• Title/Summary/Keyword: 에너지회수

Search Result 881, Processing Time 0.028 seconds

A Study on Increasing the Energy Recovery from Waste at Incheon Metropolitan City according to Landfill Tax Introduction (폐기물부담금제 도입에 따른 인천시 폐기물의 에너지화 제고방안 연구)

  • Lim, Jiyoung;Kim, Jinhan;Park, Junghwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.2
    • /
    • pp.21-27
    • /
    • 2015
  • An introduction of landfill tax has been recently in issue in order to raise the financial resource for establishing waste resource-circulation society. The objectives of this study are to evaluate the plan of increasing energy recovery from waste at Incheon Metropolitan City, and to propose several points to be considered in terms of introducing the landfill tax. There are a lot of problems that impede energy recovery from waste at Incheon Metropolitan City, such as high-calorific waste from decrease of food waste to the municipal incineration plant, metals and batteries in the standard plastic garbage bag, etc. Alternative policies to solve these major problems have been drawn.

Heat Pipe Heat Exchanger (히트파이프 열교환기)

  • 이영수;이기우
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.805-815
    • /
    • 1995
  • 히트파이프에 관한 연구는 구미, 일본 등 선진 각국뿐만 아니라, 중국, 독립국가연합 및 동구권 에서도 다년간 활발하게 진행되어 왔다. 석유파동 이후 에너지 절약을 위한 노력의 결과로 폐 열회수 장치가 많이 개발되면서 히트파이프를 전열소자로 사용한 폐열회수 장치가 상당히 늘어나 이에 소요되는 히트파이프의 생산량도 급격한 신장세를 나타내고 있다. 이는 히트파이프 자체가 응답성이 좋고, 구조가 간단하며, 전열성이 뛰어난 장점으로 인하여 많은 연구가 이루어졌기 때 문이라 하겠다.그 응용분야는 인공위성으로부터 폐열회수용 열교환기, 전기장치 전자소자의 냉각, 음향기기의 냉각, 태양열과 지열의 유효이용, 플라스틱 금형의 냉각, 공작기계의 주축냉각, 포장 기계, 주방기기, 전력케이블의 냉각, 엔진 및 브레이크의 냉각 등 응용분야가 광범위하여 급격 하게 발전하고 있다. 그러나 국내에서는 히트파이프와 관련된 학술적인 연구결과가 발표되고 있을 뿐, 체계적이며 지속적인 연구가 수행되지 못하고 있다. 또한 산업계에서도 관련제품의 대 부분을 수입에 의존하고 있으며, 일부 제작업체에서는 제품이 나오고 있으나 축적기술결여로 그 성능면에 있어서 보증이 어려워 업계의 연구개발에 대한 노력이 절실히 요구되고 있다.

  • PDF

Fouling Mitigation of Heat Exchangers (열교환기 Fouling의 저감 대책)

  • 이윤표;이신표
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.836-847
    • /
    • 1995
  • 파울링은 열교환기에 형성되는 열저항으로 에너지 손실에 많은 영향을 미친다. 그러나 파울링은 그 예측이나 감소 또는 제거가 매우 어려운 것으로 인식되어 왔다. 작동유체자체를 철결하게 유지함으로써 파울링을 감소할 수도 있으나 작동유체 자체의 특성 때문에 본질적으로 작동유체를 청결하게 유지할 수 없는 경우가 대부분이다. 즉, 폐열 회수의 대상이 되는 액체가 하천수나 생 활하수인 경우 작동액체를 청결하게 유지함으로써 파을링을 저감시피는 방법은 타당치 않다.일 본의 폐얼회수 프로젝트와 담수화 프로젝트에서 특이한 점은 두 가지 프로젝트에서 열교환기면의 파울링 문제 해경을 전열 촉진의 내용과 거의 비슷한 비중으로 다루고 있다는 점이다. 파울링은 오래 전부터 열시스템설계자의 주요 관심사였으나 큰 진전은 없었다. 그러나 현재는 주변기술이 발달로 더 이상 연구 불가능 영역은 아닐 듯 싶다.

  • PDF

Theoretical Analysis of a Recuperative Refrigeration Dehumidifier (열회수 냉각 제습기의 이론적 해석)

  • Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.1
    • /
    • pp.48-54
    • /
    • 2014
  • A refrigeration dehumidifier with a recuperative heat exchanger is theoretically analyzed. The recuperative heat exchanger is located between the two air streams from and to the dehumidifying coil, and reduces the sensible heat load in dehumidification process. A simple model is developed to predict performance of the dehumidifier. The model predicts that the recuperative heat exchanger is effective especially in the low humidity condition, where the sensible heat load is relatively large. It is predicted that, by adopting a recuperative heat exchanger, a maximum 30~110% increase in COP is possible for indoor air at $27^{\circ}C$, and 40~60% relative humidity.

고층 아파트의 최적 열공급 시스템

  • 민만기;최영돈
    • Journal of the KSME
    • /
    • v.32 no.3
    • /
    • pp.247-254
    • /
    • 1992
  • 이 글에서는 고충아파트에서 층간 열공급의 불균일성이 발생하는 원인을 설명하였고 이 불균일 성을 해소시키는 새로운 열공급 설비 기술을 설명하였으며 그 내용들에 대한 결론은 다음과 같다. (1) 온수 난방 고층아파트의 층간 열공급의 불균일성은 온수공급관과 회수관의 정수압력의 차 이에 의한 유동저항에 의해서 발생한다. (2) 다구역배관망 시스템은 온수공급관과 회수관의 정수압력의 차이에 의해 발생하는 열공급 불균일성의 해소에 거의 기여하지 못한다. (3) 연속난방방식에서 서모스타트의 설치는 각세대의 열공급을 균일하게 할 수 있고 에너지 절 약면에서 가장 유리한 방식이나 고장의 위험성이 가장 크며, 운전의 미숙에 의한 열공급 제어의 불균일성을 초래하기 쉬우며 외기온도가 매우 낮으면 층간 열공급제어가 되지 않을 수 있어서 자동유량조절밸브를 병용하거나 온수공급압력을 충분히 크게 할 필요가 있다. (4) 자동유량조절밸브에 부착하면 단구역 배관망 시스템에서도 층간의 유량공급의 불균일성을 없앨 수 있으나 순환 펌프유량이 부족하면 밸브의 자동유량조절 기능이 상실된다. (5) 수동유량조절밸브는 TAB에 의해서 충간의 유량을 균일하게 조절할 수 있으나 펌프 성능변화 관부식 등이 발생하면 TAB를 다시 할 필요가 발생할 수 있다. 그러나 밸브의 고장이 적고 유 동저항을 적게 발생시키며 한 개의 밸브로 조절할 수 있는 유량의 범위가 큰 점에서는 가장 유 리하다.

  • PDF

High-efficiency Agricultural Heater and Smart Control System Utilizing Heat Pipe (히트파이프를 활용한 농업용 고효율난방기 및 스마트 제어시스템)

  • Kim, Eung-Kon;Lim, Chang-Gyoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1151-1158
    • /
    • 2017
  • The Effluent Heat Pipe integral with the heater is a device that recreates unused thermal energy from the plant in winter, and thus reuses unused energy before releasing the exhaust heat. Through the establishment of facility horticulture and glass greenhouses, we identified the problems of our agricultural heaters, and we proposed efficient agricultural efficiency and smart control systems for optimum agricultural efficiency and smart house.

Load Simulator with Power-Recovery Capability Based on Voltage Source Converter-Inverter Set (전력회수 능력을 갖는 전압원 컨버터-인버터 세트로 구성 된 부하모의 장치)

  • Bae Byung-Yeol;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.4
    • /
    • pp.181-187
    • /
    • 2005
  • This paper describes a load simulator with power-recovery capability, which is based on the voltage source converter-inverter set. The load simulator described in this paper can save the electric energy that should be consumed to test the operation and performance of the distributed generation system and the power quality compensator. The load simulator consists of a converter-inverter set with a DSP controller for system control and PWM pulse generation. The converter operates as a universal load to model the linear load and the non-linear load, while the inverter feed the energy back to the power source with harmonic compensation. The load simulator can be widely used in the lab to test the performance of the distributed generation system and the power quality compensator.

Turbine Design for Turbo-compound System to Recover Exhaust Gas Energy Using 1-D Mean Line Flow Model (1-D Mean Line Flow Model을 이용한 엔진 배기에너지 회수를 위한 터보컴파운드 시스템용 터빈 설계)

  • Jang, Jinyoung;Yun, Jeong-Eui
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.74-81
    • /
    • 2016
  • The aim of this study was to find the initial design value of turbine blade for electrical type turbocompound system generating 10 kW. Turbocompound is one of the waste heat recovery system applying to internal combustion engine to recover exhaust gas energy that was about 30 % of total input energy. To design the turbine blade, 1-D mean line flow model was used. Exhaust gas temperature, pressure, flow rate and turbine rotating speed was fixed as primary boundary conditions. The velocity triangles was defined and used to determine the rotor inlet radius and width, the rotor outlet radius at shroud and radius at hub, the rotor flow angles and the number of blades.

Separation of Surfactants by UF Membrane (UF막에 의한 계면활성제의 분리)

  • 안순철;송근호;이광래
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.137-139
    • /
    • 1998
  • 계면활성제는 섬유, 의약품, 화장품, 식품, 조선, 토목, 건축, 광업, 가정용 세제 등 인간생활에 폭넓게 이용되고 있다. 계면활성제의 사용범위가 넓어짐에 따라 계면활성제 자체의 오염성 때문에 분리대상 물질이나 재사용을 위한 회수물질로 간주되고 있다. 특정물질의 분리$\cdot$회수를 위한 분리막 기술은 공정이 간단하고 상변화를 수반하지 않으므로 에너지 소모가 작은 장점들을 가지고 있어 폐수처리, 수처리, 대기오염 방지등에 이용되고 있다. 본 연구에서는 비교적 소수기가 짧아서 저온에서도 잘 녹고, 세정성이 양호하여 세제, 유화제, 섬유제품의 침투제로 널리 이용되고 있는 음이온 계면활성제 SDS와 SLS용액의 한외여과에 대한 투과실험을 수행하였다. 또한 음이온 계면활성제와 인체에 유해한 금속이온($Cd^{++}, Cu^{++}, Zn^{++}$) 혼합물에 대한 제거실험을 실시하였다.

  • PDF

Feasibility study on waste heat utilization system in subway (지하철배열 이용 시스템의 경제성 평가)

  • Lee, Chul-Goo;Kim, Jong-Dae;Im, Tae-Soon;Pang, Seun-Gki;Ham, Heung-Don
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.59-64
    • /
    • 2011
  • Feasibility study on energy saving system by utilizing exhausted heat from subway, which is one of the unused energy, was carried out. General heat source system using absorption chiller-heater was used for comparing to the energy saving system, and payback period method using initial cost and running cost of two systems, was used to perform economic estimation. Payback period was about ten years, and this period might be shortened if nation's economic support enact.