• Title/Summary/Keyword: 액체공기

Search Result 284, Processing Time 0.021 seconds

Development and Validation of a Measurement Technique for Interfacial Velocity in Liquid-gas Separated Flow Using IR-PTV (적외선 입자추적유속계를 이용한 액체-기체 분리유동 시 계면속도 측정기법 개발 및 검증)

  • Kim, Sangeun;Kim, Hyungdae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.549-555
    • /
    • 2015
  • A measurement technique of interfacial velocity in air-water separated flow by particle tracking velocimetry using an infrared camera (IR-PTV) was developed. As infrared light with wavelength in the range of 3-5 um could hardly penetrate water, IR-PTV can selectively visualize only the tracer particles existing in depths less than 20 um underneath the air-water interface. To validate the measurement accuracy of the IR-PTV technique, a measurement of the interfacial velocity of the air-water separated flow using Styrofoam particles floating in water was conducted. The interfacial velocity values obtained with the two different measurement techniques showed good agreement with errors less than 5%. It was found from the experimental results obtained using the developed technique that with increasing air velocity, the interfacial velocity proportionally increases, likely because of the increased interfacial stress.

Experimental Determination of Closed Cup Flash Point of Binary Flammable Solutions, 2-Propanol+Propionic acid and n-Hexanol+Formic Acid Solutions (가연성 이성분계 용액인 2-Propanol+Propionic acid 와 n-Hexanol+Formic acid 용액의 밀폐식 인화점의 실험적 결정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.18-24
    • /
    • 2015
  • The flash point is one of the most important indicators of the flammabiliy of liquid solutions. The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. In this study the flash points of binary flammable solutions, 2-propanol+propionic acid and n-hexanol+formic acid systems, were measured using Seta flash closed cup tester. Particularly n-hexanol+formic acid system exhibited minimum flash point behavior. The measured values were compared with the calculated values using Raoult's law and optimization method. The calculated data by optimization method described the measured values more effectively than those calculated by Raoult's law.

Design Method and Preliminary Data Analysis of Subscale Direct-Connect Test Facility for Liquid Ramjet Combustor (I) (액체 램제트 엔진용 소형 연소기 직접 연결식 시험장치의 설계 방법과 시험 데이터 분석 (I))

  • 성홍계;김인식;이규준;김경무;이도형;변종렬;황용석;오석진;한정식
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.59-63
    • /
    • 2003
  • This paper describes the conceptual design method of subscale direct-connect test facility for liquid fuel ramjet combustion study and preliminary analysis of test results. The measured pressure signal represents the successful operation of the test facility. The pressure oscillation in combustion chamber shows the dominant frequency of 190Hz, relatively very low frequency to 1L acoustic mode (1200Hz) based on the length of combustor. It is suspected that there were several driving sources, which are vortex street at backward step of combustor, inlet resonance induced by the long length of unchecked inlet, and/or combustor configuration with optical window.

  • PDF

A Rapid Method for the Measurement of the Absolute Activity of Carbon-14 in Pea Plant Tissue

  • Kendall, F.H.;Park, Chang-Kyu;Mer, C.L.
    • Applied Biological Chemistry
    • /
    • v.18 no.2
    • /
    • pp.56-60
    • /
    • 1975
  • A rapid method for the measurement of the absolute activity of carbon-14 in cotyledons and root of etiolated pea seedlings has been developed. Fresh tissue was frozen in liquid air, ground and suspended in gel phosphor and subjected to measurement for its radioactivity by liquid scintillation counter. Apparent activity of the suspended tissue sample calculated by counting efficiency value obtained by internal standardisation, was found to be related to absolute activity of the tissue, determined by flask combustion technique, by a constant factor. Once this factor is determined experimentally, analysis of C-14 lebelled tissue involves only fairly simple suspension counting by liquid scintillation counter. Present method appears to be applicable to other tissues tagged with C-14.

  • PDF

Numerical Analysis of Detonation of Kerosene-Air Mixture and Solid Structure (케로신-공기 혼합물의 데토네이션 모델과 구조체 모델을 통한 금속관의 수치해석)

  • Lee, Younghun;Gwak, Min-Cheol;Yoh, Jai-Ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.29-37
    • /
    • 2015
  • This paper presents a numerical investigation on detonation of a kerosene-air mixture in the copper tube and the structural response associated with combustion instability in liquid rocket engine. A single step Arrehnius rate law and Johnson-Cook strength model are used to describe the chemical reaction of kerosene-air mixture detonation and the plastic deformation of the copper tube. The changes of flow field and tube stress which are induced by plastic deformation, are investigated on the different tube thicknesses and nozzle configurations.

Measurement of Lower Flash Point for Ternary Mixture, n-Nonane+n-Decane+n-Dodecane System (삼성분계 혼합물인 n-Nonane+n-Decane+n-Dodecane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.31-36
    • /
    • 2016
  • The flash point is one of the most important indicators of the flammability of liquid solutions. The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. In this study the flash points of ternary liquid solutions, n-nonane+n-decane+n-dodecane system, were measured using Seta flash closed cup tester. The measured values were compared with the calculated values using Raoult's law and empirical equation. The calculated data by empirical equation described the measured values more effectively than those calculated by Raoult's law.

Filmwise Reflux Condensation Length and Flooding Phenomena in Vertical U-Tubes (수직U-자관 속에서의 액체막 역류 응축 길이와 Flooding현상)

  • Moon-Hyun Chun;Jee-Won Park
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 1985
  • A two inverted U-tubes condenser was constructed from transparent materials to study the heat removal capability of steam generators under filmwise reflux condensation mode. Essentially, two sets of experiments were performed: (1) the first dealt with the reflux condensation length, and (2) the second dealt with the flooding points with and without the presence of a noncondensible gas in the steam flow, and the effect of the flooding time. In addition, experimental results are compared with the predictions of analytical models.

  • PDF

Study on the Deactivation Trends of Liquid Fuel According to the Types of Endothermic Catalyst in Flow Reactor (흐름형 반응기 내에서 액체연료의 흡열반응촉매 종류에 따른 비활성화 정도에 대한 연구)

  • Lee, Tae Ho;Jeon, Sunbin;Kim, Sung Hyun;Jeong, Byung Hun;Han, Jeong Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.81-87
    • /
    • 2018
  • In hypersonic aircraft, increase of aerodynamic and engine heat lead thermal load in airframe. It could lead structural change of aircraft's component and malfunctioning. Endothermic fuels are liquid hydrocarbon fuels which absorb the heat load by undergoing endothermic reactions. In this study, we investigated the relationship between product, coke formation and catalytic properites of endothermic catalysts by using exo-tetrahydrodicyclopentadiene as a fuel in a fixed bed flow reactor similar to the actual reaction conditions.

Induction and growth of adventitious roots and bioreactor culture in Codonopsis lanceolata (더덕 (Codonopsis lanceolata)의 부정근 유도 및 생장에 미치는 배양조건과 생물반응기 배양)

  • Ahn, Chang-Ho;Bae, Kee-Hwa;Yi, Jae-Seon;Choi, Yong-Eui
    • Journal of Plant Biotechnology
    • /
    • v.35 no.2
    • /
    • pp.155-161
    • /
    • 2008
  • This paper reported the establishment of mass production system of adventitious roots of Codonopsis lanceolata through shake flask and bioreactor culture. Induction of adventitious roots was started from the explants of leaf, stem and root on 1/2 strength Murashing and Skoog (MS) solid medium. Stem segments were the best explants for induction of adventitious roots compared to leaf and root segments. Among the different auxins tested (NAA, IBA and IAA), number of adventitious root per explant was highest on solid medium with 1.0 mg/L IBA, and produced $9.9{\pm}1.2$ roots per explant. However, growth of adventitious roots was fast in the presence of IBA at low concentration (0.1 mg/L). In shake flask culture, maximum production of adventitious roots (fresh weight) was obtained in half-strength MS medium compared to full-strength and one-third MS medium. When the adventitious roots produced in shake-flask culture were transferred to 5 L air-lift bioreactor, 16 times of fresh weight increase was gained after one month of culture. These results indicate that this protocol for the production of C. lanceolata adventitious roots can be applied to large scale culture for practical application.

Studies of application of artificial ground freezing for a subsea tunnel under high water pressure - focused on case histories - (고수압 해저터널 건설을 위한 동결공법 적용성에 관한 연구 - 사례를 중심으로 -)

  • Son, Young-Jin;Lee, Kyu-Won;Ko, Tae Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.5
    • /
    • pp.431-443
    • /
    • 2014
  • In this paper case studies of artificial ground freezing, which have not been applied in Korea, have been investigated for the water cut-off in a subsea tunnel under high water pressure and the most commonly used cooling mediums of brine and liquid nitrogen are examined. Since sea water with pressure has the lower freezing point than pure water, the lower temperature cooling medium is required in the application of subsea tunnel. Also, the cooling medium must have refrigeration safety and is able to reduce executing time. Brine freezing system can reuse cooling medium and is safer than liquid nitrogen freezing. But it takes more time to freeze ground and needs complex circulation plants. On the other hand, liquid nitrogen freezing system can't recycle cooling medium and may cause breathing problems or asphyxiation through oxygen deficiency. But, freezing with liquid nitrogen is fast and requires simple refrigeration equipment. Principal elements of design for ground freezing in subsea tunnel have been extracted and these elements are needed further research.