• Title/Summary/Keyword: 악안면정형재건외과

Search Result 6, Processing Time 0.014 seconds

DENTAL NEWS

  • The Korean Dental Association
    • The Journal of the Korean dental association
    • /
    • v.34 no.11 s.330
    • /
    • pp.831-832
    • /
    • 1996
  • PDF

CONSERVING THE CENTRIC RELATION POSITION OF CONDYLAR HEAD WITH MINI-HOFFMANN SETS IN VERTICAL RAMUS OSTEOTOMY (하악골 수직골절단술시 MINI-HOFFMANN SETS을 이용한 하악 과두의 중심위의 보존)

  • Jeong, Inn-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.95-99
    • /
    • 1991
  • Several authors have proposed techniques and devices by which the correct position of the proximal segment can be maintained both during fixation and postoperatively. Schendel, Epker, Lake, Worms, Ive and Poulton have been discussed the problem of condylar distration in mandibular orthognathic surgery. This study described have showed the some advantages forward repositioning of the condyle head in vertical ramus osteotomy which used with the Mini-Hoffmann sets in external skeletal pin fixation extraorally in 19 cases.

  • PDF

AN EXPERIMENTAL STUDY ON TISSUE REACTIONS OF ALLOGENEIC SCIATIC NERVE GRAFT IN RAT (백서 좌골신경의 동종이식후 조직반응에 관한 실험적 연구)

  • Chung, Hyung-Bai;Yim, Chang-Joon;Lee, Dong-Keun;Se, Jae-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.2
    • /
    • pp.203-216
    • /
    • 1991
  • Nerve allografts as a bridge of regeneration is useful in the repair of peripheral nerve defect resulting from trauma, and leprosy. But immunological rejection and complicated scar formation is an unavoidable problem in the application of allogeneic nerves. This article is intended to study of the regeneration of allogeneic nerve grafts in rats with histopathologically, scanning electron microscopically. 24 adult male Sprague-Dawley rats were used as the experimental animals. A 2cm skin incision was made on the lateral aspects of limb, parallel to femur. Segments of sciatic nerve trunk taken from rats, 10mm was resected at the middle of the thigh, nerve graft was inserted between the ends of gaps with perineural and epineural suture method with 10-0 prolene. Obsrevation was made simultaneously at 3 day, 1, 2, 3, 4, 5, 6, 8 weeks after surgery. The results were as follows. 1. In light and electronic microscopic studies, marked degenerative change of the graft nerves were observed at 2 weeks after surgery. 2. After surgery, blood clot fromation was observed at 3 day, granualtion tissue formation was observed at 2 week, and fibrous tissue proliferation was observed at 3 week. 3. In change of nerve fiber, there were Wallerian degeneration at early stage, decrease in degeneration at 4 week but degeneration of myeline was continuded at 8 week. 4. At 4 week, schwann cells proliferate at its cut ends to join with the distal and proximal stump of the damaged nerve. 5. Fibrous scar tissues are formed at 2 weeks and increased progressively in 8 weeks, which was interrupted the regeneration of grafted nerve.

  • PDF

CASES REPORT OF CLEFT ALVEOLUS REPAIR WITH PMCB GRAFT (치조골 파열환자의 자가망상골 이식을 이용한 치험례)

  • Lee, Dong-Keun;Choi, Seong-Hoon;Chung, Hyung-Bai
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.9-15
    • /
    • 1991
  • The cleft alveolus occurs about 75% of cleft lip and palate patients. The purpose of bone grafting is improve the maxillary growth, rehabilitation of continuty of maxillary arch and providing bone for periodontal support for unerupted teeth. The bone grafting for alveolar cleft defect repair are classsified; primary bone grafting, early secondary bone grafting secondary bone grafting and late secondary bone grafting. In this article, we reported the cases of PMCB grafts for repair of the alveolar clefts showed potential benifit to the patient to induce a normal maxillary growth and providing bone foor periodontal support of unerupted teeth.

  • PDF

Repair of Unilateral Cleft Lip and Nose: Mulliken's Modification of Rotation Advancement (편측 구순열비의 교정술: Rotation Advancement 원칙에 근거한 Mulliken의 방법)

  • Jung, Young-Soo;Lee, Gyu-Tae;Jung, Hwi-Dong;Mulliken, John B.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • This is a review regarding Mulliken's Modification using the Millard rotation-advancement principle for the repair of unilateral complete cleft lip and nasal deformity. All patients underwent prior labionasal adhesion and dentofacial orthopedics with a pin-retained (Latham) appliance used for infants with a cleft of the lip and palate. Technical variations concerning the operation are described. A high rotation and releasing incision in the columella lengthens the medial labial element and produces a symmetric prolabium with minimal transgression of the upper philtral column through the advancement flap. The orbicularis oris muscle is everted, from caudad to cephalad, to form the philtral ridge. A minor variation of unilimb Z-plasty is used to level the cleft side of Cupid's bow handle, and cutaneous closure proceeds superiorly from this junction. The dislocated alar cartilage is visualized though a nostril rim incision and suspended to the ipsilateral upper lateral cartilage. Symmetry of the alar base is addressed in three dimensions, including maneuvers to position the deviated anterior-caudal septum, configure the sill, and efface the lateral vestibular web. The authors believe the technical refinements described herein contribute favorably to the outcome of repair regarding unilateral cleft lip and nasal distortion.

INFLUENCE OF MINIPLATE SHAPES AS SKELETAL ANCHORAGE FOR APPLICATION OF ORTHOPEDIC FORCE: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (악정형력 적용을 위한 골내 고정원으로서 미니플레이트 형상의 영향: 3차원 유한요소법적 연구)

  • Lee, Nam-Ki;Baek, Seung-Hak;Choi, Dong-Soon;Park, Young-Wook;Kim, Ji-Hyuck;Cha, Bong-Kuen
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.4
    • /
    • pp.345-352
    • /
    • 2008
  • Purpose: This study was performed to evaluate the stress distribution in the bone and the displacement distribution of the miniscrew under orthopedic force with two different types of miniplate design as skeletal anchorage for orthopedic treatment. Materials and methods: Finite element models were made for 6-hole miniplate (0.8mm in thickness), which were designed in two different shapes-one is curvilinear shaped (C plate, Jeil Medical Co., Korea) and another, Y shaped (Y plate), fixed with 3 pieces of miniscrew 2mm-diameter and 6mm-long respectively. A traction force of 4 N was applied in $0^{\circ}$, $30^{\circ}$ and $60^{\circ}$ to imaginary axis connecting two unfixed distalmost holes of the miniplate. Results: The maximum von Mises stress in the bone was much greater in the cortical portion rather than in the cancellous portion. C plate showed greater maximum von Mises stress in the cortical bone than Y plate. The maximum displacement of the miniscrew was greater in C plate than Y plate. The more increased the angle of the applied orthopedic force, the greater maximum von Mises stress in the bone and maximum displacement of the miniscrew. It was observed that in C plate, the von Mises stress in the bone and displacement of the miniscrew were distributed around the distalmost screw-fixed area. Conclusions: The results suggest that Y plate should have the advantage over C plate and in the placement of the miniplate, its imaginary axis should be placed as parallel as possible to the direction of orthopedic force to obtain its primary stability.