• Title/Summary/Keyword: 악취저감

Search Result 159, Processing Time 0.034 seconds

A Field Survey on the Odor Concentration in Piggery by the Change of the Season (돈사 내에서 계절별 악취 발생 농도 조사 연구)

  • Kam, D.H.;Jeong, J.W.;Choi, H.C.;Song, J.I.;Hong, J.T.;Lee, D.W.;Yoo, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.187-194
    • /
    • 2007
  • Six pig farms were surveyed to measure the odor concentrations and characteristics of ammonia and sulfide corollary compounds in piggery. They were depended on the scale of piggery, weather conditions such as temperature, humidity, wind speed and direction, scales and types of pig breeding, and manure treatment methods. The highest ammonia concentrations in piggery were measured during the winter, since the tight sealed insulation in piggery made less amount of generated ammonia discharged from piggery. The objective of this study was to measure concentrations of odor in the piggery by season and growing, and to measure concentrations of odor at boundary area. So, we investigated the raising managements, manure managements, and methods of reducing odor according to farm scale. We found that concentration of ammonia gas in the swine fattening piggery in winter was the highest. This result is consistent with the lower ventilation rate to maintain Indoor temperature. In this result, there was no connection between farm scale and ventilating system. Concentration of ammonia gas was 1.64 ppm at one boundary area in the middle scale. $H_2S$, $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ were below the standard of protection odor policy.

  • PDF

Quantification of Odorants from Animal Husbandry using Solid-phase Microextraction (고상(固相) 미세 추출법에 의한 축산 관리시설에서 발생하는 악취성 가스 화합물의 정량적 평가)

  • Kim, Jae-Hyuck;Choi, Hong-Lim;Kown, So-Young;Lim, Hong-Lae;McConnell, Laura L.;Arispe, Susana;Park, Chul-Hwi;Kim, Hyun-Ook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.158-164
    • /
    • 2006
  • Offensive odor from CAFO(concentrated animal feeding operation) and its control have become a significant issue in Korea. Control of odors from the CAFO requires to identify major odorant and their generation mechanisms. In this study, an easy method to collect gas sample and to quantify its odorants is proposed. The method involves on-site odorant extraction with solid-phase microextraction and quantitation with GC/MSD or GC/FID. Analytes of the current study include: trimethylamine(TMA), carbon disulfide($CS_2$), dimethyl sulfide(DMS), dimethyl disulfide(DMDS), acetic acid(AA), propionic acid(PA) and n-butyric acid(BA). The resulting linearity($R^2$) of calibration curve for each analyte was good over the range from several ppbv to ppmv; 0.984 for TMA(0.056-1.437), 0.996 for $CS_2$(0.039-0.999), 0.994 for DMS(0.029-0.756), 0.995 for DMDS(0.024-0.623), 0.992 for AA(0.068-1.314), 0.955 for PA(0.047-0.940), and 0.976 for BA(0.036-0.712). Method detection limits were 5.67, 6.39, 5.78, 25.2, 0.098, 0.363 and 0.099 ppbv for AA, PA, BA, TMA, DMS, $CS_2$, and DMDS, respectively. With the developed method, odorants from poultry, swine, and cattle barns were analysed. All the compounds but DMDS were detected from the sample collected in the poultry barn, and their levels exceeded the representative published human olfactory threshold.

서대구/염색공단에서 발생되는 VOCs오염원별 악취 기여도 평가

  • Lee, Cheol-Gyu;Do, Sang-Hyeon;Choe, Seong-U
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.88-91
    • /
    • 2008
  • 연구대상지역인 서대구/염색공단의 점오염원에서 배출되는 VOC량은 염색공단이 14,834 kg/yr로 전체 배출량의 88.0%를 차지하고 있으며 서대구공단의 점오염원에 비해 7 배이상을 배출하였다. 면오염원의 경우 코일 코팅공정, 건축 및 건물 공정의 도장시설과 금속세정공정이 속한 유기용제사용이 서대구공단과 염색공단에서 VOC 배출량의 약 97%를 차지하고 있다. 서대구/염색공단의 악취를 저감하기 위해서는 면오염원의 발생량기여도가 높은 유기용제사용의 억제와 서대구공단지역의 발생량 감소가 필요하다고 판단이 된다.

  • PDF

Development of Optimal Bio-encapsulated Media for Organic/Inorganic Odor Reduction (유.무기성 악취저감을 위한 최적의 미생물 포괄고정담체 제조법에 관한 연구)

  • Kim, Sun-jin;Kim, Tae-Hyeong;Lee, Yun-Hee;Jang, Hyun-Sup;Song, Ji-Hyeon;Hwan, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • A bio-encapsuled media was developed to apply on reducing odors produced from organic waste treatment process. The microorganism, candida tropicalis, was encapsulated in sponge media consisted of polyurethane material. Sodium alginate as a natural polymer which does not affect to hydrophilic microbes and PEGDA(poly ethylene glycol diacrylate) as a artificial polymer were used for the encapsuled media. The media was evaluated with TMEDA (N,N,N',N'-tetramethylethylenediamine, 0.02~0.1%) as a catalyst at different temperature 25 and $35^{\circ}C$. The best performance was achieved with 0.02% of TMEDA at $25^{\circ}C$. The microbes' activity in the media was examined by Live/Dead cell method.

A Study of Odor Reduction Method for Automatic Waste Collection Facilities (쓰레기자동집하시설의 악취저감대책에 대한 고찰)

  • Paik, Kyung-Il;Um, Jin-Seok;Na, Hyung-Yong;Han, Ihn-Sup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.2
    • /
    • pp.54-58
    • /
    • 2014
  • The method of residential waste and food waste collecting is changed into automatic waste collection(AWC) system from direct collection by human resource. To solve the problem caused by odour from AWC facilities, the structure of input facilities, conveying pipes and collecting facilities have been changed into closed and sealed construction to enclosed the facilities and collect odour efficiently. Based on cases and experiences, to treat variable odour matters which are caused by food waste, chemical cleaning method is preferable method to cope with odour caused by food waste.

A Study on the Removal of Complex Odor including Acetaldehyde and Ozone Over Manganese-based Catalysts (아세트알데히드와 오존 복합악취 저감을 위한 망간기반 촉매 성능 연구)

  • Seo, inhye;Lee, Minseok;Lee, Sooyoung;Cho, Sungsu;Uhm, Sunghyun
    • Applied Chemistry for Engineering
    • /
    • v.28 no.2
    • /
    • pp.193-197
    • /
    • 2017
  • In this study, we report on the catalyst process installed in conjunction with a wet plasma electrostatic precipitator to remove the oil mist and fine dust emitted from large-size grill restaurants. The multi-stage catalyst module reduced odor through catalytic reaction of acetaldehyde on catalysts even at an ambient temperature with ozone as an oxidant readily produced in a wet plasma electrostatic precipitator. Two types of manganese-based catalysts, $Mn_2O_3$ and $CuMnO_x$ were fabricated by extrusion molding for structured catalysts in practical applications, and the optimum conditions for high removal efficiencies of acetaldehyde and ozone were determined. When two optimized catalysts were applied in a two-stage catalyst module, the removal efficiency of acetaldehyde and ozone were ${\geq}85%$ and 100% respectively at the space velocity of $10,000h^{-1}$ and the reaction temperature of $100^{\circ}C$.

Characteristics of Bed Media for Reducing Odor from Livestock Facilities (축사 악취저감을 위한 바이오필터 충전재의 악취제거 특성)

  • 한원석;장동일;방승훈;이승주
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.93-102
    • /
    • 2003
  • This study designed and constructed an experimental column far adhesion efficiency test and conducted experiment to investigate the offensive odor adhesion efficiency of filter bed materials. The offensive odor adhesion experiment was conducted using mixture of high physical adhesion efficiency material, and the fixity of deodorization microorganism of selected filter bed material was tested using ammonia exclude microorganism A4-­2 and sulfur oxidation microorganism S5­-5.2 those were cultured at the Agricultural Chemical Department of Chungnam National University, and deodorization efficiency of selected filter bed material mixture was tested. Following are summary of these tests results. 1. Amount of elimination of the offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.054 and 0.016$\ell/\textrm{cm}^3$ in rice hull, 0.01 and 0.004 $\ell/\textrm{cm}^3$ in rice straw 0.158 and 0.01 $\ell/\textrm{cm}^3$ in coconut, 0.014 and 0.02$\ell/\textrm{cm}^3$ perlite, 0.004 and 0.003$\ell/\textrm{cm}^3$ in high road ball, and 0.112 and 0.015 $\ell/\textrm{cm}^3$ in chaff of pine, respectively. 2. Amount of elimination of offensive odor gas of ammonia and hydrogen sulfide per unit volume was 0.045 and 0.014$\ell/\textrm{cm}^3$ in mixture 1, 0.079 and 0.016$\ell/\textrm{cm}^3$ in mixture 2, 0.123 and 0.017 $\ell/\textrm{cm}^3$ in mixture 3, 0.031 and 0.015$\ell/\textrm{cm}^3$ in mixture 4, 0.055 and 0.016$\ell/\textrm{cm}^3$ in mixture 5, and 0.111 and 0.020$\ell/\textrm{cm}^3$ in mixture 6, respectively. 3. The offensive odor elimination microorganism inoculated to mixture of chaff of pine(70%) and perlite(30%) showed the elimination efficiency of 99.06% and 96.61% against the ammonia and hydrogen sulfide, respectively, during 24 hours period.

  • PDF

Evaluation on the Degree of Satisfaction with Working Environment for Workers Engaged in the Composting Plant with Livestock Manure in the Han-river Watershed (한강유역 축분퇴비공장 근로자의 작업환경 만족도 평가)

  • Kim, K.Y.;Choi, H.L.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.261-270
    • /
    • 2002
  • This study was executed to elucidate the degree of satisfaction with working environment and the factors affecting it for workers who are engaged in the composting plants with livestock manure in the Han-river watershed. As an evaluation on site, we applied the self-administered questionaire including general characteristics, working conditions, degree of satisfaction with working environment, and degree of satisfaction with working condition. Simultaneously, we analysed the exposure levels of odor (ammonia, hydrogen sulfide, and odor intensity) in the boundary area of plants. As a result of the study, health condition, odor, work load, dust, and smoking were proved to be the main factors affecting the degree of satisfaction with working environment for workers who are employed in the composting plants with livestock manure in the Han-river watershed. Of them, it was investigated that health condition, odor, and work load accounted for 61.3% of the total degree of satisfaction with working environment and health condition(p$<$0.01), odor(p$<$0.05), work load(p$<$0.05), and dust(p$<$0.05) were statistically significant. It was concluded that the degree of satisfaction with working environment was high for the workers who had good health status and low for the workers who had the relatively considerable work load and were often exposed to odor and dust. Therefore, to increase the degree of satisfaction with working environment for workers who are engaged in the composting plants with livestock manure, the measures that can reduce the exposure levels of odor and dust emitting from the composting plant with livestock manure should be improved.

Removal of Malodorous Gases Emitted from a Wastewater Pumping Stations by Biological Methods (생물학적 방법에 의한 하수 중계펌프장의 악취제거)

  • 류희욱
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.3
    • /
    • pp.265-270
    • /
    • 2004
  • To select a promising technologies for removal of odorous gases emitted from a wastewater pump station, four methods such as activated carbon (A/C) adsorption, chemical absorption (acid and alkali scrubber), and two biofilters (polyurethane (PU) and worm cast) were investigated. The average odor removal efficiencies in the PU biofilter and A/C column was over 98%, but in a worm cast biofilter and chemical absorption were below 60-80%. The removal efficiency of PU biofilter was very stable (about 98-99%) in the range of retention times of 4-36s, and a maximum elimination capacity was $1.6${\times}$10^{ 7}$ $OUm^{-3}$$h^{-1}$ Deodorization costs for an activated carbon adsorption and a biofiltration method were investigated. With increasing odor intensity, the operating cost of the A/C column increased linearly, but the operating cost of the biofilteration increased slightly. The capital cost in a biofilter is about two times higher than that in an A/C column, but the operating cost is very lower than that of in A/C column. In conclusion, the biofiltration was evaluated one of the most promising technologies to control odor in a wastewater pump station.

Urban Streams' Water Quality and Odor Control Using Pure Oxygen and Vortex Aerator (순산소와 Vortex Aerator를 이용한 도심하천의 수질 및 악취 관리)

  • Yoon, Dain;Choi, Mijeong;Park, Sunghyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2021
  • The target site, Goejeongcheon flows through downtown of Saha-gu, Busan and it connects to the Nakdong-gang estuary. But non-point pollutants and sewage sludge are partially flowing into the stream and deposited. As a result, dissolved oxygen concentrations of the stream were observed close to the anaerobic condition. Multistage Vortex Aerator was applied for restoring this urban stream. It dissolves oxygen by repeatedly causing collisions between water and oxygen by vortex flow. The changes in water quality and odor were monitored for 2 months while circulating 1 m3/min of water with 22 ppm dissolved oxygen. As a result of the operation, the dissolved oxygen was improved from slightly Bad (4)~Bad (5) to Good (1b)~Normal (3) grade, and the total phosphorus concentration was decreased by 76 % on average. In the case of complex odor, a maximum reduction of 84.5 % was observed on the day the entire river was anaerobic. Through this study, we evaluated the feasibility of applying pure oxygen and Vortex Aerator for the the stream restoration. It is expected that the results of this study can be used for full-scale design.