• Title/Summary/Keyword: 에너지 공간

Search Result 1,727, Processing Time 0.027 seconds

Damage Detection in Floating Structure Using Static Strain Data (정적 변형률을 이용한 플로팅 구조물의 손상탐지)

  • Park, Soo-Yong;Jeon, Yong-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.36 no.3
    • /
    • pp.163-168
    • /
    • 2012
  • Recently, people's desire for the waterfront space has been increasing, and more people want to spend their leisure time close to the water. This paper proposes a damage detection technique using the static strain for the floating structure. An existing damage index, in which the modal strain energy was utilized to identify possible location of damage, is expanded to apply the static strain. The new damage index is expressed in terms of the static strains of undamaged and damaged structures. After calculating damage index, the possible damage locations in the structure are determined by the pattern recognition technique. The accuracy and feasibility of the proposed method is demonstrated by using experimental strain data from a scale model of floating structure.

Stream Data Processing based on Sliding Window at u-Health System (u-Health 시스템에서 슬라이딩 윈도우 기반 스트림 데이터 처리)

  • Kim, Tae-Yeun;Song, Byoung-Ho;Bae, Sang-Hyun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.2
    • /
    • pp.103-110
    • /
    • 2011
  • It is necessary to accurate and efficient management for measured digital data from sensors in u-health system. It is not efficient that sensor network process input stream data of mass storage stored in database the same time. We propose to improve the processing performance of multidimensional stream data continuous incoming from multiple sensor. We propose process query based on sliding window for efficient input stream and found multiple query plan to Mjoin method and we reduce stored data using backpropagation algorithm. As a result, we obtained to efficient result about 18.3% reduction rate of database using 14,324 data sets.

An Energy-Efficient Operating Scheme of Surveillance System by Predicting the Location of Targets (감시 대상의 위치 추정을 통한 감시 시스템의 에너지 효율적 운영 방법)

  • Lee, Kangwook;Lee, Soobin;Lee, Howon;Cho, Dong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.2
    • /
    • pp.172-180
    • /
    • 2013
  • In this paper, we propose an energy-efficient camera operating scheme to save energy which can be used for mass surveillance cameras. This technique determines how many cameras should be turned on in the consideration of the velocity vector of monitoring targets, which is acquired by DSRC object tracking, the model of the specification of installed cameras, and the road model of installed sites. Also, we address other techniques used to save energy for the surveillance system as well. Throughout performance evaluation, we demonstrate the excellence of our proposed scheme compared with previous approaches.

Energy Band Schemes in Organic Electroluminescent Devices Using Terbium Complexes Prepared by Vacuum Evaporation Method (진공 증착법에 의한 Terbium Comp1exes를 이용한 유기 전기 발광 소자의 에너지 밴드에 관한 연구)

  • 표상우;김옥병;이한성;최돈수;이승희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.582-588
    • /
    • 1999
  • 정보화 사회의 발전과 함께 멀티미디어에 대한 관심이 집중되고 있으며, 점유 공간이 작고 가벼우며 대면적이 가능한 정보 표시 디스플레이에 대한 기술은 고부가가치 산업으로 인식되어 지고 있다. 이러한 정보 표시 디스플레이들 중, 전기 발광 소자 (Electroluminescence Display : ELD), 액정 표시 디스플레이 (Liquid Crystal Display LCD), 플라즈마 디스플레이 (Plasma Display Panel) 등의 대한 연구가 세계적으로 매우 활발하게 진행되고 있다. 본 연구에서는 란탄 계열의 금속 착 화합물인 Tb(ACAC)$_3$(Phen)과 Tb(ACAC)$_3$(Phen-Cl)를 이용해 다비이스를 제작한후 광학적 및 전기적 특성을 조사하였다. 또한 luminous efficiency와 cyclic voltametric 방법을 이용해 에너지 밴드로 두 발광 물질인 Tb(ACAC)$_3$(Phen)과 Tb(ACAC)$_3$(Phen-Cl)을 비교.분석하였다. 본 연구의 디바이스 구조를 보면 anode/hole transporting layer (HTL)/emitting material layer (EML)/electron transporting layer (ETL)/cathode와 같고 ETL를 aluminum-tris- (8-hydroxyquinoline) (Alq$_3$)와 bis(10-hydroxybenzo(h)quinolinato)beryllium (Bebq$_2$)를 사용하였으며 HTL 로 N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1'-biphenyl-4,4'-diamine (TPD)를 사용하였다.

  • PDF

The Role of Reflected Sunlight in Daylighted Office Environment (사무공간의 자연채광에 있어 반사광의 효용성에 관한 연구)

  • Kim, Gon
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.35-43
    • /
    • 1997
  • An increase in the design of commercial buildings with daylighting is beginning to receive more attention, claimed by some as a second revolution in architecture. The benefits of daylighting may vary significantly because a characteristic of daylight is the way in which it varies. Indirect sunlight, however, received in the interior of a building after reflection, can serve a useful purpose as the main source of illumination. In a cloudy climate it can serve as an occasional welcome addition to the available skylight. Also, site constraints or surrounding urban context may necessitate using reflected light sources, or such sources may be an integral part of the overall design objectives and aesthetics of the proposed projects. When reflected sunlight is introduced into a space, its role in general illumination is what is of interest in this study. Results show that reflected sunlight may help the general illumination in almost same level of significance as daylight from diffuse sky. It is also summarized that the contribution of reflected sunlight to general illumination through the year round may be even and uniform regardless of the season. Consequently, introduction of reflected sunlight should be regarded as one of the successful means to enhance the visual environment in quantitative and qualitative way.

  • PDF

A study of Illumination on Floor Surface by Flat Form Louver of Top Lighting System (천창루버에 의한 내부공간 바닥면 조도변화와 설치방식에 관한 연구)

  • Kim, Mi-Hee;Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.132-138
    • /
    • 2011
  • Inducing the natural lighting into building has been commonly applied to the spaces where artistic objects are displayed to create better visual environment for the appreciation. The direct natural lighting, especially through top lighting system may, however, bring forth discoloing of highly light-sensitive materials such as paintings or demanding additional cooling load. In addition, it causes to create glare against appreciators or to yield in visual distraction due to the extreme contrast on the inner surfaces of the spaces. Shading device such as louver is capable of preventing such voidable cases with careful manipulation. This study aims to provide basic design guide-line when the flat-form louver has to be applied to top lighting system. Interaction between the daylight and louver was simulated by Reluxpro program with variation of the attachment location, the angle of the lover, surface reflectivity, to obtain the illumination of the floor surface. This study yields the louver just under the top lighting window with 90 degree angle gives the most desirable way of employment when the uniform illumination on the floor surface is required.

A Study on Analysis of Space Evaluation Using the Luminance Distribution Images (휘도분포영상을 이용한 공간평가분석에 관한 연구)

  • Han, Sang-Pil;Kim, Jong-Youn;Cho, Nam-Cheol;Yi, Yong-Kyu;Kim, Nam-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.76-81
    • /
    • 2013
  • In our former study, we proposed that the AC-Model might be applied to various conditions. And we also introduced the method for daylighting that it was possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. The purpose of this study was to examine the relationship between physical elements and psychological evaluation of lighting space. The study was made using an full-size space, which were equipped with various luminaries. We investigated the relationship between subjective evaluation and characteristics of light distribution and showed the high correlation between the evaluation rating and luminance distribution over whole room.

Design of Buck Converter Controller in the Photovoltaic Power Conditioning System (태양광 발전시스템에서의 벅 컨버터 제어기 설계)

  • Jung, Seung-Hwan;Choy, Ick;Im, Ji-Hoon;Choi, Ju-Yeop;An, Jin-Ung;Lee, Dong-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.377-382
    • /
    • 2009
  • modelling of the buck converter in photovoltaic power conditioning system is not a possibility of doing with input-output relationship from existing procedures. Because the input current and voltage of the buck converter in fluctuate at any time. The controller which design with the method which has like this error cannot have a good efficiency. In this paper, firstly, in order to design accurate controller of buck converter, new model is proposed. The modeling used a state-space averaging method and came to accomplish. Secondly, the process which design the controller is described. Finally, the simulation results are analyzed.

  • PDF

A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance (사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구)

  • Seo, Young-Seok;Oh, Min-Suk;Kim, Hway-Suh
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

The Impacts of Built Environmental Features on the Land Surface Temperatures for the Heat Wave Seasons in Gwangju, South Korea (도시화에 따른 건조환경이 하절기 광주시 외부공간의 열환경에 미치는 영향에 대한 연구)

  • Hong, Sung-Woon;Yang, Dongwoo;Oh, Byoung-Chull
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.67-82
    • /
    • 2019
  • This study aims to examine the impacts of built environmental features on the nocturnal and diurnal temperatures during the heat wave season in Gwangju, Korea. Built environmental measures are summarized at micro-scale level, such as 50 meters and 100 meters from temperature monitoring spots. Regressing the built environment on nocturnal and diurnal temperatures, we estimate how the artificial constructs contribute to temperature either day and night times. We found that impervious surface ratio is positively and negatively associated with nocturnal and diurnal temperatures, respectively. Buildings and structures tend to construct high thermal mass and absorb heat during day time and emit it for the night time. This property contributes to the nocturnal temperature model. On the other hand, urban areas with more vertical structure tend to block sun radiation more than rural, and it is more likely to find the negative relationship between impervious surface ratio and the diurnal temperatures.