• Title/Summary/Keyword: 에너지이용합리화

Search Result 64, Processing Time 0.024 seconds

A Programme to Build and to Drive the Regional Energy Planning System(REPS) (지역에너지계획제도 구축 및 추진 방안)

  • Lee, Jang-Woo;Hong, Yang;Hahm, Hyo-Joon;Lee, Chang-Ki
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.11a
    • /
    • pp.64-68
    • /
    • 1993
  • This paper represents a programme to build and to drive the Regional Energy Planning System(REPS), which projects the expansion of energy supply and the requirement of energy accompany with the reducing of energy consumption by the energy conservation technologies and the considering of environment by the clean energy technologies in the region of each consumer works at. Therefore, in this paper, defined the REPS, presented the main items and contents should be involved in it, and discussed the way to build and to drive it.

  • PDF

A Note on Direct Contact Exchangers (직접방식 열교환기와 전달특성)

  • 김석현
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.829-835
    • /
    • 1995
  • 통상의 열교환기에서 전열면이 제거된 형태의 직접열교환을 통하여 제작비나 열전달 특성에 큰 효과를 얻을 수도 있어 에너지이용 합리화에 기여하는 특성과 사례를 언급하였다. 또한 통상의 열교환기 설계와 다른 매질간의 공유계면에서 발생 가능한 전달특성을 위주로 설계상의 일부 유의사항을 기술하였다. 직접열교환의 기술축적은 상변화를 동반하는 열전달(two phase heat transfer) 문제의 기초지식은 물론, 염수플랜트(desalination)의 기본 요소설계, 원자로의 냉각계 통사고(LOCD)대책, 기타 냉각탑, 탱크가열, 증발기(evaporator), 건조장치(drier), 각종 기계, 화공 공정장치 설계 등 매우 광범위한 기술파급 효과도 기대할 수 있으므로 관련 기술자들의 많은 관심을 기대한다.

  • PDF

The research in rationalization of the use of energy in electric power (에너지 이용 합리화를 위한 전기에너지 사용계획 수립에 관한 연구)

  • Kim, Man-Kook;Nam, Si-Bok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.392-399
    • /
    • 2009
  • This study investigates and analyzed electrical energy curtailment effect by each business department and by energy use efficiency elevation equipment because do an energy use plan that is enforced in each variety business that is developed in domestic by model. When plan the recent electrical energy use with this, I wish to contribute in energy use general planning establishment improvement that is aiming energy efficiency improvement newly by groping improvement plan moment deduce problem. Specially, search present condition and problem by electrical energy curtailment equipment application that probes mass and analyzed, and is applied in present our country according to analysis contents to the latest energy use plan that was enforced on energy use rationality narration but allowed purpose.

  • PDF

Building Energy Management System with Next Day Demand Forecasting of Building Load (익일 빌딩 부하 예측 기능을 갖는 빌딩에너지관리시스템)

  • Choi, Sang-Yule
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.119-123
    • /
    • 2014
  • The main purpose of reactive power compensation monitoring system is to manage factory electrical installation efficiently by On-Off switching reactive power compensation equipment. The existing reactive power compensation monitoring system is only able to be managed by operator whenever electrical installation needed reactive power. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a reactive power compensation monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.

Development of Hybrid Fuel Cell UPS System (하이브리드 연료전지 UPS 시스템 개발)

  • Hyun, Deok-Su;Jang, Min-Ho;Kim, Tae-Sin;Oh, Se-Woong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.235-235
    • /
    • 2009
  • 본 연구는 친환경 신새생 에너지를 이용한 전력 시스템을 개발함으로써 전력 IT인 Smart Grid 기술 활용과 더불어 예기치 못한 정전으로부터 중요한 전자 장비를 보호하는 UPS 기능을 갖는 친환경 3.0kW급 하이브리드 연료전지 UPS 시스템을 개발하는 것이다. 이를 위하여 시뮬레이션 기법을 이용하여 소형 경량화에 따른 구성 부품 배치 합리화 및 발생열 최적화 설계를 도출하였으며, 연료전지용 장수명 밀폐형 Ni-MH전지, 고효율 전력변환기, 하이브리드 PMS의 설계 및 제작과 개발된 3kW급 하이브리드 연료전지 UPS 시스템 기능 및 성능 평가를 공인 기관에서 검증받았다. 본 연구를 통하여 개발된 연료전지용 장수명 100Ah급 밀폐형 Ni-MH전지는 밀폐화와 더불어 장수명화 및 저온 방전 특성이 우수한 뿐만 아니라 KS규격을 모두 만족하였으며, 내구성도 DOD100%에서 1,093cycle의 결과를 얻을 수 있었다. 또한, 전지 설계 및 제작 기술뿐만 아니라 양산화 관련 기술들이 개발되어 향후 고용량, 고출력, 장수명의 축전지가 필요로 하는 분야에 적용될 수 있는 기반이 마련되었다. 또한 고효율 전력 변환기 및 연료전지과 축전지를 조절하는 PMS을 탑재한 소형 경량화 된 친환경 IT제품의 이미지를 구현하였다.

  • PDF

Voluntary Agreements on Energy Conservation and Emission Reduction -Economic Analysis Using a Dynamic CGE Model- (자발적 협약의 에너지 절감과 온실가스 감축효과 -동태적 연산일반균형모형을 이용한 경제적 분석-)

  • Jo, Sunghan;Lim, Jaekyu
    • Environmental and Resource Economics Review
    • /
    • v.15 no.1
    • /
    • pp.95-133
    • /
    • 2006
  • This research first reviewed and analysed the current domestic situation of the voluntary agreement implementation and then it developed the policy implementation scenarios which will be applied to the model, KORTEM_ V.2. The model, consisted with 83 industries and commodities, examined the economic and environmental impacts of this policy instrument. Depending on the efforts of participating sectors and agents for fuel substitution and energy efficiency improvement, it has been evaluated that the voluntary agreement could be the "no-regret" policy. In other words, if the participating sectors and agents can achieve the voluntary energy conservation and emission reduction target without the negative impact on output level, the reduction of national emission will be achieved by creating the economic benefit, simultaneously. Therefore, for the successful implementation of voluntary agreement, this study emphasized the importance of expansion and strengthening of the current financial and institutional support for participating sectors and agents.

  • PDF

Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment (지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.571-579
    • /
    • 2014
  • A series of field tests on hybrid desiccant cooling systems were conducted in July-August, 2013. The temperature and humidity of the supply and return air, power, and heat consumption were monitored and transferred in real time through the Internet. The performance parameters of the cooling system, namely, cooling capacity and COP (coefficient of performance), were evaluated from the measured data and their variations under outdoor conditions was analyzed. It was found that with increase in the outdoor temperature, the total energy decreases and cooling capacity increases whereas the latter decreases with increase in the outdoor humidity. The COP was also found to increase with the increase in outdoor temperature.

Thermal Performance of PV Cells Exposed to Irradiation by a Parabolic Trough Concentrator (PTC형 태양열 집열기로 조사되는 PV cell의 열적 성능)

  • Hwang, Seon Yeob;Kang, Tae Gon;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 연구에서는 PV cell이 직달 일사에 노출되는 경우와 집광된 태양광에 조사되는 경우의 성능을 비교하는 한편 집광기의 형태에 따른 열적 성능을 검토하고자 하였다. PV cell은 본질적으로 반도체의 특성을 가지므로 작동온도의 상승에 따라 성능이 저하된다는 사실이 알려져 있으며, 태양조사의 강도 및 밀도 등 특성에 따라서도 성능의 변화를 예상할 수 있다. 그러나 이러한 성능변화에 관련된 인자들과 그 영향의 크기에 대한 정량적인 기술자료가 부족하므로 설치와 이용에 한계가 있는 것이 현실이다. 인공태양 장치(solar simulator)를 이용하여 0.7에서 1.2 sun 범위의 태양 조사 환경에서 결정질 실리콘계 PV cell과 집광형 PV cell의 성능을 검토하였다. 집광에 사용한 PTC는 집광면적의 폭이 500 mm이며, 집광 조사면적이 최소 10 mm인 경우 이론적 최대 집광비가 50이었다. PTC의 축방향으로는 균일한 태양조사가 있게된다는 것을 가정하여 모델의 길이는 간편한 실험을 위해 150에서 500 mm의 범위에서 제작하였다. 수평으로 놓인 PTC의 상부 초점 위치로부터 집광면이 아래 쪽에 위치할수록 집광 조사 면적이 증가하므로 PV cell의 크기에 따라 PTC 초점의 위치로부터 거리를 결정하였다. 한편, PTC 자체의 성능도 촛점거리와 집광면 폭의 비에 따라 달라질 수 있다는 가정 하에, 포물면의 최저 위치로부터 촛점거리는 각각 300, 400 및 500 mm가 되도록 세가지 형태를 제작하여 사용하였다. 동일한 형태의 PTC에서 PV cell의 동일한 설치 위치에서도 최고 $110^{\circ}C$ 범위의 PV cell의 작동 (표면) 온도에 따른 성능의 차이를 관찰하기 위해 셀의 후면을 냉각시키는 경우와 그렇지 않은 경우를 비교하였다. PV cell의 표면 온도 측정을 위해서, 후면의 온도와 같이 광선 차단 효과의 우려가 없는 경우에는 열전대를 설치하였으며, 셀의 전면 온도 측정을 위해서는 비접촉식 적외선 온도계를 사용하였다. 냉각 방법으로는 공기를 이용한 자연대류와 액체를 사용하는 강제대류의 경우를 고려하였으며, 필요에 따라 적절히 설계된 히트싱크를 설치하여 비교 실험을 진행하였다. 강제대류 냉각의 경우는 항온조를 사용하여 순환하는 냉각수의 유량과 공급온도를 변화시킴으로써 PV cell의 작동온도를 조절하고, 이에 따른 발전 성능의 변화를 관찰하였다. 본 연구에서 도출한 실험 및 분석 결과는 PV cell의 설치 환경과 작동온도의 변화에 따라 그 성능 변화를 예측할 수 있는 기술적 자료를 제공함으로써 에너지 이용의 합리화를 도모하는데 기여할 수 있을 것이다.

  • PDF

Development of a stand-alone solar street light controller integrated (독립형 태양광 가로등 통합제어기 개발)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.6
    • /
    • pp.641-647
    • /
    • 2014
  • Stand-alone PV systems and grid-connected distribution lines operating independently with out the advantage that it is simple, and construction equipment, but the advantage of less expensive MPPT converter and production, including the energy stored in the battery charging circuit and battery for managing circuitry is required. The use of existing alternative energy in the form of combined-cycle power generation than the one adopted by the form, but primarily solar / wind power system to optimize complex to design and improve the ability to install a battery that canrationalize the price you need an integrated control system be.

A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency (비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구)

  • Jang, Hyun-Sook;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.3-12
    • /
    • 2012
  • The slowdown of private building industry resulted in growth of remodeling market as a way to improve energy performance. Remodeling is considered more cost-effective and eco-friendly approach for energy efficient building than new construction. Since 2008, Seoul has promoted Building Retrofit Project (BRP) preponderantly to attract energy-saving renovation by supporting building owners to switch building system into energy-saving system when they remodel their old buildings. According to 2012 press release, 254 Private sectors participated in this green building project and annually reduced 41000ton of greenhouse gas emission, 14000TOE, which also result in 7.5 billion won energy cost savings per year. The paper focuses on the building envelope remodeling as a way to improve energy efficiency. Different components of the building envelope such as wall insulation, window, and shading, were applied to the baseline model and the comparison was analyzed to come up with the ideal solution. This study only assesses the building envelope as to suggest the way to redesign the better energy performing building. Offering solution focusing on the architectural feature is essential because it will provide basic information and standard when remodeling a building for energy efficiency, especially, for the nonresidential buildings used as rental offices.