• Title/Summary/Keyword: 압전 현상

Search Result 122, Processing Time 0.024 seconds

Fabrication and Characteristics of Piezoelectric transformer using PMN-PZT (PMN-PZT 세라믹을 사용한 압전트랜스포머 제작과 특성)

  • 류주현;손은영;류규현;윤현상;정희승
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.13-20
    • /
    • 1997
  • In this paper, the voltage step-up ratio, efficiency and input impedance of the PMN-PZT cert- mic transformer(PT) were investigated for the variation of resonant frequency according to lead resistance. The output voltage and voltage step-up ratio are increased with the the increase of load resistance. The efficiency of PT showed the maxinum value of 91% at R$_{L}$ of 500k$\Omega$X>

  • PDF

The Application of Ultrasonic Spectroscopy System for Phase Transition of Liquid Crystal (액정의 상전이 측정에 대한 초음파 spectroscopy 시스템의 적용)

  • Kim, Jeong-Koo;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.31-35
    • /
    • 2004
  • A new measuring system for ultrasonic spectroscopy was constructed, utilizing PVDF [poly(vinylidene fluoride)] polymer films as wideband transducers. In a test of its performance, this measuring system was successfully applied to study of the nematic-isotropic phase transition in MBBA(p-methoxybenzylidene-p-n-butylan iline) liquid crystal. We could be confirmed that the phase transition in MBBA is $47^{\circ}C$, which is agree with the exciting optical method. The dependence of frequency on the phase transition was not observed, and but Maximum ultrasonic amplitude is measured for the resonance frequency 2MHz in PVDF transducers, These results shows that the spectroscopy with PVDF transducers takes advantage of studying the transient phenomena. When our apparatus is applied in medical purposes, It will be possible diagnostic for sickle-cell anemia and arterial sclerosis.

  • PDF

대향타겟식 스퍼터법으로 제작된 ZnO/Glass 박막의 결정학적 특성에 관한 연구

  • 금민종;성하윤;공석현;손인환;김경환
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.34-34
    • /
    • 2000
  • ZnO 박막은 대칭 육방정계(hexagonal) wurtzite-type crystal로써 결정구조에서의 이방성, 비화학양론 결합구조와 다양한 전기적, 광학적 그리고 타성파적 성질 때문에 현재 여러 응용분양에서 각광을 받고 있는 재료 중의 하나이다. 이러한 특성을 갖는 ZnO 박막은 결정학적으로 기판에 수직인 c-축 우선방위현상(preferred orientation)을 나타내며 압전 특성을 이용하여 응용을 할 경우 이 c-축 우선방위현상에 따라 압전 특성에 큰 차이가 있으며 ZnO 박막의 형성 조건에 의해 c-축 우성배향성은 큰 차이가 있다. 특히 스퍼터법을 이용하여 ZnO 박막을 형성하는 경우에는 투입전력, 기판온도, 분위기 가스압력, 타겟간 거리등의 증착조건에 의해 결정학적 및 전기적 특성이 크게 영향을 받게 된다. 따라서 결정학적으로 양호하며 고품위의 특성을 갖는 ZnO 박막을 제작하기 위해서는 최적의 증착조건을 확립하여 ZnO 박막을 제작할 필요가 있다. 본 연구에서 사용된 대향 타겟식 스퍼터장치는 두 개의 타겟이 서로 마주보게 배치되어 있고 양 타겟에 수직으로 분포하고 있는 자계가 ${\gamma}$-전자를 구속하게 되어 고밀도의 플라즈마를 형성할 수가 있다. 따라서 10-4Torr에서도 안정한 방전을 유지할 수가 있으며 기판의 위치가 플라즈마로부터 이격되어 (plasma-free)있는 위치에 있기 때문에 플라즈마내의 높은 에너지를 갖는 입자들의 기판충돌을 최대한 억제하여 고품위의ZnO 박막을 제작할 수가 있다. 이러한 특징을 갖는 대향타겟식스퍼터장치를 이용하여 본 연구에서는 비정질 slide glass를 기판으로 하여 ZnO 박막을 증착하였으며 XRD(X-ray Diffractometer)를 이용하여 증착된 ZnO 박막의 결정학적 특성을 측정하였다. ZnO 박막은 산소 가스압력과 기판온도, 인가 전류를 변화시켜가며 증착하였으며 이에 따른 박막의 결정성 변화를 알아보았다. 기판온도를 실온에서 점차 증가시켜나가면 $\Delta$$\theta$50은 급격히 감소하며 30$0^{\circ}C$에서는 결정성이 우수한 막을 얻을 수 있었다. 또한 산소 가스 압력이 0.5~1mTorr에서 $\Delta$$\theta$50은 양호한 값을 나타내었지만 그 이상에서는 c-축 배향성이 나빠짐을 확인하였다. 따라서 대향타겟식스퍼터 장치를 이용하여 ZnO 박막을 증착시 가스압력 0.5~1mTorr, 기판온도 20$0^{\circ}C$이상의 막 제작조건에서 결정성이 우수하게 나타나는 것을 확인할 수 있었다.

  • PDF

Design and Analysis of Square Beam Type Piezo-electric Vibrating Gyroscope (압전세락믹을 이용한 사각보형 진동자이로의 설계, 제작 및 평가)

  • 이정훈;박규연;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.282-286
    • /
    • 1995
  • 일반적으로 관성계 내의 물체에 대한 동적특성의 파악을 위해서는 속도, 가속도 및 각속도, 각가속도에 대한 정보를 필요로 하며 자이로는 이중에서 각속도를 측정하는 장치이다. 운동하는 질량에 회전각속도가 인가될 때 발생되는 코리올리힘을 측정하여 회전각속도를 검출하는 개념의 각속도 센서인 진동자이로는 성능이 회전형 자이로에 비해 떨어지나 구조가 간단하고 소형이며 대량생산이 가능한 장점이 있다. 진동자이로의 효시로는 1950년 영국의 Sperry Gyroscope Company의 "Gyroton"이며, 전자기력을 이용한 가진과 측정이 그 특징으로서 실험실 조건에서 지구의 자전속도를 측정할 수 있었다. 그후 1960년대에 General Electric에서 "VYRO"라는 모델을 개발했는데 압전소자를 이용하여 가진과 측정을 하는 방법이 사용되었다. 1980년대에 Watson Ind., Soderkvist등은 센서자체가 압전물질로 만들어진 자이로를 실험하였고 1990년도에 들어서는 진동자이로의 원리를 마이크로 머시닝 기술과 연계시켜서 소형 경량화와 대량생산을 목표로 연구가 일부 진행되고 있다. 현재 제품화되어 실제 응용되고 있는 예로는 무라다사의 삼각프리즘 형태의 자이로, 토킨사의 원통형 자이로 등이 있으며 이러한 자이로는 캠코더 화면의 안정화 장치에 주로 사용되고 있다. 본 논문에서는 압전소자의 압전, 전왜 방정식으로 출발하여 자이로헤드의 동적 거동을 해석하였다. 진동자이로는 물체의 공진주파수에서의 진동현상을 이용하며, 두 방향의 고유진동수를 일치시켜야 하는 등의 설계조건이 있다. 이러한 조건을 만족하도록 사각보 구조를 기본으로 하여 새로운 형태의 자이로헤드를 고안하였다. 자이로헤드의 구동회로를 설계, 해석하고 각속도를 측정할 수 있는 검출회로를 설계하여 설계된 진동자이로의 동적 특성을 확인하고 보정회로를 이용하여 사용 주파수 영역을 넓혔다.이용하여 사용 주파수 영역을 넓혔다.러한 강이성들이 보장되는 제어이론들 중 H$_{\infty}$ 제어이론이 많이 연구/응용 되고 있다. 특히 공칭 플랜트 모델과 함께 사용되는 플랜트 모델과 함께 사용되는 플랜트 불확실성 모델은 직접적으로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the

  • PDF

Performance Study of Diagonally Segmented Piezoelectric Vibration Energy Harvester (대각선 방향으로 분할된 압전 진동 에너지 수확 장치의 성능 연구)

  • Kim, Jae Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.983-989
    • /
    • 2013
  • This study proposes a piezoelectric vibration energy harvester composed of two diagonally segmented energy harvesting units. An auxiliary structural unit is attached to the tip of a host structural unit cantilevered to a vibrating base, where the two components have beam axes in opposite directions from each other and matched short-circuit resonant frequencies. Contrary to the usual observations in two resonant frequency-matched structures, the proposed structure shows little eigenfrequency separation and yields a mode sequence change between the first two modes. These lead to maximum power generation around a specific frequency. By using commercial finite element software, it is shown that the magnitude of the output power from the proposed vibration energy harvester can be substantially improved in comparison with those from conventional cantilevered energy harvesters with the same footprint area and magnitude of a tip mass.

A Study on the Driving of Ballast for 35W Class (T5 Class) Fluorescent Lamp using a Piezoelectric Transformer Characteristic (압전 변압기 특성을 이용한 35W급(T5급) 형광등용 안정기 구동에 관한 연구)

  • Hwang, Lark-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.638-644
    • /
    • 2008
  • It is required small size electronic ballast to fullfill the design philosophy of miniaturizing in the application of slim lamps. However, the traditional magnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight. In this study, in order to solve these problems, It was proposed for driving 35W Class fluorescent lamp in the new type of electronic ballast, which is composed of rectifier, active power factor corrector, series resonant half bridge inverter and piezoelectric transformer. A 35W class(T5 class) fluorescent lamp is driven to successful by the fabricated ballast with piezoelectric transformer. Experimental results, It is proposed to driving the lamp using a electronic ballast at operating frequency of $75{\sim}79kHz$ approximatively. It is operated after for 25 min that were obtained good results of the input power factor of 0.95 and efficiency of 86%, respectively.

Pb-based piezoelectric thick films prepared by a screen printing (Screen printing에 위한 Pb계 압전세라믹스 후막의 제조)

  • Paik, D.S.;Shin, H.S.;Sim, S.H.;Park, Y.W.;Kang, C.Y.;Shin, H.Y.;Yoon, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1541-1543
    • /
    • 1999
  • Screen printing에 의해 압전 후막을 제조하기 위하여 약 $0.6{\mu}m$의 평균 입자 크기를 갖는 PMN-PZT와 PAN-PZT 분말을 산화물 혼합법에 의해 제조하였다. 치밀한 후막의 제조를 위한 분말과 유기물의 비율은 분산이 가능한 범위에서 80:20 (분말:유기물)의 중량비를 나타내었다 사용된 기판과 하부전극은 각각 $SiO_2$/Si와 AgPd 였으며, 후막 제조시 박리 및 균열현상은 발생되지 않았다. 프린트된 후막은 건조온도와 무관한 미세구조를 나타내었으며, 보다 치밀한 구조를 갖는 후막의 제조를 이해 입자의 분산 및 열처리 조건 그리고 기판과의 매칭에 대해 연구가 계속되어야 할 것으로 생각된다.

  • PDF

Air Supplying System for DMFC using Piezo Actuators (압전 액추에이터를 이용한 DMFC의 공기 공급 시스템)

  • Hong, Chol-Ho;Kim, Dong-Jin;Yun, Hyo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1585-1591
    • /
    • 2010
  • DMFC uses oxygen by reactants. Therefore, cathode electrode must contact with outside air. However, when used in mobile devices, the user's body by blocking the air intake on the oxygen supply DMFC con not. DMFC to supply air to the cooling fan is used. However, by using cooling fan, air inlet to the pressure loss and changes will occurs, the output will be worse. In this paper, we designed air supplying system using piezo actuators. We DMFC evaluation system was implemented, verified the performance of air supplying system. And the operation was connected to an MP3 player.

A Study on T5 28W Fluorescent Lamp Ballast Using a Piezoelectric Transformer and One-chip Microcontroller (One Chip Microcontroller와 압전변압기를 이용한 T5 28W 형광등용 전자식 안정기에 관한 연구)

  • 황락훈;류주현;장은성;조문택;안익수;홍재일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2003
  • In this paper, T5 28-watt fluorescent lamp ballast using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed electronic ballast is composed of basic circuits and blocks, such as rectifier part, active power factor corrector part, frequency oscillation part using microcontroller and feedback control, piezoelectric transformer and resonant half bridge inverters. The fabricated ballast uses to variable frequency methode in external so exciting that the frequency of piezoelectric transformer could be generated by voltage control oscillator using microcontroller(AT90S4433). The current of fluorescent lamp is detected by feedback control circuit. The signal of inverter output is received using Piezoelectric transformer, and then its output transmitted to fluorescent lamp. Traditional electromagnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight. A new electronic ballast is operated at high frequency about 75kHz, and then Input power factor, distortion of total harmonic and lamp current crest factor are measured about 0.9!35, 12H and 1.5, respectively Accordingly, the traditional ballast is by fabricated electronic ballast using piezoelectric transformer and voltage control oscillator because of its lighter weight, high efficiency, economic merit and saving energy.

Scanning Tunneling Microscopy: 표면 과학 연구 장비로부터 일반 고체물리 실험 장비로

  • Guk, Yang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.76-76
    • /
    • 2013
  • Scanning Tunneling Microscopy는 개인용컴퓨터가 보급되고, 저잡음 아날로그 칩들을 구할 수 있으며, 압전세라믹 기술이 발달하기 시작한 1981년 스위스 IBM Zurich 연구소에서 H. Rohrer와 G. Binnig 박사에 의하여 발명되었다. 이 발명 7~8년 이전 미국 표준연구원의 R. Young 박사도 비슷한 시도를 하였지만, 이 때는 제어할 수 있는 컴퓨터가 없었고, 조절 회로의 잡음 레벨도 컸으며, 역학적 진동도 커서 목적을 달성할 수 없었다. STM의 발명 후 32년이 지난 지금, 조절용 컴퓨터의 발전은 물론, 조절용 역되먹임 회로 또한 digital signal processor나 FPGA를 사용하는 형태로 변화하여 전기적 잡음도 현저히 감소하였다 [1,2]. 동시에 측정 에너지 해상도를 개선하기 위하여 세계적으로 여러 그룹이 장치를 1 K 이하에서 작동할 수 있게 제작하였고, 0.3 K에서 작동하는 상업용 제품도 등장하였다. 이 결과 에너지 해상도는 30 meV 에서 2~3 ${\mu}eV$ 감소하였고, 온도변화에 따른 측정 위치의 변화도 피할 수 있게 되었다. 터널링 검침의 화학적 성분을 흡착과 같은 방법으로 조절하여, 공간 해상도는 물론 에너지 해상도도 더욱 줄일 수 있게 되었고, 스핀에 민감한 터널링 제어도 가능하게 되었다. 이제는 금속, 반도체, 초전도체는 물론 분자, 거대분자, 나노 크기의 양자점등도 측정이 가능하게 되었다. 분자진동 측정이 가능하며, 분자의 성분 분석이 가능하게 되었고, 스핀의 전도와 관련된 제반 문제들을 연구할 수 있게 되었다. 지금부터 10년 동안에는 포논의 측정과 전자와 포논 exciton 등이 관여된 다체계 현상, 이들의 동역학적 현상이 측정 가능하게 되었다. 핵자기 공명도 시도되고 있으며 화학적 구명 및 원자들 사이의 결합도 측정 가능하게 될 것이다. 이제 STM은 초고 진공에서 작동하는 Atomic Force Microscopy와 함께 지금까지 고체물리학 실험 장치가 만들어 내지 못하던 새로운 결과를 도출해 낼 것으로 기대한다.

  • PDF