• Title/Summary/Keyword: 에너지예측

Search Result 2,628, Processing Time 0.028 seconds

Analytical Study on the Prying Action Force and Axial Tensile Stiffness of High-Strength Bolts Used in an Unstiffened Extended End-Plate Connection (비보강 확장단부판 접합부에 체결된 고장력볼트의 지레작용력 및 축방향 인장강성에 대한 해석적 연구)

  • Kim, Hee Dong;Yang, Jae Guen;Lee, Hyung Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.251-260
    • /
    • 2015
  • The end plate connection is applied to beam-column moment connections in various forms. Such end plate connection displays changes in the behavioral characteristics, strength and stiffness, and energy dissipation capacity based on the thickness and length of the end plate, the number and diameter of the high strength bolt, the gauge distance of the high strength bolt, prying action force of the high strength bolt, and dimensions and length of the welds. Accordingly, this study has apprehended the axial tensile stiffness and prying action force of the high strength bolt connected on the tensile side based on the difference in thickness of the end plate, and was conducted to propose an analysis model for the prediction of such variables that affect the operating properties of the end plate. To achieve this, this study has conducted a three-dimensional non-linear finite-element analysis of the unstiffened expanding end plate connection by selecting only the thickness of the end plate as the variable.

Data Statical Analysis based Data Filtering Scheme for Monitoring System on Wireless Sensor Network (무선 센서 네트워크 모니터링 시스템을 위한 데이터 통계 분석 기반 데이터 필터링 기법)

  • Lee, Hyun-Jo;Choi, Young-Ho;Chang, Jae-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.53-63
    • /
    • 2010
  • Recently, various monitoring systems are implemented actively by using wireless sensor networks(WSN). When implementing WSN-based monitoring system, there are three important issues to consider. At First, we need to consider a sensor node failure detection method to support the ongoing monitoring. Secondly, because sensor nodes use limited battery power, we need an efficient data filtering method to reduce energy consumption. At Last, a reducing processing overhead method is necessary. The existing Kalman filtering scheme has good performance on data filtering, but it causes too much processing overhead to estimate sensed data. To solve these problems, we, in this paper, propose a new data filtering scheme based on data statical analysis. First, the proposed scheme periodically aggregates node survival massages to support a node failure detection. Secondly, to reduce energy consumption, it sends the sample data with a node survival massage and do data filtering based on those messages. Finally, it analyzes the sample data to estimate filtering range in a server. As a result, each sensor node can use only simple compare operation for filtering data. In addition, we show from our performance analysis that the proposed scheme outperforms the Kalman filtering scheme in terms of the number of sending messages.

Development of Water Hammer Simulation Model for Safety Assessment of Hydroelectric Power Plant (수력발전설비의 안전도 평가를 위한 수충격 해석 모형 개발)

  • Nam, Myeong Jun;Lee, Jae-Young;Jung, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.760-767
    • /
    • 2020
  • Sustainable growth of hydroelectric power plants is expected in consideration of climate change and energy security. However, hydroelectric power plants always have a risk of water hammer damage, and safety assurance is very important. The water hammer phenomenon commonly occurs during operations such as rapid opening and closing of the valves and pump/turbine shutdown in pipe systems, which is more common in cases of emergency shutdown. In this study, a computational numerical model was developed using the MOC-FDM scheme to reflect the mechanism of water hammer occurrence. The proposed model was implemented in boundary conditions such as reservoir, pipeline, valve, and pump/turbine conditions and then applied to simulate hypothetical case studies. The analysis results of the model were verified using the analysis results at the main points of the pipe systems. The model produced reasonably good performance and was validated by comparison with the results of the SIMSEN package model. The model could be used as an efficient tool for the safety assessment of hydroelectric power plants based on accurate prediction of transient behavior in the operation of hydropower facilities.

Professional Nursing Quality Assurance (전문직 간호의 질적보장)

  • Kim, Hea-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.22 no.2
    • /
    • pp.248-259
    • /
    • 1992
  • 질적 보장은 전문직 종사자에 의하여 수혜받는 대상자를 보호하기 위하여 전적으로 필요한 프로그램이다. 이러한 질적보장을 통하여 전문직의 자율성과 책임을 튼튼히 할 수 있는 의무는 전문직 종사자 모두의 관심사가 되어야 한다. 미국에 있어서 질적 간호에 대한 관심은 이제 새로운 이유가 아니다. Beyers(1988)는 건강체계 지도자 사이에 가장 중요한 문제로 강조하는 것이 수혜자의 이용의 용이성(Access), 숫가(Cost) 그리고 질적인 제공(Quality)이 라고 피력 하였다. 미국 건강사업 평가자와 조정자(Regulator)들은 질(Quality)을 위한 자율적인 프로그램에 많은 에너지를 투입하여 전반적인 건강사업 즉 의료계의 질보장, 더 나아가서는 간호의 질을 향상 시키기 위한 많은 프로그램을 분석 연구한다. 이 논문은 간호에 있어서 질적 보장을 위한 내용으로 주요점은 질적 보장에 사용되는 용어, 역사적 배경, 질적 보장을 강조하는 이유, 질적 보장제도의 개발, 질 사정(euali assessment)과 질적 보장에 있어서 간호 전문직 개입을 차례대로 설명하였다. 구미의 경우 1970년대부터 간호직에 있어서는 질적보장제도개발에 우선순위를 두게되어 미 간호협회에서는 Professional Standards Review Organizations (PSRO)에 근거하여 간호실무를 위한 표준을 내어놓았다. 질적보장을 위한 평가방법으로 구조, 과정, 결과 그리고 수혜자가 간호계획을 세우는데 사정에 참여하는 방법 등 4가지를 간략하게 설명하였다. 질적 보장을 향상시키기 위해서는 전문직과 공공의료기간이 서로 협동체가 되어 중추역할을 해야함을 강조하고 이렇게 서로 협력하므로써만이 비로서 우리의 목적을 성취할 수 있다고 생각된다.구 등이 이용된다. $^{166}$ Ho, $^{198}$ Au, $^{32}$P, $^{90}$ Y, $^{169}$ Er, $^{186}$ Rc, $^{131}$ I, $^{211}$ At 등 의 방사성 핵종의 교질, 미소구 또는 단세포군 항체표지 형태로 직접 종양내 또는 공동이나 체강에 투여하는 치료법이 있다. 류마치스 관절염의 슬관절에 $^{165}$ Dy colloid를 주사하는 $^{166}$ Ho-MAA도 활발히 이용되고 있다. and computed groundwater levels. 본 논문에서는 가파른 산사면에서 산사태의 발생을 예측하기 위한 수문학적 인 지하수 흐름 모델을 개발하였다. 이 모델은 물리적인 개념에 기본하였으며, Lumped-parameter를 이용하였다. 개발된 지하수 흐름 모델은 두 모델을 조합하여 구성되어 있으며, 비포화대 흐름을 위해서는 수정된 abcd 모델을, 포화대 흐름에 대해서는 시간 지체 효과를 고려할 수 있는 선형 저수지 모델을 이용하였다. 지하수 흐름 모델은 토층의 두께, 산사면의 경사각, 포화투수계수, 잠재 증발산 량과 같은 불확실한 상수들과 a, b, c, 그리고 K와 같은 자유모델변수들을 가진다. 자유모델변수들은 유입-유출 자료들로부터 평가할 수 있으며, 이를 위해서 본 논문에서는 Gauss-Newton 방법을 이용한 Bard 알고리즘을 사용하였다. 서울 구로구 시흥동 산사태 발생 지역의 산사면에 대하여 개발된 모델을 적용하여 예제 해석을 수행함으로써, 지하수 흐름 모델이 산사태 발생

  • PDF

Molecular Separation of Dibromobenzene Isomers by using Selective Guest Inclusion of G2NDS Host Framework (G2NDS 호스트의 선택적 내포 현상을 이용한 Dibromobenzene 이성질체의 분자분리)

  • Kim, Jinsoo;Park, Jimin;Yi, Jongheop;Kim, Woo-Sik
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.487-492
    • /
    • 2007
  • Using the selective host-guest inclusion of $G_2$[naphthalene disulfonate], the structural isomers of 1,2-dibromobenzene and 1,3-dibromobenzene were separated. As such, 1,3-dibromobenzene was selectively included as guest into the host framework in mixture isomers over 30% fraction of 1,3- dibromobenzene ($X_{1,3-DBB}=0.3$) whereas 1,2-dibromobenzene as guest was selective to the inclusion below $X_{1,3-DBB}=0.3$. This was due to the selectivity of host framework toward the guest molecules playing a role of template to the host framework. From the powder pattern XRD of inclusion compounds crystallized in pure isomer and mixture solutions, the template roles of guest molecules to the host framework were confirmed. Using the DSC, it was found that the more energy was required to release 1,3-dibromobenzene of guest from the host framework than 1,2-dibromobenzene due to the higher thermal stability. The thermal stability of the $G_2NDS$-1,3-dibromobenzene inclusion compound was consistent with the high selectivity of 1,3- dibromobenzene to the host framework in broad range of fraction in the isomer mixture

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

Numerical Analysis on the Determination of Head Loss by Perforated Vertical Walls (연직 유공벽의 수두손실 결정을 위한 수치해석)

  • Chun, In-Sik;Lee, Seong-Yeop;Park, Kyung-Soo;An, Dong-Keun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.3
    • /
    • pp.194-204
    • /
    • 2007
  • A numerical analysis and hydraulic experiments were undertaken to investigate the head loss occurring when a flow passes through vertical perforated walls. The numerical analysis applied continuity, momentum and energy equations to the control volumes that were set near the perforated wall. Non-dimensional equations were then derived to calculate both upstream depth and head loss for the given values of downstream depth and velocity. The hydraulic experiments were performed with several single and triple perforated plates varying their opening ratios and intervals. The numerical results with the single plates were compared with the experimental results, and it was shown that the contraction coefficient of the vertical line jet formed after the perforated plates relies on downstream Froude number as well as opening ratio. Based on the experimental results, empirical formulas were formulated. Finally, the formulas were applied to the triple plates sequentially from downstream side to upstream side, and it was found that in general the predicted values nicely agreed with the experimental results.

Particle Based Discrete Element Modeling of Hydraulic Stimulation of Geothermal Reservoirs, Induced Seismicity and Fault Zone Deformation (수리자극에 의한 지열저류층에서의 유도지진과 단층대의 변형에 관한 입자기반 개별요소법 모델링 연구)

  • Yoon, Jeoung Seok;Hakimhashemi, Amir;Zang, Arno;Zimmermann, Gunter
    • Tunnel and Underground Space
    • /
    • v.23 no.6
    • /
    • pp.493-505
    • /
    • 2013
  • This numerical study investigates seismicity and fault slip induced by fluid injection in deep geothermal reservoir with pre-existing fractures and fault. Particle Flow Code 2D is used with additionally implemented hydro-mechanical coupled fluid flow algorithm and acoustic emission moment tensor inversion algorithm. The output of the model includes spatio-temporal evolution of induced seismicity (hypocenter locations and magnitudes) and fault deformation (failure and slip) in relation to fluid pressure distribution. The model is applied to a case of fluid injection with constant rates changing in three steps using different fluid characters, i.e. the viscosity, and different injection locations. In fractured reservoir, spatio-temporal distribution of the induced seismicity differs significantly depending on the viscosity of the fracturing fluid. In a fractured reservoir, injection of low viscosity fluid results in larger volume of induced seismicity cloud as the fluid can migrate easily to the reservoir and cause large number and magnitude of induced seismicity in the post-shut-in period. In a faulted reservoir, fault deformation (co-seismic failure and aseismic slip) can occur by a small perturbation of fracturing fluid (<0.1 MPa) can be induced when the injection location is set close to the fault. The presented numerical model technique can practically be used in geothermal industry to predict the induced seismicity pattern and magnitude distribution resulting from hydraulic stimulation of geothermal reservoirs prior to actual injection operation.

Evaluation of Interlayer Shear Properties and Bonding Strengths of a Stress-Absorbing Membrane Interlayer and Development of a Predictive Model for Fracture Energy (덧씌우기 응력흡수층에 대한 전단, 부착강도 평가 및 파괴에너지 예측모델 개발)

  • Kim, Dowan;Mun, Sungho;Kwon, Ohsun;Moon, Kihoon
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.87-95
    • /
    • 2018
  • PURPOSES : A geo-grid pavement, e.g., a stress-absorbing membrane interlayer (SAMI), can be applied to an asphalt-overlay method on the existing surface-pavement layer for pavement maintenance related to reflection cracking. Reflection cracking can occur when a crack in the existing surface layer influences the overlay pavement. It can reduce the pavement life cycle and adversely affect traffic safety. Moreover, a failed overlay can reduce the economic value. In this regard, the objective of this study is to evaluate the bonding properties between the rigid pavement and a SAMI by using the direct shear test and the pull-off test. The predicted fractural energy functions with the shear stress were determined from a numerical analysis of the moving average method and the polynomial regression method. METHODS : In this research, the shear and pull-off tests were performed to evaluate the properties of mixtures constructed using no interlayer, a tack-coat, and SAMI with fabric and without fabric. The lower mixture parts (describing the existing pavement) were mixed using the 25-40-8 joint cement-concrete standard. The overlay layer was constructed especially using polymer-modified stone mastic asphalt (SMA) pavement. It was composed of an SMA aggregate gradation and applied as the modified agent. The sixth polynomial regression equation and the general moving average method were utilized to estimate the interlayer shear strength. These numerical analysis methods were also used to determine the predictive models for estimating the fracture energy. RESULTS : From the direct shear test and the pull-off test results, the mixture bonded using the tack-coat (applied as the interlayer between the overlay layer and the jointed cement concrete) had the strongest shear resistance and bonding strength. In contrast, the SAMI pavement without fiber has a strong need for fractural energy at failure. CONCLUSIONS : The effects of site-reflection cracking can be determined using the same tests on cored specimens. Further, an empirical-mechanical finite-element method (FEM) must be done to understand the appropriate SAMI application. In this regard, the FEM application analy pavement-design analysis using thesis and bonding property tests using cored specimens from public roads will be conducted in further research.

Development of a Sustainable First Flush Management System for Urban Stream Water Quality Management (도시 하천 수질 관리를 위한 지속가능 초기 강우 오염 관리 시스템의 개발)

  • Seo, Dongil;Lee, Tongeun;Kim, Jaeyoung;Koo, Youngmin
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.247-255
    • /
    • 2016
  • Non-point pollutants from surface runoff during rainfall exert adverse effects on urban river water quality management. In particular, the first flush effect during the initial phase of rainfall can deliver significant amounts of pollutant loads to surface waters with extremely high concentrations. In this study, a sustainable first flush effect management system was developed by using settling and filtration that require no additional power or chemicals. A pilot scale experiment has shown that the removal of total suspended solid (TSS), total nitrogen (TN) and total phosphorus (TP) are in ranges of 84 - 95%, 31 - 46%, and 42 - 86%, respectively. An Integrated Stormwater Runoff Management System (ISTORMS) was also developed to efficiently manage the developed system by linking weather forecast, flow rate and water quality modeling of surface runoff and automatic monitoring systems in fields and in the system. This study can provide effective solutions for the management of urban river in terms of both quantity and quality.