• Title/Summary/Keyword: 알고리듬 개발

Search Result 616, Processing Time 0.02 seconds

A Mode Switching Protocol between RVOD and NVOD for Efficient VOD Services (효율적인 VOD 서비스를 위한 RVOD와 NVOD간의 전환 프로토콜)

  • Kim, Myoung-Hoon;Park, Ho-Hyun
    • The KIPS Transactions:PartA
    • /
    • v.15A no.4
    • /
    • pp.227-238
    • /
    • 2008
  • Recently, as network environment has broadened, the demands on VOD have been increased. The VOD services can be categorized into two types, RVOD and NVOD. Practical VOD services adopt one of them exclusively. Since a method using only one of RVOD and NVOD is not able to deal with frequently variable demand of clients, it leads to a result of overload on a server and a waste of server bandwidth. The efficiency of the network resource usage becomes lower. Hence this paper presents a study on the protocol for efficient VOD services. We propose a new protocol appliable for the existing VOD service algorithm, analyze its performance through simulation, and developed server/client systems applying the new protocol. We propose a mode switching protocol combined with protocols used in RVOD and NVOD. The proposed protocol is not able only to control both RVOD and NVOD but also to change the mode between RVOD and NVOD. As a result of using the proposed protocol to meet frequently variable demand, server bandwidth can be used efficiently. Especially, it can be applied to the existing VOD service algorithms. Therefore, we expect that the proposed protocol in this paper will be widely used in emerging VOD markets.

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing Cs-137 Source by a Computer (컴퓨터 의한 Fletcher-Suit Colpostat 주변의 Cs-137의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.305-311
    • /
    • 1989
  • Fletcher-Suit colpostat has an internal structure to reduce dose to bladder and rectum. Some programs were developed to calculate dose at any point in water in three dimension around the colpostat containing Cs-137 tube, to find the shielding effect to dose by the internal structure, and to draw isodose curves and iso-shielding effect curves. Computer was an IBM compatible AT with EGA card and language was MS-Basic V6.0, Material, shape and geometry of the strucure, tube and colpostat were considered in algorithm for calculation of dose. Dose rates per unit mg. Ra. eq. in water calculated by a program were stored in auxiliary memory devices and retrieved in another programs. Isodose curves on medial side shrinked. Dose distribution was not symmetric about a transverse axis bisecting the colpostat. Reduction of dose was more excessive on top side than on bottom. Iso-shielding effect curve showed that the shielding effect was higher on top side than on bottom, and that there was shielding effect over almost all area of medial side. Such results were related to both shifted position of tube in the colpostat and asymmetric distribution of active source in the tube. Maximum of shielding effect was $49\%$ on top side and $44\%$ on bottom side. The direction of iso-shielding effect curve was generally radial from the center of active source. In treatment planning using Fletcher-Suit colpostat, the internal structure should be considered to find precise doses to bladder and rectum, etc.

  • PDF

Automated Analysis for PDC-R Technique by Multiple Filtering (다중필터링에 의한 PDC-R 기법의 자동화 해석)

  • Joh, Sung-Ho;Rahman, Norinah Abd;Hassanul, Raja
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3C
    • /
    • pp.141-148
    • /
    • 2010
  • Electrical noises like self potential, burst noises and 60-Hz electrical noises are one of the causes to reduce reliability of electrical resistivity survey. Even the PDC-R (Pseudo DC resisitivity) technique, recently developed, is suffering from the problem of low reliability due to electrical noises. That is, both DC-based and AC-based resistivity technique is subject to reliability problem due to electrical noises embedded in urban geotechnical sites. In this research, a new technique to enhance reliability of the PDC-R technique by minimizing influence of electrical noises was proposed. In addition, an automated procedure was also proposed to facilitate data analysis and interpretation of PDC-R measurements. The proposed technique is composed of two steps: 1. to extract information only related with the input current by means of multiple-filter technique, and 2. to undertake a task to sort out signal information only to show stable and reliable characteristics. This automated procedure was verified by a synthetic harmonic wave including DC shift, burst random noises and 60-Hz electrical noises. Also the procedure was applied to site investigation at urban areas for proving its feasibility and accuracy.

K-DEV: A Borehole Deviation Logging Probe Applicable to Steel-cased Holes (철재 케이싱이 설치된 시추공에서도 적용가능한 공곡검층기 K-DEV)

  • Yoonho, Song;Yeonguk, Jo;Seungdo, Kim;Tae Jong, Lee;Myungsun, Kim;In-Hwa, Park;Heuisoon, Lee
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • We designed a borehole deviation survey tool applicable for steel-cased holes, K-DEV, and developed a prototype for a depth of 500 m aiming to development of own equipment required to secure deep subsurface characterization technologies. K-DEV is equipped with sensors that provide digital output with verified high performance; moreover, it is also compatible with logging winch systems used in Korea. The K-DEV prototype has a nonmagnetic stainless steel housing with an outer diameter of 48.3 mm, which has been tested in the laboratory for water resistance up to 20 MPa and for durability by running into a 1-km deep borehole. We confirmed the operational stability and data repeatability of the prototype by constantly logging up and down to the depth of 600 m. A high-precision micro-electro-mechanical system (MEMS) gyroscope was used for the K-DEV prototype as the gyro sensor, which is crucial for azimuth determination in cased holes. Additionally, we devised an accurate trajectory survey algorithm by employing Unscented Kalman filtering and data fusion for optimization. The borehole test with K-DEV and a commercial logging tool produced sufficiently similar results. Furthermore, the issue of error accumulation due to drift over time of the MEMS gyro was successfully overcome by compensating with stationary measurements for the same attitude at the wellhead before and after logging, as demonstrated by the nearly identical result to the open hole. We believe that the methodology of K-DEV development and operational stability, as well as the data reliability of the prototype, were confirmed through these test applications.

Comparing Prediction Uncertainty Analysis Techniques of SWAT Simulated Streamflow Applied to Chungju Dam Watershed (충주댐 유역의 유출량에 대한 SWAT 모형의 예측 불확실성 분석 기법 비교)

  • Joh, Hyung-Kyung;Park, Jong-Yoon;Jang, Cheol-Hee;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.9
    • /
    • pp.861-874
    • /
    • 2012
  • To fulfill applicability of Soil and Water Assessment Tool (SWAT) model, it is important that this model passes through a careful calibration and uncertainty analysis. In recent years, many researchers have come up with various uncertainty analysis techniques for SWAT model. To determine the differences and similarities of typical techniques, we applied three uncertainty analysis procedures to Chungju Dam watershed (6,581.1 $km^2$) of South Korea included in SWAT-Calibration Uncertainty Program (SWAT-CUP): Sequential Uncertainty FItting algorithm ver.2 (SUFI2), Generalized Likelihood Uncertainty Estimation (GLUE), Parameter Solution (ParaSol). As a result, there was no significant difference in the objective function values between SUFI2 and GLUE algorithms. However, ParaSol algorithm shows the worst objective functions, and considerable divergence was also showed in 95PPU bands with each other. The p-factor and r-factor appeared from 0.02 to 0.79 and 0.03 to 0.52 differences in streamflow respectively. In general, the ParaSol algorithm showed the lowest p-factor and r-factor, SUFI2 algorithm was the highest in the p-factor and r-factor. Therefore, in the SWAT model calibration and uncertainty analysis of the automatic methods, we suggest the calibration methods considering p-factor and r-factor. The p-factor means the percentage of observations covered by 95PPU (95 Percent Prediction Uncertainty) band, and r-factor is the average thickness of the 95PPU band.

A Preliminary Study on the Development of Korean Medication Algorithm for Attention-Deficit Hyperactivity Disorder (한국형 주의력결핍 과잉행동장애 약물치료 알고리듬 개발을 위한 예비연구)

  • Park, Jae-Hong;Kim, Bung-Nyun;Kim, Jae-Won;Kim, Ji-Hoon;Son, Jung-Woo;Shin, Dong-Won;Shin, Yun-Mi;Yang, Su-Jin;Yoo, Hanik-K.;Yoo, Hee-Jeong;Lee, Soyoung Irene;Cheon, Keun-Ah;Hong, Hyun-Ju;Hwang, Jun-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.22 no.1
    • /
    • pp.25-37
    • /
    • 2011
  • Objectives:This study was conducted to develop a Korean algorithm of pharmacological and non-pharmacological treatment strategies in attention-deficit hyperactivity disorder (ADHD) and its specific comorbid disorders (e.g. tic disorder, depressive disorder, anxiety disorder, bipolar disorder, and oppositional defiant disorder/conduct disorder). Methods:Based on a literature review and expert consensus, both paper- and web-based survey tools were developed with respect to a comprehensive range of questions. Most options were scored using a 9-point scale for rating the appropriateness of medical decisions. For the other options, the surveyed experts were asked to provide answers (e.g., duration of treatment, aver-age dosage) or check boxes to indicate their preferred answers. The survey was performed on-line in a self-administered manner. Ultimately, 49 Korean child & adolescent psychiatrists, who had been considered experts in the treatment of ADHD, vol untarily completed the questionnaire. In analyzing the responses to items rated using the 9-point scale, consensus on each option was defined as a non-random distribution of scores as determined by a chi-square test. We assigned a categorical rank (first line/preferred choice, second line/alternate choice, third line/usually inappropriate) to each option based on the 95% confidence interval around the mean rating score. Results:Specific medication strategies for key clinical situations in ADHD and its comorbid disorders were indicated and described. We organized the suggested algorithms of ADHD treatment mainly on the basis of the opinions of the Korean experts. The suggested algorithm was constructed according to the templates of the Texas Child & Adolescent medication algorithm Project (CMAP). Conclusion:We have proposed a Korean treatment algorithm for ADHD, both with and without comorbid disorders through expert consensus and a broad literature review. As the tools available for ADHD treatment evolve, this algorithm could be reorganized and modified as required to suit updated scientific and clinical research findings.