• Title/Summary/Keyword: 안전관리 평가지수

Search Result 127, Processing Time 0.026 seconds

Basic Data Analysis of the Quality Control for Patient Safety in Department of Radiation Oncologyat Yeungnam University Hospital (영남대학교병원의 환자안전을 위한 정도관리의 기초자료 분석)

  • Oh, Se An;Kim, Sung Kyu;Yea, Ji Woon;Kang, Min Kyu;Lee, Joon Ha;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.112-117
    • /
    • 2015
  • In order to establish the quality control on patient safety following the guideline presented by American Association of Physicists in Medicine (AAPM) TG-100 committee, we aim to analyze the modes based on errors occurred during treatment of patients at the radiation oncology department at Yeungnam University Hospital and establish a quality control guideline for patient safety when patient-centered radiation treatment is conducted. We aim to analyze the errors that can occur during radiation treatment at the radiation department, and assess the frequency of error, the severity of error affecting patients, and probability of proceeding without noticing error, with scores. The places where errors can take place were divided into CT simulation treatment room, treatment planning room, and treatment room for the analysis. In CT simulation treatment room, an error from using the immobilization device showed the highest Risk Priority Number (RPN) value of 60, and an error from simulation treatment information input showed the lowest of 6. In treatment planning room, an error from selecting the radiation dose calculation model showed the highest RPN value of 168, and an error of patient treatment start date showed the lowest of 36. In treatment room, a Table Bar error showed the highest RPN value of 252, a weight change error showed 190, and a Pillow error showed the lowest of 24.

Multifactorial Risk Based Prioritization of Foreign Matters in Food (식품이물의 다인자기반 위해평가 및 우선순위 설정)

  • Kim, Hyun Jung;Choi, Sung-Wook;Chun, Hyang Sook
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.83-88
    • /
    • 2013
  • Foreign matters in foods are important food safety issue of consumers, retailers, food manufacturers and food safety authorities in Korea. In order to provide information for development of risk management options and detection technology for foreign matters, multifactorial risk of foreign matters in foods was estimated based on various factors including detection rate, health adverse effect, economic and social aspects. For the each of five food items and foreign matters which were selected from previous study, factors including detection rates, health adverse effects, annual production amounts and willingness to additional pay to reduce foreign matters in foods were quantitatively estimated. The highest risk score was estimated for metal-noodle combination followed by insect-noodle and metal-beverage combinations. The multifactorial risk assessment on foreign matters in food could provide useful information to support risk managers and scientist in complex decision making when various factors should be concerned and different food-foreign matter combinations are compared.

Real-time Health Monitoring of Pipeline Structures (배관 구조물의 상시 건전성 모니터링)

  • Kim, Ju-Won;Kim, Tae-Heon;Lee, Chang-Gil;Park, Seung-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.666-669
    • /
    • 2010
  • 여러 가지 지하시설물 중 국가 주요 자원의 수송망을 책임지는 주요구조물인 수도관, 가스관등의 배관구조물은 접근이 쉽지 않은 지하공간에 복잡하게 연결되어 있어 그 중요성에 비해 유지, 관리, 보수가 쉽지 않았다. 이러한 배관구조물을 균열, 조인트 풀림 등의 손상으로부터 보다 안전하고 효율적으로 관리하기 위하여 상시적 배관구조물 손상진단기법을 연구하였다. 이를 위해 배관 구조물 시험체에 볼트풀림, notch 등과 같은 손상에 대하여 대표적인 압전센서인 PZT와 MFC를 부착하고 임피던스기법 및 유도 초음파기법을 적용하여 볼트풀림개수, notch 손상개수 증가에 따른 출력신호를 반복 계측하였다. 객관적인 평가를 위해 계측된 신호를 신호처리기법인 웨이블렛 변환을 수행하고, RMSD 및 1-CC의 손상지수를 사용하여 구조물손상을 정량화 시켰으며 이를 토대로 구조물의 건전성의 기준이 되는 임계값을 설정함으로서 임피던스와 유도초음파 두 검색기법을 이용한 상시적 배관구조물 건전성 모니터링의 가능성을 살펴보았다.

  • PDF

Development of a Water Quality Indicator Prediction Model for the Korean Peninsula Seas using Artificial Intelligence (인공지능 기법을 활용한 한반도 해역의 수질평가지수 예측모델 개발)

  • Seong-Su Kim;Kyuhee Son;Doyoun Kim;Jang-Mu Heo;Seongeun Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.1
    • /
    • pp.24-35
    • /
    • 2023
  • Rapid industrialization and urbanization have led to severe marine pollution. A Water Quality Index (WQI) has been developed to allow the effective management of marine pollution. However, the WQI suffers from problems with loss of information due to the complex calculations involved, changes in standards, calculation errors by practitioners, and statistical errors. Consequently, research on the use of artificial intelligence techniques to predict the marine and coastal WQI is being conducted both locally and internationally. In this study, six techniques (RF, XGBoost, KNN, Ext, SVM, and LR) were studied using marine environmental measurement data (2000-2020) to determine the most appropriate artificial intelligence technique to estimate the WOI of five ecoregions in the Korean seas. Our results show that the random forest method offers the best performance as compared to the other methods studied. The residual analysis of the WQI predicted score and actual score using the random forest method shows that the temporal and spatial prediction performance was exceptional for all ecoregions. In conclusion, the RF model of WQI prediction developed in this study is considered to be applicable to Korean seas with high accuracy.

Status of Health and Safety Management in Occupational Hygiene Laboratories in Korea

  • Yang, Hyukseung;Choi, Jaewook;Yoon, Seokjoon;FARR, Terry
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.53-62
    • /
    • 2007
  • 목적: 1990년대 초반부터 시작된 우리나라의 산업 보건에 대한 사회적 관심의 증대와 시장의 요구에 따라 산업위생기관의 양적인 팽창이 이루어지긴 하였으나 실험실 관련 안전보건규정이 미비한 상태에서 추진되어 산업위생 실험실에서 다양한 유해 위험성 인자를 취급함에도 불구하고 사용되는 량이 소규모로 인해 안전보건과 관련된 사항은 대부분 간과하고 있으며, 산업위생 실험실의 안전보건관리 실태는 선진외국에 비해 상당히 낙후되어 있는 실정이다. 따라서 본 연구는 우리나라 산업위생 실험실과 관련한 안전보건관리 실태를 평가함으로써 향후 실험실의 안전보건관리 수준을 향상 시키는데 효과적인 자료로 활용하는데 기여하고자 한다. 방법: 산업위생실험실의 안전보건 실태를 파악하기 위해 설문조사를 수행하였으며, 설문은 실험실의 전반적인 안전보건, 화학물질 저장 및 용기, 가연성 및 인화성 화학물질, 가스 실린더, 의사전달, 응급처치 및 비상사태 장비, 정리정돈, 소방안전, 전기안전, 개인보호구, 흄후드 및 환기, 및 이황화탄소 취급 사례로서 12개 영역으로 구성되었다. 연구대상은 2001년 한국산업안전공단 정도관리프로그램에 참여한 기관으로서 총 대상은 119개 기관이었다. 연구기간은 2002년 7월 01일부터 8월 30일까지 약 60일 이었다. 설문은 반송봉투에 넣어 설문완성 후 연구자에게 보낼 수 있도록 배려하였으며, 1차 설문을 보낸 후 2주 후에 설문 참여를 독려하기 위해 엽서를 발송하였고, 다시 2주 후에 각 산업위생기관에 개별 전화 연락을 취하였다. 그 결과 63% (75개 기관)의 완성된 설문을 얻을 수 있었다. 설문의 총 조사항목은 79문항으로 구성되어 있으며, 산업위생실험실의 안전보건 수준을 정량적으로 평가하기 위해 안전보건 매뉴얼, 교육훈련프로그램 및 한국산업안전공단 실험실 지침서를 보유한 기관과 그렇지 않은 기관간의 차이는 선별된 67문항에 대해 각 문항에 합당하거나 적절할 경우 1점을 부여하는 방식으로 점수화하였다. 이들의 관련성을 파악하기 위하여 Microsoft-Excel 2000 프로그램을 이용하여 two-tailed t-test 분석을 실시하였다. 결과 1. 산업위생실험실 운영과 관련한 67개 항목(항목별로 각 1점 부여)에 대한 안전보건 성과지수화 (100점으로 점수 환산) 결과 안전보건 매뉴얼을 보유한 기관은 $42.98{\pm}13.36$(p<0.001)점, 교육훈련프로그램을 보유한 기관은 $50.75{\pm}14.12$(p<0.01)점, 한국산업안전공단 실험실 지침서를 보유한 기관은 $43.58{\pm}11.92$(p<0.01)점으로 그렇지 않은 기관에 비해 통계적으로 유의하게 높은 점수분포를 보였다. 2. 화학물질 보관 캐비닛이 있는 기관 중 64.8%의 기관은 화학물질을 알파벳 순으로, 27.8%는 분류 기준에 따라, 그리고 7.4%는 무작위로 보관하고 있었다. 3. 단지 8.0% (6개)의 기관만이 실험실내에 눈세정 분수(2 개), 샤워기(3개) 및 눈세정물병(3개, 2개 중복 응답 기관)과 같은 응급처치 장치 및 물품을 갖추고 있었다. 4. 89.0%의 기관이 흄후드내에 화학물질을 보관하고 있었다. 5. 물질안전보건자료, 흄후드 기록지, 비상사태 절차서 및 한국산업안전공단 실험실 지침서와 같은 문서관리는 부적절하게 관리 및 기록되고 있었다. 6. 대부분의 산업위생 실험실은 응급처치 장비, 화학물질 또는 가스용기 보관실과 같은 실험실 안전설비가 부족할 뿐만 아니라 정리정돈, 화학물질 저장 캐비닛, 안전보호구 및 흄후드와 같은 관리가 미비하였다. 결론: 이상의 결과에 근거하여 기관장은 실험실의 안전보건관리를 위하여 문서관리체계를 제공하고, 모든 실험실 종사자가 적절한 개인보호구를 착용할 수 있도록 하며, 비상 장비를 설치하고, 실험실과 관련한 적절한 규정을 제정하며, 교육훈련 프로그램을 제공하여야 한다. 또한 실험실 종사자는 실험 중 적절한 개인보호구의 착용하고, 비상장비 이용에 대한 교육훈련에 참여하며, 적절한 실험실 운영관리에 대한 책임감을 가져야 한다. 위의 권고사항 이행을 위해서 KOSHA는 KQCP 프로그램에 실험실 안전보건관리 항목을 삽입하여 주기적인 평가를 수행할 필요가 있다. 우리나라 실험실의 특성을 고려할 때 본 연구결과는 일반 실험실에도 적용될 수 있을 것으로 생각된다.

The Case Study for the UNISDR Certification of the Making Resilience City - Focusing on the Busan Geumjeong gu - (UNISDR의 재해에 강한 도시 만들기 사례 연구 - 부산광역시 금정구를 중심으로 -)

  • Lee, Taeshik;Kim, Yongmoon;Cheung, Chongsoo;Seok, Geumcheol;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2016
  • This research has been shown the systematic method about that the disaster resilient city make to certificate the UNISDR's role model city, the first case study in Korea, of that the Busan Geumjeong-gu city project to take part in and to lead the campaign of the 'Climate Change, the making resilient city' in Korea. For the making the life safety community, we research and analysis and apply the 10 Essentials and 41 Key Questions of the campaign making UNISDR's disaster resilient city, and check the disaster management items about the government and local ones ordering every years, and study to analyze the Geumjeong-gu factors about the seven checklists of life safety improvement, and educate and train and make the questionnaire for the safety campaign the citizen and volunteer in the 17 local areas, and show the vision and target, and 5 steps approaching strategy of 'Climate change, the making resilient city,'

Load-carrying Capacity Evaluation Method for RC Slab Bridges using the Damage Evaluation Process (손상도 평가 프로세스를 이용한 RC 슬래브 교량의 공용내하력 평가 방안)

  • Lee, Hee-Hyun;Kim, Yuhee;Jeon, Jun-Chang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.543-553
    • /
    • 2023
  • This study was conducted to propose a simple method to evaluate the load-carrying capacity of RC slab bridges, which have been most frequently constructed in Korea. A number of RC slab bridges have been considerably deteriorated associate with the long service year. However, since these bridges are not included in the 1st and 2nd class infrastructures due to their short span length, they have been relatively neglected compared to other bridge types in terms of safety management. In the previous theoretical study, a process (draft) was proposed for evaluating the damage of RC slab bridges using the relationship between the displacement response ratio and the stiffness reduction rate derived by the measured displacement and natural frequency. In this paper, to verify the validity of the proposed damage evaluation process (draft), the results to the actual bridges were compared with the safety grade and the Matsui's deterioration index. In addition, to enhance the practical applicability of the existing process (draft), an improved method approximately evaluating the load-carrying capacity using only the measured natural frequency was presented. If an error of 10% of the load-carrying capacity is allowed, it is judged that the proposed damage evaluation process can be appropriately used not only for evaluating the safety of RC slab bridges, but also for determining priorities for their maintenance.

Derivation of Building Fire Safety Assessment Factors for Generating 3D Safety Status Map (3D 안전상태지도 제작을 위한 건물 화재안전 평가항목 도출)

  • Youn, Junhee;Kim, Taehoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.40-47
    • /
    • 2020
  • Various technologies, systems, and legal systems are applied to prevent and quickly respond to fire disaster; nevertheless, the damages to life and property caused by fires are not reduced every year. For managing fire disaster, generating spatial information-based safety status map and procuring suitability of attribute information for each position information are essential. The safety status map is generated by deriving the fire safety status assessment factors, indexing, and locating the surveying results through various methods. In this paper, we deal with derivation of building fire safety assessment factors for 3D safety status map. At first, we survey the foreign and domestic fire assessment model cases and its factors, and analyze the applicability of Korean 3D fire safety status map. Next, assessment factors for fire safety assessment model are derived. Assessment factors are derived and categorized by their information collecting activity; factors that can be accessed through basic building information and factors that can be accessed through field survey. As a derivation result, 14 assessment factors were derived over five categories(Industry Risk, Structural Risk, Fire Fighting Facility, Fire Dangerousness, Fire Response Status).

Review of Assessing Soil Quality Criteria for Environmentally-Sound Agricultural Practics and Future Use (환경적으로 안전한 농업과 미래용도를 위한 토질 기준 평가 검토)

  • Doug Young Chung
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.2
    • /
    • pp.127-145
    • /
    • 1998
  • Unlike water or air quality standards that have been established by legislation using potential human health impact as the primary criterion, soil quality depends on the soils primary function and its relevant environmental factors, which is much more site- and soil specific. A properly characterized soil quality assessment system should serve as an indicator of the soil capacity to produce safe and nutritious food, to enhance human and animal health, and to overcome degrative processes. For our proposed example, a high quality soil with regard to maintaining an adequate soil productivity as a food production resources must accommodate soil and water properties, food chain, sustainability and utilization, environment, and profitability, that (i) facilitate water transfer and absorption, (ii) sustain plant growth, (iii) resist physical degradation of soil, (iv) produce a safe food resources, (v) cost-effective agricultural management. Possible soil quality indicators are identified at several levels within the framework for each of these functions. Each indicator is assigned a priority or weight that reflects its relative importance using a multi-objective approach based on principles of systems to be considered. To do this, individual scoring system is differentiated by the several levels from low to very high category or point scoring ranging from 0 to 10, And then weights are multiplied and products are summed to provide an overall soil quality rating based on several physical and chemical indicators. Tlne framework and procedure in developing the soil quality assessment are determined by using information collected from an alternative and conventional farm practices in the regions. The use of an expanded framework for assessing effects of other processes, management practices, or policy issues on soil quality is also considered. To develop one possible form for a soil quality index, we should permit coupling the soil characteristics with assessment system based on soil properties and incoming and resident chemicals. The purpose of this paper is to discuss approaches to defining and assessing soil quality and to suggest the factors to be considered.

  • PDF

Effects of Steel Fiber Properties on Compressive and Flexural Toughness of Steel Fiber-Reinforced Concrete (강섬유의 특성이 강섬유보강 콘크리트의 압축 및 휨 인성에 미치는 영향)

  • Lim, Dong-Gyun;Jang, Seok-Joon;Jeong, Gwon-Young;Youn, Da-Ae;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.43-50
    • /
    • 2019
  • Effects of tensile strength and aspect ratio of steel fiber on compressive and flexural behavior of steel fiber-reinforced concrete (SFRC) with high- and normal-strength were investigated. Also, this study explores compressive behavior of SFRC with different loading rate. For this purpose, four types of steel fiber were used for SFRC with specified compressive strength of 35 and 60 MPa, respectively. Cylindrical specimens with a diameter of 150 mm and height of 300 mm were made for compression test, and prismatic specimens with a $150{\times}150mm$ cross-section and 450 mm span length were made for flexural test. Test results from compression and flexural tests indicated that the toughness of concrete significant increased with steel fibers. Especially, using steel fiber with high tensile strength and aspect ratio can be lead to performance improvement of high-strength SFRC. In this study, equations are suggested to predict compressive toughness ratio of SFRC from flexural toughness ratio.