• Title/Summary/Keyword: 압력파형

Search Result 98, Processing Time 0.022 seconds

Application of a Potential-Based Panel Method for Analysis of a 2-Dimensional Cavitating Hydrofoils Advancing Beneath a Free-Surface (자유수면 아래서 유한 Froude 수로 전진하는 2차원 수중익의 부분 및 초월 공동 유동 문제 해석)

  • J.M. Lew;C.S. Lee;Y.G. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.112-122
    • /
    • 1993
  • A potential-based panel method is presented for the analysis of a partially or supercavitating two-dimensional hydrofoil at a finite submergence beneath a free surface, treating without approximation the effects of the finite Froude number and the hydrostatic pressure. Free surface sources and normal dipoles are distributed on the foil and cavity surfaces, their strength being determined by satisfying the kinematic and dynamic boundary conditions on the foil-cavity boundary. The cavity surface is determined iteratively as a part of the solution. Numerical results show that the wave profile is altered significantly due to the presence of the cavity. The buoyancy effect due to the hydrostatic pressure, which has usually been neglected in most of the cavitating flow analysis, is found playing an important role, especially for the supercavitating hydrofoil; the gravity field increases the cavity size in shallow submergence, but decreases it when deeply submerged, while the lift reduces at all submergence depth.

  • PDF

AE Characteristic of Polyethylene Pipe under various defects (다양한 결함에 대한 폴리에틸렌 배관의 음향방출 특성)

  • Nam Ki Woo;Lee Si Yoon;Ahn Seok Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.1-7
    • /
    • 2004
  • The polyethylene pipe can use semi-permanent because of the high corrosion resistance with chemical stability. In addition to, there is the merit that is an easy to establish and to maintain. However, as the reason that it is simply degraded when the polyethylene pipe was exposed to the outside, mainly it is used to lay under the ground with low-pressure gas transportation pipe. In this study, the nondestructive evaluation method was used to maintain the integrity of the polyethylene pipe. We simulated the various defects on the polyethylene pipes, and then the AE signal occurred according to the impact test of steel ball was evaluated by the acoustic emission method. From the results, the waveform and dominant frequency could be distinguishing from the defect shapes of polyethylene pipe. Especially, in the case of notch defect, the AE signals occur different by the angle and depth of the notch.

  • PDF

A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment (심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구)

  • Choi, Wonsuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.51-56
    • /
    • 2021
  • The brachial systolic blood pressure and pulse pressure are the predictors of cardiovascular disease in individuals over 50 years of age. As the stiffness increases, the reflex amplitude and pressure in the late systole increase, resulting in an increase in left ventricular load and myocardial oxygen demand. Therefore, it is necessary to study how stiffness affects blood pressure. In this study, the blood pressure pulse waves were measured before and after taking the drug, and the blood pressure pulse wave was measured before and after myocardial heart transplantation in patients with heart failure. The correlation between R, L, and C components of the Windkessel model was estimated by increasing blood pressure. As a result of modeling the parameters of the Windkessel model using the curve fitting method, the increase in blood pressure and decrease in systolic rise time were due to the increase in the L component in the RLC Windkessel model. Among the various mechanical characteristics of blood vessels, the most important parameter affecting high BP waveform is the inertance.

A Study on the characteristic analysis and optimization according to Ballast design of Induction Lamp (고출력 무전극램프의 점등회로 설계를 통한 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Park, Dae-Hee;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we implemented for the development of a high output induction lamp system, which lamp design is optimized by gas type, mixing ratio, pressure and discharge tube size, amalgam type and mixing ratio, and characteristics of ferrite core in the lamp. It's the circuit design by improving the power factor and efficiency according to the driving method, which has analyzing the characteristics according to the waveform and frequency. Finally, luminaries design part for applying the optimal lighting system considering the surrounding environment, the characteristics of the lighting circuit for electrodeless lamp has analyzed and the improvement has been proceeded. In conclusion, the driving frequency has optimized at 135kHz with degrading $7{\sim}10^{\circ}C$ based on the results of the optical characteristics of the induction lamp on peak noise FET(Q3,Q4) damage.

Comparison of the Dehumidification Performance Between LiCl and LiBr in a Liquid Desiccant Dehumidifying Element Having Criss-Cross Sinusoidal Channels (Celdek) (교차 적층된 파형 액체 제습 소자 (Celdek)에서 LiCl과 LiBr 수용액의 제습 성능 비교)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.27-34
    • /
    • 2018
  • Recently, liquid desiccant systems have received attention for the dehumidification of air. LiCl and LiBr are widely used in liquid desiccant systems due to their excellent thermo-physical properties. In this study, dehumidification tests were conducted with Celdek elements using LiCl and LiBr. During the tests, the dry and wet-bulb air temperatures were maintained at $35^{\circ}C$ and $28^{\circ}C$, respectively. The solution temperature was $20^{\circ}C$, the solution concentration was 50%, the solution circulation rate was 50 kg/h, and the frontal air velocity was varied from 2.0 to 4.0 m/s. The results show that the amount of dehumidification increased as the frontal velocity increased. On average, LiCl showed 27% higher dehumidification performance than LiBr, which was probably due to the lower saturation of the absolute humidity of LiCl compared with that of LiBr. On the other hand, LiBr yielded 12% larger pressure drop than LiCl. In general, the Sherwood numbers of LiCl and LiBr were approximately the same, showing that the effect of the desiccant on the Sherwood number was insignificant. Existing correlations highly overpredicted the present Sherwood numbers.

Experimental and Numerical Studies on Application of Industrial Explosives to Explosive Welding, Explosive Forming, Shock Powder Consolidation (산업용 폭약을 이용한 폭발용접, 폭발성형과 충격분말고화에 관한 실험 및 수치해석적 연구)

  • Kim, Young-Kook;Kang, Seong-Seung;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.22 no.1
    • /
    • pp.69-76
    • /
    • 2012
  • Theoretical backgrounds on the experimental methods of explosive welding, explosive forming and shock consolidation of powders are introduced. Explosive welding experiments of titanium (Ti) and stainless steel (SUS 304) plate were carried out. It was revealed that a series of waves of metal jet are generated in the contact surface between both materials; and that the optimal collision velocity and collision angle is about 2,100~2,800 m/s and $15{\sim}20^{\circ}$, respectively. Also, explosive forming experiments of Al plate were performed and compared to a conventional press forming method. The results confirmed that the shock-loaded Al plate has a larger curvature deformation than those made using conventional press forming. For shock consolidation of powders, the propagation behaviors of a detonation wave and underwater shock wave generated by explosion of an explosive are investigated by means of numerical calculation. The results revealed that the generation and convergence of reflected waves occur at the wall and center position of water column, and also the peak pressure of the converged reflected waves was 20 GPa which exceeds the detonation pressure. As results from the consolidation experiments of metal/ceramic powders ($Fe_{11.2}La_2O_3Co_{0.7}Si_{1.1}$), shock-consolidated $Fe_{11.2}La_2O_3Co_{0.7}Si_{1.1}$ bulk without cracks was successfully obtained by adapting the suggested water container and strong bonding between powder particles was confirmed through microscopic observations.

Fabrication of the Plasma Focus Device for Advanced Lithography Light Source and Its Electro Optical Characteristics in Argon Arc Plasma (차세대 리소그래피 빛샘 발생을 위한 플라스마 집속 장치의 제작과 아르곤 아크 플라스마의 발생에 따른 회로 분석 및 전기 광학적 특성 연구)

  • Lee S.B.;Moon M.W.;Oh P.Y.;Song K.B.;Lim J.E.;Hong Y.J.;Yi W.J.;Choi E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.380-386
    • /
    • 2006
  • In this study, we had designed and fabricated the plasma focus device which can generate the light source for EUV(Extreme Ultra Violet) lithography. And we also have investigated the basic electrical characteristics of currents, voltages, resistance and inductance of this system. Voltage and current signals were measured by C-dot and B-dot probe, respectively. We applied various voltages of 1.5, 2, 2.5 and 3 kV to the anode electrode and observed voltages and current signals in accordance with various Ar pressures of 1 mTorr to 100 Torr in diode chamber. It is observed that the peak values of voltage and current signals were measured at 300 mTorr, where the inductance and impedance were also estimated to be 73 nH and $35 m{\Omega}$ respectively. The electron temperature has been shown to be 13000 K at the diode voltage of 2.5 kV and this gas pressure of 300 mTorr. It is also found that the ion density Ni and ionization rate 0 have been shown to be $N_i = 8.25{\times}10^{15}/cc$ and ${\delta}$= 77.8%, respectively by optical emission spectroscopy from assumption of local thermodynamic equilibrium(LTE) plasma.

Accuracy Evaluation of Respiratory Air Flow Transducer for Artificial Ventilation (인공호흡시 호흡기류 계측 센서의 정확도 평가)

  • Lee, In-Kwang;Park, Mi-Jung;Kim, Kyoung-Ok;Shin, Eun-Young;Shon, Ho-Sun;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.425-431
    • /
    • 2015
  • Measurement accuracy was evaluated for the respiratory air flow transducer developed for applications under emergent situations. Pressure-Flow calibration equation was obtained by acquisition of air flow signals from the transducer in response to 6 flow waveforms, similar to those of artificial ventilation, generated by the standard flow generator system. Tidal volume and maximal flow rate were calculated on the flow signal then compared with the error-free data obtained by the linear displacement transducer of the flow generator system. Mean relative error of the tidal volume was within 3% and that of the maximal flow rate, approximately 5%, demonstrating accurate enough measurements. Therefore, the transducer could be applied to emergent situations to monitor the respiratory air flow signal as well as diagnostic parameters in real time.