• Title/Summary/Keyword: 압력 관

Search Result 1,035, Processing Time 0.027 seconds

A Study on ODSCC of OPR 1000 Steam Generator Tube (OPR 1000 증기발생기 전열관의 ODSCC 고찰)

  • Suk, Dong Hwa;Oh, Chang Ha;Lee, Jae Woog
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.16-19
    • /
    • 2010
  • In this study, the axial ODSCC occurrence of domestic OPR 1000 steam generator tube was caused by the tube weakness and the sludge accumulation in the secondary side of steam generator. Inconel 600 HTMA used as tube material is related to most of tube leakage accidents in the world and also these ODSCCs were detected mainly at the 5th TSP(Tube Support Plate) to the 8th TSP of hot leg side. These elevations(5th TSP to 8th TSP) pave the way for the sludge accumulation. As a result of EC(Eddy Current) Bobbin and RPC data analysis, ODSCCs were occurred at contact points of tube and tube support plate. The more accumulated sludge, the higher occurrence frequency of ODSCC.

  • PDF

Calculation of Electrical and Hydrodynamic Properties of Capillary Discharge (모세관 방전의 전기 및 유체역학적 특성 계산)

  • Kim, Seong-Ho;Kim, Jin-Sung;Lee, Young-Hyun;Yang, Kyung-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1548-1549
    • /
    • 2006
  • 모세관 방전은 내벽의 절연 물질이 용발되어 수만도 영역에서 고압의 플라즈마를 생성하는 장치로서 이로부터 분사된 플라즈마 제트는 추진제 점화나 신물질 제조 둥에 이용할 수 있다. 본 연구에서는 수십 $m{\Omega}$ 영역에서 수 ms에 걸쳐 수십 kA의 펄스 전류가 흐르는 모세관 방전에 대해 플라즈마의 온도 및 압력에 의해 결정되는 저항을 통하여 펄스 전원 회로를 해석하며, 이로부터 공급되는 오옴열에 의해 플라즈마의 온도, 압력 등이 결정되는 유체역학적 변화를 수치적으로 계산하였다. 이 결과는 용발에 의해 정상 상태에 도달하는 플라즈마의 특성을 잘 보여주고 있으며, 모세관 방전 실험의 전기적, 유체역학적 변수 예측에 유용하게 쓰일 수 있다.

  • PDF

A brief introduction to nozzle design in air jet loom (에어제트 직기의 노즐 설계기술)

  • 송동주;구본감
    • Journal of the KSME
    • /
    • v.35 no.1
    • /
    • pp.36-45
    • /
    • 1995
  • 주노즐내의 공기제트의 효율을 높이기 위해, 주노즐 제트 속도는 높을수록 높은 마찰력을 초래 하여 위사의 속도를 증가시킨다. 가속관의 길이가 증가하면 노즐출구에서의 공기의 속도와 난 류가 감소하며; 가속관의 직경이 증가할 때에는 공기속도가 감소하며 난류는 증가한다. 탱크압력, 가속관의 길이 등 유동조건에 따라 유동은 니들 끝과 가속관 출구에서 이중 초크(M=1)가 발 생할 수 있다. 에어가이드 직경과 노즐직경의 그 비율이 클수록 제트에 의한 유동의 비말동 반(entrainment)이 크게 된다. 실제 노즐직기내의 유동은 위사를 동반한 유동이므로 위와 같은 정성적인 설명에 위사의 물성치에 따른 고려를 반드시 하여야만 한다. 현장에서의 노즐설계는 노즐형상 자체의 영향은 물론 각종 위사의 물성치에 맞는 압축공기 압력 최적조건이 무엇인가를 찾는 일도 매우 중요하다.

  • PDF

A Study for Lifetime Predition of Expansion Joint Using HILS (HILS 기법을 적용한 신축관 이음 수명예측에 관한 연구)

  • Oh, Jung-Soo;Cho, Sueng-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.138-142
    • /
    • 2018
  • This study used HILS to test an expansion joint, which is vulnerable to the water hammer effect. The operation data for the HIL simulator was the length rate of the expansion joint by the water hammer, which was used for life prediction based on the vibration durability. For the vibration durability test, the internal pressure of the expansion joint was assumed to be a factor of the durability life, and the lifetime prediction model equation was obtained by curve fitting the lifetime data at each pressure. During the test, the major failure modes of crack and water leakage occurred on the surface of the bellows part. The lifetime prediction model typically follows an inverse power law model. The pressure is a stress factor, and the model is effective in only a specific environment. Therefore, another stress factor such as temperature will be added and considered for a mixed lifetime prediction model in the future.

A Study on the igniter using resonance tube (공명관을 이용한 점화기 연구)

  • Lee, Jung-Min;Kwon, Min-Chan;Shin, Dong-Sun;Semenov, V.V.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.10
    • /
    • pp.112-117
    • /
    • 2004
  • This work is on numerical and experimental studies on the new type igniter using aerodynamic energy. The aerodynamic igniter consists of a nozzle and a resonance tube. The supersonic jet from a nozzle coming into the resonance tube generates pressure oscillation between the nozzle and the resonator. This oscillation changes the kinetic energy to thermal energy in the resonator under a certain condition. In this study, sonic and supersonic nozzles were tested in two different resonators, results has been compared. And geometrical optimum values of a supersonic nozzle has been suggested to reduce aerodynamic loss and friction in the expanded surface of the nozzle.

Characteristics of Entrainment Flow Rate in a Coanda Nozzle with or without Coaxial Contractor (코안다 노즐에서 중심 축소관 유무에 따른 유입량 특성)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.21-27
    • /
    • 2014
  • A MILD(Moderate and Intense Low oxygen Dilution) combustion, which is effective in the reduction of NOx, is considerably affected by the recirculation flow rate of hot exhaust gas to the combustion furnace. The present study used a coanda nozzle for the exhaust gas recirculation in a MILD combustor. A numerical analysis was accomplished to elucidate the effect of exhaust gas entrainment toward the furnace with or without a coaxial contractor. The result of the present CFD analysis showed that the entrainment mass flow rate without a coaxial contractor had 18% larger than that with a coaxial contractor when the mixed gas outlet pressure was ambient pressure. On the other hand, if the outlet pressure increased, the mass flow rate with a contractor was larger than that without a contractor. It could be analysed by the entrainment driving force composed with the nozzle throat pressure, inlet and outlet pressures and flow cross sectional area.

Behavior of Underground Flexible Pipes Subject to Vehicle Load (ll)-Based on Field Tests- (차량하중을 받는 지중연성관의 거동특성 (ll)-실증실험을 중심으로-)

  • 이대수;상현규;김경열;홍성연
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.49-58
    • /
    • 2003
  • Underground flexible pipes for electric cables are subject to external loads and surrounding soil pressure. Particularly, strain of flexible pipes is of great concern in terms of safety and maintenance for electric cables. In this paper, stress and strain of flexible pipes with various installation depth are compared using traditional formula, FEM analysis, model soil box test and field test. from the findings of various analyses, considering the strain criteria-maximum 3.5%, it is suggested that flexible pipes can be buried at the depth of 80cm without additional soil improvement.

Investigation on Design Requirements of Vent Lines for Sodium-Water Reaction Pressure Relief System of Prototype Generation-IV Sodium-Cooled Fast Reactor (소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 배출배관 설계요건 연구)

  • Park, Sun Hee;Han, Ji-Woong
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.388-403
    • /
    • 2018
  • We investigated design requirements of vent lines for Sodium-Water Reaction Pressure Relief System of Prototype Generation-IV Sodium-Cooled Fast Reactor. We developed design requirements of areas of the rupture disks of the steam generator, a diameter of the gas vent line of the sodium dump tank, a diameter of the gas vent line of the water dump tank, a diameter of the water dump line of the steam generator. With the design requirements, we calculated the time to vent fluid inside the steam generator and analyzed the transient pressure behavior, also evaluated the close pressure value of the isolation valve of the water dump line. Our results are expected to be used as basis information to design Sodium-Water Reaction Pressure Relief System of Prototype Generation IV Sodium-Cooled Fast Reactor.

Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger (슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출)

  • Cho, Sung-Chul;Kim, Chang-Duk;Kim, Chang-Eob;Kwon, Jeong-Tae;Lim, Hyo-Jae
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.149-154
    • /
    • 2007
  • An experimental study on the air-side pressure drop of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side pressure drop in the literature is not based on a consistent approach. This paper focuses on method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface pressure drop estimation in fin-tube heat exchanger. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the air-side pressure drop on design conditions of condenser and evaporator. Results are pre-sented as plots of friction f-factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of $150{\sim}250\;kg/m^2s$ with air flows at velocity ranges from 0.38 m/s to 1.6 m/s.