• Title/Summary/Keyword: 안면

Search Result 7,252, Processing Time 0.039 seconds

Growth and morphological characteristics of Polygonatum species indigenous to Korea (한국산 둥굴레속(Polygonatum) 수집종의 생육 및 형태적 특성)

  • Yun, Jong-Sun;Son, Suk-Yeong;Hong, Eui-Yon;Kim, Ik-Hwan;Yun, Tae;Lee, Cheol-Hee
    • Korean Journal of Plant Resources
    • /
    • v.15 no.2
    • /
    • pp.164-171
    • /
    • 2002
  • Morphological characteristics and growth pattern of 10 Polygonatum collections indigenous to Korea were examined to select the promising medicinal, edible resources and horticultural crops. Plant heights of I0 collections ranged from 15 to 102cm. Stem type was ascending or erect, and node numbers per a stem was 6.2 to 23.2. Phyllotaxis type was alternate or verticillate, and leaf shape was elliptical or linear. Leave numbers per a stem was 5.2 to 63.4, and bract types were classified into bracteate and nonbracteate. Flowers bloomed from May 7 to May 30, and flowering period was 5 to 13 days. Inflorescence types were classified into racemose, corymbose, and umbellate. Flower numbers per a stem was 1.5 to 125.2, and flower length was 13.1 to 30.2㎜. Perianth shapes were classified into tubular, constrict and urceolate. Surface colors of rhizome were pale yellow, pale brown, brown, and dark brown. As a result of this experiment, P. sibiricum, P. odoratum var. pluriflorum and P. odoratum var. thunbergii were thought to be useful as the medicinal and edible resources plants. On the other hand, P. odoratum var. pluriflorum 'Variegata', and P. odoratum var. maximowiczii, P. lasianthum. P. involucratum, P. desoulavyi, P. humile, and P. inflatum were thought to be useful as horticultural plants.

BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY (컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구)

  • Son, Jang-Ho;Choi, Byung-Hwan;Park, Soo-Won;Cho, Yeong-Cheol;Sung, Iel-Yong;Lee, Ji-Ho;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

THE EFFECT OF RESORBABLE MEMBRANE ON BONE REGENERATION IN CALVARIAL DEFECTS OF RATS (백서의 두개골 결손부에서 탈단백우골 이식 시 흡수성악의 효과)

  • Park, Young-Jun;Choi, Guen-Ho;Jang, Jung-Rok;Jung, Seung-Gon;Kim, Young-Joon;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.5
    • /
    • pp.365-374
    • /
    • 2009
  • Purpose : This research evaluates the effect of the use of absorbable membrane barrier with deproteinized bovine bone (Bio-$Oss^{(R)}$, Switzerland) on bone healing in surgically created critical-sized defects in rat calvaria. Materials and Methods : Two standardized transosseous circular calvarial defects (5 mm in diameter) are made in each calvarium of 30 rats. These rats are divided into negative control group(n=15), positive control group(n=15) and two experimental groups(n=15). In the negative control group, defects are only filled with blood clots. In the positive control group, defects are filled with autogenous bone obtained from calvarium; in the experimental group 1, defects are filled with deproteinized bovine bone; and in the experimental group 2, defects are filled with deproteinized bovine bone with absorbable membrane. At the postoperative 1 week, 3 weeks. and 6 weeks, clinical. histologic and histomorphometric evaluations of the defects are performed. Results : 1. The grafted bone without membrane in the calvarial bone defect was scattered but, the grafted bone with membrane was stable. 2. $BioMesh^{(R)}$ membrane was absorbed beginning at 3 weeks, and was absorbed considerably at 6 weeks while maintaining the structural form of the membrane. 3. The use of membrane blocked soft tissue invasion. 4. In histomorphometric analysis. it showed the greatest amount of new bone formation in the positive control group. The amount of new bone formation was greater in the experimental group 2 than experimental group 1. At 6 weeks. the amount of new bone formation was greater in the positive control group than experimental group l(p<0.005). Conclusion : These results suggest that membrane increase the stability of grafted bone and protects from soft tissue invasion, and the use of the membrane may promote new bone formation in deproteinized bovine bone graft area.

A study of mandibular positional changes by the stabilization splint in TMD patients (측두하악장애환자에서 교합안정장치가 하악골위치변화에 미치는 영향에 관한 연구)

  • Cheon, Hun;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.491-507
    • /
    • 2000
  • The purpose of this study was to investigate if there were a significant differences in mandibular position between cephalometric measurements from a centric occlusion tracing compared to those of a acquired centric relation by stabilization splint on malocclusion patient with TMD. 60 malocclusion patients, who had TMD and CO-CR discrepancy beyond normal range, were selected and subdivided into Class I, II, III by Angle's classification and also subdivided into clockwise, straight downward, and counterclockwise group by Jarabak's posterior facial height/anterior facial height ratio. Lateral cephaolmetric radiographs with the mandible in centric occlusion were taken and measured, and for each Patient the stabilization splint with mutually protected occlusal scheme was applied for minimum 3months. After each patient's CO-CR discrepancy was in normal range, lateral cephalometric radiographs were retaken and measured. The comparison of the difference between CO-CR cephalometric measurements in all sample, Class I, II, III groups, and Clockwise, Straight downward, Counterclockwise groups were studied. The finding of this study can be summarized as follows: 1 In all sample, the value of cephalometric measurements was significantly different between CO-CR. The mandible rotated to down and posterior position and the vertical change was greater than the horizontal change (overjet-1.3mm increase, overbite-1.9mm decrease). 2. In Class II malocclusion group, most of the mean difference value between CO-CR is higher than that of the other groups and more measurements was statically significant. 3. In clockwise and counterclockwise group, some of the mean difference value is higher than that of straight downward group and more measurements was statically significant. 4. There ware no measurements that explain centric relation measurements from the type of malocclusion, facial pattern and centric occlusion measurements. Henceforth, it is strongly recommended that stabilization splint therapy for orthodontic treatment on TMD patient should be excuted upon overall facial types prior to orthodontic diagnosis and treatment planning.

  • PDF

Influence of Preferred Chewing Habit on Electromyographic Activity of Masticatory Muscles and Bite Force (편측저작이 저작근의 근활성도와 교합력에 미치는 영향)

  • Yang, Ho-Yeon;Shin, Jun-Han;Choi, Jong-Hoon;Ahn, Hyoung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • As people prefer to use right or left hand, some have preferred chewing side while others do not. Totally, 82 volunteers composed of students and staffs from Dental Hospital College of Dentistry Yonsei University participated in this study for the investigation of influence of preferred chewing habit, that has lasted for more than a year, on electromyographic(EMG) activity of masticatory muscles and bite force. Among the 82 volunteers, 46 had preferred chewing habit while the other 36 did not. Prior to the investigation, those with factors that could affect the study, such as, general disease, irregular dentition and malocclusion, were screened and excluded by questionnaire and clinical examination. The results were as follows: 1. There was no significant difference in EMG activities between chewing side and non-chewing side of preferred chewing subjects at rest as well as maximal voluntary contraction(MCV)(p>0.05). 2. Asymmetrical coefficient of temporal and masseter muscle EMG activities between preferred chewing subjects and non-preferred chewing subjects at rest was not significantly different(p>0.05). 3. Asymmetrical coefficient of masseter EMG activity was significantly higher(p<0.05) than that of non-preferred chewing subjects at MCV, whereas that of anterior temporal muscle showed no difference(p<0.05). 4. In preferred chewing subjects, there was no significant difference in average bite force and occlusal contact area between chewing side and non-chewing side(p>0.05). 5. There was no significant difference in Asymmetrical coefficients of average bite force and occlusal contact area between preferred chewing subjects and non-preferred chewing subjects (p>0.05). Consequently, preferred chewing habit can be considered as physiological asymmetry with normal function rather than to have influence on EMG muscle activity of masticatory muscles, average bite force and occlusal contact area. Objective standardization to differentiate preferred chewing subjects and non-preferred chewing subjects should be established in the further study.

Micro-tensile Bond Strength of Composite Resin Bonded to Er:YAG Laser-prepared Dentin (Er:YAG 레이저로 삭제된 상아질에 대한 컴포지트 레진의 미세인장결합강도에 관한 연구)

  • Min, Suk-Jin;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.211-221
    • /
    • 2006
  • Purpose The aims of this study were to evaluate micro-tensile bond strength of composite resin bonded to dentin following high-speed rotary handpiece preparation or Er:YAG laser preparation with two different adhesive systems and to assess the influence of different Er:YAG laser energies on the micro-tensile bond strength. Materials and Methods In this study, 40 third morlars were used. Flat dentin specimans were obtained and randomly assigned to eight groups. Dentin surfaces were prepared with one of four cutting types: carbide bur, Er:YAG laser (2 W, 3 W and 4 W) and conditioned with two bonding systems, Scotchbond Multipurpose Plus (SM), Clearfil SE bond (SE) and composite resin-build ups were created. After storage for 24 hours, each specimen was serially sectioned perpendicular to the bonded surface to produce more than thirty slabs in each group. Micro-tensile bond strength test was performed at a crosshead speed of 1.0 mm/min. Micro-tensile bond strengths (${\mu}TBS$) were expressed as means$\pm$SD. Data were submitted to statistical analysis using two-way ANOVA, one-way ANOVA, Student-Newman-Keuls' multiple comparison test and t-test. Results and Conclusion 1. Regardless of bonding systems, the ${\mu}TBS$ according to cutting types were from highest to lowest : 3 W, 2 W, Bur, and 4 W. In addition, there was no significant difference between Bur and 4 W (p<0.001). 2. Regardless of cutting types, SM showed significantly higher ${\mu}TBS$ than SE (p<0.001). 3. Bonding to dentin conditioned with SM resulted in higher ${\mu}TBS$ for 3 W compared to Bur, 2 W, and 4 W. There was no significant difference between 2 W and Bur (p<0.001). 4. Bonding to dentin conditioned with SE resulted in higher ${\mu}TBS$ for 3 W compared to 2 W, 4 W, and Bur. Bur exhibited significant lower ${\mu}TBS$ than all other cutting types. There were no significant differences between 3 W, 2 W and between 4 W and Bur (p<0.001). 5. The ${\mu}TBS$ of laser cutting groups were shown in order from highest to lowest: 3 W, 2 W and 4 W in two bonding systems. There was no significant difference between 2 W and 3 W in SE (p<0.001). : The ${\mu}TBS$ of composite resin bonded dentin was significantly affected by interaction between the cutting type and bonding system. In the range of 2 W-3 W, cavity preparation of the Er:YAG laser seems to supply good adhesion of composite resin restoration no less than bur preparation. In particular, if you want to use the self-etching system, including Clearfil SE bond for the purpose of a simplification of the bonding procedures and prevention of adverse effects by excessive etching, an Er:YAG laser may offer better adhesion than a bur.

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

The Evaluation of Bone Scan and SPECT Before and After Treatment of TMD Patients (골관절염을 가진 측두하악장애 환자의 치료 전, 후 골스캔과 SPECT의 평가)

  • Kim, Byeong-Soo;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.57-67
    • /
    • 2005
  • The aim of this study was to evaluate bone scan(SUR) and SPECT(hot spot) in patients with TMJ osteoarthritis. 99mTc-MDP bone scan and SPECT were done in 27 patients, total 54 temporomandibular joints were examined with clinical examination, plain radiography. 42 TMJs were osteoarthritis and 12 TMJs were normal case, clinically diagnosed. We compared osteoarthritis group and control group of bone scan(SUR) and SPECT(hot spot). thus we compared before and after treatment of bone scan(SUR) and bone SPECT(hot spot) according to history, contributing factor, symptom degree, treatment, treatment period. The obtained results were as follows. 1. Bone scan(SUR) and SPECT(hot spot) activity of osteoarthritis group were higher than control group(P<0.05, P<0.01). 2. Bone scan(SUR) and SPECT(hot spot) activity were decreased after treatment at TMJ with osteoarthritis(P<0.01). 3. Bone scan(SUR) and SPECT(hot spot) activity were decreased at treatment group with splint(P<0.01, P<0.05). 4. Bone scan(SUR) and SPECT(hot spot) activity were decreased at Chronic group(P<0.01, P<0.05). 5. Bone scan(SUR) and SPECT(hot spot) activity were decreased at low noise NAS(<6) group(P<0.01,P<0.05). 6. Bone scan(SUR) and SPECT(hot spot) activity were decreased at TMD patient with parafunctional habit and without trauma history, psychosocial factor. 7. Bone scan(SUR) and SPECT(hot spot) activity were higher at before treatment required more treatment period.

Interrelationship of Tension-type Headache and Oral Parafunction (긴장성 두통과 이갈이 습관의 상호관계)

  • Huh, Ki-Hwei;Kim, Jin-Suk;Hong, Jung-Pyo;Chun, Yang-Hyun
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.79-85
    • /
    • 2005
  • This study was designed to confirm the association between the pain of Tension-Type Headache(TTH) patients and their Oral Parafunction(OPF). Patients with TTH(n=58) visited the Department of Oral Medicine, Kyung Hee University Dental Hospital during two months were recruited to this study. 20 patients with OPF(bruxism, clenching, bruxism & clenching) are the experimental group and 38 patients without OPF are the control group. Both groups were asked to answer the questionnaire based on the diagnostic criteria of TTH(IHS). Then it was analyzed statistically. This study was designed to confirm the association between the pain of Tension-Type Headache(TTH) patients and their Oral Parafunction(OPF). Patients with TTH(n=58) visited the Department of Oral Medicine, Kyung Hee University Dental Hospital during two months were recruited to this study. 20 patients with OPF(bruxism, clenching, bruxism & clenching) are the experimental group and 38 patients without OPF are the control group. Both groups were asked to answer the questionnaire based on the diagnostic criteria of TTH(IHS). Then it was analyzed statistically. 1. There was no difference in sex(p=0.91) and age(p=0.73) between two groups. 2. In the experimental group, dull pain was presented more frequently than in the control group. But, there was no difference between two groups(p=0.69). 3. In the experimental group, severe pain was presented more frequently than in the control group. But, there was no difference between two groups(p=0.40). 4. In the experimental group, pain shown bilaterally was presented more frequently than in the control group. But, there was no difference between two groups(p=0.52). 5. In the experimental group, pain was more increased by physical activities than in the control group. But, there was no difference between both groups(p=0.74). The pain of TTH patients with OPF was presented to be non-dull pain frequently and more bilaterally and severely, also increased more by physical activities than the pain of TTH patients without OPF. But, there was no significant difference between two groups. Therefore, it is considered that the pain of TTH is not influenced by OPF.