• Title/Summary/Keyword: 안정한계

Search Result 1,455, Processing Time 0.024 seconds

A study on the engineering meanings of the critical strain concept in tunnelling (터널공학에서 한계변형률 개념의 공학적 의미에 관한 연구)

  • Park, Si-Hyun;Shin, Yong-Suk;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.2
    • /
    • pp.129-137
    • /
    • 2008
  • This paper intends to develop an assesment technique for the rapid and quantitative evaluation of tunnel safety during tunnel excavation by using displacement measurements. Control criteria for the field measurements are provided at tunnel construction sites in Korea and other countries. However, it was known that the criteria were not clear and varied depending on the construction sites. In order to make a reasonable support for guidelines, critical strain concept is introduced in this study. And the engineering meanings of the critical strain concept are investigated precisely. In order to do this, at first, the engineering meanings of the original concept from the previous researchers was investigated theoretically for the evaluation of tunnel safely. Subsequently displacement data were obtained by using the commercial program, then the evaluation of tunnel safely was conducted with the view point of previous researches. Additionally, strains are determined from the feedback analyses program by inputting measured displacements that were obtained from the commercial program, then the evaluation of tunnel safety was discussed with the critical strain concept. Consequently it can be concluded that the evaluation of tunnel safety can be determined quantitatively and rapidly in the field by introducing the critical strain concept.

  • PDF

Comparison Analysis of Factor of Safety on Rock Slope in Boeun Region Using Distinct Element Method and Limit Equilibrium Method (개별요소법과 한계평형법을 이용한 보은지역 암반사면 안전율 비교해석)

  • 이지수;유광호;박혁진;민경덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.33-41
    • /
    • 2003
  • The large planar failure has occurred in a rock cut slope of highway construction site in Boeun. This area is considered to be unstable since the discontinuity, whose orientation is similar to the orientation of the failure plane, is observed in many areas. Therefore, several analysis techniques such as SMR, stereographic analysis, limit equilibrium, numerical analysis, which are commonly used in rock slope stability analysis, are adopted in this area. In order to analyze the stress redistribution and nonlinear displacement caused by cut, which are not able to be obtained in limit equilibrium method, DEM and shear strength reduction technique were used in this study. Then the factors of safety evaluated by shear strength reduction technique and limit equilibrium were compared. In addition, the factor of safety under fully saturated slope condition was calculated and subsequently, the effect of the reinforcement was evaluated.

Engineering interpretation of critical strains in the ground based on the tunnel engineering (터널공학을 중심으로 한 한계변형률의 공학적 적용성)

  • Shin, Yong-Suk;Park, Si-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.403-410
    • /
    • 2009
  • This paper discusses an application method of critical strains concept for tunnels' safety by using the values of measured displacements which are obtained in the field. The aim of this paper is to: (1) study on the engineering meanings of critical strains concept by reviewing the previous researches and application examples with measured displacement values; (2) study on the engineering reasonability of critical strains concept with the view point of a tunnel engineering and a geotechnical engineering; (3) study on the features of ground deformation due to tunneling and reciprocal relation between total displacement and measured displacement; (4) evaluate a tunnel safety by using domestic measurements collected in the field; and (5) re-evaluate the control criteria which were previously used in the field, with the view point of critical strains concept. Consequently, it was confirmed that critical strains in the ground has a reasonability and a possibility of unified or common concept with the view point of a tunnel engineering.

Limit Velocity for Lateral Stable Bed in Natural Curved Channels (자연하천 만곡부의 횡방향 안정하상을 위한 한계속도)

  • Choe, Jong-In
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.195-201
    • /
    • 2002
  • In this study, an equation is proposed to estimate the limit velocity for lateral stable bed in a curved channel stream. The stable bed on lateral direction is satisfied when there is no more deformation occurs on the transverse bed slope and non-scouring condition in a bend. A theoretical equation for limit velocity is derived using a transverse bed slope model. So, the limit velocity has its theoretical background in the equilibrium of two forces, lateral shear force at the bed due to longitudinal flow and the corresponding lateral bed shear force. To verify the equation, data from four natural river channels were used. There is good agreement between the calculated values using this equation and the measured values. The corrections in equation was found to be correlated with the averaged particle Froude number.

Study on Critical_Allowable Shear Stress of Filling Rocks With Mattress Revetment (호안용 매트리스내 채움재의 한계_허용 전단응력에 관한 연구)

  • Bae, Sang-Soo;Lee, Seung-Yoon;Jee, Hong-Kee
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Critical and allowable shear stress acting on the mattress revetment, is presented in this study. First of all, shear stress at each spot is computed when the hydraulic power act on the waterway. Secondly, median diameter of the filling rocks is computed using shear stress and Shields coefficient which are used to decide the critical motion of the particle. Finally, the range of critical and allowable shear stress is estimated which meet the particle stability and indicated that the mattress is a stable hydraulic structure in comparison with the riprap. Therefore the required median diameter of riprap is three times higher than that of mattress. Contrarily, this study also analyzed that resisting power of mattress to shear stress is three times higher than that of riprap on the same size.

Effects of Axial Force on Deformation Capacity of Steel Encased Reinforced Concrete Beam-Columns (매립형 SRC 기둥재의 변형성능에 대한 축력의 영향)

  • Chung, Jin-An;Yang, Il-Seung;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.251-259
    • /
    • 2003
  • In this paper, an analytical approach hwas been conductsed to clarify the relationships between the axial force and the deformation capacity of steel- encased reinforced- concrete beam-columns. The analytical model was defined as a cantilever. Several parameters influencing the inelastic performance of the beam-columns were selected, as follows: including encased steel area ratios, and sectional shapes of the encased steel, material strengths, and shear-span- to-depth ratios. The Analytical results of the analysis showed that the axial force had to have a maximum limit to ensure the stable behavior of a steel- encased reinforced- concrete beam-column when it was subjected to both axial and repeated lateral loading under a constant rotation angle amplitude. The maximum axial force of the beam-column to be resisted under cyclic lateral loading was defined as the stable-limit axial force to ensure the required rotation angle amplitude. The Analytical results of the analysis indicate that the stable-limit axial load ratio increases as the steel strength increases or as the compressive strength of the concrete decreases. The stable-limit axial load ratio decreases as the encased steel ' s sectional area increases in the case of a 1-shaped sections and it is almost not influenced by the steel sectional area in the case of a cross-shaped section.

Stability Assessment of Abandoned Gangway for Commercial Utilization of Services (서비스업 활용을 위한 광산 폐갱도의 안정성 평가)

  • SunWoo, Choon;Chung, So-Keul;Lee, Yun-Su;Kang, Sang-Soo;Kang, Jung-Seok
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.297-309
    • /
    • 2012
  • The stability assessment of abandoned gangway for the purpose of services was performed. Among the many factors that affect the stability of openings, the span of the opening in a given rock mass condition provides an important element of design. In this paper, the stability of gangway was assessed by the critical span curves proposed by Lang, the modified Mathews'stability graph method and using support measures of the Q system. In the evaluation of stability as a whole the gangway is considered as stable. But the rockfalls of wedge-shaped blocks were expected in the area in which the horizontal joints of low angle appear. The support measures such as local rock bolts are required to use for commercial purposes of the abandoned gangway. And entrance section may require the particular attention as unstable section. Since there are so many spalling due to bad blasting in the roof and sidewall of gangway, the scaling operations should be followed primarily.

Stability Limit Properties of a Control System on the Space of Adjustable Parameters (조정파라미터 공간에서의 제어계 안정한계 특성)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.351-356
    • /
    • 2001
  • In this paper, a general one-loop control system was assumed as a model system which has a time-delay element connected with a first order-lag element in series. After the corresponding parameter set causing stability limit condition for the model system was obtained by mathematical procedures, their loci on the parameter space was taken according of frequency change,. The parameter set loci of stability limit showed a specific pattern, and particularly the curves on the Kp-Ti parameter space were able to generalized in the form of an exponential formula. These properties were also compared with the results taken from experimental procedures by Nyquist response method and Ziegler & Nichols method on the time domain, and both results were confirmed to be nearly same.

  • PDF

Development of a Structural Safety Evaluation System for Stone Voussoir Arch Bridges (석조 홍예아치교의 구조적 안정성 평가시스템 개발)

  • Kim, Nam-Hee;Koh, Hyun-Moo;Hong, Sung-Gul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • Masonry structures that are very strong in compression fail due to the instability of structural shape of geometry rather than the material stress limit. Considering such structural behavior, the use of the limit theorem that focuses on structural collapse mechanisms is more appropriate for the evaluation of the structural safety of stone voussoir arch bridges. This paper is to investigate structural performance of the stone arch bridges constructed using dry construction method in Korea based on the limit theorem and to exploit the result to develop a system for an structural safety margin. It is expected that this study will help us understand structural behavior of stone voussoir arch bridges in Korea. Also, it will provide a guideline to make engineering decision from the viewpoint of the maintenance of cultural heritages.