• Title/Summary/Keyword: 에너지 공급 설비

Search Result 319, Processing Time 0.025 seconds

CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump (지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축)

  • Lee, Geon-Woo;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.349-354
    • /
    • 2008
  • August 2008, Our country was announced the Energy Vision 2030 for strengthening response capability climate change by the greenhouse effect, 'Stable supply of energy' and 'Efficient systems'. According to the report, Our country is the world's top 10 is a country that consumes a lot of energy. and more than 97% of the energy because it is dependent on foreign imports, The importance of NRE(New and Renewable Energy) is rising significantly, This paper was applied geothermal heat pump it one kind of the renewable energy equipment, in General buildings, and analyzed the effect of the installation. Thus, to improve the load factor of the Electric power system was proposed, and As a result, can be expected the energy cost savings and the reduction of greenhouse gases, through Economic electric power supply.

  • PDF

Capacity Cost of Renewable Energy Considering Intermittence Problem (Intermittence Problem을 고려한 신재생에너지의 Capacity Cost)

  • Moon, Changkwon;Choi, Hyukjoon;Kang, Minju
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.133.2-133.2
    • /
    • 2011
  • 2012년 RPS 제도가 시행되게 되면 발전설비용량 기준 500MW이상의 발전 사업자는 전체 전력생산량 중 일정 부분을 신재생에너지로 생산, 공급해야 한다. 최근 지경부에서 고시한 제5차 전력수급기본계획에서도 이러한 점을 반영하여 2024년까지 전체 발전량의 8.9%를 신재생에너지원으로 대체하겠다고 발표하였다. 신재생에너지 기술 수준, 시장여건 등을 고려하였을 때 앞으로 가장 크게 보급량(penetration)이 증가할 것으로 보이는 신재생에너지원은 태양광과 풍력인데 이 두 에너지원은 간헐성(intermittency)으로 인한 비급전성이라는 특징을 가지고 있어 향후 그 비중이 증가하면 전력계통의 안정성에 미치는 영향에 대해 고려해야할 것으로 보인다. 본 연구에서는 태양광과 풍력의 간헐성을 고려했을 때 추가적으로 발생하는 비용을 고려했을 경우 각 에너지원의 용량비용은 어떻게 되는지 알아보고자 한다.

  • PDF

난방운전의 최적제어방안 중심 공동주택의 열성능 향상 방안

  • 이승언;안태경;강재식
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.74-89
    • /
    • 1994
  • 현재 범국가적 차원에서 지속적인 국가 경제 발전과 국제수지 개선을 위하여 추진되고 있는 정부의 에너지 절약사업에서 건물부문이 차지하는 에너지절약 효과는 막중하다. 특히 전체주택에서 공동주택이 차지하는 비율은 1990년에 32.1$\%$, 서울시의 경우 51.3$\%$로 전체 주택의 과반수를 넘어섰으며, 수도권의 대단위 아파트단지의 개발과 함께 공동주택의 증가추세는 당분간 지속될 전망이다. 본 연구는 공동주택의 최적난방 운전기법 개발을 위한 1차년도의 연구로서 현행 공동주택의 난방운전 실태를 조사, 분석하고 각 난방법에 따른 문제점 및 최적제어 알고리즘의 개발을 위한 자료 도출을 주 목적으로 진행되었다. 1차년도에 수행된 연구의 주요 내용을 살펴보면 다음과 같다. 공동주택의 난방에너지 소비현상은 단지에 따라 최대 3배이상의 열사용량에 차이가 있는 것으로 나타났다. 열사용량의 차이는 건축의 기본 열성능, 설비시설의 수준 및 노후화정도에 영향을 받으나 동일 연대의 단지들에서도 최대 80$\%$이상의 열사용량이 차이를 보이고 있었으며 이는 기계실 및 각 세대의 난방운전방법 및 제어수준에 따른 것으로 평가되었다. 세대의 층별, 위치별 열사용량 분석에 의하면 층별 열사용량차이가 큰 것으로 분석되었으며, 특히 최상층부와 최하층부의 열사용량이 뚜렷이 많이 나타나 단열성능의 강화가 요구되는 것으로 나타났다. 한편 샘플단지에 대한 측정 데이터를 통해 적정 열량공급시간대의 설정과 외기온의 변화에 따른 적정 온수공급온도의 설정조건 및 유량제어 효과등에 대한 분석 및 검토를 하였으며, 이를 통해 2차년도의 개발목표인 최적운전제어 방안의 제시를 위한 자료를 구축하였다. 또한 각 세대의 기밀성능이 공동주택의 열성능에 미치는 영향을 도출하기 위하여 샘플단지에 대해 트레스가스 측정법과 Blower Door법에 의하여 환기 및 기밀상태를 평가 하였으며 측정주호에 대한 환기를 예측할 수 있는 환기예측평가식을 제시하였다.

  • PDF

Integrated Building Energy Supply System : An Overview of Technical Trends for Gas Engine Driven Combined Heat and Power System (가스엔진 구동 건물에너지 통합 공급시스템 개발을 위한 기술동향 사례연구)

  • Park, Beungyong;Jeong, Yongdae;Shin, Hyunchul;Cho, Jinkyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.612-620
    • /
    • 2017
  • Power consumption in Southeast Asia is steadily increasing due to industrialization and the effects of hot and humid climates. However, there are not enough energy generation facilities and infrastructures to meet the growing demand because it is difficult to secure the construction and operation costs of the transmission and distribution systems. This study aims to develop a gas engine driven heat pump system that supplies heating, cooling and electric power to buildings. This system, besides its normal function to produce heat, has the capacity to generate electricity on a household level. This paper investigates similar cases overseas before developing the system. Through the investigation of commercialized similar systems, the level of technology and market trend of development system were identified. Features and specifications of commercial and industrial systems will be used for system development.

A Study on the Planning of Urban Energy Supply Systems Including Co-generation System (도시지역 에너지 공급체계 개선방안 검토 연구)

  • Woo, Nam-Sub;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.177-182
    • /
    • 2009
  • The purpose of this study is to investigate planning of urban energy supply systems configuration and operating conditions for the district heating and cooling system using combined heat and power system. Generally the district heating and cooling system has been known to one of the effective way for energy saving, cost reduction and demand side management of energy. Economical analyses were carried out and operating characteristics for some systems were examined in terms of GER factor which represents to the ratio of gas and electricity costs. Rates of the energy consumption and the $CO_2$ emission were compared from the system configuration of the energy supply system with new district cooling system with the conventional one.

  • PDF

국내 원자력 발전소의 운영현황과 전망

  • 박상기
    • 전기의세계
    • /
    • v.37 no.5
    • /
    • pp.3-8
    • /
    • 1988
  • 우리나라의 전력 사업은 1887년 경복궁내 건청궁에서 하나의 전등이 최초로 점화된 이후 100년이 경과하여 1988년 금년은 한국 전기의 2세기를 맞이하는 첫해가 되고 있다. 현재 한국이 보유하고 있는 전력생산 설비는 민간기업이 소유한 자가용 발전시설을 제외하고 총 1900만 kW에 달하고 있으며, 1987년도의 총 발전량은 785kWh에 이르러 전력수요성장은 전년도 대비 14%의 증가를 나타내고 있다. 특히, 이러한 전력 수요에 부응하기 위한 총 발전량의 53.1%의 393억kWh는 원자력 발전소에서 공급되었다는 사실은 경제성장과 사회문화의 발전에 따라 에너지 특히, 전력에너지의 역할이 더욱 중요해지고 있다는 점을 감안한다면 이미 원자력발전은 우리 경제 사회활동과 생활여건에 크게 영향을 미치고 있다는 현실로 인식할 필요가 있다.

  • PDF

Operational Characteristics of DC Reactor Type SFCL for Accident of Both Power Source Side and Load Side (전원단 및 부하단 사고에 따른 DC 리액터형 고온초전도 전류제한기 동작특성)

  • Lee, Su-Won;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.140-145
    • /
    • 2004
  • In this paper, we analyzed the operational characteristics of the modified DC reactor type SFCL and derived the design condition of superconducting coil to be operated properly as power source as well as fault current limiter. It was confirmed through the simulation for the operation of this SFCL that the modified DC reactor type SFCL could be operated as both the uninterruptible power supply and the fault current limiter by controlling the duty ratio of GTO thyristor bridge.

The Effects of Operating and Design Conditions on the Performance of Radiant Heating Panel (복사 난방 패널의 공급유량 및 설계변수가 성능에 미치는 영향)

  • Lee, Tae Won;Kim, Ho Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.276-285
    • /
    • 1991
  • The transient heat transfer characteristics in the radiant heating panel were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with respect to time were obtained. Heating hours per day, rate of energy supplied and maximum temperature differences at panel surface were also compared for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various operating and design conditions such as pipe pitch, pipe location, pipe diameter and flow rate of hot water for the purpose of producing useful data, which can be used for the test and decision of efficient operating condition of the conventional heating systems or the optimal design of the new panel heating systems.

  • PDF

KISA 초대석 - 영원한 무재해 발전소로 기억될 것 - 한국중부발전(주) 서울화력발전소 박형구 소장

  • Im, Dong-Hui
    • The Safety technology
    • /
    • no.178
    • /
    • pp.24-25
    • /
    • 2012
  • 한국중부발전(주) 서울화력발전소는 당인리발전소로 잘 알려진 우리나라 최초의 화력발전소다. 제4호기(137,500kW)가 준공된 1971년 당시에는 서울시 전력수요의 75%를 담당하는 등 우리나라 산업발전의 견인차 역할을 해왔다. 현재는 제4, 5호기 총 설비용량 387,500kW로 수도권 전력 공급의 중추적인 역할을 해오고 있는 것은 물론, 국내 최초 열병합발전소로서 여의도, 동부이촌동, 반포, 마포 지역의 5만 여 세대에 난방열과 온수를 공급하고 있다. 이외에도 1993년부터는 발전연료로 사용해온 유류를 천연가스로 전환하고, 2002년에는 질소산화물 저감설비를 설치해 대기환경오염 수치를 10분의 1로 낮추는 등 에너지 절약 및 환경보전에 대한 노력도 꾸준히 펼치고 있다. 이와 같이 우리나라 최고의 화력발전소로서 명성을 이어온 이곳은 지난 1980년 11월 7일부터 무재해를 이어오면서 무재해 23배수와 무재해일수 11,591일이라는 대기록을 달성했다. 이는 무재해 운동을 벌이고 있는 기업들 중 최장의 무재해기록이기도 하다. 그렇다면 이곳은 어떤 활동을 통해 무재해 사업장의 명맥을 이어나갈 수 있었을까. 한국중부발전(주) 서울화력 발전소의 박형구 소장을 만나 이야기를 나눠봤다.

  • PDF

마이크로 코제너레이션 시스템

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.300
    • /
    • pp.78-83
    • /
    • 2001
  • 미쓰비시電機가 제안하는 에너지솔루션은, 고객의 에너지절약, 코스트절약 및 환경개선의 파트너로서 현장에 밀착하여 에너지의 종합엔지니어링력(力)(에너지 발생$\cdot$공습$\cdot$이용기술)과 IT를 구사하여, 고객의 에너지와 관련된 여러 가지 과제(부분적인 과제에서 고객 전체의 에너지과제까지)에 대하여 에너지절약 컨설테이션, 설계시공, 설비리스, O&M, 에너지 공급, 에너지운용관리까지 폭넓게 고객과 함께 해결해 오고 있다. 그 일환으로서 동사는 마이크로 가스터빈의 코제너레이션 시스템''마이크로 에코터보 MTG-28''을 분산전원의 레퍼터리로서 제품화하고 동시에 분산전원에 의한 전$\cdot$열공급 서비스사업을 적극적으로 전개하고 있다. 동사는 Capstone사 제품인 28kW 마이크로 가스터빈을 이용하여 열이용을 포함한 코제너레이션 패키지를 개발하고 또한 고객의 큰 관심사항인 메인터넌스에 대해서도 24시간 원격감시하는 시스템을 실용화하여 애프터서비스 체제를 정비하고 있다.

  • PDF