• Title/Summary/Keyword: 야간 평균기온

Search Result 44, Processing Time 0.029 seconds

Impact of the Local Surface Characteristics and the Distance from the Center of Heat Island to Suburban Areas on the Night Temperature Distribution over the Seoul Metropolitan Area (수도권 열섬 중심으로부터 교외까지의 거리 및 국지적 지표특성이 야간 기온분포에 미치는 영향)

  • Yi, Chae-Yeon;Kim, Kyu-Rang;An, Seung-Man;Choi, Young-Jean
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.1
    • /
    • pp.35-49
    • /
    • 2014
  • In order to understand the impacts of surface characteristics and the distance from the urban heat island center to suburban areas on the mean night time air temperature, we analyzed GIS and AWS observational data. Spatial distributions of mean night time air temperature during the summer and winter periods of 2004-2011(six years) were utilized. Results show that the temperature gradients were different by distance and direction. We found high correlation between mean night-time air temperature and artificial land cover area within 1km and 200m radii during both summer(R=0.84) and winter(R=0.78) seasons. Regression models either from 1km and 200m land surface data explained the distribution of night-time temperature equally well if the input data had sufficient resolution with detailed attribute including building area and height.

대구와 추풍령의 도시화에 따른 야간냉각율 비교 연구

  • Park, Myeong-Hui;Kim, Hae-Dong;Lee, Bu-Yong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.113-120
    • /
    • 2007
  • 대구와 추풍령이 겨울철(2005년 12월${\sim}$2006년 2월)과 여름철(2006년 6월${\sim}$8월) 시간대별 일 최고기온, 일 최저기온, 일 평균기온과 풍속자료를 사용하였다. 추풍력은 대구에 인접해 있으면서 도시화의 영향을 상대적으로 매우 적게 받은 지역이다. 대상일은 대구와 추풍령의 겨울철과 여름철을 대상으로 일 최고기온과 다음날의 일 최저기온간의 차이가 $10^{\circ}C$이상인 날을 선정하고, 그 중에서 운량이 30%이하인 맑은 날을 선정하였다. 그리고 선정일을 대상으로 도심과 교외지역 야간(익일 18시${\sim}$다음날 06시까지)의 기온 냉각율을 조사한 결과는 다음과 같다. 기온하강은 두 지점 모두 풍속의 영향을 받음을 알 수 있었고, 또한 도시구조물이 많은 대구(도심)의 경우는 풍속이 강하더라도 건물에 의한 축열과 복사냉각의 억제에 기인하는 것으로 판단된다. 00시까지는 풍속과 냉각율이 비례하며 현열수송으로 냉각되고, 그 이후부터 일출까지는 풍속과 냉각율이 반비례하여 현열수송에 의한 가열의 경향을 확인할 수 있었다.

  • PDF

Effects of Beehives Number on Inside Temperature of Wintering Beehouse (저장봉군수가 저온양봉사 내부온도에 미치는 영향)

  • 이석건;김란숙;이현우;이종원
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.88-89
    • /
    • 2001
  • 꿀벌의 실내월동에 이용되는 월동용 저온양봉사의 내부환경에 영향을 주는 요소에는 외기온, 저장봉군수, 환기량 등이 있다. 이러한 환경요인을 고려하여 설계 제작된 국내 월동용 저온양봉사의 성능 및 저장봉군수와 양봉사 내부온도의 관계를 분석하고자 경상북도의 7개 지역에 설치된 월동용 저온양봉사(내부크기 폭4.5m×길이3m×높이3m)에 대하여 2000. 11. 25부터 2001, 2. 15까지 실내월동 실험을 수행하였다. 실험대상 지역은 포항, 문경, 상주, 칠곡, 성주, 영양, 안동이며, 지역별 저장봉군수는 각각 14, 74, 85, 110, 163, 170, 260군이다(Table 1). 꿀벌의 월동기간 중 안동과 성주지역을 제외한 5개 지역의 실내 월동성적은 폐사율이 10%미만으로 대체적으로 우수한 것으로 조사되었으나, 월동기간중 지역별 외기온을 분석한 결과, 평균외기온 및 최저외기온이 가장 낮은 지역은 안동이었으며, 그 값이 각각 -3.1℃와 -9.4℃일 때 양봉사 내부의 평균온도와 최저온도는 5.2℃와 3.8℃로 나타났다. 반면에 평균외기온 및 최저외기온이 가장 높은 지역은 포항이었으며 그 값이 각각 1.3℃와 -4.1℃일 때 양봉사 내부의 평균온도와 최저온도는 각각 3.1℃와 1.2℃로 나타나 저온양봉사 내부의 온도환경 조절성능이 모두 우수한 것으로 판단되었다(Table 1). 또한 월동기간중 주.야간으로 양봉사 내.외부의 온도변화를 분석한 결과, 저장봉군수의 증가에 따라 주야간 모두 양봉사 내.외부 온도편차가 증가하는 경향을 나타내었으며 양봉사 내부의 주.야간 평균온도는 모두 꿀벌의 월동에 적정한 범위인 2℃-9℃를 유지하는 것으로 분석되었다(Table 2). 그리고, 월동기간중 외기온이 가장 낮은 시기(1월 13-19일)의 평균 외기온이 -8℃--9℃로 유사한 문경, 상주, 영양, 안동지역의 월동용 저온양봉사의 평균 내부온도는 각각 -2.0℃, -1.0℃, 0.2℃, 4.2℃로 나타나 저장봉군수가 증가함에 따라 월동용 저온양봉사의 내부온도가 증가하여 꿀벌의 월동에 적합한 온도범위를 유지함을 알 수 있었다. 실험기간동안 대부분의 저온양봉사 내부온도는 꿀벌이 월동하기에 적정한 온도범위(2℃-9℃)로 유지하였다(Fig. 1).

  • PDF

Characteristics of Nocturnal Cooling at a Pear Orchard in Frost-Prone Area (서리상습지 배 과수원에서의 야간 냉각 특성)

  • 황규홍;이정택;윤진일;허승오;심교문
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.3 no.4
    • /
    • pp.206-214
    • /
    • 2001
  • Cooling rate shows the highest as about 0.7$^{\circ}C$/hr on spring season and the lowest as about 0.3$^{\circ}C$/hr on september at plain place. The correlation coefficient between net radiation and cooling rate from sunrise to sunset was 0.63$^{**}$, It became higher to 0.90$^{**}$ when the wind speed decreased lower than 0.5 m/sec, and it decreased as the wind speed increased. On a clear and calm day, cooling rates were observed as 1.4$^{\circ}C$/hr on the plain (site 1, 2, 3), 1.2$^{\circ}C$/hr on the slope (site 4, 5) and 0.6$^{\circ}C$/hr on the top of mountain (site 6). In condition of the wind speed is 1.2~2 m/sec on a clear and calm day and the temperature on the top of mountain is lower than that of slope and plain, the temperature on the slope (site 4,5) was increased unlike our expectation.ion.

  • PDF

Estimation of Temporal Surface Air Temperature under Nocturnal Inversion Conditions (야간 역전조건 하의 지표기온 경시변화 추정)

  • Kim, Soo-ock
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.75-85
    • /
    • 2017
  • A method to estimate hourly temperature profiles on calm and clear nights was developed based on temporal changes of inversion height and strength. A meteorological temperature profiler (Model MTP5H, Kipp and Zonen) was installed on the rooftop of the Highland Agriculture Research Institute, located in Daegwallyeong-myeon, Pyeongchang-gun, Gangwon-do. The hourly vertical distribution of air temperature was measured up to 600 m at intervals of 50 m from May 2007 to March 2008. Temperature and relative humidity data loggers (HOBO U23 Pro v2, Onset Computer Corporation, USA) were installed in the Jungdae-ri Valley, located between Gurye-gun, Jeollanam-do and Gwangyang-si, Jeollanam-do. These loggers were used to archive measurements of weather data 1.5 m above the surface from October 3, 2014, to November 23, 2015. The inversion strength was determined using the difference between the temperature at the inversion height, which is the highest temperature in the profile, and the temperature at 100 m from the surface. Empirical equations for the changes of inversion height and strength were derived to express the development of temperature inversion on calm and clear nights. To estimate air temperature near the ground on a slope exposed to crops, the equation's parameters were modified using temperature distribution of the mountain slope obtained from the data loggers. Estimated hourly temperatures using the method were compared with observed temperatures at 19 weather sites located within three watersheds in the southern Jiri-mountain in 2015. The mean error (ME) and root mean square error (RMSE) of the hourly temperatures were $-0.69^{\circ}C$ and $1.61^{\circ}C$, respectively. Hourly temperatures were often underestimated from 2000 to 0100 LST the next day. When temperatures were estimated at 0600 LST using the existing model, ME and RMSE were $-0.86^{\circ}C$ and $1.72^{\circ}C$, respectively. The method proposed in this study resulted in a smaller error, e.g., ME of $-0.12^{\circ}C$ and RMSE of $1.34^{\circ}C$. The method could be improved further taking into account various weather conditions, which could reduce the estimation error.

Spatial Distribution Patterns of Winter Daytime and Nighttime Apparent Temperature in South Korea (남한의 겨울철 주.야간 체감 온도의 공간적 분포 특성)

  • 최광용;강철성
    • Journal of the Korean Geographical Society
    • /
    • v.37 no.3
    • /
    • pp.237-246
    • /
    • 2002
  • This study classified wintertime bioclimatic zones of South Korea based on daytime and nighttime distribution of wind chill index calculated from climate data during the coldest month for latest 30 years (1971- 2000). The results show that the winter daytime and nighttime wind chill index were influenced by climatic factors such as elevation, land-sea breeze, topology, and sea currents etc. as well as climatic components such as temperature, wind speed, and sunshine, so that South Korea was divided into five bioclimatic zones; Cool day- cold night zone, Keen day- Cold night zone, Keen day-Very Cold night zone, Cold day and night zone, and Cold day-Extremely Cold night zone. Especially, coasts and island areas, except for south coast of Korea, shows Keen bioclimatic response during daytime and Very Cold bioclimatic response during nighttime. This indicates that coasts and island areas, except for south coast of Korea are affected by moonson and land-sea breeze. In addition, highly elevated Daegwallyeong shows Cold bioclimatic response during daytime and Extremely Cold during nighttime due to the influence of adiabatic temperature lapse rate and monsoon. This study offers basic data necessary to make decisions concerning insulation such as clothing and architect etc. by classifying winter bioclimatic zones of South Korea based on various daytime and nighttime distribution of wind chill.

Spatial-Temporal Patterns and Recent Changes of Tropical Night Phenomenon in South Korea (우리나라 열대야 현상 발생의 시.공간적 특징과 최근의 변화)

  • Choi, Cwangyong;Kwon, Won-Tae
    • Journal of the Korean Geographical Society
    • /
    • v.40 no.6 s.111
    • /
    • pp.730-747
    • /
    • 2005
  • This study examines relationships between climatic factors and spatial-temporal patterns and recent changes of tropical night phenomenon(TN) occurring through nighttime stages in South Korea. Frequencies of daily TN at different times of night are extracted from long term(1973-2004) 6 hourly nighttime(9PM and 3AM) temperature and daily minimum temperature data at 61 weather stations. Temporally, the occurrences of TN are more pronounced in the evening(9PM) and during the Changma Break period(late July - early August). Spatially, the TNs in the evening frequently occur in the urbanized inland cities at low latitudes due to urban heat islands, whereas the TNs in the middle of night(3AM) or at dawn frequently appeared along the coastal areas within 30km from ocean due to the thermal inertia of ocean. By contrast, the evening(dawn) TN is not seen in the highlands whose elevation is greater than 800m(300m) along the Taebaek and Sobaek mountain ridges due to temperature lapse rates with height Correlation and multivariate regression analyses reveal that the impacts of human or physical climatic factors, such as latitude, elevation, proximity to ocean, and population density, are diverse on the frequencies of TN according to nighttime stages. Recent temporal changes of the late Changma period and intensified urbanization during the 1990s have increased the occurances of TN in urban areas. Therefore, strategies to mitigate the increasing urban TN should be prepared in the near future.

Influences of DIF on Growth and Development of Plug Seedlings of Lycopersicon esculentum before and after Transplanting (주야간 온도차(DIF)에 따른 토마토 플러그묘의 생장과 정직후 생육)

  • 임기병;손기철;정재동
    • Journal of Bio-Environment Control
    • /
    • v.6 no.1
    • /
    • pp.34-42
    • /
    • 1997
  • Effects of DIF on stem elongation in plug seedlings of mini tomato ‘Mini Carol’ and on the growth and flowering after transplanting were investigated. Stem elongation of seedlings was mainly influenced by day temperature rather than night temperature. When the effect of +DIF was compared to that of -DIF under the same average daily temperature(ADT), day temperature had greater impact on internode elongation than night temperature. On the other hand, leaf unfolding rate increased and compactness decreased as ADT in creased. Differences in internode length affected by DIF during seedlings stage DIF progressively diminished during growth period after transplanting. Node position at which first flower was initiated was lowered as ADT decreased. It was concluded that DIF treatment was an applicable tool for control of stem elongation, particularly to reduce stem length without a noticeably adverse effect on the growth and development of plant after transplanting.

  • PDF

Structure and Experimental Results of Automatic Insulation Greenhouse (자동단열온실의 구조 및 운전특성)

  • 이종원;이석건;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1994.05a
    • /
    • pp.88-91
    • /
    • 1994
  • 최근 국내에서도 시설원예가 급격하게 보급되고 있는 실정이다. 하지만, 시설원예가 에너지 소비형의 농경방식이라 지적되고 있는바 에너지절약형 온실의 개발이 필요할 것으로 판단되어, 본 실험실에서는 본 연구와 관련하여 비닐하우스의 벽체를 이중으로 하여 이중벽사이에 단열입자를 송풍기의 케이싱내로 직접 통하게하는 직송방식으로 충전ㆍ회수하는 실험을 실시한 바가 있으며, 그 결과 외기온의 평균이 -4.9$^{\circ}C$인 겨울철 야간에 입자를 충전한 이중비닐 하우스의 내부온도는 평균 9.8$^{\circ}C$로 단열성이 우수함을 알 수 있었다.(중략)

  • PDF

The Variation of Air Temperature and Humidity of Rock Bed Storage for Solar-Heated Greenhouse in Summer Season (여름철 자갈축열 태양열 온실의 축열층 온.습도 변화)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.128-131
    • /
    • 2000
  • 자갈축열 태양열 온실에 있어 여름철 냉방에너지의 효과적인 절감 방안을 모색하고자 축열 및 배기시스템의 작동방식을 다르게 하여 주ㆍ야간 축열과 방열시 자갈축열층의 온습도환경을 분석한 결과를 요약하면 다음과 같다. 1. 주간에 외기온이 28.5$^{\circ}C$-35.3$^{\circ}C$범위에서 변화할 때 자갈축열층내로 유입되는 공기의 온도는 30.5$^{\circ}C$-36.2$^{\circ}C$, 자갈축열층에서 온실내부로 유출되는 공기의 온도는 28.2$^{\circ}C$-30.1$^{\circ}C$, 축열층 내부온도는 27.4$^{\circ}C$-35.9$^{\circ}C$ 범위였다. 또한, 10시간 축열시 자갈축열층 내부온도는 측점에 따라 1.7$^{\circ}C$-7.$0^{\circ}C$의 온도상승이 있었으며 유입구에서 멀어질수록 축열층 온도는 낮게 나타났으며 온도상승 속도 또한 감소하는 경향으로 나타났다. 그리고, 야간에 축열시스템을 작동하지 않고 배기팬만을 작동하였을 경우, 외기온이 27.4$^{\circ}C$-34.4$^{\circ}C$범위일 때 자갈축열층 내부온도는 29.7$^{\circ}C$-34.9$^{\circ}C$(평균 31.4$^{\circ}C$)범위였으며 온실외부에 설치되어 있는 배기구와 배기팬의 영향으로 축열층 내부온도는 시간이 경과함에 따라 감소하는 경향으로 나타났으며 측점에 따라 2.2$^{\circ}C$-5.1$^{\circ}C$(평균 2.8$^{\circ}C$)의 온도하강 효과가 있는 것으로 나타났다. 2. 여름철 주간에 10시간 축열시 자갈축열층 내부습도는 측점에 따라 8.1%-26.3%의 감소현상이 있었다. 또한, 유입구에서 멀어질수록 축열층 습도는 높게 나타났으며 습도하강속도 또한 감소하는 경향으로 나타나 유입구에서 멀어질수록 외부습도의 영향을 적게 받는 것으로 분석되었다. 하지만, 야간에는 배기시스템의 영향으로 자갈축열층의 습도는 외기의 영향을 많이 받는 것으로 나타났다.

  • PDF