• Title/Summary/Keyword: 압축성 인자

Search Result 186, Processing Time 0.025 seconds

A Study on Removal Efficiency of VOCs using Vortex Cyclones (보텍스 사이클론을 이용한 VOCs 제거효율에 관한 연구)

  • Lim, Gye-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.194-199
    • /
    • 2005
  • The principle of vortex cyclone was applied to enhance the treatment efficiency of waste air streams containing particulate matters, phenol, and others. Adsorption, condensation, and/or coagulation could be induced at low temperature zone formed by Joule-Thomson expansion as the pressurized air and pulverized activated carbon were introduced at the tangential direction into the cyclone system applied with the coaxial funnel tube of vortex cyclone. Easily condensible vapors were adsorbed and/or condensed forcibly on coagulated or condensed materials which were formed as cores for coagulation or condensation by themselves or on pulverized activated carbons. These types of coagulation or condensation rates were rapidly promoted by increase in their diameter. The maximum removal efficiency obtained from this experiment for the removal of carbon dioxide and phenol was about 87.3 and 93.8 percent, respectively. Phenol removal efficiency was increased with the relative humidities and enhanced by pulverized activated carbon added. The Joule-Thomson coefficients were increased with the pressure of air injected in the range of the relative humidities between 10% and 50%. It is believed that the moisture, particulate matters, and the pressure of the process air introduced could control the removal efficiency of VOCs.

A Study on Evaluation of Rock Brittleness Index using Punch Penetration Test (압입시험을 이용한 암석의 취성도 평가에 관한 연구)

  • Hoyoung Jeong
    • Tunnel and Underground Space
    • /
    • v.33 no.1
    • /
    • pp.29-41
    • /
    • 2023
  • The brittleness of rocks plays an important role in determining the fragmentation and failure behavior of rock. However, there is still no standard method to evaluate the brittleness of rock, and previous studies have suggested the several definitions for estimation of brittleness of rock. Even in the process of mechanical rock excavation and drilling, the brittleness of rock is considered as an important property for evaluating the excavation efficiency of mechanical excavators or boreability of rock. The previous studies have been carried out to investigate the correlation between different brittleness of rock and cutting efficiency and boreability of rock. This study introduced a method for calculating the brittleness of rock from punch penetration test, and analyzed the correlation between the brittleness of rock calculated by the uniaxial compressive and Brazilian tensile strengths and that from punch penetration test. From the results of correlation analysis, the relationship between various brittleness was confirmed, and it was found that PSI and BI3 showed a good correlation with the strength-based brittleness index. In addition, the results indicated that B3 and B4 are suitable to represent the brittleness of rock in the field of mechanical rock excavation.

Dynamic Shear Behavior Characteristics of PHC Pile-cohesive Soil Ground Contact Interface Considering Various Environmental Factors (다양한 환경인자를 고려한 PHC 말뚝-사질토 지반 접촉면의 동적 전단거동 특성)

  • Kim, Young-Jun;Kwak, Chang-Won;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.1
    • /
    • pp.5-14
    • /
    • 2024
  • PHC piles demonstrate superior resistance to compression and bending moments, and their factory-based production enhances quality assurance and management processes. Despite these advantages that have resulted in widespread use in civil engineering and construction projects, the design process frequently relies on empirical formulas or N-values to estimate the soil-pile friction, which is crucial for bearing capacity, and this reliance underscores a significant lack of experimental validation. In addition, environmental factors, e.g., the pH levels in groundwater and the effects of seawater, are commonly not considered. Thus, this study investigates the influence of vibrating machine foundations on PHC pile models in consideration of the effects of varying pH conditions. Concrete model piles were subjected to a one-month conditioning period in different pH environments (acidic, neutral, and alkaline) and under the influence of seawater. Subsequent repeated direct shear tests were performed on the pile-soil interface, and the disturbed state concept was employed to derive parameters that effectively quantify the dynamic behavior of this interface. The results revealed a descending order of shear stress in neutral, acidic, and alkaline conditions, with the pH-influenced samples exhibiting a more pronounced reduction in shear stress than those affected by seawater.

Separation Permeation Characteristics of N2-O2 Gas in Air at Cell Membrane Model of Skin which Irradiated by High Energy Electron (고에너지 전자선을 조사한 피부의 세포막모델에서 공기 중의 O2-N2 혼합기체의 분리투과 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.261-270
    • /
    • 2019
  • The separation permeation characteristics of $N_2-O_2$ gas in air at cell membrane model of skin which irradiated by high energy electron(linac 6 MeV) were investigated. The cell membrane model of skin used in this experiment was a sulfonated polydimethyl siloxane(PDMS) non-porous membrane. The pressure range of $N_2$ and $O_2$ gas were appeared from $1kg_f/cm^2$ to $6kg_f/cm^2$. In this experiment(temperature $36.5^{\circ}C$), the permeation change of $N_2$ and $O_2$ gas in non-porous membrane by non-irradiation were found to be $1.19{\times}10^{-4}-2.43{\times}10^{-4}$, $1.72{\times}10^{-4}-2.6{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. That of $N_2$ and $O_2$ gas in non-porous membrane by irradiation were found to be $0.19{\times}10^{-4}-0.56{\times}10^{-4}$, $0.41{\times}10^{-4}-0.76{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. The irradiated membrane was significantly decreased about 4-10 times than membrane which was not irradiated. And ideal separation factor of $N_2$ and $O_2$ gas by non-irradiation was found to be from 1.32 to 0.42 and that of $N_2$ and $O_2$ gas by irradiation was found to be from 0.237 to 0.125. The irradiated membrane was significantly decreased about 4-5 times than membrane which was not irradiated. When the operation change(cut) and pressure ratio(Pr) by non-irradiation were about 0, One was increased to the oxygen enrichment and the other was decreased to the oxygen enrichment. The irradiated membrane was significantly decreased about 4-19 times than membrane which was not irradiated. As the pressure of $N_2$ and $O_2$ gas was increased, the selectivity was decreased. As separation permeation characteristics of $N_2-O_2$ gas in cell membrane model of skin were abnormal, cell damages were appeared at cell.

Estimation of Compressive Strength for Existing Concrete Structures by Non-Destructive Tests (비파괴시험에 의한 기존 콘크리트 구조물의 압축강도 추정)

  • 구봉근;오병환;김영의;김태봉;한승환
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.6
    • /
    • pp.159-172
    • /
    • 1994
  • The relmund hammer test and ultrasonic pulse velocity test methods are commonly used to determine the in-situ compressive strength of concrete. One of the special feature of these methods is that they cannot give consistent and reliable results for variety of structures. In particular, very old existing structures have been generally received sreious environmental affectsand thus the strength prediction will be different from normal structures. The purpose of the present study is, therefore, to propose realistic equations to predict the in-situ strengths of actual old concrete structures. The rebound hammer and ultrasonic pulse velocity tests, carbonation depth measurments and core compressive strength measurements have been carried out for very old hydraulic and seacoast concrete structures spanning from one to about seventy years in age. From these test results, the strength-rebound number relations, the strength-pluse velocity relatinns and the strength-rebound number-pluse velocity relations have been obtained through multiple regression analysis. The present study indicates that the existing equations by nondestructive tests give quite different results from the present data. The proposed equations reasonably well predict the measured data for old concrete structures, especially for low strength concrete. The prediction equations proposed here can be efficiently used in determining the in-situ strength of old concrete structures.

A Study on Applicability of Tensile Constitutive Model of Steel Fiber Reinforced Concrete in Model Code 2010 (Model Code 2010에 제시된 강섬유 보강 콘크리트의 인장 구성모델 적용성 고찰)

  • Yeo, Dong-Jin;Kang, Duk-Man;Lee, Myung-Seok;Moon, Do-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.581-592
    • /
    • 2016
  • Tensile constitutive stress-strain model of steel fiber reinforced concrete (SFRC) in fib MC2010 was investigated. In order to model tensile behavior of SFRC, three point loading flexural tests were conducted on notched small beams according to BE-EN-14651. Design parameters for the constitutive model were determined from the flexural tests. Flexural test and finite element analysis were conducted on large SFRC beam without steel reinforcements and compared with each other. In addition, parametric study on the effect of compressive and tensile model, and characteristic length on flexural behavior of the SFRC beam was conducted also. In results, pre-peak load-displacement curves from the FE analysis was close to experimental curves but significant difference was shown in post-peak behavior. The reason of the difference is originated from the fact that the fiber distribution and orientation were not being properly considered in the MC2010 model. This study shows that modification and detail explanations on the orientation factor K in MC2010 might require to better reproduce the behaviour of large scale SFRC beams.

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (II) : Based on Piping System Stress Analysis (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (II) : 배관 시스템 응력 해석을 이용한 위험도 평가)

  • Yu, Jong Min;Song, Jung Soo;Jeong, Tae Min;Lok, Vanno;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.14-25
    • /
    • 2018
  • The combined cycle power plant has a cycle of operating the gas turbine with fuel, such as natural gas, and then producing steam using residual heat. The fuel gas is supplied to the gas turbine at a level of 4 to 5 MPa, $200^{\circ}C$ through a compressor and a heat exchanger. In this study, the risk assessment method considering the piping system stress was carried out for safe operation and soundness of the gas fuel supply piping system. The API 580/581 RBI code, which is well known for its risk assessment techniques, is limited to reflect the effect of piping stress on risk. Therefore, the systematic stress of the pipeline is analyzed by using the piping analysis. For the study, the piping system stress analysis was performed using design data of a gas fuel supply piping of a combined cycle power plant. The result of probability of failure evaluated by the API code is compared to the result of stress ratio by piping analysis.

A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution (환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구)

  • kim, Nam Suk;Lim, Jae Geun;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • Classification of explosion hazard areas is very important in terms of cost and safety in the workplace handling flammable materials. This is because the radius of the hazardous area determines whether or not the explosion-proof equipment is installed in the electrical machinery and apparatus. From November 6, 2017, KS C IEC-60079-10-1: 2015 will be issued and applied as a new standard. It is important to understand and apply the difference between the existing standard and the new standard. Leakage coefficients and compression factors were added to the leakage calculation formula, and the formula of evaporation pool leakage, application of leakage ball size, and shape of explosion hazard area were applied. The range of the safety factor K has also been changed. Also, in the radius of the hazardous area, the existing standard applies the number of ventilation to the virtual volume, but the revised standard is calculated by using the leakage characteristic value. In this study, we investigated the differences from existing standards in terms of ventilation and dilution and examined the effect on the radius of the hazard area. Comparisons and analyzes were carried out by applying revised standards to workplaces where existing explosion hazard locations were selected. The results showed that even if the ventilation and dilution were successful, the risk radius was not substantially affected.

An Investigation on the Nonlinear Shear Behavior of FRP Composites Considering Temperature Variation and Fabricating Parameters (FRP 복합재료의 온도변화 및 제작인자별 비선형 전단거동 조사)

  • Jung, Woo-Young;Hwang, Jin-Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.833-841
    • /
    • 2013
  • In the case of composite material, a variety of characteristics were expressed depending on the materials that were composed of. In this study, the materials showing non-linear shear behavior were investigated among FRP composite. Each specimen was designed and analyzed according to ASTM D4255 method: regulations on the 2-rail. The dependent variables included in this experiment were a variety of fiber, fiber volume ratio, fiber array direction, temperature, material homogeneity. For determination of characteristics based on the fiber array, fiber array direction of 0, 30, 45, and 60 degrees were selected for test specimen. Temperature of 25, 40, 60, and $80^{\circ}C$ were considered for investigation of FRP materials'shear behavior based on the external temperature. Nonlinear shear behavior was observed throughout the FRP composite material in this study. Also, using vinyl ester resins, high fiber volume ratio, and fiber array direction of 45 degree appeared to show the most prominent nonlinear shear behavior. As for the findings related to the temperature change, non-linear behavior was decreased as the external temperature increased. For factory manufactured product, non-linear behavior was relatively at parity in comparison to the behavior found in the hand lay-up FRP composite specimen.

Crack Source location Technique for nam Concrete Beam using Acoustic Emission (음향방출을 이용한 무근콘크리트 보의 균열 발생원 탐사기법)

  • 한상훈;이웅종;조홍동;김동규
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.107-113
    • /
    • 2001
  • This study was conducted preliminarily to develop the crack source location technique for plain concrete beam using acoustic emission(AE). Before the main experiment, the test of virtual An source location was achieved in plain concrete block. The sensor layout was mutually compared between triangular layout and rectangular layout. As the results of test, AE source location by triangular layout was evaluated more effective than that by rectangular layout. The specimen to apply he source location technique was man in total nine specimens (each three in 40 %, 50%, 60% of W/C ratio) which the experiment variable was the compressive strength level(W/C ratio). The bending loading method is selected by cyclic loadings to evaluate the degree of concrete damage. It is seen that Kaiser effect and Felicity effect exists through analysis of AE parameters in coming failure experiment. As a result of analyzing the felicity ratio(FR) values, it is shown that this values can be used for evaluating the degree of concerto damage. AE activity is started highly at the 70% of failure load without the compressive strength level. Thus considered by a index in constructing the system of the failure warning at application of the field structure. And the results compared the real cracking location with the source location has perceived by AE monitoring before it is appeared the primary crack by visual observation.