of rock can be assessed non-destructively using total impact force signal energy.

Reactive Ion Etching을 이용한 PTFE 발수특성

  • Baek, Cheol-Heum;Seo, Seong-Bo;;Kim, Hwa-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.292-292
    • /
    • 2013
  • 최근, 자연의 기능성 표면을 모사하여 우리 생활에 응용하기 위한 연구가 활발하다. 초-발수 특성을 가지는 대표적인 예인 연꽃잎은 마이크로-나노 크기의 거친 미세돌기(papillae)를 가지고 있으며 그 위에 낮은 표면 에너지를 가지는 왁스(wax)가 발달 되어 항상 깨끗한 상태를 유지한다. 본 실험에서는 이를 모사하여 RIE (Reactive Ion Etching)방법을 이용하여 기판인 Poly silicon wafer를 Sf6가스를 사용하여 Metal mash로 거칠기를 만들어 주었고, RF-magnetron sputtering 장치를 사용하여 $6{\times}10^{-3}$ Torr의 진공도에서 낮은 표면에너지를 가지는 PTFE (polytetrafluoroethylene)를 증착하여 표면 구조와 발수특성에 대하여 조사하였다. SSME(Surface shape measurement equipment)측정결과 0.24~0.36 um RSa 값이 측정되었고, 12 uL의 Di-water로 접촉각을 측정 한 결과 RIE 10분 처리를 한 기판 위에 PTFE를 3분 증착하였을 때 가장 높은 $153^{\circ}$의 초-발수 특성이 나타났으며, 4주의 시간이 지났을 때에도 접촉각이 유지가 되었다. XPS 측정결과 초-발수 표면에서 나타나는 CF2와 CF3 피크 값이 측정되었다. Reactive Ion Etching을 이용한 PTFE 발수 특성은 방수, 스마트 윈도우, 자가세정(Self-Cleaning), 디스플레이 표시장치, 김서림 방지(Anti-Fogging), 대전방지 코팅 등에 다각적으로 응용 가능할 것이라 사료된다.

  • PDF

The study on the power quality measurement using wavelet transform in the grid-connected photovoltaic system (웨이브렛 변환을 이용한 태양광 발전시스템의 power quality 측정에 관한 연구)

  • Kim, Il-Song
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.51.1-51.1
    • /
    • 2010
  • 본 논문에서는 wavelet 변환을 이용하여 태양광 발전 시스템의 계통 전원 고조파를 측정하는 방법을 연구하였다. PCS(Power Conditioning System)는 태양전지의 전력을 교류로 변환하여 계통에 연계시키는 장치이다. 직류에서 교류로 변환할 때 스위칭 노이즈가 발생하고, 전력품질이 약화되게 된다. Wavelet 이론은 시간 파형을 주파수 성분으로 분해할 수 있는 기술이다. 이중에서 MLD(Multi-evel Decomposition)기법은, 계산량이 적으면서도 빠른 시간 내에 고조파 성분들을 알아낼 수 있다. 시스템 모델링과 wavelet 이론 소개, 그리고 컴퓨터 모의실험과 DSP 제어기를 이용한 실험 결과로서 본 연구의 타당성을 입증하였다.

  • PDF

초음파-메쉬를 이용한 분진 최소 착화에너지 측정 장치의 개발

  • ;;M. Takeuchi;M. Yamaguma
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.11a
    • /
    • pp.96-100
    • /
    • 2000
  • 과거에는 정전기에 의한 분진 폭발이 사이로 등을 이용해 대량의 분진을 취급하는 기업에서만 발생하는 것으로 인식되어졌다. 그러나, 근래에 와서 정전기에 의한 분진 폭발은 그 취급하는 양에 관계없이 기업의 보편적인 관심의 대상이 되고 있다. 분진 폭발을 방지하기 위한 계획에는 취급 분진의 최소 착화 에너지(Minimum Ignition Energy: 이하 MIE라고 함)측정이 필수적으로 요구되어진다[1].(중략)

  • PDF

Prediction of Slagging Behavior of Coal Ash in Gasifier using DTF (DTF를 이용한 가스화기에서 석탄회의 Slagging 성향 예측에 관한 연구)

  • 정석우;김형택;이시훈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.22-27
    • /
    • 1994
  • 6종류의 유연탄을 대상으로 석탄회분의 용융온도와 화학적조성을 측정하고, 대상탄 회분에 대해 Rs 값과 Fs 값을 계산해 봄으로써 각 탄들의 Slagging 성향을 알아보았다. 그리고, 이 자료만으로는 정확한 Slagging 성향의 예측이 어려우므로 분류층 가스화기의 조건을 모사한 DTF(Drop Tube Furnace : 이하 DTF)장치를 이용하여 온도와 체류시간을 달리하면서 생성되는 Slag의 화학적조성, 강도, 점착속도 등을 측정하여 Slagging 형태의 가스화기 운전에 있어서 최적조건을 제시하고자 한다.

  • PDF

A Study of far infrared rays production by ocher Illumination cap (황토 조명등을 이용한 원적외선 발생 연구)

  • 김원섭;윤영근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.191-195
    • /
    • 2003
  • 우리는 황토 조명등을 제작하여 원 적외선 발생 실험을 하였다. 실험에는 백열전구 200W, 실내온도 21도, 습도 38%의 조건에서 열화상실험과 TF-IR(적외선 분광방사 측정장치)에 의한 원적외선 방사한도를 측정하였으며, 그 결과 방사율 0.914와 방사에너지 6.23$\times$$10^2$ (w/$m^2$.$\mu\textrm{m}$) 가 얻어졌다. 이와 같은 결과로 황토조명등에서 원적외선이 발생한 것을 확인하였다.

  • PDF