• Title/Summary/Keyword: 안정화 장치

Search Result 358, Processing Time 0.03 seconds

The Effect of 3-D Spine Stabilization Training on Trunk Muscle Strength and Body Composition in Elderly (3차원 척추 안정화 운동이 고령자의 체간 근력 및 신체구성에 미치는 효과)

  • Seo, S.B.;Kim, D.H.;Jung, H.C.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • This study was to verify effect on muscle strength of trunk and body composition for elderly according to spinal stability exercise with three dimension. We recruited forty elderly participants(twenties as training group, the other twenties as control group) over sixty five aged. The participant performed muscle strength estimation to exercise of eight direction using spinal stability training system. Also, we estimated body composition in participants using inbody 720. Trining group performed direction exercise(F, FOR, R, BOR, B, BOL, L, FOL) and multiple exercise with band exercise, strengthening gym and walking during thirty minute. But control group only performed multiple exercise without direction exercise. All training progressed three days a week for eight weeks. The results showed that muscle strength of trunk in training group increased significantly from 79.9 point to 85.6 point with reducement of body weight, body fat and BMI. However, control group showed a few exercise effect with increasement of amount of muscles and reducement of body fat without muscle strength of trunk. These results means that spinal stability exercise could be helped to prevent obey and fall of elderly caused by muscle strengthening and improving body composition. This could be applied to develop rehabilitation program efficiently based these data.

  • PDF

Electric power facility status and analysis of operation results for Korea Superconducting Tokamak Advanced Research (KSTAR 대전력 설비 현황 및 운전결과 분석)

  • Kong, Jong-Dae;Hong, Seong-Lok;Hwang, In-Seong;Kim, Yaung-Soo;Eom, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.85_86
    • /
    • 2009
  • 핵융합반응은 초고온의 플라즈마 상태에서 가벼운 원자핵들이 융합하여 무거운 원자핵으로 바뀌는 현상으로, 이 과정에서 감소된 질량이 막대한 에너지로 변환되는데 이를 핵융합에너지라고 한다. 핵융합에너지는 인류의 에너지 위기를 극복할 수 있는 최적의 대체에너지이며, 무한, 청정, 고효율에너지이다. 이에 국가핵융합연구소(NFRI)는 Green Energy 의 개발과 핵융합에너지 상용화 기술을 개발하기 위해 핵융합연구장치인 KSTAR(Korea Superconducting Tokamak Adavanced Research)를 제작하여 장치의 운전연구 및 기술 확보에 힘을 쏟고 있다. 또한 핵융합 관련 파생기술을 활용한 첨단 신사업 창출에 기여하고 있다. 본 논문에서는 KSTAR 1st Plasma 실험 시 KSTAR 장치에 전력을 공급하기 위한 전력설비 현황, 전력품질분석, 전력사용량 분석을 통해 향후 KSTAR 장치 운전을 위해 필요한 수전설비 증설, 무효전력보상장치 증설 등과 같은 전력계통의 효율화와 안정화를 위한 개선사항에 대해 기술하였다.

  • PDF

Development of the Simulation System for Testing and Evaluating of Traffic Signal Control Systems (교통신호제어시스템 성능평가 시뮬레이션 시스템 개발)

  • 정준하;하동익;이돈주
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.5
    • /
    • pp.71-83
    • /
    • 2001
  • This paper introduces the simulation system which was developed to evaluate the effectiveness of ITS, and presents its adaptabilities to traffic signal control systems. The simulation system in this paper has a function of real-time testing and evaluating traffic control systems. It consists of Modu-RE which is a simulation operating software and Real-CID which is a controller interface device. Real-CID allows Modu-RE to communicate with traffic control hardware.

  • PDF

Adaptive Algorithms for Yaw Moment Distribution with ESC and ARS (적응 알고리즘을 이용한 ESC와 ARS 기반 요 모멘트 분배)

  • Yim, Seongjin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.997-1003
    • /
    • 2016
  • This paper presents an application of adaptive algorithms for yaw moment distribution with electronic stability control (ESC) and active rear steering (ARS) in integrated chassis control (ICC). Integrated chassis control consists of upper- and lower-level controllers. In the upper-level controller, the control yaw moment is computed with sliding mode control required to stabilize a vehicle. In the lower-level controller, adaptive algorithms are applied to determine the required brake pressure of ESC and the necessary steering angle of ARS, in order to generate the control yaw moment. Simulation is performed using the vehicle simulation package CarSim to validate the proposed method.

Change of Cardiovascular Function of Industrial Workers Apply to Lumbar Stabilization Exercise according to the Floor Type (지면의 상태에 따른 요부안정화운동 적용 시 산업체 근로자의 심혈관기능 변화)

  • Kim, Chan-Kyu;Chae, Yun-Won;Kim, Myung-Hoon;Lee, Jeong-Hun;Ko, Dae-Sik;Jung, Dae-In
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.7
    • /
    • pp.225-232
    • /
    • 2009
  • This study conducted the following experiment to examine effects of cardiovascular function on lumbar stabilization exercise(LSE) in floor or swiss ball. This experiment was conducted to compare heart rate, systolic blood pressure, diastolic blood pressure and peripheral vascular oxygen saturation effects by lumbar stabilization exercise in floor or swiss ball with 18 normal adult and it divided 9 subjects. experiment group (1) is applying LSE on floor group and (2) is applying LSE on swiss ball group. Heart rate was measured by portable heart rate manometer, blood pressure was measured by hemodynamometer, and peripheral vascular oxygen concentration was measured using a computerized NURYTEC measuring apparatus analysis. These result lead us to the conclusion that systolic blood pressure and peripheral vascular oxygen concentration were influenced by LSE. but there was not differential effect between each groups. These results suggest that LSE has the capability to improve heart rate, blood pressure, peripheral vascular oxygen concentration. Consequently, LSE would be lead to increment of cardiovascular function.

A Detection and Stabilization Method for CNC Tool Vibration using Acoustic Sensor (음향센서를 활용한 CNC 공구떨림 감지 및 안정화 기법)

  • Kim, Jung-Jun;Cho, Gi-Hwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.2
    • /
    • pp.120-126
    • /
    • 2019
  • Recently, there is an increasing need for highly precise processing with the rapid development of precision machinery, electrical and electronics, and semiconductor industries. Cutting machine control relies on the operator's sense and experience in tradition, but it has been greatly enhanced by the adoption of CNC(Computerized Numeric Controller). In addition, cutting dynamics technology has been paid attention to reflect the operating state of machine in real time. This paper presents a method to detect and stabilize tool vibration by attaching an acoustic sensor to a CNC machine. The sensed acoustic data is synchronized with the tool position and the abnormal vibration frequency is separated from the collected acoustic frequency, then analyzed to detect the tool vibration. Also the reliability the tool vibration detection and stabilization is improved by applying the cutting dynamic method. The proposed method is analyzed and evaluated in terms of the surface roughness.

Conditions for Stable light Production of Recombinant Escherichia coli Containing Lux Operon and Sensitivity to Toxic Chemicals (Lux operon을 함유한 유전자 재조합 Escherichia coli의 발광 안정화 조건 및 독성물질에 대한 민감성)

  • 배희경;이상민;정윤철;송방호;신평균
    • KSBB Journal
    • /
    • v.17 no.6
    • /
    • pp.571-576
    • /
    • 2002
  • Recombinant E. coli DH5 ${\alpha}$/pSB311 was made by cloning the genes encoding bacterial luciferase and aldehyde substrate proteins from Photohabdus luminescense, to complement defects of Lumistox, which is normally used in bioassays to monitor toxic substances in water environmental systems. The conditions for stable light production by the recombinant strains were investigated with respect to cell growth stage, cell number, and buffer conditions. The optimum growth stage was a middle-exponential stage with an OD$_{660nm}$ value of 0.6-0.7. ADout 10$^{6}$-10$^{7}$ cells per test tube was optimum for stable light emission. The effect of buffer was not significant if an optimum viable cell number was maintained. The bioluminescence of the recombinant E. coli harboring the lux operon of Photohabdus luminescense was not affected by temperature, while the bioluminescence of Lumistox was temperature sensitive. The recombinant E. coli was more sensitive to heavy metals (Cd, Cu, Hg, Zn) than Lumistox, because it does not require high concentrations of NaCl in the buffer.

A Clinical Report on the Effect of CRS Usage in Degenerative Temporomanibular Joint Disease with Anterior Open Bite Applying Bone Scan (전치부 개교합을 보이는 퇴행성 관절질환에서 골스캔을 이용한 중심위교합장치의 효과 평가에 대한 임상례)

  • 박상배;김병국
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.3
    • /
    • pp.289-294
    • /
    • 1998
  • 본 증례는 측두하악관절의 퇘행성 변화를 보이는 환자에서 악교정 수술의 시행 전에 중심위교합장치를 통해 측두하악관절의 안정화를 유도하고, 또한 골스캔을 이용하여 장치의 치료효과를 평가한 임상증례이다. 환자는 24세의 여성으로 5년 전부터 전치부 개교합이 발생되기 시작하였고, 고형식 저작시 좌측 전이부에 간헐적인 통증이 발생한다는 주소로 본원에 내원하였다. 임상검사상 촉진시 양측 관절낭 후방부에 압통을 호소하였으며, 각각 50, 45mm의 최대개구량 및 최대무통성 개구량을 보였다. 좌측 악관절부에서 단순 관절 잡음, 우측 악관절부에서 염발음이 청취되었으며, 저항검사 및 부하 검사에서는 특기할 반응을 보이지 않았다. 약 7mm의 전치부 개교합의 소견을 보였으며, 파노라마 사진과 횡두개 방사선 사진 소견상 양측 과두의 크기 및 하악지의 높이가 다소 작은 소견이 관찰되었고 자기공명영상 소견상 양측성 비정복성 관절원판의 전방전위가 관찰되었다. 1997년 10월 27일 첫 번째 골스캔 소견상 양측성 비정복성 관절원판의 전방위가 관찰되엇다. 골스캔의 전방 사진에서 Densitometer를 이용하여 좌, 우측 과두부위와 상악 골부위의 가장 어두운 부분의 흑화도를 측정하였다. 각각 3회씩 구하여 평균을 구하고 좌, 우측 과두 대 상악골의 흑화도의 비율을 계산하였다. 첫번째 골스캔의 평균 흑화도는 우측 과두, 좌측과두, 상악골이 각각 0.88, 0.81, 1.32 였다. 1997년 11월 4일 중심위교합장치를 장착하였고 지속적인 물리치료를 시행하였다. 1997년 12월 10일 두 번째 골 스캔을 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.33, 0.37, 088 이었다. 1998년 1월 30일 세 번째 골스캔 소견상 두 번째 골스캔과 비교하여 활성도가 감소된 소견을 보였다. 임상검사시 무통이었다. 1998년 2월 25일 술 전 교정 위해 중심위교합장치의 장작을 중지시켰다. 1998년 6월 5일 네 번째 골스캔 소견상 이전 검사들과 비교시 흡수가 감소된 소견을 보였다. 네 번째 골스캔의 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.24, 0.19, 0.85 였다. 현재 지속적인 관찰 중이며 본원 교정과에서 악교정수술 위한 술 전 교장을 시행중이다. 결국 첫 번째 골스캔의 과두 대 상악골의 평균 흑화도의 비율은 우측과 좌측이 각각 0.66, 0.61이었고 두 번째 골스캔에서는 우측과 좌측이 각각 0.37, 0.42였고, 네번째 골스캔에서는 우측과 좌측이 각각 0.28, 0.23 이었다. 각 골스캔의 과두 대 상악골의 평균 흑화도의 비율 사이에 유의한 차이가 있는지 검증하기 위해 Standard t-test 와 ANOVA를 시행하였다. 이상의 결과에서 첫 번째, 두 번째, 네 번째 골스캔으로 갈수록 좌, 우측 과두 대 상악골의 흑화도의 비율이 유의하게 감소했음을 알 수 있었다. 결론적으로 본 증례에서는 전치부 개교합이 발생되어 악교정수술이 필요한 환자에게 측두하악관절의 안정화를 위해 중심위교합장치를 사용함으로써 퇴행성 관절질환의 진행을 억제시킬 수 있고, 퇴행성 관절질환의 활성도에 대한 평가시 골스캔이 유용할 수 있음을 보여주었다고 사료된다.

  • PDF

STABLIZATION OF THE EARLY ERUPTED FIRST PREMOLAR WITH FIXED APPLIANCE (고정식 장치를 이용한 조기 맹출 소구치의 안정화)

  • Hwang, JI-Won;Kim, Seong-Oh;Choi, Hyung-Jun;Choi, Byung-Jai;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.62-67
    • /
    • 2011
  • Early eruption refers to an accelerated eruption of a tooth beyond the normal eruption period. The clinical findings of an early erupted tooth with little formation of crown and/or root include severe mobility, pain on chewing, hypocalcification of the enamel, and inclination, displacement, and rotation of the tooth. The radiographic findings include underdeveloped root and insufficient bone support. Early eruption of a permanent tooth can cause several complications such as chronic trauma, pain, edema, an increased rate of premolar impaction and tooth displacement and/or rotation. Therefore, when a permanent tooth erupts earlier than its normal eruption period with accompanying symptoms, appropriate treatments should be done as soon as possible. A female patient of age 7 without any systemic disease was referred from a local dental clinic with chief complaint of severe mobilities and pain in both upper first premolars. According to the clinical and radiographic examinations, the permanent teeth erupted earlier with barely formed roots, severe mobilities, edema, and pain. This case is to report the successful accomplishment of root formations and stabilization of teeth after applying intraoral fixed appliances using bands and spurs for 14 months.

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.