• Title/Summary/Keyword: 에너지 창

Search Result 321, Processing Time 0.027 seconds

A Study on Heat Transfer Performance of Horizontal Ground Heat Exchanger (수평형 지중열교환기의 열전달 성능에 관한 연구)

  • Chung Minho;Park Seongryong;Ra Hosang;Baik Youngjin;Yoon Hyungkee;Chang Kichang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.684-687
    • /
    • 2005
  • Ground source heat pump systems are used for heating, ventilating and air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. The solar heat and the rainwater are affected by the performance of heat exchanger and causes mutual influence among heat exchangers. In this study, to evaluate the performance of straight type, slinky type, and spiral type of horizontal ground heat exchangers designed on 1 RT scale, test sections are buried on the earth and experimental apparatus is installed. Therefore the performance of these is estimated.

  • PDF

Design of a High Temperature Production Heat Pump System Using Geothermal Water at Moderate Temperature (중온 지열수를 이용한 고온제조 열펌프 시스템 해석 및 설계)

  • Kim, Min-Sung;Baik, Young-Jin;Park, Seong-Ryong;Chang, Ki-Chang;Lee, Young-Soo;Ra, Ho-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.638-641
    • /
    • 2008
  • Geothermal water at moderate temperature in a range between 30 to $50^{\circ}C$ exists sparse in surroundings. Mostly they are utilized as heat or water source at spar zones in Korea. However, a large portion of used water is discarded due to its poor recovery quality and inferior application technologies. In this research, an innovative heat pump system based on the hybrid concept that combinate compression cycle and absorption cycle was investigated mathematically. The hybrid heat pump aims to recycle various kind of the heat sources at moderate temperature including geothermal water effectively. The prime objective of the simulation is to design a compression/absorption hybrid heat pump system which can make high temperature above the level of $90^{\circ}C$ and low temperature of $20^{\circ}C$ as well at the same using $50^{\circ}C$ geothermal heat water. As a result, primitive data was provided as a basis to design a prototype 3 RT class hybrid heat pump.

  • PDF

A Study on Performance of Vertical Ground Heat Exchanger for Heat Pump (히트펌프용 수직형 지중열교환기의 성능에 관한 연구)

  • Chang, Ki-Chang;Chung, Min-Ho;Yoon, Hyung-Kee;Ra, Ho-Sang;Yoo, Seong-Yeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.466-469
    • /
    • 2007
  • Heat pumps are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. And a vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double n-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

Evaluation of seasonal performance for single-stage desalination system with solar energy (1단 증발식 해수담수화 시스템의 계절별 성능 평가)

  • Kwak, Hee-Youl;Joo, Hong-Jin;Joo, Moon-Chang;Kim, Jung-Bae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.221-226
    • /
    • 2008
  • This study was carry out evaluation of seasonal performance for the decentralized desalination system with the solar thermal system and the photovoltaic power system. First operating demonstration system was set up in Cheju in 2006. These system comprises the desalination unit with designed daily fresh water capacity of $2m^3$ and is supplied by a $120m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank, and a 5kW photovoltaic power generation supply the electricity for hydraulic pumps to move the working fluids. In a spring season day average $392W/m^2$, the daily fresh water showed to produce about 340liter. In a summer season day average $296W/m^2$, the daily fresh water showed to produce about 328liter. In a autumn season day average $349W/m^2$, the daily fresh water showed to produce about 277liter. In a winter season day average $342W/m^2$, the daily fresh water showed to produce about 271liter.

  • PDF

Control Algorithm for Wind Turbine Simulator with Variable Inertia Emulation (가변관성 모의 기능을 가진 풍력터빈 시뮬레이터의 제어 알고리즘)

  • 정병창;정세종;송승호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.266-273
    • /
    • 2003
  • A wind turbine simulator is developed for the emulation of variable input torque from the wind energy without actual rotor blades using motor-generator set. The torque command of dc motor is calculated from the characteristic equation of rotor blade during the change of wind speed. Especially the proposed control algorithm takes into account the fact that the moment of inertia of blade is much larger than that of driving motor. If you select the desired value of inertia, the stored/restored energy of the inertia during acceleration/deceleration can be compensated effectively resulting the only net torque is delivered to the generator. The simulator set-up has been designed and implemented using a do motor and drive. Feasibility of the proposed algorithm is verified by computer simulations and experiments.

Electrical Properties of Transparent Indium-Tin-Zinc Oxide Semiconductor for Thin-Film Transistors

  • Lee, Gi-Chang;Choe, Jun-Hyeok;Han, Eon-Bin;Kim, Don-Hyeong;Lee, Jun-Hyeong;Kim, Jeong-Ju;Heo, Yeong-U
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.159-159
    • /
    • 2008
  • 투명전도체 (transparent conducting oxides: TCOs) 는 일반적으로 $10^3\Omega^{-1}Cm^{-1}$의 전도도, 가시광 영역에서 80%이상의 투명성을 가지는 재료로서, 액정 박막 표시 장치(TFT-LCD), 광기전성 소자, 유기 발광 소자, 에너지 절약 창문, 태양전지(sollar cell) 등 전극으로 사용되고 있다. 최근에는 TCO의 전도도특성을 조절하여 반도성특성을 가진 투명 산화물 반도체(transparent oxide semiconductor: TOS) 을 이용한 박막 트랜지스터 연구가 활발히 진행 중이다. 기존의 실리콘을 기반으로 하는 박막 트랜지스터의 낮은 이동도, 불투명성의 특성을 가지고 있지만, 산화물 박막트랜지스터는 높은 이동도를 발현 할 수 있을 뿐만 아니라, 넓은 밴드갭 에너지를 갖는 산화물을 이용하므로 투명한 특성도 발현 할 수 있어 차세대 디스플레이의 구동소자로서 응용연구가 되고 있다. 이에 본 연구에서는 박막트랜지스터 channel layer로서의 Indium-Tin-Zinc oxide 적용특성을 조사하였다. Indium, Tin, Zinc 의 혼합비율을 다양하게 조절하여 타겟을 제작하였다. 이를 RF magnetron sputtering 를 이용하여 박막으로 성장시켰으며, 기판으로는 glass 기판을 사용하였다. 박막 성장시 아르곤과 산소의 비율을 다양하게 조절하였다. 성장시킨 박막은 Hall effect, Transmittance, Work function, XRD등을 이용하여 전기적, 광학적, 구조특성을 평가하였다. Indium-Tin-Zinc Oxide(ITZO) 을 channel layer로 사용하여 Thin-film transistor 을 제작하여, TFT의 I-V 및 stability특성을 평가하였다.

  • PDF

A Study on the Operating Characteristics by Counter Flow and Parallel Flow in Separate Heat Pipe Exchanger (분리형 히트파이프식 열교환기에서 향류 및 병류유동에 따른 가동특성에 관한 연구)

  • 이기우;장기창;유성연
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.44-56
    • /
    • 1998
  • Separate heat pipe exchanger is considered as the high thermal transportation equipment, because evaporator and condenser are separately positioned in the long distance. Its characteristics are that the working fluid is circulated naturally by the position height of two exchangers. But the operating characteristics are restricted by the temperature of hot and cold fluid, flow pattern and diameter of vapor line, etc. in this study, the vapor pressure and the minimum height of two exchangers are studied about the factors restricting the operating characteristics.

  • PDF

28 GHz 초전도 ECRIS의 마이크로파 전파 특성 및 이를 이용한 시스템 설계

  • Wang, Seon-Jeong;Won, Mi-Suk;Lee, Byeong-Seop;An, Chan-Yong;Kim, Seon-Ho;Gwak, Jong-Gu;Jeong, Seung-Ho;Kim, Seong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.134-134
    • /
    • 2010
  • KBSI 부산센터에 건설중인 소형의 다중 양전하 중이온 가속기에 사용될 초전도 ECR 이온온은 최대 자기장 3 T, 최소 0.5 T의 자기 Mirror구조를 가지고 있으며 중심 부근의 1 T 자기장에서 28 GHz 전자공명에 의해 마이크로파의 에너지를 플라즈마로 전달한다. 최대 10 kW의 Gyrotron에서 TE02 모드로 발생하는 마이크로파는 모드변환기, 직류차단기 및 진공창을 통하여 플라즈마로 입사된다. 32.5 mm 지름의 원형 도파관에서 자기장 축방향으로 도입된 TE01 모드의 마이크로파를 Altar-Appleton-Hartree 분산관계식을 이용하여 군속도의 관점에서 살펴보았다. 플라즈마 밀도가 Cut-off에 근접하지 않는 한 마이크로파의 바깥 방향으로의 회절은 크지 않았으며, 전자공명 위치로 접근함에 따라 군속도의 방향이 바뀌어 오히려 중심 방향으로 향함을 알 수 있다. 즉 마이크로파가 플라즈마 챔버의 벽을 가열시킬 가능성은 크지 않은 것이다. 또한 뜨거운 전자 플라즈마의 Susceptibility를 이용하여 마이크로파의 플라즈마로의 전자 공명에 의한 흡수를 살펴본 결과, 운전 영역에 속하는 전자밀도가 제공되면 공명 지점에 이르기 전에 충분히 흡수되는 것을 확인하였으며, 이에 따라 챔버를 관통하여 인출부 벽에 충돌하는 마이크로파 에너지는 무시할 수 있을 것으로 보여진다. 이 결과들을 토대로 마이크로파 시스템을 설계 완료하였다.

  • PDF

A Study on the High Efficiency Ground Source Heat Pump System (1) (부하추종형 고효율 지열히트펌프 시스템에 관한 연구 (1))

  • Koh, Deuk-Yong;Kim, Ook-Joong;Choi, Sang-Kyu;Chang, Ki-Chang
    • New & Renewable Energy
    • /
    • v.1 no.4 s.4
    • /
    • pp.30-37
    • /
    • 2005
  • Cycle simulation of Ground Source Heat Pump[GSHP] system was carried out to determine the design specification of basic components such as turbo compressor and heat exchangers. Part load operation characteristics of the designed GSHP system was estimated using the compressor and heat exchanger performance data. A 50RT class turbo compressor for GSHP system is now under development, in which R134a refrigerant is adopted as working fluid. The compressor with variable cascade diffusers is designed to work both in cooling and heating modes so that it can actively keep up with the climate change with high efficiency. The normal running speeds of the compressor are 59000rpm for heating mode and 70000rpm for tooling mode respectively. It has two identical impellers at both ends of the rotor so as to minimize aero-induced thrust force effectively. GSHP system was coupled with a vortical type heat exchanger, and heat gain and heat loss from ground were evaluated per a bore hole. For the optimal integration of the heat pump system, its header for circulating fluid was combined with the ground heat exchangers in parallel and series configuration.

  • PDF

Routing Hole Detour Scheme Based on Geographic Routing in Wireless Sensor Networks (무선 센서 망에서 위치 정보 기반 라우팅 홀 우회 방안)

  • Yu, Fu-Cai;Choi, Young-Hwan;Park, Soo-Chang;Lee, Eui-Sin;Tian, Ye;Park, Ho-Sung;Kim, Sang-Ha
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10d
    • /
    • pp.225-229
    • /
    • 2007
  • 센서 망에서 비어 있는 공간(홀)은 현실의 다양한 지리적인 환경 때문에 회피하는 것이 쉽지 않다. 일반적으로 데이터 패킷이 홀 경계에 마주쳤을 경우, 목적지까지의 다른 길을 찾기 위해 라이트 핸드 법칙(right hand rule) 또는 푸쉬드 백(pushed back)을 이용하여 홀 경계를 따라 패킷을 전달한다. 한편, 라이트 핸드 룰은 홀 경계에 있는 노드들의 에너지를 더 많이 소모하므로 홀이 확장될 것이다. 또한 동시에 여러 통신 세션이 같은 홀의 경계를 공유한다면 데이터 충돌을 초래할 것이다. 이 논문에서 우리는 무선센서 망에서의 홀 문제를 해결하기 위해 라우팅 홀 우회 방안을 제안한다. 우리의 라우팅 홀 우회 방안은 두 가지 목표를 갖는다: 하나는 데이터 패킷이 홀의 경계를 따라 이동하는 것을 방지하는 것이고, 다른 하나는 로컬 미니멈(local minimum) 문제를 피하는 것이다. 시뮬레이션 결과는 우리의 방안이 다른 프로토콜들에 비해 제어 부하와 에너지 소비 면에서 우수하다는 것을 보여준다.

  • PDF