• Title/Summary/Keyword: 에너지 절감량

Search Result 439, Processing Time 0.028 seconds

A Study on the Performance Analysis of AIoT High-Efficiency Streetlamp for Carbon Emissions (탄소배출권용 AIoT 고효율 가로등 성능분석 연구)

  • Seung-Ho Park;Seong-Uk Shin;Kyung-Sunl Yoo
    • Journal of Advanced Technology Convergence
    • /
    • v.2 no.4
    • /
    • pp.13-19
    • /
    • 2023
  • Following the signing of the Paris Agreement on Climate Change (UNFCCC, 2015), the world is expanding greenhouse gas reduction activities through comprehensive participation that includes not only developed countries but also developing countries. Major countries around the world are placing high expectations on the effectiveness of total carbon emissions regulation through the carbon emissions market. However, in order to obtain carbon credits, third-party verification is required based on quantitative carbon reduction data. Accordingly, in this paper, we developed an AIoT high-efficiency street light for carbon emissions and conducted a performance analysis study to measure the luminous efficiency of the lighting fixture. To obtain carbon emissions rights, we used high-efficiency LED PKG, developed our own high-voltage PFC, and developed high-efficiency lighting fixtures capable of communication. For communication, the 2.4GHz LoRa method was adopted between the lighting fixture and the gateway. Lens design was conducted through simulation of Korea Expressway Corporation's standard streetlight types A, B, and C. The performance of the streetlight was verified as being more efficient than other existing products through the measurement of luminous efficiency by an accredited rating agency, and it is expected that carbon emissions rights will be obtained by reducing electrical energy through this.

Dehumidification and Temperature Control for Green Houses using Lithium Bromide Solution and Cooling Coil (리튬브로마이드(LiBr) 용액의 흡습성질과 냉각코일을 이용한 온실 습도 및 온도 제어)

  • Lee, Sang Yeol;Lee, Chung Geon;Euh, Seung Hee;Oh, Kwang Cheol;Oh, Jae Heun;Kim, Dea Hyun
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.337-341
    • /
    • 2014
  • Due to the nature of the ambient air temperature in summer in korea, the growth of crops in greenhouse normally requires cooling and dehumidification. Even though various cooling and dehumidification methods have been presented, there are many obstacles to figure out in practical application such as excessive energy use, cost, and performance. To overcome this problem, the lab scale experiments using lithium bromide(LiBr) solution and cooling coil for dehumidification and cooling in greenhouses were performed. In this study, preliminary experiment of dehumidification and cooling for the greenhouse was done using LiBr solution as the dehumidifying materials, and cooling coil separately and then combined system was tested as well. Hot and humid air was dehumidified from 85% to 70% by passing through a pad soaked with LiBr, and cooled from 308K to 299K through the cooling coil. computational Fluid Dynamics(CFD) analysis and analytical solution were done for the change of air temperature by heat transfer. Simulation results showed that the final air temperature was calculated 299.7K and 299.9K respectively with the deviation of 0.7K comparing the experimental value having good agreement. From this result, LiBr solution with cooling coil system could be applicable in the greenhouse.

A Study on Nutritional Intake Status and Health-related Behaviors of the Elderly People in Gyeongsan Area (경산시 노인의 영양섭취상태 및 건강관련인자에 관한 연구)

  • Yang, Kyung-Mi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.1018-1027
    • /
    • 2005
  • The purpose of this study was to investigate nutrients intake and health-related behaviors in elderly people residing in Gyeongsan-si, Gyeongbuk who have no problem in daily living. Information on general characteristics of the elderly, health-related behaviors and dietary habits were obtained by interview based on questionnare. Dietary nutrients intake data were obtained through the 24 recall method. The subject group of this study was composed of 113 males and 112 females, the average age being $73.1\pm6.06$ years old. In health related factors, $76.9\%$ of subjects exercised regularly. The rates of alcohol drinking and smoking showed to be $38.2\%\;and\;22.2\%$, respectively. There were many elderly with neuralgia, hypertension, and gastrointestinal disease, especially female were worse. Average heights of the subjects were lower than the standard established in the Korean Recommended Dietary Allowances, and average weights were similar to the standards. The mean BMI and WHR were 24.8 (male 23.7, female 25.7) and 0.92 (male 0.92, female 0.89), respectively. Most of the subjects had a regular meal pattern comsuming three meals a day, and many elderly, especially more than $79.5\%$ of female, prepared the meals for themselves. Mean daily energy intakes and RDA percentage of energy intakes of the male and female subjects were estimated as 1426.9kcal $(79.3\%)$ and 1381.3 kcal $(86.3\%)$, respectively. Mean daily intakes of nutrients were estimatied as 48.1g for protein, 411.3mg for calcium, 8.05mg for iron, 541.8 R.E. for vitamin A, 0.84mg for vitamin $B_1$, and 0.79mg for vitamin $B_2$. Most nutrients except protein, clacium, iron and vitamin $B_2$ were consumed over $75\%$ of the RDA. Female elderly showed significant lower intakes (p<0.05) for most of the nutrients except calcium, phosphorus and vitamin ethan the elderly male.

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

The Effects of Different Crude Protein Levels in Same Methionine and Lysine Diet on the Performance of Laying Hens (동일한 Methionine과 Lysine수준의 사료에서 단백질수준이 산란계의 생산성에 미치는 영향)

  • 이상진;김삼수;정선부;곽종형;이규호;강태항
    • Korean Journal of Poultry Science
    • /
    • v.18 no.2
    • /
    • pp.67-84
    • /
    • 1991
  • The purpose of this study was to investigate the effects of dietary protein levels on laying hen performance. The level of methionine and lysine were 0.32% and 0.64%, respectively and the levels of protein were 12%, 13%, 14% or 15%. Total 384 laying pullets of 22weeks age were reared from January 28, 1989 to March 23, 1990 for 60 weeks. The results obtained were summarized as follows : 1 Egg productions was highest at 15% of protein in phase I, 14% in phase II, and 13% in phase III, and there was significantly different egg Production among treatments during phase I and phase II (P<0.05). 2. Egg weight was heaviest in 14% of protein treatment in three phases and they showed significantly different egg weight among different levels of protein in phase I (P<0.01), phase II and III (P<0.05) , but there was not significantly different between 14% and 15% of protein. 3. Daily egg mass tends to increase followed by increasing of protein level and showed signifiant differences among treatments in phase I and phase II (P<0.01). 4. The 14% of protein treatment showed the highest daily feed intake and it showed significant difference in phase I and phase II (P<0.01) , but there was no significant difference between 14% and 15% of protein. 5. Feed efficiency was improved significantly followed by increasing of protein level in phase I (P<0.01) and phase II (P<0.05), but there was no significant difference among treatments in phase III. 6. Viability tends to increase as increasing of protein level, but there was no significant difference among treatments. 7. Utilizabilities of dry matter, crude protein and ether extract of experimental diets were not different among treatments, but the utilizability of carbohydrate tends to increase as increasing of protein level (P<0.05). 8. Eviscerated yield and abdominal fat accumulation was not difference among treatments. 9. Egg shell quality and chemical composition of egg content were not different among treatments. 10. The feed cost per kg egg mass showed the cheapest in 13% of protein treatment in all phase, but there were no significant differences among treatments.

  • PDF

Studies for Development of Freeze - Flow Process (Freeze - Flow Process 개발을 위한 기초연구)

  • Lee, Young-Chun;Shin, Dong-Bin
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.495-499
    • /
    • 1985
  • To develope a process by which liquid foods can be stored in the liquid state at the frozen storage temperature, suitable cryoprotectants were selected. Orange juice, chosen as an example of liquid foods, was stored with combined cryoprotectants at $-15^{\circ}C$, and quality changes of orange juice during storage were evaluated. Among 7 cryoprotectants tested, NaCl solution had lower initial freezing point than others, and initial freezing points of glucose, fructose, glycerol, propylene glycol and citric acid were close to each other. Considering flavor quality of orange juice, cryoprotectants suitable for reducing freezing point of orange juice were glucose, fructose, glycerol, and citric acid. Combined cryoprotectants for reducing freezing point of 3 and 4 folds concentrated orange juice to $-15^{\circ}C$ consisted of 10% glucose, 8% frutose, 4.6% glycerol and 3% citric acid, and 5.5% glucose, 4.5% fructose, 4.6% glycerol, and 3% cirtric acid, respectively. When destruction of ascorbic acid, sedimentation volume and sensory flavor score of orange juice stored with combined cryoprotectants at $-15^{\circ}C$ and the control stored at $-18^{\circ}C$ were compared, there were no significant differences. These results indicated that liquid foods with suitable combined cryoprotectants could be stored at $-15^{\circ}C$ or below in the liquid state without adverse effect on quality of the stored products.

  • PDF

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.

Development of Robotic Inspection System over Bridge Superstructure (교량 상판 하부 안전점검 로봇개발)

  • Nam Soon-Sung;Jang Jung-Whan;Yang Kyung-Taek
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.180-185
    • /
    • 2003
  • The increase of traffic over a bridge has been emerged as one of the most severe problems in view of bridge maintenance, since the load effect caused by the vehicle passage over the bridge has brought out a long-term damage to bridge structure, and it is nearly impossible to maintain operational serviceability of bridge to user's satisfactory level without any concern on bridge maintenance at the phase of completion. Moreover, bridge maintenance operation should be performed by regular inspection over the bridge to prevent structural malfunction or unexpected accidents front breaking out by monitoring on cracks or deformations during service. Therefore, technical breakthrough related to this uninterested field of bridge maintenance leading the public to the turning point of recognition is desperately needed. This study has the aim of development on automated inspection system to lower surface of bridge superstructures to replace the conventional system of bridge inspection with the naked eye, where the monitoring staff is directly on board to refractive or other type of maintenance .vehicles, with which it is expected that we can solve the problems essentially where the results of inspection are varied to change with subjective manlier from monitoring staff, increase stabilities in safety during the inspection, and make contribution to construct data base by providing objective and quantitative data and materials through image processing method over data captured by cameras. By this system it is also expected that objective estimation over the right time of maintenance and reinforcement work will lead enormous decrease in maintenance cost.

  • PDF

A Study on the Devitrification of Container Glass with the Amounts of Cullet (유리 용기 생산시 Cullet의 사용에 관한 연구)

  • Noh, Kwang-Hong;Kim, Jong-Ock;Kim, Taik-Nam;Lim, Dae-Young;Park, Won-Kyu;Lee, Chae-Hyun
    • The Journal of Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.199-205
    • /
    • 1998
  • Cullet Quality Control in auto glass bottle factory is the most important in recent days because of the increasing cost of materials in glass bottle. Since the composition of plate glass cullet is similar, the cullet quality using plate cullet in glass bottle factory is easily controlled. In addition to this, the price of plate glass cullet is so low that the cost reduction can be achieved. If the ratio of plate glass cullet and gush is over 25%, the liquidity of glass water become worse, which is caused by different compositions and viscosity of the components. As a results, Furnace bottom temperature becomes low and glass water becomes inhomogeneous. Thus production efficiency of glass bottle becomes low because of increasing devitrification in Dead Corner part in glass melting furnace. Three experimental methods – (1) increasing melting temperature, (2) using Booster, (3) using bubbler – were performed to increase the furnace bottom temperature and glass water homogeneity. The amounts of plate glass cullet was able to increase up to 90%, 70% and 60% without any devitrification using booster, bubbler and the method of glass melting temperature increase from $1480^{\circ}C$ to $1560^{\circ}C$ respectively. It is not possible to increase the glass melting temperature without the reduction of furnace operation time and the increase of fuel cost. The booster process has disadvantage of much electric energy consumption. Since the bubbler process uses physical convection of melting glass based on compression air, the homogeneity of molten glass is not so good as that of booster process but it can reduce the cost of glass bottle.

  • PDF