• Title/Summary/Keyword: 압력변화 주기

Search Result 108, Processing Time 0.021 seconds

Response of Ultrafiltration Flux to Periodic Oscillations in Transmembrane Pressure Gradient (압력구배의 주기적 변화에 따른 한외여과 Flux의 변화)

  • 서창우;이은규
    • KSBB Journal
    • /
    • v.14 no.2
    • /
    • pp.230-234
    • /
    • 1999
  • To improve the crossflow untrafiltration flux, we applied periodic oscillations in transmembrane pressure gradient in order to promote fluid turbulence by inducing repeated compression and relaxation of the cake/gel layer. The oscillatory forms used were square-, sine-, triangle-wave, and pumping interruption. The permeate flux profiles were mathematically simulated and compared with the experimental data. The result showed the periodic pumping interruption most effectively improved the overall flux by up to about 32%. Enough pumping off-time, at least on the order of tens of seconds, was needed to allow the solutes in the layer to diffuse back to the bulk phase. It was better to start the oscillations earlier before the layer was fully established. The square-wave oscillation yielded about 11% increase, which was particularly pronounced in the later part of the filtration. Either the amplitude or the period of the oscillations resulted little influence on flux.actate ester, and lactate ester produced in esterification reaction was distilled simultaneously with hydrolysis reaction into lactic acid. When the yields of lactic acid recovered by batch reactive distillations with various alcohols were compared, the yield of lactic acid was increased as the volatility of lactate ester was increased. In this batch reactive distillation, because the mixtures condensed in partial condensor were flown to reboiler through distillation column, the recovery yield of lactic acid was affected by operation temperature of partial condensor. Hydrolysis reaction into lactic acid in distillation column rarelyoccurred because of short retention time of lactate ester and water. Lactate ester was reacted into lactic acid in reboiler.

  • PDF

HID 램프용 전자식 안정기 회로 및 특성 이해

  • 김기정
    • Electric Engineers Magazine
    • /
    • v.230 no.10
    • /
    • pp.30-33
    • /
    • 2001
  • 음향공명 발생원인 가스가 들어있는 방전관내에 방전전류가 흐르면 전력에너지가 발생하여 열을 발생 시키고 이 열은 방전관내의 압력변화를 가져온다. 이 압력변화는 방전관내의 음향변화와 같다. 주기적인 압력변화가 내벽에 반사되어 정재파가 발생되는 현상이 방정관의 고유진동수이며 이 고유진동수와 전원주파수가 일치될 때 음향공명현상이 일어난다.

  • PDF

Pain Threshold & Taste Threshold Variations across the Menstrual Cycle (월경주기에 따른 동통역치 및 미각역치의 변화)

  • Byun, Young-Hee;Koo, Sun-Ju;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.3
    • /
    • pp.253-260
    • /
    • 2001
  • 이 연구의 목적은 월경주기에 따른 동통역치와 미각역치의 변화를 평가하고자 하는 것이다. 안면부에 동통성 질환이 없고 정상 월경 주기를 가진 건강한 20대 여성 11명이 이 연구에 참여하였다. 2회의 연속적인 월경주기 동안, 월경기(menstrual phase), 여포기(follicular phase), 황체기(luteal phase)의 세 시기에서 압력통각역치, 전기미각역치, NaCl 미각역치를 각각 측정하였다. 각 역치를 월경주기의 시기별로 비교 분석하여 다음과 같은 결과를 얻었다. 압력통각역치와 전기미각역치는 월경주기의 시기에 따라 유의한 차이를 나타내었고, 황체기에서 월경기에서와 비교하여 통계적으로 유의하게 높은 역치를 나타내었다. NaCl 미각역치는 월경주기에서 통계적으로 유의한 변화를 나타내지 않았다.

  • PDF

Waterhammering on Pump Pipeline Systems (펌프 관로계의 수격현상)

  • 김경엽;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.331-355
    • /
    • 1997
  • 본 연구에서는 에어챔버가 설치된 펌프관로계에서 수격현상에 대한 현장실험을 실시하고, 에어챔버의 입력변수 및 설계인자가 수격현상에 어떠한 영향을 미치는지 수치계산과 실험을 통하여 조사한 후 다음과 같은 결론을 얻었다. (1) 수치계산에 사용된 입력변수중 폴리트로프지수, 오리피스 유량계수, 압력파 전파속도순으로 수격현상에 대한 영향이 크게 나타났으며, 수치계산은 이 변수값이 각각 1.3, 0.7, 1,050m/s일 때 측정된 압력변동 및 공기체적변화를 가장 잘 모사하였다. (2) 에어챔버내 초기공기체적이 증가하면 압축공기의 압력변화율이 작아지기 때문에 수격현상의 주기는 길어지고, 관로내 압력변화는 감소하였다. 측관에 설치한 오리피스 내경을 줄임으로써 상승압은 상당히 완화되었으며, 시간이 지남에 따라 수격작용도 보다 빨리 감쇄되었다. 수치계산결과는 수격현상의 1-2주기까지 측정값과 비교적 잘 일치하였으며, 펌프관로계에 작용하는 최대.최소압력 및 그 발생시간도 합리적으로 예측되었다. (3) 수치계산은 측정된 과도특성 값들을 약 5%이내의 오차로 예측하였으며, 개발된 전산프로그램은 실제 펌프관로계에 대한 수격완화장치를 설계하는데 매우 유용하게 사용될 것으로 판단된다.

  • PDF

Fabrication and characteristics of mechanically induced long-period fiber gratings (기계적으로 유도된 장주기 광섬유격차의 제작 및 특성분석)

  • 함정우;이종훈;이경식
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.485-488
    • /
    • 2001
  • The transmission spectra, the wavelength tunability. and the polarization characteristics of mechanically induced long-period fiber gratings (LPFG's) are investigated experimentally and analyzed theoretically. The transmission and mode coupling characteristics of the fabricated LPFG's agree well with the theoretical results. The resonant wavelengths at which the mode coupling occurs can be tuned over 180 nm and the peak wavelengths for of oethogonally polarized lights are split by -9 nm.

  • PDF

Contrivance of a Radial Pulse Measuring System with Variable Contact Pressure (압력 조절식 맥진 센서의 개발)

  • 윤영준;조정현;정현민;신학수;소광섭
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.567-572
    • /
    • 1999
  • 혈관내 맥검출 센서인 MPX2300DT1을 요골동맥상에서 무침습적으로 맥파를 검출할 수 있도록 실리콘 고무를 부착하여 맥진 센서로 활용하였다. 또한 추의 무게에 의해 압력을 조절하여 그것에 따른 맥파의 변화를 볼 수 있는 맥진 시스템을 제작하였다. 맥진 센서의 압력에 따른 출력전압의 선형성을 확인하였으며 추의 무게에 따른 맥파의 진폭과 주기 변화를 조사하였다.

  • PDF

Wavelength spacing tunable multi-wavelength Erbium-doped fiber ring laser (파장간격 가변형 다파장 어븀 첨가 광섬유 링 레이저)

  • Kim, Hwan;Jang, Hyun-Soo;Park, Kwang-No;Lee, Kyung-Shik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.55-60
    • /
    • 2008
  • Multi-wavelength Erbium-doped fiber(EDF) ring laser was developed by using a sampled fiber Bragg grating reflecting multiple wavelengths, which was formed by impressing periodical pressure on the outside of a fiber Bragg grating. The wavelength spacing was varied to 4.1nm, 1.41nm and 0.82nm, by pressing the grating with the pressure period $200{\mu}m$, $580{\mu}m$ and $1000{\mu}m$, respectively.

실제크기 배관 피로시험에 의한 손상배관의 수명평가

  • 김철만;백종현;김영표;김우식
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.05a
    • /
    • pp.403-406
    • /
    • 2002
  • 가정용 및 산업용으로 사용되고 있는 천연가스는 70kg/cm1의 압력으로 지하에 매설되어 있는 API 5L X65재질의 배관을 통하여 공급되고 있다 생산기지에서 공급되는 압력이 70kg1cmr이지만 가스소비량에 따라 계절별 및 월별 가스 내압이 변화되고 있다. 하루에도 최대 2회정도 주기적으로 변화를 보이고 있다. 본 연구에서는 API 5L X65등급의 가스배관 모재 및 용접부에 일정한 형태의 가우지 결함을 가공하여 현재 사용중인 내압 조건과 유사한 내압변화를 재현하여 피로수명을 평가하였다.(중략)

  • PDF

A Study on the Cyclic Pressure Function in Freeze Drying of Foodstuff (식품의 냉동 건조에서 주기 압력 함수에 대한 연구)

  • Mun, Jae-Choel;Kim, Soo-Ho;Hwang, Kap-Sung;Hong, Song-Sun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • We show that the usage of the cyclic pressure function in the freeze drying is more effective than the drying rate of the constant pressure process. The ultimate object of this process is to reduce energy costs by shortening the drying time. In this work, the concept of cyclic pressure function to decrease the drying time and the effects of the following factors on drying rate are considered ; pulse type, size in amplitude of pressure, size of intermediate time. Temperature for drying has always been maintained constantly at $20^{\circ}C$ and the pulse type could have found to give useful results than the constant pressure by altering chamber pressure from low pressure to high pressure Also, when the amplitude of the pulse is 0.4 torr and the intermediate time is six hour the drying rate was increased considerably.

  • PDF

Dynamic Characterization of Passive Flow-Rate Regulator Using Pressure-Dependent Autonomous Deflection of Parallel Membrane Valves (압력에 따른 평행박막 밸브의 자율 변형을 이용한 수동형 유량 제어기의 동적특성 평가)

  • Doh, Il;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.825-829
    • /
    • 2011
  • We performed a dynamic characterization of passive flow-rate regulators, which compensate for inlet pressure variation and maintain a constant flow rate for precise liquid control in microfluidic systems. To measure the flow rate for a short time, much less than the period of the dynamic inlet pressure, we use the particle image velocimetry (PIV) method. DI water containing fluorescent beads with a $0.7-{\mu}m$ diameter was supplied to the flow-rate regulators, and two successive images of the particles were taken by a pulse laser and a fluorescent microscope to measure the flow velocity. For a dynamic inlet pressure of frequency 60 Hz, the flow velocity was constant with an average of 0.194 ${\pm}$ 0.014 m/s as the inlet pressure varied between 20 kPa to 50 kPa. The flow-rate regulators provided a constant flow rate of $5.82{\pm}0.29\;{\mu}l/s$ in the frequency range of the inlet pressure from 1 Hz to 60 Hz.