• Title/Summary/Keyword: 악취농도

Search Result 262, Processing Time 0.02 seconds

Investigation on Optimal Aeration Rate for Minimizing Odor Emission during Composting of Poultry Manure with Sawdust (계분톱밥 퇴비화시 악취발생의 최소화를 위한 적정 공기주입을 구명)

  • Kang, Hang-Won;Park, Hyang-Mee;Ko, Jee-Yeon;Lee, Jae-Saeng;Kim, Min-Tae;Kang, Ui-Gum;Lee, Dong-Chang;Moon, Huhn-Pal
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.4
    • /
    • pp.225-231
    • /
    • 2001
  • This study was conducted to find out the optimal aeration rates for minimizing odor emission and for increasing biological activities during composting of livestock manure in the enclosed bench-scale reactor system. It was treated with the mixture of poultry manure and sawdust controlled the initial water content of 60%, then aerated continuously at four different aeration rates (0.1, 0.2, 0.4 and 0.6 L/min/kg dry-solids). The average emitted concentration of ammonia in 0.6 L/min/kg dry-solids during composting reached the level of 40% in comparison with that of 0.2 L/min/kg dry-solids. In cases of sulfur compounds such as hydrogen sulfide, methylmercaptan and ethylmercaptan, their concentrations decreased with increasing aeration rates and the emission time was shortened. But they didn't detect in the treatment of 0.6 L/min/kg dry-solids. The biological activity for composting showed a trend of increasing as aeration rates increased. The treatment of 0.6 L/min/kg dry-solids gave the highest biological activity and the best compost quality.

  • PDF

A Study on the Odor Removal Characteristics of sewage sludge using Bacillus sp. (바실러스균을 이용한 하수 슬러지의 악취 제거 특성에 대한 연구)

  • Sung, Il-Wha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.1-8
    • /
    • 2016
  • This study assessed the feasibility of odor removal by the application of Bacillus sp. that has many advantages in sewage treatment to sewage sludge. The NH3 removal rates in the treatment of primary sludge using only aeration were measured at 24, 48, and 72 hours of treatment and the results were 12.5 %, 12 %, and 42.1 %, respectively. The NH3 removal rates of a reactor injected with BIO-CLOD made by solidifying Bacillus sp. concentrated 10 % together with other substances were measured after 24, 48, and 72 hours of treatment and the results were 43 %, 70 %, and 81 % respectively. In the cases where the Bacillus sp. cultured in NB medium was injected into the primary sludge reactor to reach injection rates of 0 %, 1.7 %, 3.3 %, and 6.7(v/v%), the TVOC removal rates measured when 72 hours had passed after the injection were 59 %, 71 %, 88 %, and 98 % respectively, which were higher than the NH3 removal rates as the NH3 removal rates measured at the same time were shown to be 29 %, 25 %, 31 %, and 48 %, respectively. In the sludge dewaterability conducted with various Bacillus sp. injection concentrations, a Bacillus sp. concentration of 4(v/v%) was considered to be suitable. The Bacillus sp. concentrations and reduction in the bad odor substances were correlated with each other. The results showed that aeration and Bacillus sp. injection will assist biological oxidation so that the bad odor substances can be removed. Based on the SRF values of the primary sludge and digested sludge, in which Alum and PAC were used, the appropriate amount of Alum aggregate reagent was judged to be 500 mg/L, and when PAC was used, 6 mg/L was judged to be appropriate.

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

Conducted to Verify the Effect of Chlorine Dioxide (ClO2) on Odor Reduction at a Commercial Swine Facility (이산화염소 가스분무에 의한 양돈장 악취저감 효과)

  • Song, J.I.;Jeon, J.H.;Park, K.H.;Yoo, Y.H.;Kim, D.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.43-50
    • /
    • 2011
  • This study was conducted to verify the effect of chlorine dioxide ($ClO_2$) on odor reduction at a commercial swine facility consisting of a windowless piglet barn and a grower/fattening barn. The windowless piglet barn used a duct ventilation system. Air velocity at very below the upper duct was 4.53 m/s. Air velocity at the lower space around the living space of pigs in the grower/fattening barn was 0.26 m/s. $NH_3$ concentration was around 9ppm and less than 3 ppm before and after the $ClO_2$ spraying, respectively, which was over 70% reduction. There was no $H_2S$ detection. $NH_3$ concentrations measured in the windowless grower/fattening barn and at the exhausted air were 26 ppm and 11ppm, respectively. $NH_3$ concentration at a biocurtain outside was less than 1 ppm. Hence, $ClO_2$ spraying at windowless barns was effectively decreased malodor such as $NH_3$.

Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House (바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과)

  • Song, J.I.;Choi, H.L.;Choi, H.C.;Kwon, D.J.;Yoo, Y.H.;Jeon, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • Management of odors is essential to swine industry in the Republic of Korea. This study was conducted to evaluate the odor removal efficiency of biofilter ducting systems. Rice straw and auto clave concrete(ALC) were used as filter medium. The ventilation fans(5 units, diameter: 500 mm) at the side wall of a growing pig housing were connected to a biofilter using a duct. The size of a biofilter is $2.5{\times}2{\times}1.2(W{\times}L{\times}H)$. The air velocities at the 300 mm above rice straw and ALC were 0.77 and 0.56 m/s, respectively. Ammonia concentration at the outlet of rice straw and ALC media were 2 and 3 ppm, respectively. Dust concentrations were also measured. The dust concentrations of rice straw and ALC were 93, $32\;mg/m^3$, respectively. There was no significant difference between filter mediums in terms of carbon dioxide concentrations(rice straw: 320, ALC: 270 mg/l). The concentration of hydrogen sulfide was stable over the experimentation. The actual concentrations of hydrogen sulfide were 4, 3 and 3 ppm at the days of 7, 21 and 36, respectively. These results suggest that biofilter ducting systems may remove odors from pig house effectively.

  • PDF

Odorous Gas Removal in Biofilter with Powdered Activated Carbon and Zeolite Coated Polyurethane Foam (분말활성탄 및 제올라이트 담지 폴리우레탄 담체를 이용한 바이오필터에서의 악취가스 제거)

  • Lee, Soo-Chul;Kim, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.209-215
    • /
    • 2012
  • The performance and removal efficiencies of a pilot scale biofilter were estimated by using ammonia and hydrogen sulfide as the odorous gases. Expanded polyurethane foam coated with powdered activated carbon and zeolite was used as a biofilm supporting medium in the biofilter. Odorous gases from the sludge thickener of a municipal wastewater treatment plant were treated in the biofilter for 10 months and the inlet ammonia and hydrogen sulfide concentrations were 0.1-1.5 and 2-20 ppmv, respectively. The removal efficiencies reached about 100% at the empty bed retention time (EBRT) of 3.6-5 seconds except for the adaptation periods. The pressure drop of the biofilter caused by the gas flow was also low that the maximum attained was 31 mm $H_2O$ during the operation. Its stability was confirmed in the long term due to the fact that the biofilter and the polyurethane medium had a minimum plugging and compression. The microbial community on the medium is critical for the performance of the biofilter especially the distribution of ammonia oxidizing bacteria (AOB) and sulfur oxidizing bacteria (SOB). The distribution of Nitrosomonas sp. (AOB) and Thiobacillus ferroxidans (SOB) was confirmed by FISH (fluorescence in situ hybridization) analysis. The longer the operation time, the more microbial population observed. Also, the medium close to the gas inlet had more microbial population than the medium at the gas outlet of the biofilter.

Changes in GC/PFPD Sensitivity in Relation with a Thermal Desorbing Technique for the Analysis of Sulfur Compounds: Comparison of Fixed Standard Concentration(FSC) vs Fixed Standard Volume(FSV) (열탈착 방식을 연계한 GC/PFPD 시스템으로의 주입방식 차에 따른 악취황 성분의 검량특성: 주입부피 대비 주입농도의 고정방식 간 비교연구)

  • Lee, Gi-Han;Kim, Gi-Hyeon
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2007.10a
    • /
    • pp.106-108
    • /
    • 2007
  • PDF

Odor Modeling of acetaldehyde in Gumi National Industrial Complex (구미국가산업단지의 아세트알데히드 악취모델링)

  • Lee, Eun Ju;Akhtar, Muhammad Saeed;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.22-35
    • /
    • 2016
  • In this study CALPUFF modeling was performed to establish a correlation between regions of frequent civil odor complaints near Gumi national industrial complex and odor-emission facilities of synthetic fiber manufacturers in the same area as main acetaldehyde-emission point sources. As a result of the CALPUFF modeling, the maximum concentration of acetaldehyde in Gumi national industrial complex was reduced from O ($10^{-5}g/m^3$) to O ($10^{-6}g/m^3$) upon improving emission facilities of T company so that the maximum concentrations of acetaldehyde frequently appeared in complex 3. In addition, the predicted range of the maximum acetaldehyde concentration in Gumi national industrial complex was also improved in comparison with that prior to improving emission facilities of T company. These maximum concentrations of acetaldehyde obtained to estimate the expected contribution of total acetaldehyde point source by CALPUFF modeling showed the similar values to those measured in 'HAPs investigation in the region of Gumi-Daegu' and were consistent to the trend of civil odor complaints. Therefore, the expected contribution of total acetaldehyde point source was validated. The relative contribution of T company upon improving its emission facilities was predicted to be lowered by more than factor of two, compared to that prior to improving its emission facilities. To the contrary, the relative contribution of W company upon improving emission facilities of T company was predicted to be increased by more than factor of two, compared to that prior to improving emission facilities of T company. This indicates that the contribution of aldehyde point sources of W company was relatively increased upon improving emission facilities of T company.

Characteristics on the Incubation of Sulfur Compound-Oxidizing Strains Separated for the Removal of Malodor (악취제거를 위하여 분리한 황화합물 산화균주의 배양특성)

  • Lim, Dong Joon;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.788-794
    • /
    • 2009
  • Both strains of KD-1212 and DAH-1056 were isolated and identified from animal manure-contaminated soil by screening bacterial strains for the removal of sulfur compound-malodor with such substrate as sodium thiosulfate or free sulfur. Then the characteristics on the incubation of these microbes were observed under various incubating-condition such as pH, temperature, aerobic or anaerobic, substrate(sulfur compound) concentration, nitrogen and carbon source and rotating speed for mixing, and the optimum incubating condition was established. The optimum pHs of KD-1212 and DAH-1056 were 7.0 and 4.0, respectively, and their optimum temperatures were in the range of $30{\sim}35^{\circ}C$. Another autotrophic strain, ED-1138, was isolated from contaminated soil. The strain DAH-1056 excelled a strain Thiobacillus sp. IW in eliminating hydrogen sulfide during the process of malodor-biofiltration with a fixed strain. The characteristics on the incubation of strain KD-1212 were observed under various substrate-concentrations, nitrogen and carbon sources. KD-1212 favored glucose and maltose, and yeast extract as carbon sources and nitrogen source, respectively. The optimum concentrations of substrate and nitrogen source were 25 mM of sodium thiosulfate and 0.5% yeast extract, respectively for the growth of strain KD-1212.

미생물을 이용한 다용도 고형 탈취제의 개발

  • Kim, Yu-Jin;Lee, Eun-Jeong;Jeon, Mi-Uk;Kim, Cho-Hui;Park, Seong-Hun;Lee, Eun-Yeol
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.513-516
    • /
    • 2001
  • This study was to develop of efficient microbial agent for malodor removal. Total ten strains of beneficial bacteria Bacillus sp., Pseudomonas sp., and photosynthetic bacteria were isolated and identified on the basis of their morphological and biochemical characteristics. The enzyme activities such as amylase, protease, lipase and cellulase of bacteria cells were measured. Furthennore, effective formulation procedure 、 ,vas developed with nutrient additive, stabilizing agent and mineral materix. For preparation of microbial agent, developing of formulation technique was very helpful for incresing the cell survival rate.

  • PDF