• Title/Summary/Keyword: 안장원

Search Result 26, Processing Time 0.017 seconds

Relationship between Lower -Limb Joint Angle and Muscle Activity due to Saddle Height during Cycle Pedaling (사이클 페달링 시 안장높이에 따른 하지관절 각도와 근육활성화의 상관관계)

  • Seo, Jeong-Woo;Choi, Jin-Seung;Kang, Dong-Won;Bae, Jae-Hyuk;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.357-363
    • /
    • 2012
  • The purpose of this study was to investigate the effects of different saddle heights on lower-limb joint angle and muscle activity. Six elite cyclists(age: $32.2{\pm}5.2years$, height: $171.0{\pm}3.5cm$, weight: $79.7{\pm}5.6kg$, cycle career: $13{\pm}6.2years$) participated in three min. submaximal(90 rpm) pedaling tests with the same load and cadence based on saddle heights where subject's saddle height was determined by his knee flexion angle when the pedal crank was at the 6 o'clock position. Joint angles(hip, knee, ankle joints) and the activity of lower limb muscles(biceps femoris(BF), vastus lateralis(VL), tibialis anterior(TA) and gastrocnemius medial(GM)) were compared by measuring 3D motion and electromyography(EMG) data. Results showed that there were significant differences in minimum hip & knee joint angle and range of motion of hip and knee joint between saddle heights. Onset timing and integrated EMG of only BF among 4 muscles were significantly different between saddle heights. Especially there was a negative relationship between minimum hip joint angle and onset timing of BF in most subject, which means that onset timing of BF became fast as the degree of bending of the hip joint became larger by saddle height. Optimal pedaling will be possible through increased amount of muscle activation due to the appropriate burst onset timing by proper pedaling posture with adjusted saddle height.

Botryoid Odontogenic Cyst on Mandibular Anterior and Both Body Area: a Case Report (하악 정중부와 양측 체부에 걸친 botryoid odontogenic cyst: 증례보고 및 문헌고찰)

  • Nam, Jeong-Hun;Kim, Da-Young;Park, Young-Ju;Ahn, Jang-Hoon;Gang, Tae-In;Park, Mi-Hee;Yu, Woo-Geun;Kim, Bo-Gyun;Lee, Jung-Won;Kim, Jung-Hee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.368-372
    • /
    • 2010
  • Botryoid odontogenic cyst (BOC) is considered a rare multilocular variant of the lateral periodontal cyst. In this report, a 67-year-old male visited with chief complaint of severe mobility on mandibular incisors. Multilocular radiolucent lesion was seen from the right premolar to the left premolar area, involving almost the whole mandible. Histologically, the botryoid odontogenic cyst showed focal nodular thickening of the lining epithelium. These thickening often showed swirling appearance of the cells. Cyst enucleation and bone graft on mandible anterior and both body area were performed under general anesthesia, and postoperative healing was favorable without recurrence.

Effects of Increased Saddle Height on Length and Activity Pattern of Vastus Lateralis and Biceps Femor is Muscle (사이클 안장 높이 증가가 대퇴 외측광근과 대퇴이두근의 길이 및 활성화 패턴에 미치는 영향)

  • Choi, Jin-Seung;Kang, Dong-Won;Seo, Jeong-Woo;Bae, Jae-Hyuk;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.4
    • /
    • pp.413-419
    • /
    • 2012
  • The purpose of this study was to investigate the effects of increased saddle height on the length and activity pattern of vastus lateralis (VL) and biceps femoris (BF) muscle. To compare the effects of increased saddle height, Preferred (self-selected height of subject) and High saddle height (approximately 5% higher saddle height than self-selected) were used. Seven elite cyclists (career: $16.1{\pm}8.5years$) participated in 3 min. sub-maximal pedaling tests under the same cadence (90 RPM) and pedaling power (150 W). Hip and knee joint angles, and the length and activity of VL and BF were compared by measuring 3D motion and electromyography (EMG) data. Results showed that there were significant differences in peak extension timing of the hip joint angle and the range of motion of the hip and knee joint between different saddle heights. Although there were significant differences in muscle length of both muscles with increasing saddle height, the timing and amount of muscle activity differed only at the BF. These findings suggest that the timing and amount of bi-articular muscle activity (i.e. BF) can be altered by changing the saddle height. For practically applying these results, further study is necessary to evaluate the effects of various cadence and the pedaling power with various saddle heights.

Saddle Height Determination by Effectiveness of Pedal Reaction Force during Cycle Pedaling (사이클 페달링 시 페달반력 효율성을 고려한 적정 안장높이 결정방법)

  • Bae, Jae-Hyuk;Seo, Jeong-Woo;Kang, Dong-Won;Choi, Jin-Seung;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.417-423
    • /
    • 2014
  • The purpose of this study was to compare two saddle height determination methods by the effectiveness of pedal reaction force. Ten male subjects (age: $24.0{\pm}2.4years$, height: $175.1{\pm}5.4cm$, weight: $69.3{\pm}11.1kg$, inseam: $77.8{\pm}4.5cm$) participated in three minutes, 60 rpm cycle pedaling tests with the same load and cadence. Subject's saddle height was determined by $25^{\circ}$ knee flexion angle (K25) when the pedal crank was at the 6 o'clock position (knee angle method) and 97% (T97), 100% (T100), 103% (T103) of trochanter height (trochanteric method). The RF (resultant force), EF (effective force), and IE (index of effectiveness) were compared by measuring 3D motion and 3-axis pedal reaction force data during 4 pedaling phases (phase1: $330^{\circ}-30^{\circ}$, phase2: $30^{\circ}-150^{\circ}$, phase3: $150^{\circ}-210$, phase4: $210^{\circ}-330^{\circ}$). Results showed that there were significant differences in EF at phase1 between T97 and K25, in EF at phase4 between T100 and T103, in IE at total phase between T97 and K25, between T100 and T103, in IE at phase1 & phase2 between T97 and K25. There was higher IE in the K25 than any other saddle heights, which means that K25 was better pedaling effectiveness than the trochanteric method. Therefore it was suggested the saddle height as 103.7% of trochanter height that converted from K25.

The Effect of Bone Marrow-Derived Osteoblasts on Mandibular Deffect in Rabbit (가토골수에서 유래된 골모세포의 하악골 결손부 이식시 골형성에 미치는 효과)

  • Park, Young-Ju;Nam, Jeong-Hun;Kim, Bo-Gyun;Jeon, Min-Su;Chung, Jae-An;Lee, Jung-Won;Ahn, Jang-Hoon;Gang, Tae-In;Park, Mi-Hee;Lim, Sung-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • Purpose: The purpose of this experiment was to evaluate the clinical effect of cultured autoglogous osteoblasts as a way to treat the defect of mandible in rabbits. Materials and Methods: Twelve rabbits were used to determine the rate of osteogenesis. The osteoblasts were obtained from the iliac crest of rabbits using aspiration. They were then cultured in Dulbecco's Modified Eagles's Medium (DMEM) with beta-glycerophosophatate, L-ascorbicacid, and dexamethasone to proliferate and differentiate osteoprogenitor cells. The expression of osteogenic markers were detected by reverse transcription-polymerase chain reaction (RT-PCR) and silver nitrate staining techniques. Five, 10-mm holes were placed in each rabbit mandible to simulate defective regions with the use of a low speed trephine bur. In the experimental group, the previously cited defects were grafted with both activated osteoblastic and autogenous bone. The control group, however, was only grafted with autogenous bone. Both groups were then analyzed at 2, 4, and 8-week intervals using bone histomorphometric analysis. Results: According to histomorphologic analysis, the rates of new bone formation at the 2, 4, and 8-week intervals were 36%, 51%, and 23% for the control group, respectively; 52%, 39%, and 28%, for the experimental group, respectively. The experimental group showed higher rates of new bone formation compared to the control group at both the 2-week and 8-week interval. Conclusion: Bone marrow-derived osteoblasts seems to be a promising bone graft material.

Study on the radiographic evaluation of marginal bone loss around short-length implant after functional loading (기능적 부하 후 "Short Implant" 주변의 골 흡수에 대한 방사선학적 연구)

  • Park, Young-Ju;Nam, Jeong-Hun;Noh, Kyung-Lok;Yeon, Byoung-Moo;Yu, Woo-Geun;Lee, Jeong-Won;Ahn, Jang-Hun;Gang, Tae-In;Park, Mi-Hee
    • The Journal of the Korean dental association
    • /
    • v.48 no.8
    • /
    • pp.615-620
    • /
    • 2010
  • Purpose: The short dental implant is considered as possible solution in the alveolar bone height deficient cases. The aim of this study was to evaluate clinical availability of short implants by measuring the marginal bone loss of short length implants and comparing with that of conventional length implants. Materials and Methods: The groups were composed of patients who had received at least one implant. The samples of this study were selected from patients who with functional loading after prosthetic treatment for 1 year follow up period. The implants with a length of 5.7 mm and 6mm were considered short. (Bicon Dental implants, USA). The experiment group was composed of $4.5{\times}6mm$, $5{\times}6mm$, $6{\times}5.7mm$ implants (total 18 implants were placed in 14 patients, 8 on maxilla, 10 on mandible). The control group was composed of $4.5{\times}8mm$, $5{\times}8mm$, $4.5{\times}11mm$, $5{\times}11mm$. All implants were selected only by implants placed on molar area. We evaluated marginal bone loss in radiographic images at baseline (implant loading) and 3, 6, 12 months after loading. Additionally, crown-to-implant ratio was evaluated, and marginal bone loss according to crown-to-implant ratio after functional loading was analyzed. Results: The short implant group had a mean marginal bone level of $-0.52{\pm}0.69mm$; the 8mm group, $-0.22{\pm}0.82mm$; and the II mm group, $-0.10{\pm}1.09mm$ after I year of functional loading. But significant differences were not detected between three groups at every follow-up period. Crown-to-implant ratio in short implant group was $1.55{\pm}0.23$; 8mm group was $1.15{\pm}0.18$; and 11mm group was $0.92{\pm}0.15$. Additionally, significant differences between three groups were founded. (P<.0001) The greatest marginal bone loss after 1 year follow-up was founded at crown-to-implant ratio 1~1.49 range in short implant. Conclusion: The marginal bone loss of short implants was comparable to that of long implants. So, the short implants can be a clinically acceptable option.