• Title/Summary/Keyword: 압입체적

Search Result 3, Processing Time 0.015 seconds

Indented Surface Configuration and its Volume Calculation (압입 표면형상의 구현과 체적계산법)

  • Yang, Jae-Yong;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.708-713
    • /
    • 2012
  • The indented geometry for rockwell hardness indenter has been configured by using Confocal Laser Scanning Microscopy (CLSM). For this purpose, the CLSM can be well suited to construct the three-dimensional indented volume from the indented surface by rockwell hardness tester. Furthermore, the height data of HEI(height encoded image) by CLSM must be acquired at first and converted to indented surface later. And the indented surface patterns enable us to predict the indenter shape and volume. This volume can be used to study the rockwell hardness model as a volume parameter. As a result, the technique performed in this study by combining the CLSM with compensation technique is an excellent one to obtain the geometries of indented surfaces over a wide range of surface resolution in a micro scale. And it can be used for micro volume calculation.

Evaluation of Buckling in Prestressed Composite Truss Girder using ADINA Structure Analysis (ADINA 구조해석을 이용한 PCT 거더교 좌굴 평가에 관한 연구)

  • Kim, Eui Soo;Kim, Jong Hyuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1415-1421
    • /
    • 2013
  • Recently, to resolve problems regarding legal liability for accidents and disasters, various simulation techniques such as F.E.M. and F.V.M. have been used in the field of forensic engineering. In this study, we performed mechanical structure analysis using ADINA to investigate the cause of bridge collapse accidents. Such accidents occurred owing to modified and missing processes in comparison with the original design while filling with concrete. Modified and missing processes cause buckling of the upper plate and twisting of the main girder. Through this study, we determine the exact cause of bridge collapse by comparing the evaluation of the structure stability of the original design with the evaluation of the structure stability of the modified and missing process using ADINA structure analysis. Hence, this result indicates that buckling prediction through FEA is the most effective method.

Analysis of the Physical Properties of Ground before and after Low Flowing Grouting (저유동성 그라우팅 시공전후 지반의 물성변화 분석)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Kang, Won-Dong;Jung, Euiyoup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.115-127
    • /
    • 2019
  • The low-flow grouting injection technique, the target construction method for this study, is a method of pouring mortar into the ground by non-emission replacement principle, which can be expected to increase the density of the ground, and, in some cases, be used as a base file using the strength of the high injection solids, along with low noise, low pollution, and high durability. To verify that the dynamic characteristics of the ground are improved by the low-flow injection technique, the test work was conducted on the site and physical tests were performed, and the quality of the improvement formed in the ground was verified through the indoor test on the core and core recovery rate was analyzed. The density logs test layer calculated the volume density of the ground layer by using the Compton scattering of gamma-rays, and the sonic logs was tested on the ground around the drill hole using a detector consisting of sonar and receiver devices inside the drill hole. As a result of the measurement of the change in physical properties (density and sonic logs) before and after grouting, both properties were basically increased after infusion of grout agent. However, the variation in density increase was greater than the increase in speed after grouting, and the ground density measurement method was thought to be effective in measuring the fill effect of the filler. Strength and core recovery rates were measured from specimens taken after the age of 28 days, and the results of the test results of the diffusion and strength test of the improved products were verified to satisfy the design criteria, thereby satisfying the seismic performance reinforcement.