• 제목/요약/키워드: 양극성 하전 입자

검색결과 3건 처리시간 0.03초

양극성으로 하전된 에어로졸 입자의 응집에 관한 연구 (Coagulation of Bipolarly Charged Aerosol)

  • 박성훈;이규원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.205-206
    • /
    • 2001
  • 대기중 에어로졸 혹은 미세입자 제조과정에서 생성되는 에어로졸은 전하를 띠게 되는 경우가 많다. 특히 연소공정에서 나오는 배출가스에 포함된 에어로졸은 대부분 하전된 상태로 존재한다. 에어로졸 입자들의 하전량은 응집속도에 영향을 미치게 되고, 결과적으로 입자크기분포의 변화에 큰 변수로 작용하게 된다. (중략)

  • PDF

DBD(Dielectric Barrier Discharge)에 의해 하전된 나노입자의 양극성 대전량 분포 (Bipolar Charge Distribution of Nano Particles Passing through the Dielectric Barrier Discharge Reactor)

  • 지준호;강석훈;변정훈;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1684-1689
    • /
    • 2003
  • Dielectric Barrier Discharges (DBD) in oxygen and air are well established for the production of large quantities of ozone and are more recently being applied to a wider range of after treatment processes for HAPs(Hazardous Air Pollutants). The potential use as a charger for particle collection are not well known. In this work, we measured charge distribution of nanometer or submicron sized particles passing through the dielectric barrier discharge reactor. The bipolar charge characteristics of particles passing DBD reactor were investigated. Fluorometric method using uranine particles and a fluorometer was employed to examine the bipolar charging characteristics of the charged particles by DBD reactor. Finally, the charge distributions of particles were determined from the electrical mobility classification using DMA.

  • PDF

AC 전기장내 하전 액체 입자의 응집에 관한 실험적 연구 (Experimental Study on Electrical Agglomeration of Liquid Particles in an Alternating Electric Field)

  • 지준호;황정호;배귀남;김용진
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.442-450
    • /
    • 2001
  • Experiments were carried out on agglomeration of bipolarly charged particles in an alternating current electric field. Laboratory-scale setup was built and experiments were conducted at atmospheric condition. DOS(Di-octyl Sebacate) particles with 100% purity were generated by an atomizer. The particles were branched into two, each of which passed through a wire-to-plate type charging section where a positive or a negative DC high voltage was applied and was charged positively or negatively. These bipolarly charged particles together passed through an agglomeration section where an $\pm$20kV AC power was applied between two plates. The resident time in the agglomeration section was adjusted as l sec. Particle sampling was made by a cascade impactor (MOUDI). The effect of agglomeration system on the reduction ratio of particles below l ㎛ was 42∼45%. Effect of AC frequency on the particle size distribution was found insignificant.