• 제목/요약/키워드: 알루미늄 열교환기

검색결과 45건 처리시간 0.031초

가정용 공조기의 응축기 적용 알루미늄 열교환기의 성능 평가 (Performance evaluation of brazed aluminum heat exchangers for a condenser in residential air-conditioning applications)

  • 김만회;김권진
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.44-55
    • /
    • 1998
  • The evaluation of aluminum flat tube and louver fin heat exchangers for a condenser in residential air-conditioning applications has been conducted. A series of tests for two-different brazed aluminum heat exchangers was performed and the results were compared with conventional fin and tube heat exchangers for residential air-conditioning system. Refrigerant charge amount for a window-system air-conditioner with the brazed aluminum condenser is decreased by 35% and the volume and material of heat exchanger can be reduced by 50% compared to the conventional fin and tube heat exchangers.

  • PDF

배기열회수 알루미늄 열교환기의 공조시스템 적용에 관한 연구 (The Study on the Application of Heat Recovery Aluminium Heat Exchanger in HVAC System)

  • 박용효;김동규;김근오;정용환;금종수;정석권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1272-1276
    • /
    • 2009
  • The purpose of this study is to introduce wasted heat recovery heat exchanger for different kind of material in HVAC systems in field. For the purpose of estimating the large volume rotary heat exchanger and cross flow plate heat exchanger in heat recovery ventilator.

  • PDF

동관-알루미늄 휜 회전형 히트파이프 열교환기의 성능에 관한 연구 (A Study on the Performance of Rotary Heat Exchanger using Aluminum Finned Copper Tube Heat Pipe)

  • 박기호;이기우;이계중;전원표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.7-12
    • /
    • 2000
  • The purpose of this study is to develop heat transfer analysis program of heat pipe elements and design a revolving heat pipe exchanger by the performance experiment of hot air production by means of middle-temperature waste heat. Experimental variables are the revolution per minute, normal velocity of inlet air and the temperature of waste heat. The revolving heat exchanger has designed as $2^{\circ}$ in inclination angle of heat pipe bundle and as 20% in working fluid quantity and as water in working fluid. Experimental value of the total heat transfer coefficient was $20w/m^2-^{\circ}C$

  • PDF

공정변수에 따라 Al 합금 상에 형성된 PEO 코팅층의 내식성 평가 (Effects of Process Parameters on Corrosion Properties of PEO Coatings Formed on Al Alloy)

  • 이정형;김성종
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.139-139
    • /
    • 2018
  • 최근 자동차 산업을 중심으로 한 수송용 기기의 경량화 추세에 따라 대표적인 경량금속 소재인 알루미늄 합금에 대한 수요가 증가하고 있으며 이에 따라 알루미늄 합금 표면에 다양한 특성을 부여할 수 있는 표면개질 기술에 대한 필요성이 부각되고 있다. 알루미늄 합금의 대표적인 표면처리기술인 아노다이징과 유사한 원리로 표면에 세라믹 코팅층을 형성할 수 있는 기술인 플라즈마 전해 산화(Plasma electrolytic oxidation, PEO)가 주목을 받고 있다. PEO 코팅법은 전해액 내에 소재를 침지시키고 400 ~ 600V에 이르는 고전압을 인가시켜 마이크로 방전을 유도하여 표면에 치밀한 세라믹 층을 형성시키는 기술이다. 본 연구에서는 PEO법으로 표면 개질된 Al 합금 표면의 표면 조직 특성과 전기화학 특성을 평가하고, 코팅층 특성에 미치는 공정 변수의 영향을 분석하고자 하였다. PEO 처리를 위해 사용된 소재는 상용 Al 합금 판재(Al 5083-O)로서 $2cm{\times}2cm$로 절단하여, 에머리페이퍼로 1000번까지 연마하여 사용하였다. 시험을 위한 PEO 처리 시스템은 전해액 수조, 일정 온도 유지를 위한 열교환기와 칠러, 전원 발생을 위한 전원공급기(power supply)로 구성되었다. 전해액은 약 알칼리 수용액을 이용하였으며, 전원 공급기를 통해 시험편에 펄스 전류를 인가하였다. PEO 처리 후 시편에 대하여 SEM, EDS, XRD 등을 이용한 표면 특성 평가를 실시하였다. 또한 코팅층의 전기화학적 부식 특성 평가를 위해 해수용액에서 동전위분극실험을 실시하였다. 시험 결과, Al 합금의 PEO 처리 시 내식성은 개선되는 것으로 확인되었으며, 공정변수는 표면의 미세조직 및 전기화학적 특성에 큰 영향을 미치는 것으로 나타났다.

  • PDF

알루미늄 평행류 열교환기에서 냉매패스와 분배량 변화의 영향 (The Effect of refrigerant pass & distribution in aluminum parallel flow heat exchanger)

  • 김정식;김내현;김광희
    • 한국산학기술학회논문지
    • /
    • 제10권12호
    • /
    • pp.3546-3552
    • /
    • 2009
  • 본 연구에서는 천정 설치형 공조기 적용을 위해 연구가 활발히 진행되고 있는 알루미늄 평행류 증발기 해석 프로그램을 개발하여 190mm*650mm*25mm(W*H*D) 크기의 열교환기를 해석하였다. R410A냉매의 분배비가 일정하고 상하로 유동하는 2, 3 패스의 경우와 3 패스이고 분배비율(1:1:1, 1:2:2)을 달리할 때, 열교환 성능을 예측하였다. 계산 결과, 2 패스가 3 패스보다 국소 전열량이 30% 정도 높았지만, 건도에 따른 열전달계수는 25% 낮았으며, 3 패스의 경우, 분배비 1:1:1 보다 1:2:2가 냉매 압력손실이 높게 나타났다. 본 해석에서는 패스당 냉매가 균일하게 분포하는 것으로 가정하였으므로, 패스별로 불균일하게 유동되는 실제의 경우보다 열교환성능을 과대 예측하는 것으로 판단된다.

저속 영역에서 루버휜이 장착된 평판관형 알루미늄 열교환기의 공기측 전열 성능에 대한 실험적 연구 (Air-side Performance of Louver-Finned Flat Aluminum Heat Exchangers at a Low Velocity Region)

  • 조진표;오왕규;김내현;윤백
    • 대한기계학회논문집B
    • /
    • 제26권12호
    • /
    • pp.1681-1691
    • /
    • 2002
  • The heat transfer and pressure drop characteristics of heat exchangers with louver fins were experimentally investigated. The samples had small fin pitches (1.0 mm to 1.4 mm), and experiments were conducted up to a very low frontal air velocity (as low as 0.3 m/s). At a certain Reynolds number (critical Reynolds number), the flattening of the heat transfer coefficient curve was observed. The critical Reynolds number was insensitive to the louver angle, and decreased as the louver pitch to fin pitch ratio (L$_{p}$F$_{p}$) decreased. Existing correlations on the critical Reynolds number did not adequately predict the data. It is suggested that, for proper assessment of the heat transfer behavior, the louver pattern in addition to the flow characterization need to be considered. The heat transfer coefficient increased as the fin pitch decreased. At low Reynolds numbers, however, the trend was reversed. Possible explanation is provided considering the louver pattern between neighboring fins. Different from the heat transfer coefficient, the friction factor did not show the flattening characteristic. The reason may be attributed to the form drag by louvers, which offsets the decreased skin friction at a low Reynolds number. The friction factor increased as the fin pitch decreased and the louver angle increased. A new correlation predicted 92% of the heat transfer coefficient and 90% of the friction factor within $\pm$10%.10%.

경사각이 PF 열교환기의 열전달 및 압력 손실에 미치는 영향 (Effect of Inclination Angle on the Heat Transfer and Pressure Drop Characteristics of Parallel Flow Heat Exchanger)

  • 김도영;함정호;김내현;박내현;황준현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.222-228
    • /
    • 2007
  • The effect of inclination angle on the heat transfer and pressure drop characteristics of brazed aluminum heat exchangers is experimentally investigated. Three samples having different fin pitches (1.25, 1.5 and 2.0 mm) were tested. Results show that heat transfer coefficient is not affected by the inclination angle. However, the friction factor increases as the inclination angle increases with negligible difference between the forward and backward inclination. Both the heat transfer coefficient and the friction factor are the smallest at $P_f$=1.5mm, followed by $P_f$=2.0mm and 1.25mm. Possible explanation is provided considering the louver layout. Comparison with existing correlations is also mad.

  • PDF

공조용 알루미늄 납작관 내의 R-410A 대류 비등 (Convective Boiling of R-410A in an Aluminum Flat Tube for Air-Conditioning Application)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3006-3013
    • /
    • 2015
  • 원관 열교환기보다 납작관 열교환기를 사용하면 전열성능을 한층 향상시킬 수 있다. 납작관 열교환기를 적절히 설계하기 위해서는 관 내측 열전달계수를 알아야 한다. 본 실험에서는 수력직경 1.41mm인 알루미늄 납작관 내 R-410A 대류 비등 열전달계수를 구하였다. 실험범위는 질량유속 $200{\sim}600kg/m^2s$, 열유속 $5{\sim}15kg/m^2$, 포화온도 $5{\sim}15^{\circ}C$이다. 실험 결과 열전달계수는 임계 건도를 기점으로 감소함을 보였다. 임계 건도는 열유속이 증가할수록 감소하고, 질량유속이 감소할수록 감소하였다. 이는 높은 열유속 또는 낮은 질량유속에서 대류의 영향이 작게 되고 따라서 조기에 dryout이 발생되기 때문에 나타나는 현상으로 판단된다. 열전달계수는 질량유속이 증가할수록 증가하였다. 그러나 낮은 건도에서는 질량유속의 영향은 미미하였다. 열전달계수는 포화온도가 증가할수록 증가하였다. 하지만 이런 경향은 열유속이 작아지면 감소하였다. Shah와 Kaew-On et al. 상관식은 본 실험자료를 적절히 예측하였다.