• Title/Summary/Keyword: 양안

Search Result 387, Processing Time 0.024 seconds

Accommodative response measurement using both eyes open-view autorefractometer (양안 개방형 자동굴절검사기를 이용한 조절반응량 검사)

  • Shim, Hyun-Seog;Lee, Seong-Wook;Shim, Moon-Sik;Choi, Sun-Mi;Jang, Seong-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.323-328
    • /
    • 2005
  • The purpose of this research was to measurement real Accommodative response amount using both eyes open-view autorefractometer. Compared each Accommodative response amount to distinction of sex, age, kind of ametropia, amount of astigmatism and kind of astigmatism. The subjects were 153 healthy men and women between the age of 20~80 years. Age comparison, 20 years 1.15D, 30 years 1.23D and above 40 years 0.60D. It was no difference between 20 to 30 years old. But, is decrescent remarkably above 40 years old. Ametropia examined by hypermetropia 1.78D, emmetropia 1.51D, low myopia 1.08D, middle myopia 0.72D, high myopia 0.643D. Myopia increased, Accommodative response amount was expose that decrease. Astigmatism examined by non astigmatism 1.13D, low astigmatism 1.12D, middle astigmatism 0.85D, high astigmatism 0.83D. Astigmatism increased, Accommodative response amount was expose that decrease. The sex and astigmatism type difference appeared with the fact that the result is not a difference.

  • PDF

Stereoscopic Depth from 3D Contents with Various Disparity (화면 시차로부터 지각되는 3D 컨텐츠의 입체시 깊이)

  • Kham, Keetaek
    • Journal of Broadcast Engineering
    • /
    • v.21 no.1
    • /
    • pp.76-86
    • /
    • 2016
  • This study was investigated whether the perceived depth was changed depending on the measurement methods. In the method of direct comparison, virtual object with one of the various binocular disparities was presented in the frontal space with LEDs which were used for depth estimation for a binocular stimulus, while in the method of indirect comparison, visual object was presented in the frontal space but the LEDs were placed rightward at the angle of 45 degree from the mid-sagittal line. In these experimental setup, the depth of binocular stimulus was directly matched that of LED in direct comparison condition. In indirect comparison condition, however, observer estimated the depth of binocular stimulus, turned one's head rightward to the array of LEDs and turned on the LED which was supposed to be the same depth as binocular stimulus. Additionally, it was investigated whether the perceived depth was different depending on observer's stereo acuity. The results showed that perceived depths measured in the direct comparison were more similar to the depth predicted from geometry than those in the indirect comparison, and that the perceived depths from observers with high stereo acuity were similar to the predicted depth from geometry those from observers with low stereo acuity. These results indicated that stereoscopic depths of the binocular stimuli would vivid and compelling when binocular stimuli was simultaneously presented with real objects in the same visual space, like a mixed reality.

The effect of inter-pupillary distance on stereopsis (동공간 거리가 입체시 지각에 미치는 영향)

  • 감기택;이주환
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2003
  • Most 3D display systems heavily depend on binocular disparity to produce 3-dimensional depth of a scene. In principle, the vergence angle of the object on fixation and binocular disparity of non-fixated objects vary with the inter-pupillary distance(IPD) of the observer. However, most stereo systems provide the identical stereo image pairs regardless of the observers' IPD, which may result in variation in the perceived depth. In this study, we manipulated the vergence angle of the fixated object and binocular disparity of the non-fixated object. The range of the individual difference in the perceived depth was found to be increased with the increase of disparity for both the fixated and non-fixated objects, and the individual difference was well fitted by the regression line of the observers' IPD. These results suggest that individual difference in the perceived depth from the identical stereo images should be greatly reduced if the stereo system calibrates the disparity of the object by the observers' IPD in generating the stereo images and the regression line found in this study might be useful in the calibrating the disparity of the images.

  • PDF

Near Visual Performance of Multifocal Contact Lenses in University Students (대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성)

  • Jong, Woo-Cheol;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: This study was to investigate visual performance and subjective satisfaction with multifocal soft contact lenses at near works in university students. Methods: In a cross-over study design, 26 students (6 male, 20 female) who did not have any ocular disorder with at least 20/20(1.0) binocular vision were fitted with singlevision lenses (SofLens$^{TM}59$, Bausch + Lomb Co. USA) or multifocal lenses (SofLens Multifocal, Bausch + Lomb Co. USA). After 2 weeks, visual performance assessments included visual acuity, stereoacuity and contrast sensitivity function at distance and near. Near point of accommodation, accommodative facility, near point of convergence, vergence facility and near range of clear vision at near were examined. Students' satisfaction and preference were measured using survey questionaries. Results: Subjects maintained at least 20/20 binocular vision with multifocal and single-vision lenses at distance and near. There was no difference between multifocal and single-vision lenses in stereoacuity, contrast sensitivity function and vergence facility at far and near. The near point of accommodation, accommodative facility, near point of convergence and the near range of clear vision with multifocal lenses were better than single-vision lenses. On the survey questionaries, subjects reported that they preferred and satisfied with multifocal lenses with near works, and single-vision lenses with distance works. Conclusions: The majority of university students preferred multifocal to single vision lenses because multifocal lenses provided better visual performance at near works. This study suggests that multifocal lens is helpful for young adult in prolonged near works.

A Study on the Active Force of Extraocular Muscles (외안근의 운동력에 관한 연구)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.117-122
    • /
    • 2010
  • Purpose: The purpose of this study was to measure the active force of extraocular muscles on mono- and binocular movements for 62 healthy koreans (male: 29, female: 33). Methods: The force of adduction, abduction, elevation and depression, of right and left eye on monocular movement were tested with horizontal moving distance based on corneal limbus and the force of superior oblique muscle and inferior oblique muscle on binocular movement were measured with vertical moving distance between corneal limbus. The distances were obtained by high resolution digital image processing. Results: At monocular movements of tested subjects. the power of abduction, adduction, elevation and depression of right and left eye were (male) 9.35 nun, 9.75 mm, (female) 9.02 mm, 9.52 mm, (male) 10.23 mm, 10.16 mm, (female) 10.17 mm, 10.07 mm, (male) 7.01 mm,6.91 mm, (female) 6.98 mm, 6.64 mm, (male) 7.52 mm, 6.82 mm, (female) 7.52 mm, 6.67 mm, respectively. The active force of binocular movements were 54.8% hyperergasia and 45.1% hypergasia/67.7% hyperergasia and 32.2% hypergasia with inferior oblique muscle, 64.5% hyperergasia and 35.5% hypergasia/58.1% hyperergasia and 41.9% hypergasia with superior oblique muscle, respectively. Conclusions: The force of horizontal movement was higher than vertical movement. The value of adduction was higher than abduction on horizontal movement, and the value of depression was higher than elevation on vertical movement. In the both of inferior and superior oblique muscle, the ratio of hyperergasia was higher than that of hypergasia.

The Comparative Research of Dominant Eye and Non-dominant Eye by Ages (연령대별 우세안과 비우세안의 비교 연구)

  • Lee, Wan-Seok;Ye, Ki-Hun;An, Sun-Joung;Shin, Bum-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.203-211
    • /
    • 2013
  • Purpose: When we look at the object, we used the dominant eye mainly. For this reason, a prescription of the dominant eye is an important factor for glasses and contact lenses. This study evaluated visual acuity differences between dominant and nondominant eyes through analyzing refractive power changes in both eyes by the ages. Methods: This study was performed to investigate the relationship between refractive error and dominant eye which had the superiority in the function of binocular. 186 subjects without ocular disease were examined on the dominant eye. The dominant eye was examined by the Hole-in-the-card test. For the consistency of the measurements, we tested refractive power in three times by the same person. Results: Using SPSS, the relationship between vision and the dominant eye was analyzed. 135 people of the whole subjects have the dominant eye on right. The Number of the non-dominant eye is 51. We were divided into 3 types, the group under the age of 10 that begins to expose environment factor affect on vision (the average age $8.8{\pm}1.18$) and the age group of 10 to 20 that begins to change refractive power in earnest (the average age $14.1{\pm}2.58$) and the group after the age 20 that began to stabilize vision (the average age $51.8{\pm}17.51$). The visual acuity of dominant eye was higher than non-dominant eye in all age groups. Nevertheless, these results were not statistically significant. Mean astigmatism of dominant eye was smaller than the non-dominant eye, and this is significant, statistically (p=0.017<0.05). Conclusions: It is expected that the balanced eye with a lower level of astigmatism has a more possibility become a dominant eye.

The Development of Stereotest using Gabor Images in 3D Environment: An Explorative Study (3D 환경에서 가보 영상을 이용한 입체 시력 검사도구의 개발: 탐색적 연구)

  • Kham, Keetaek
    • Journal of Broadcast Engineering
    • /
    • v.20 no.6
    • /
    • pp.901-911
    • /
    • 2015
  • Many studies tried to develop a 3D display based stereo test as a substitute for the conventional stereo test. Although many 3D monitor based stereo tests have various advantages over the conventional stereo tests with printed stimuli, they have a crucial limitation in manipulating disparity. The least value for disparity manipulation is one pixel, which is too big to screen the normal stereo acuity in pc environment with a short viewing distance. In this explorative study, a Gabor image was employed as a test stimulus, because its position can be manipulated by changing its phase information, which allows sub-pixel manipulation for disparity. Instead of employing the methods of the conventional stereo tests where measurement was made only once for each of a wide range of disparity values, 10 replications were administrated for each of 6 disparity levels. The results from the test using Gabor images were compared with those using random dot stimulus because the latter stimulus was exactly the same as that of the conventional stereo test. The correlation coefficient between two tests was found to be moderate. After one month later, the whole test was repeated in the same settings. The correlation coefficient between test and retest results from Gabor images was found to be as high as that from a random dot stimulus, implying high test-retest reliability. These results suggest that a Gabor stimulus could be used as a test stimulus for the valid and reliable stereo test, even in the limited condition, such as 3D environment with a short viewing distance and a condition for evaluating the stereo acuity very precisely.

The Visual Acuity and Refraction on Students of Primary School Using Eyeglasses in Kyung-Nam Region (경남지역 안경 착용자 초등학생들의 시력과 굴절)

  • Kim, Douk-Hoon;Mun, Joung-Hak;Kim, Joung-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.345-350
    • /
    • 2006
  • The study of the visual acuity and refraction status was performed to the students of primary school using eyeglasses in Kyung Nam region, Korea. Two hundred sixty three subjects with various styles of ametropia were analyzed the visual acuity and refraction examination by the subjective and objective tools. The results of study were as follows; 1) According to the increase of age of subjects, the visual acuity of binocular in naked eyes was decrease. However ametropia was increase. 2) The high frequency of ametropia types in the binocular was simple myopia, and the next order of high frequency was mixed astigmatism, myopic compound astigmatism, simple hyperopia, and hyperopic compound, respectively. 3) On the power of spherical refractive error of ametropia, the high frequency was -1.00 diopter, and the next order of high frequency was -2.00 diopter, +2.00 diopter, -3.00 diopter, and so on, respectively. 4) According to the increase of subjects ages, the changes of dioptric power of myopic spheric power was increase. however the frequency of the boy and girl was similar results, also the dioptric values of refractive status in binocular was similar results. As the results of this study, we conclude that the relationship of the visual acuity and refractive error status in primary students using eyeglasses was improved.

  • PDF

Implementation of Random Controlling of Convergence Point in VR Image Content Production (VR 영상콘텐츠 제작을 위한 컨버전스 포인트 임의조절 구현)

  • Jin, Hyung Woo;Baek, Gwang Ho;Kim, Mijin
    • Smart Media Journal
    • /
    • v.4 no.4
    • /
    • pp.111-119
    • /
    • 2015
  • As a variety of HMD(Head Mounted Display) has come out, the production of 3D images onto which VR(Virtual Reality) technologies are grafted has been contributed to activating the production of image contents depending on a tangible or immersing type. VR-based image contents have enlarged their applicability across the entertainment industry from animation and game to realistic images. At the same time, the solution development for producing VR image contents has also gained elasticity. However, among those production solutions which have been used until now, fixed stereo camera based photographing has a limit that the binocular disparity of a user is fixed. This does not only restrict a way of expression a producer intends to direct, but also may cause the effect of 3D or space not to be sensed enough as view condition is not considered enough in a user's side. This study is aimed at resolving with skills applying in the latter part of 3D image production the problem that convergence points may be adjusted with restriction, which tends to happen at the time of the production of VR image contents. The later stage of the 3D imaging work analyzes and applies to game engines the significance of adjusting convergence points through the visualization of binocular disparity so that it is available to implement a function that the points could be controlled at random by a user.

Change of Binocular Vision Induced by Longitudinal Chromatic Aberration during Near Work (근거리 작업 시 종색수차에 따른 양안시의 변화)

  • Kim, Se-il;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.219-228
    • /
    • 2015
  • Purpose: The current study was performed to compare the difference in binocular visual function depending on variable background colors at near work. Method: Fifty four adults (18 males, 34 females) who consented to the present study and had no ocular disease, ocular surgery history, strabismus and amblyopia with normal binocular vision were participated into this study. The subjects were asked to read the novels with black letter printed on white, red, green and blue background for 15 min. Then, their heterophoria, AC/A ratio, near point of convergence, accommodation facility, relative accommodation and vergence were measured before and after reading. The difference of measurements were compared. Result: Overall heterophoria was tended to decrease with regardless of background color. AC/A ratio showed a tendency of increase after reading the novels with all backgrounds except white background. Near point of convergence was significantly increased compared to before reading at all background color. Accommodative facility of dominant and non-dominant eyes were also significantly increased after reading however, binocular accommodative facility showed a tendency of decrease. Negative relative accommodation also decreased at all background colors however, the change of positive relative accommodation was not significantly different. In case of vergence, there was significant difference in break point of far BO and recovery point of far BI by the wavelength of background color. Conclusions: From the results, it was known there is convergence change depending on the wavelength of light even though same amount of accommodation and convergence is required when doing near work for certain period. Thus, it can be suggested that the adjustment of the near working environment which perception of various color was required, should be conducted according to the main wavelength.