• Title/Summary/Keyword: 압력수두

Search Result 78, Processing Time 0.031 seconds

An Analysis of Attenuation Effect of Pressure Head Using an Air Chamber (공기실을 사용한 압력수두의 완화효과에 대한 분석)

  • Lee, Jae-Su;Yun, Yong-Nam;Kim, Jung-Hun
    • Water for future
    • /
    • v.28 no.5
    • /
    • pp.141-150
    • /
    • 1995
  • An air chamber is designed to keep the pressure from exceeding a predetermined value, or to prevent low pressures and column separation. Therefore, it can be used to protect against rapid transients in a pipe system following abrupt pump stoppage. In this research, an air chamber was applied to a hypothetical pipe system to analyze attenuation effect of pressure head for different air volumes, locations, chamber areas, coefficients of orifice loss and polytropic exponents. With an increase of air volume, the maximum pressure head at pump site is decreased and the minimum pressure head is increased. For different locations and areas of the chamber, the attenuation effects do not show much difference. Also, as the orifice loss coefficient increases, the maximum pressure head is decreased. For different polytropic exponents, isothermal process shows lower maximum pressure head than that of the adiabatic process.

  • PDF

확산능을 이용한 지하 LPG 저장기지의 W/C 효율성 진단

  • 한일영;정일문;유홍정
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.31-34
    • /
    • 2001
  • 지하 LPG 저장기지의 수벽시설이 저장공동 주변 암반에 미치는 영향을 진단하기 위해서 수벽시설의 주입압력을 강하시키면서 간극수압계와 관측공에서의 지하수두 변화를 모니터링하였다. 수벽시설의 관측지점에 대한 효율성은 수치해석으로부터 수벽시설과 관측지점간 매질의 확산능을 구함으로써 분석하였다. 확산능 산출결과를 검증하기 위해서 수벽시설의 압력강하에 따른 관측지점에서의 수두강하비와 수두강하율을 구하여 확산능 결과와 비교하였다. 비교결과, 확산능은 수두강하비, 수두강하율과 일관된 변화를 보여주었으며 확산능의 값이 클수록 수벽공의 압력변화에 따른 관측지점에서의 반응성이 양호함을 나타내었다

  • PDF

Hydrodynamic Behavior Analysis of Flow over Ogee-Spillway by Using CFD Model (CFD 모형을 이용한 여수로 월류흐름의 동수역학적 거동 해석)

  • Kim, Dae Geun;Park, Jae Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.453-457
    • /
    • 2004
  • 본 연구에서는 WES의 표준 월류형 여수로에 대한 동수역학적인 흐름거동을 FLOW-3D 모형을 이용하여 해석하였다. 월류수두에 따른 월류유량, 월류흐름의 수면곡선, 여수로 표면에서의 압력분포와 같은 모의결과는 WES의 실험자료와 잘 일치하였다. 그리고 월류수두가 여수로 설계수두의 1.33배인 경우의 유속과 압력의 연직분포를 검토하였다. 검토결과, 웨어마루를 통과하면서 저층의 유속이 먼저 가속되며 점차 하류로 이동하면서 수표면의 유속이 가속되어 거의 균일한 유속분포를 보였으며, 압력의 연직분포는 웨어마루 상류에서는 수표면에서 내기압을 보이고 점차 수심이 길어짐에 따라 정수압분포와 유사한 분포를 보이나, 여수로 표면에 접근함에 따라 급격하게 압력이 감소하면서 부압이 발생하였다. 웨어마루 하류에서는 여수로 표면에서의 압력이 점차 대기압으로 접근함에 따라, 거의 전 수심에 걸쳐 대기압과 유사한 분포를 보였다.

  • PDF

Development of Shunt Valves Used to Treat Patients with Hydrocephalus (수두층 환자의 치료에 사용되는 션트밸브의 개발)

  • 이종선;김용환;장종윤;서창민;양근수;손창현;나영신;나영수
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.413-418
    • /
    • 2001
  • We developed shunt valves used to treat patients with hydrocephalus. The valves under development were constant Pressure type ventriculoperitoneal (VP) calves made of silicone elastomer. In vitro experiments showed that our valves had similar Pressure-flow control characteristics to the valved currently available in the market. Our valves also showed competent performance in the 28 days of continuous pumping tests acording to the IS07197 specifications. We artificially inducted hydrocephalus to a 10kg beagle do9. The size of the ventricles of the dog was substantially increased and the dog showed abnormal behavior. After our valve being implanted, the ventricles recovered regular size with the normal behavior observed in the dog. The flow orifice of the shunt valve diaphragm was in the older of 10$\mu$m during calve operation and hence the pressure-flow control characteristics tended to change by a small chance in the valve dimension. Therefore, precision design and manufacturing techniques were necessary for successful operations of the shunt valves .

  • PDF

Damage estimations of the real water distribution system based on reliability analysis (신뢰성해석을 통한 실제 상수도관망의 피해 분석)

  • Kwon, Hyuk Jae;Kim, Hyeong Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.290-290
    • /
    • 2018
  • 본 연구에서는 수충격으로 발생할 수 있는 실제 상수도관망의 피해율을 신뢰성해석을 통해 정량적으로 비교분석하였다. 이를 위해서 먼저 실제 상수관망에 대한 수충격해석을 수행하였는데 기존의 가압장 운영조건을 적용하였고 가압장의 선택운영조건을 변경하여 수충격해석을 수행하였다. 이 결과물을 토대로 신뢰성해석을 수행하였고 두 조건에 대하여 정량적인 파괴확률을 산정할 수 있었다. 본 연구에서 사용된 실제 상수관망은 가압장의 운영조건으로 24시간 75m 수두를 유지하고 있으며 관말단부의 수용가에 충분한 유량이 전달되고 있다. 가압장의 고압유지는 관말부에는 적정할 수 있으나 상수도관망에서 누수와 시설물에 대한 많은 피해를 유발할 수 있다. 따라서 본 연구에서는 가압장의 펌프압력수두를 75m와 65m로 선택적 운영을 가정하였다. 이로 인한 관말부의 압력이 수도압력으로 충분한 15m를 계속 유지하는 것을 확인하였으며 수돗물 사용량이 적은 야간에는 가압장의 수두를 낮추는 방법으로 선택적 운영조건을 사용하였다. 기존 가압장의 운영조건과 선택적 운영조건을 사용하여 수충격해석을 수행하였고 신뢰성 해석모형을 사용하여 파괴확률을 정량적으로 산정할 수 있었다. 가압장의 운영조건을 최적화하여 효율은 증대하고 피해율을 저감할 수 있는 방법을 찾을 수 있었다, 이를 위해서 가압장의 인버터 설치는 물론이고 펌프의 최적운영을 위한 프로그램을 장착하여 가압장을 운영한다면 보다 경제적인 운영이 될 수 있을 뿐만 아니라 실제 상수관망에서 발생할 수 있는 여러 가지 피해를 최소화할 수 있을 것으로 판단된다.

  • PDF

Implementation of Infinite Boundary Condition Considering Superposed Theory on SVE Remediation System (토양증기추출복원 시스템에서 중첩이론을 고려한 무한 경계조건 실행)

  • Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.3
    • /
    • pp.9-16
    • /
    • 2007
  • Soil vapor extraction (SVE) is an effective and cost efficient method of removing volatile organic compounds (VOCs) and petroleum hydrocarbons from unsaturated soils. Incorporating PVDs in an SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. With this approach, the real bounded system is replaced for the purposes of analysis by an imaginary system of infinite areal extent. The boundary conditions for the contaminant remediation model test include constant head and no flow condition. Due to these parallel boundaries conditions, image wells should be developed in order to maintain the condition of no flow across the impermeable boundary. It is also assumed that the flow is drawdown along the constant head boundary condition. The factors contributing to the difference between the theoretical and measured pressure heads were also analyzed. The flow factor increases as the flow rate is increased. The flow rate is the most important factor that affects the difference between the measured and theoretical pressure heads.

  • PDF

Changes in The Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation (뇌압 펄스에 의한 션트밸브의 압력-유량제어 특성의 변화)

  • 홍이송;이종선;장종윤
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.391-395
    • /
    • 2002
  • Shunt valves used to treat patient with hydrocephalus were numerically simulated to investigate influence of pressure pulsation on their flow control characteristics. We modeled flow orifice through the shunt valve and imposed pulsating pressure and valve diaphragm movement to compute flow through the valve. The results of our study indicated that flow rates increased more than 40% by introducing pressure pulsation and diaphragm movement on the shunt valve. Our results demonstrate the pressure-flow control characteristics of shunt valves implanted above human brain may be quite different from those obtained by syringe pump test just after manufacture that induces uniform pressure.

Pool Boiling Characteristics on the Microstructured surfaces with Both Rectangular Cavities and Channels (사각 공동 및 채널이 형성된 마이크로 구조 표면에서의 수조비등 특성연구)

  • Kim, Dong Eok;Park, Su Cheong;Yu, Dong In;Kim, Moo Hwan;Ahn, Ho Seon;Myung, Byung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.383-389
    • /
    • 2016
  • Based on a surface design with rectangular cavities and channels, we investigated the effects of gravity and capillary pressure on pool-boiling Critical Heat Flux (CHF). The microcavity structures could prevent liquid flow by the capillary pressure effect. In addition, the microchannel structures contributed to induce one-dimensional liquid flow on the boiling surface. The relationship between the CHF and capillary flow was clearly established. The driving potentials for the liquid supply into a boiling surface can be generated by the gravitational head and capillary pressure. Through an analysis of pool boiling and visualization data, we reveal that the liquid supplement to maintain the nucleate boiling condition on a boiling surface is closely related to the gravitational pressure head and capillary pressure effect.

Development and Its Applications of K-NRisk for Hydraulic Analysis of Water Supply System under Abnormal Conditions (비정상상황 관망 수리해석 SW K-NRisk 개발 및 적용)

  • Noh, Joon Woo;Yoo, Do Guen;Shin, Eun Her;Lee, Ho Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.271-271
    • /
    • 2017
  • 상수관망 수리해석 기법은 절점의 사용량 및 누수량을 기지의 값으로 고려하여 총 수요량이 모두 공급될 수 있다고 가정하여 해석하는 수요기반해석(Demand Driven Analysis, DDA)과 사용량과 누수량은 절점 압력수두에 의해 달라질 수 있어, 공급가능량 및 누수량과 절점의 압력수두 모두를 미지수로 고려하여 해석하는 수압기반해석(Pressure Driven Analysis, PDA)으로 구분될 수 있다. 본 연구에서는 수압기반사용량 모의(Pressure Dependent Demand, PDD)와 수압기반누수량 모의(Pressure Dependent Leakage, PDL)기능이 모두 구현되고, 다양한 시나리오 분석이 가능한 소프트웨어(SW)인 K-NRisk를 개발하였다. K-NRisk는 2016년 7월에 공개된 상수관망 해석범용모형인 EPANET3 소스코드 기반으로 개량 개발되었으며, 기존 EPANET2와 비교하였을 경우 사용자 편의성 증대를 위한 입출력 기능 및 SW 활용도 제고를 위한 대표업무분석 기능이 신규 개발, 강화되었다. 개발된 SW를 관망정비 및 공급안정성 확보 목적을 위한 수리해석 시 적용하여 그 결과를 분석하였다. 적용결과 기존 수요기반해석이 가지고 있는 한계점을 보완하고, 실제업무 시 활용가능함을 확인하였다.

  • PDF

Numerical Simulation of The Pressure-Flow Control Characteristics of Shunt Valves Used to Treat Patients with Hydrocephalus (수두층 치료용 션트밸브의 압력-유량 제어특성 수치해석)

  • 장종윤;이종선;서창민
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.403-412
    • /
    • 2001
  • The Present study analyzed the pressure-flow characteristics of a Korean shunt valve. Changes in the characteristic currie depending on the design parameters were also investigated. The Korean shunt valve used in the present study was constant pressure type and our analyses were validated through experiments. We applied fluid-structure interaction to solve the flow dynamic Problem because the small diaphragm in the valve was made from flexible silicone elastomers. Considering the material nonlinearity of the hyper-elastic material. the Mooney-Rivlin approximation was employed. The results of the numerical analyses were close to the experimental results The major Pressure drop was observed to happen in the small diaphragm. The slope of the pressure-flow characteristic curve was computed to be 0.37mm$H_2O$.hr/cc, which was similar to the average value of commercial shunt valves. 0.40mm$H_2O$.hr/cc. Therefore. our valves analyzed in the Present study showed a Proper Pressure control characteristics of the constant pressure type shunt valves. The opening pressure could be controlled by adjusting the amount of predeflection of the valve diaphragm. In order to obtain opening pressures of 25mm$H_2O$ and 80mm$H_2O$, respectively, and the required predeflection was found to be 10.2$\mu$m and 35.3$\mu$m. The flow orifice size was found to be within 10$\mu$m during valve operation Therefore, Precision design and manufacturing techniques are necessary for successful operations of the shunt valve. The study indicated the amount of predeflection as well as the magnitude of corner rounding of the diaphragm edge are important design parameters to influence the slope of the pressure-flow characteristic curve.

  • PDF