• Title/Summary/Keyword: 에너지준위

Search Result 318, Processing Time 0.022 seconds

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

Structural properties and optical studies of two-dimensional electron gas in Al0.55Ga0.45/GaN heterostructures with low-temperature AlN interlayer (저온 성장 AlN 층이 삽입된 Al0.55Ga0.45N/AlN/GaN 이종접합 구조의 구조적 특성 및 이차원 전자가스의 광학적 특성)

  • Kwack, H.S.;Lee, K.S.;Kim, H.J.;Yoon, E.;Cho, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.34-39
    • /
    • 2008
  • We have investigated the characteristics of $Al_{0.55}Ga_{0.45}N$/GaN heterostructures with and without low-temperature (LT) AlN interlayer grown by metalorganic chemical vapor deposition. The structural and optical properties were systematically studied by Rutherford backscattering spectroscopy (RBS), X-ray diffraction (XRD), optical microscopy (OMS), scanning electron microscopy (SEM), and photoluminescence (PL). The Al content (x) of 55% and the structural properties of $Al_xGa_{1-x}N$/GaN heterostructures were investigated by using RBS and XRD, respectively. We carried out OMS and SEM experiments and obtained a decrease of the crack network in $Al_{0.55}Ga_{0.45}N$ layer with LT-AlN interlayer. A two-dimensional electron gas (2DEG)-related PL peak located at ${\sim}3.437eV$ was observed at 10 K for $Al_{0.55}Ga_{0.45}N$/GaN with LT-AlN interlayer. The 2DEG-related emission intensity gradually decreased with increasing temperature and disappeared at temperatures around 100 K. In addition, with increasing the excitation power above 3.0 mW, two 2DEG-related PL peaks were observed at ${\sim}3.411$ and ${\sim}3.437eV$. The observed lower-energy and higher-energy side 2DEG peaks were attributed to the transitions from the sub-band level and the Fermi energy level of 2DEG at the AlGaN/LT-AlN/GaN heterointerface, respectively.

Analysis of Mistakes in Photosynthesis Unit in Biology II Textbooks and Survey of Biology Teachers' Recognition on them (생물 II 교과서 광합성 단원의 오류 분석 및 생물 교사의 오류 인지 조사)

  • Park, Hae-Kyung;Yoon, Ki-Soon;Kwon, Duck-Kee
    • Journal of Science Education
    • /
    • v.32 no.1
    • /
    • pp.33-46
    • /
    • 2008
  • The purpose of this study was to know whether or not any wrongful description or simple errors were in photosynthesis unit of Biology II textbook under 7th national curriculum and if so, to know whether or not high school teachers recognized and corrected properly the mistakes. The mistakes in photosynthesis unit of text books were determined by the comparison with several reference books and through examination by three plant physiologists in 8 different Biology II textbooks. After the mistakes were analysed, the survey using contents of textbook containing the mistakes was conducted on high school teachers teaching Biology II. As a result, 48 mistakes were determined in 13 subjects. As many as four mistakes were found even in one subject in a certain textbook and a same mistake was found repeatedly in several textbooks. The survey result showed that the teachers who pointed exactly the mistakes out corrected properly, however, the percentage of these ones out of 35 teachers replied to survey was less than 50%. The ratios of correction out of total number of responses were high in question #6 (43%), #4-3 (40%), and #1-2 (32%) which were containing a simple mistake in graph, a wrong word and a wrong picture, respectively. But, no one pointed out and made correction in question #5-1 and #5-2 which were containing Z scheme of light reaction without the legend of vertical axis that should be explained as electron energy or standard reduction potential. The result indicates the possibility that the mistakes in photosynthesis unit of Biology II textbook can be corrected and teached properly by teachers may be low. In order to reduce the possibility that students may have misconceptions about photosynthesis, the list of print's errors should be provided to the teachers and/or the training program and/or workshop for in-service high school biology teachers was recommended.

  • PDF

Improvement of Cu2ZnSnS4 Solar Cell Characteristics with Zn(Ox,S1-x) Buffer Layer (Zn(Ox,S1-x) 버퍼층 적용을 통한 Cu2ZnSnS4 태양전지 특성 향상)

  • Yang, Kee-Jeong;Sim, Jun-Hyoung;Son, Dae-Ho;Lee, Sang-Ju;Kim, Young-Ill;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.93-98
    • /
    • 2017
  • This experiment investigated characteristic changes in a $Cu_2ZnSnS_4$(CZTS) solar cell by applying a $Zn(O_x,S_{1-x})$ butter layer with various compositions on the upper side of the absorber layer. Among the four single layers such as $Zn(O_{0.76},S_{0.24})$, $Zn(O_{0.56},S_{0.44})$, $Zn(O_{0.33},S_{0.67})$, and $Zn(O_{0.17},S_{0.83})$, the $Zn(O_{0.76},S_{0.24})$ buffer layer was applied to the device due to its bandgap structure for suppressing electron-hole recombination. In the application of the $Zn(O_{0.76},S_{0.24})$ buffer layer to the device, the buffer layer in the device showed the composition of $Zn(O_{0.7},S_{0.3})$ because S diffused into the buffer layer from the absorber layer. The $Zn(O_{0.7},S_{0.3})$ buffer layer, having a lower energy level ($E_V$) than a CdS buffer layer, improved the $J_{SC}$ and $V_{OC}$ characteristics of the CZTS solar cell because the $Zn(O_{0.7},S_{0.3})$ buffer layer effectively suppressed electron-hole recombination. A substitution of the CdS buffer layer by the $Zn(O_{0.7},S_{0.3})$ buffer layer improved the efficiency of the CZTS solar cell from 2.75% to 4.86%.

Comparison of the Mid-term Changes at the Remnant Distal Aorta after Aortic Arch Replacement or Ascending Aortic Replacement for Treating Type A Aortic Dissection (A형 급성대동맥박리증에서 대동맥궁치환술과 상행대동맥치환술 후 잔존 원위부 대동맥의 변화에 대한 중기 관찰 비교)

  • Cho, Kwang-Jo;Woo, Jong-Su;Bang, Jung-Hee;Choi, Pill-Jo
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.414-419
    • /
    • 2007
  • Background: Replacing the ascending aorta is a standard surgical option for treating acute type A aortic dissection. But replacing the aortic arch has recently been reported as an acceptable procedure for this disease. We compared the effects of aortic arch replacement for treating acute type A aortic dissection with the effects of ascending aortic replacement. Material and Method: From 2002 to 2006, 25 patients undewent surgical treatment for acute type A aortic dissection, 12 patients undewent ascending aortic replacement and 13 patients underwent aortic arch replacement. Among the aortic arch group, an additional distal stent-graft was inserted during the operation in 5 patients. 19 patients (11 arch replaced patients and 8 ascending aortic replaced patients) were followed up at the out patient clinic for an average of $756{\pm}373$ days. All the patients undewent CT scanning and we analyzed their distal aortic segments. Result: 4 patients who underwent ascending aortic replacement died, so the overall mortality rate was 16%. Among the 11 long term followed-up arch replacement patients, 2 patients (18.1 %) developed distal aortic dilatation and one of them underwent thoracoabdominal aortic replacement later on. However, among the 8 the ascending aortic replaced patients, 5 patients (62.5%) developed distal aortic dilatation. Conclusion: Aortic arch replacement is one of the safe options for treating acute type A aortic dissection. Aortic arch replacement for treating acute type A aortic dissection could contribute to a reduced distal aortic dilatation rate and fewer secondary aortic procedures.

Surgical Results for Treating Postpneumonectomy Empyema with BPF by Using an Omental Pedicled Flap and Thoracoplasty (전폐절제술 후 기관지 흉막루를 동반한 농흉에서 유경성 대망 이식편과 흉곽성형술을 이용한 수술적 치료에 대한 임상 고찰)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.420-427
    • /
    • 2007
  • Background: Postpneumonectomy empyema (PPE) due to bronchopleural fistula (BPF) can be a surgical challenge for surgeons. We analyzed the follow-up outcomes after performing omentopexy and thoracoplasty for the treatment of PPE with BPF after pneumonectomy. Material and Mehod: Between December 1991 and January 2006, 9 patients underwent BPF closure using an omental pedicled flap for the treatment of PPE with BPF after pneumonectomy. There were 7 males and 2 females (mean age: $45.9{\pm}9$ years). The patients were followed up for a mean of 58 months (median: 28 months, range: $6{\sim}169$). When we performed omentopexy, the surgical procedures for empyema were thoracoplasy for 8 patients and the Clagett procedure for 1 patient. Thoracoplasty was performed for the latter patient due to recurrence of empyema, Result: For the 8 patients who were treated by omentopexy and thoracoplasty, there was 1 operation-related death due to sepsis. During follow up, 1 patient, who was treated by omentopexy and a Clagett procedure, died of acute hepatitis 40 months postoperatively. The early mortality was 11.1% (8/9). Of the 8 patients, including the 1 late death patient, successful closure of the BPF were achieved in all patients (8/9) and the empyema was cured in 7 patients (7/8). Conclusion: The BPF closure using an omental pedicled flap was an effective method for treating PPE with BPF due to 75-destroyed lung, and thoracoplasty with simultaneous omentopexy was effective and safe for removing dead space if the patient was young and in a good general condition.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.