• Title/Summary/Keyword: 안전선

Search Result 2,587, Processing Time 0.029 seconds

Acute Ecotoxicity Evaluation of 3 Emulsifiable Concentrates Containing Garlic Extract, Zanthoxylum Extract, and Lemon Grass Oil Originated from Plant (식물추출물 마늘 추출액, 잔톡실럼 정유, 레몬그라스 정유 함유 유제 3종의 생태독성평가)

  • You, Are-Sun;Hong, Soon-Sung;Jeong, Mihye;Park, Kyung-Hun;Chang, Hee-Seop;Lee, Je Bong;Park, Jae-Yup
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.376-382
    • /
    • 2012
  • Environment-friendly agro-materials are are likely to be preferred to chemical insecticides recently. For this reason, many studies are conducted to develop environment-friendly insecticides containing natural materials. This study was also conducted so as to assess ecotoxicity for Emulsifiable concentrate (EC) containing 30% of garlic extract or two plant essential oils (Zanthoxylum, Lemongrass) expected to prevent from pests and be used for agro-materials. Target species used to assess acute toxicity were invertebrate (Daphina magna), fish (Oryzias latipes), honeybee (Apis mellifera L.) and earthworm (Eisenia fetida). The $EC_{50}$ values for of garlic extract 30% EC, Zanthoxylum oil 30% EC and lemongrass oil 30% EC to Daphina magna were 3.3, 10, and $10mg\;L^{-1}$, respectively. The category of garlic extract 30% EC was moderately toxic, while those of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were slightly toxic according to standard of USEPA. $EC_{50}$ for both of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were more than $10mg\;L^{-1}$ then they were considered as slightly toxicity. In case of acute toxicity test to fish, $LC_{50}$ of garlic extract 30% EC was $3.3mg\;L^{-1}$. Zanthoxylum oil 30% EC and lemongrass oil 30% EC indicated $LC_{50}$ > $10mg\;L^{-1}$. Classification of acute toxicity to all test substances was in Korea criteria. Acute contact and oral toxicity test to Honeybee were conducted. As a result, $LD_{50}$ of all test substances were more than 100 a.i. ${\mu}g\;bee^{-1}$ in the acute contact test while $LD_{50}$ of garlic extract 30% EC was 4.4 a.i. ${\mu}g\;bee^{-1}$ and $LD_{50}$ of Zanthoxylum oil 30% EC and lemongrass oil 30% EC were more than 100 a.i. ${\mu}g\;bee^{-1}$. In case of acute toxicity test to earthworm, $LC_{50}$ of garlic extract 30% EC, Zanthoxylum oil 30% EC and lemongrass oil 30% EC were 267, 592, and $430mg\;kg^{-1}$, respectively. In conclusion, if the safety for earthworm is confirmed, these substances are expected to be use for environment-friendly insecticide materials with low risk against ecosystem and contribute to developing environment-friendly agro-materials.

The Listing Procedure for environmental friendly organic materials in Korea (한국의 친환경유기농자재 목록공시 제도)

  • Lee, Sang-Beom;Seung, J.O.;Kim, S.S.;Kim, B.S.;Lee, B.M.;Oh, Y.J.;Kang, C.K.;Choi, K.J.;Hong, M.K.
    • Proceedings of the Korean Society of Organic Agriculture Conference
    • /
    • 2009.12a
    • /
    • pp.275-276
    • /
    • 2009
  • 민간단체들에 의하여 자율적으로 시작된 국내 유기농업은 친환경농업육성법(1997. 12.13)이 제정되면서 국가기관의 친환경농업 활성화 노력과 더불어 2008년 유기농재배 농가(8,460호)와 면적(12,033호)이 급격히 증가되었다. 또한 유기농업의 확산과 더불어 화학비료 및 유기합성 농약대체 친환경농자재들의 유통이 증가되고 있으나 관리규정이 없어 검증되지 않은 다양한 농자재들이 유통되어 친환경실천 농가들의 혼란이 초래되어 국정감사 시 문제점으로 지적과 함께 각계에서 관리제도의 필요성이 대두되었다. 친환경농업육성법 시행령 개정(대통령령 제19964호, 2007.3.27.공포, 2007.3.28.시행)으로 농촌진흥청에 친환경농자재심의회가 설치되어 효과와 효능을 검증하지 아니하고 친환경농산물 중 유기농산물 생을 해 사용가능한 자재인지 여부를 검토하여 그 결과를 공개하는 목록공시제가 마련되었다. 친환경유기농자재 목록공시는 1년에 4회 매분기말에 농촌진흥청 농자재관리과에서 접수를 받아 친환경농자재 분야별 전문위원회 검토 후 심의위원회 심의를 거쳐 접수일로부터 90일 이내에 농촌진흥청장이 공시(농진청 홈페이지, 관보게재)하고 친환경농업 관련기관 및 검토 신청자에게 통보함으로서 마무리된다. 목록 공시된 친환경유기농자재의 유효기간은 2년이다. 친환경농자재심의위원회는 토양개량 및 작물생육분야 전문위원회 위원 11명, 병 해충 관리분야 전문위원회 위원 11명 및 심의위원회 의원 20명으로 구성되어 있다. 2007년 3월부터 2009년 11월 30일 현재 목록 공시된 친환경유기농자재 제품은 (1) 양개량용 자재 25 개, (2) 작물생육용 자재 282개, (3) 토양개량 및 작물생육용 자재 308개, (4) 작물병해 관리용 자재 110개, (5) 작물충해 관리용 자재 : 224개, (6) 작물병해충 관리용 자재 5개 및 (7) 기타 자재 1개 제품으로 총 955개 제품에 이르고 있다. 한편, 공시연장 미신청, 현재 검토기준안에 필요로 하는 추가요청 자료 미제출 및 공시이외의 물질 사용으로 국내유통 중 단속되어 부적합한 판정을 받아 20여 제품이 목록공시가 취소되었다. 앞으로 목록 공시되는 친환경유기농자재는 제품의 주성분 함량 표기, 시용효과 검정방법 선, 제조방법 현장점검, 안전성 검정 등 여러가지 제도보완 및 사후관리 방안이 시급히 마련되어야 할 것으로 사려된다.

  • PDF

Significance of p53 as a Prognostic Factor in Non-Small Cell Lung Carcinoma (비소세포 폐암종에 있어서 p53의 예후 인자로서의 의의)

  • 이상호;한정호;김관민;김진국;심영목;장인석
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.672-683
    • /
    • 2004
  • Background: The treatment results of the advanced lung carcinoma is not satisfactory with the present therapeutic modalities: surgical resection, anti-cancer chemotherapy, and radiotherapy or combination therapy. To predict the prognosis of the non-small-cell lung carcinoma, TNM classification has been was as the basic categorization; however, it has been not satisfactory. It is necessary to consider the causes and the prognosis of the lung carcinoma from another points of view rather the conventional methods. We intended to find out the relationship between the major apoptotic factor, p53 gene and the prognosis of the patient with lung carcinoma. Material and Method: Three hundreds and fifty-nine patients with lung carcinoma who underwent surgery were analysed. We observed p53 protein accumulated in the cellular nuclei. The p53 protein was detected by immuno-histo-chemical method. We collected information of the patient retrospectively. Result: p53 protein densities were observed in 40% in average as a whole. The protein density was 44 percent in man, 25 percent in woman, 49 percent in the squamous cell carcinoma, and 38 percent in the adenocarcinoma. There were significant correlations between the p53 protein density and the mortality in the squamous cell carcinoma (p=0.025), follow-up duration in TNM stage I group (p=0.010), and follow-up duration in the lobectomy patient group (p=0.043), and tumor cell differentiation (p=0.009). p53 protein densities were significantly different between the lobectomy and the pneumonectomy group (p=0.044). Conclusion: The authors found that p53 protein had some correlations with the prognosis of the lung cancer partially in some factors. We suggest the p53 protein density could be used as a marker of prognosis in the non-small-cell lung carcinoma.

Monitoring Methylmercury in Abyssal Fish (심해성 어류 중 메틸수은 모니터링)

  • Kim, Seong-Cheol;Jang, Jin-Wook;Kim, Hyun-Ah;Lee, Sang-Ho;Jung, Young-Ji;Kim, Ji-Yeon;Ahn, Jong-Hoon;Park, Eun-Hye;Ko, Yong-Seok;Kim, Dong-Sul;Kim, Sang-Yub;Jang, Young-Mi;Kang, Chan-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.383-389
    • /
    • 2010
  • The aim of this study was to determine the methylmercury (MeHg) levels in abyssal fish species. The MeHg in the fishes was extracted with hydrochloric acid and toluene and then purified using an L-cysteine solution. The extract was analyzed with a gas chromatography-electron capture detector (GC-${\mu}ECD$) with a thermon Hg-capillary column. The detection limit and the recovery of the method were 0.002 and 84.2-98.5% (mean, 93.4%), respectively. The MeHg content in 492 abyssal fishes ranged from 0.037 to 2.009 mg/kg. The levels of MeHg [range, mg/kg (mean)] were significantly dependent on fish species and presented as the following; 0.157-2.009 (0.546) in Scalloped hammerhead shark, 0.211-0.878 (0.501) in Blue shark, 0.121-0.993 (0.482) in Spiny dogfish, 0.243-0.658 (0.397) in Salmon shark, 0.074-1.958 (0.353) in Blacktip shark, 0.038-0.807 (0.302) in Southern hake, 0.099-0.511 (0.300) in Scorpion fish, and 0.037-0.133 (0.067) in Ling. The monitoring results showed that the estimated weekly intake of MeHg from sharks, Southern hake, and Ling were lower than the provisional tolerable weekly intake recommended by the Joint FAO/WHO expert committee on food additives.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Potential Reproductive Toxicity Study of p53 Expressing Adenoviral Vector in Mice (아데노바이러스 유전자치료벡터의 생식독성 연구)

  • Rhee, Gyu-Seek;Kwack, Seung-Jun;Kim, Soon-Sun;Lee, Rhee-Da;Seok, Ji-Hyun;Chae, Soo-Young;Chung, Soo-Youn;Kim, Seung-Hee;Lee, Seung-Hoon;Park, Kui-Lea
    • Korean Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.151-158
    • /
    • 2007
  • The possibility of inadvertent introduction of therapeutic gene expressing viral vectors has raised safety concerns about germ-line infection. Particularly, for indications such as prostate cancer and ovarian cancer, the proximity of the point of viral administration to organs of the reproductive system raises concerns regarding inadvertent germ-line transmission of genes carried by the virus vector. To evaluate the safety of in vivo adenovirus mediated gene transfer, we explored the biodistribution, persistance and potential germ-line transmission of p53-expressing adenovirus (Ad-CMV-p53). Both male and female Balb/c mice were injected with $1{\times}10^9$ PFU of Ad-CMV-p53. The PCR analysis showed that there were detectable vector sequences in liver, kidney, spleen, seminal vesicle, epididymis, prostate, ovary, and uterus. The RT-PCR analysis for detecting inserted gene, p53 showed that Ad-CMV-p53 viral RNA were present in spleen, prostate and ovary. Direct injected male and female mice of adenovirus vector into testis and ovary were mated and their of offspring were evaluated for germ-line transmission of the adenoviral vector. The PCR and RT-PCR analysis showed no evidence of germline transmission, although vector sequences were detected in DNA extracted from gonadal tissues. Real-time PCR result confirmed a significant decrease of adenovirus in gonad tissues 1 week after injection. We have also analysed the cell specific localization of viral DNA in gonad tissues by using in-situ PCR. Positive signals were detected in interstitial tissue but not in seminiferous tubule in sperm. In the case of ovary, adenovirus signal were localized to the stromal tissue, but no follicular signals were observed. Together, these data provide strong evidence that the risk of the Inadvertent germ-line transmission of vector sequences following intraperitoneal or direct injection into genito-urinary system of adenovirus is extremely low.

Construction of Retrovirus Vector System for the Regulation of Recombinant hTPO Gene Expression (재조합 hTPO 유전자의 발현 조절을 위한 Retrovirus Vector System의 구축)

  • Kwon, Mo-Sun;Koo, Bon-Chul;Kim, Do-Hyang;Kim, Te-Oan
    • Reproductive and Developmental Biology
    • /
    • v.31 no.3
    • /
    • pp.161-167
    • /
    • 2007
  • In this study, we constructed and tested retrovirus vectors designed to express the human thrombopoietin gene under the control of the tetracycline-inducible promoters. To increase the hTPO gene expression at him-on state, WPRE sequence was also introduced into retrovirus vector at downstream region of either the hTPO gene or the sequence encoding reverse tetracycline-controlled transactivator (rtTA). Primary culture cells (PFF, porcine fetal fibroblast; CEF, chicken embryonic fibroblast) infected with the recombinant retrovirus were cultured in the medium supplemented with or without doxycycline for 48hr, and induction efficiency was measured by comparing the hTPO gene expression level using RT-PCR, western blot and ELISA. Higher hPTO expression and tighter expression control were observed from the vector in which the WPRE sequence was placed at downstream of the hTPO (in CEF) or rtTA(in PFF) gene. This resulting tetracycline inducible vector system may be helpful in solving serious physiological disturbance problems which have been a major obstacle in successful production of transgenic animals.

Geochemical Characteristics of the Gyeongju LILW Repository II. Rock and Mineral (중.저준위 방사성폐기물 처분부지의 지구화학 특성 II. 암석 및 광물)

  • Kim, Geon-Young;Koh, Yong-Kwon;Choi, Byoung-Young;Shin, Seon-Ho;Kim, Doo-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.307-327
    • /
    • 2008
  • Geochemical study on the rocks and minerals of the Gyeongju low and intermediate level waste repository was carried out in order to provide geochemical data for the safety assessment and geochemical modeling. Polarized microscopy, X-ray diffraction method, chemical analysis for the major and trace elements, scanning electron microscopy(SEM), and stable isotope analysis were applied. Fracture zones are locally developed with various degrees of alteration in the study area. The study area is mainly composed of granodiorite and diorite and their relation is gradational in the field. However, they could be easily distinguished by their chemical property. The granodiorite showed higher $SiO_2$ content and lower MgO and $Fe_2O_3$ contents than the diorite. Variation trends of the major elements of the granodiorite and diorite were plotted on the same line according to the increase of $SiO_2$ content suggesting that they were differentiated from the same magma. Spatial distribution of the various elements showed that the diorite region had lower $SiO_2,\;Al_2O_3,\;Na_2O\;and\;K_2O$ contents, and higher CaO, $Fe_2O_3$ contents than the granodiorite region. Especially, because the differences in the CaO and $Na_2O$ distribution were most distinct and their trends were reciprocal, the chemical variation of the plagioclase of the granitic rocks was the main parameter of the chemical variation of the host rocks in the study area. Identified fracture-filling minerals from the drill core were montmorillonite, zeolite minerals, chlorite, illite, calcite and pyrite. Especially pyrite and laumontite, which are known as indicating minerals of hydrothermal alteration, were widely distributed in the study area indicating that the study area was affected by mineralization and/or hydrothermal alteration. Sulfur isotope analysis for the pyrite and oxygen-hydrogen stable isotope analysis for the clay minerals indicated that they were originated from the magma. Therefore, it is considered that the fracture-filling minerals from the study area were affected by the hydrothermal solution as well as the simply water-rock interaction.

  • PDF

Changes in Quality Characteristics of Fresh-cut Produce during Refrigerated Storage (냉장 저장 중 신선편이 농산물의 품질특성 변화)

  • Sun, Shih-Hui;Kim, Su-Jin;Kim, Gi-Chang;Kim, Haeng-Ran;Yoon, Ki-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.495-503
    • /
    • 2011
  • We evaluated the quality characteristics of fresh-cut produce (potato, sweet potato, carrot, radish, zucchini, cucumber, and green bell pepper) washed with sodium hypochlorite, which were vacuum packaged, and stored at 4 and 10$^{\circ}C$. The L-values of the fresh-cut potato and sweet potato decreased during storage. Lower PPO activities of potato and sweet potato were observed at 4$^{\circ}C$ than those at 10$^{\circ}C$ and development of potato and sweet potato browning was delayed at 4$^{\circ}C$. Total aerobic count and coliform increased continuously at 10$^{\circ}C$ during storage. Diced zucchini and shredded sweet potato had the greatest reduction in hardness among the fresh-cut produce during storage. Differences in the rate of quality change were observed according to the kinds and cut types of produce. Thus, a quality maintenance period for each type of fresh-cut produce must be determined, which will lead to the safe use of fresh cut produce in foodservice establishments.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.