• Title/Summary/Keyword: 쐐기형

Search Result 203, Processing Time 0.029 seconds

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Choi Dong-Rak;Shin Kyung Hwan;Lee Kyu Chan;Kim Dae Yong;Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyun;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. Materials and Methods : We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60$^{\circ}$) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15cm${\times}$20cm radiation field size at the depth of loom. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15cm H20cm and a polystyrene phantom was used. Results : For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%) , respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5$^{\circ}$ . Suface dose with physical wedge was reduced by maximum 20% (x-ray beam :6 MV, wedge angle:45$^{\circ}$, 550: 80 cm) relative to one with virtual wedge or without wedge. Conclusions : Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge.

  • PDF

Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy (방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.77-88
    • /
    • 1998
  • Wedge shaped isodoses are desired in a number of clinical situations. Hard wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths along with the practical consequendes of filter handling and placement problems. Dynamic wedging uses a combination of a moving collimator and changing monitor dose to achieve angled isodoses. The segmented treatment tables(STT) that monitor unit setting by every distance of moving collimator, was induced by numerical formular. The characteristics of dynamic wedge by STT compared with real dosimetry. Methods and Materials : The accelerator CLINAC 2100C/D at Yonsei Cancer Center has two photon energies (6MV and 10MV), currently with dynamic wedge angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$. The segmented treatment tables(STT) that drive the collimator in concert with a changing monitor unit are unique for field sizes ranging from 4.0cm to 20.0cm in 0.5cm steps. Transmission wedge factors were measured for each STT with an standard ion chamber. Isodose profiles, isodose curves, percentage depth dose for dynamic wedge filters were measured with film dosimetry. Dynamic wedge angle by STT was well coincident with film dosimetry. Percent depth doses were found to be closer to open field but more shallow than hard wedge filter. The wedge transmission factor were decreased by increased the wedge angle and more higher than hard wedge filters. Dynamic wedging probided more consistent gradients across the field compared with hard wedge filters. Dynamic wedging has practical and dosimetric advantages over hard filters for rapid setup and keeping from table collisions. Dynamic wedge filters are positive replacement for hard filters and introduction of dynamic conformal radiotherapy and intensity modulation radiotherapy in a future.

  • PDF

Experimental Investigation on Behaviour of Arrested Saline Wedge (정상 염수쐐기 거동 특성에 대한 실험적 연구)

  • Shin, Hyun-Ho;Lyu, Si-Wan;Kim, Young-Do;Seo, Il-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.874-878
    • /
    • 2007
  • 최근 들어 하구의 이용도가 높아져 감에 따라 용수 취수, 염해 방지공, 하도 계획, 수질 개선 등의 문제와 관련하여 하도 내로 침입하는 염수쐐기를 적절히 제어해야 될 필요성이 대두되고 있다. 이를 위해 염수쐐기의 형태와 거동특성을 정확하게 예측하고 내부유동 구조를 구명하는 것이 필요하다. 염수쐐기의 수리학적 특성에 관한 국내외 연구는 미흡한 실정이다. 국내에서는 하구에서의 유동장 해석을 위한 연구와 염수침입 현상과 반대로 담수 유출이 해양환경에 미치는 영향에 관한 해양공학적 연구가 주로 수행되었다. 국외에서는 1950년대 초반에 하구에서의 염도 혼합양상과 확산계수의 결정 및 수학적 모형에서 각 항들의 상대적 중요성 평가와 같은 기초적인 연구가 수행되었으며, 1970년대에 컴퓨터의 급속한 발전에 힘입어 다양한 수치적 기법이 개발되어 폭이 좁고 성층화된 하구에서의 수치계산이 수행되었다. 본 연구에서는 정상 염수쐐기의 형태 및 거동특성을 파악하기 위하여 수리실험을 수행하였다. 실험은 염수수조, 담수유입부, 수로부로 구성된 실험수로에서 수행되었으며, 염수와 담수간의 밀도차에 근거하여 실험 조건을 설정하였다. 실험을 통하여 밀도차와 담수유입량에 따라 염수쐐기의 형태 및 거동특성이 지배됨을 관찰할 수 있었다.

  • PDF

Osteoporotic Vertebral Fractures: SPECT Findings (골다공증에 동반된 척추골절의 골 SPECT 소견)

  • Baik, Jun-Hyun;Park, Young-Ha;Ihn, Yon-Kwon;Kim, Sung-Hoon;Chung, Yong-An;Yoo, Ie-Ryung;Kim, Jee-Yeung;Jung, Hyun-Seok;Sohn, Hyung-Seon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.522-527
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate the usefulness of single photon emission computed tomography (SPECT) of bone using Tc-99m MDP in the diagnosis of osteoporotic vertebral fractures. Materials and Methods: Thirty two patients with osteoporotic vertebral fracture were included in this study (mean age: $67{\pm}8$, male: 5, female: 27). Seventy nine vertebral fractures were detected (38 thoracic/thoracolumbar lesions and 41 lumbar lesions), which were classified by type of deformity (wedge, biconcave or compression). The patterns and locations of increased uptakes were examined and analyzed. Results: Forty seven wedge fractures, 20 biconcave fractures and 12 compression fractures were found. Diffuse and asymmetric uptakes were common in fractured bodies. More than one uptake were examined in 69 posterior elements of fractured vertebrae (87.3%) including 40 of 47 wedge fractures (85.1%), 17 of 20 biconcave fractures (85.0%) and 12 of 12 compression fractures (100%). Wedge fractures were predominant fracture in thoracic/thoracolumbar spine whereas incidence of biconcave or compression type war similar to that of wedge fracture in lumbar spine (p=0.04). Spinous process uptake was more frequently seen in lumbar lesions than thoracic/thoracolumbar lesions (p=0.009). Facet joint uptake in biconcave fracture was more common in lumbar spine (92.3%) than thoracic/thoracolumbar spine (57.1%). Spinous process uptake in biconcave fracture was also more frequently detected in lumbar spine (p=0.043). Conclusion: Bone SPECT was useful in the evaluation of osteoporotic vertebral fracture, especially posterior elements of vertebrae.

An Analysis of Design Parameters and Optimal Design for Anchors with Wide CFRP Plate (대형 CFRP Plate용 정착구의 설계요소분석 및 최적설계)

  • Kim, Hyung-Joon;Chung, Heung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.102-112
    • /
    • 2020
  • In this study, in order to design a wedge-type anchor that can hold an wide carbon plate with a width of 100 mm or more that can be used in a bridge structure, the mechanical behaviors are evaluated based on the main design variables such as the angle of the wedge and the coefficient of friction between the guide and the wedge. The stress state of the carbon plate was calculated by numerical analysis method for each design variable, and the performance of the anchor in the critical state was evaluated according to the failure criteria for composite material, and the optimal design specifications of the anchor were determined based on numerical results. The performance of the optimally designed anchor was verified through actual experiments, and the results of this study are considered to be useful for the optimal design of the CFRP plate anchor to reinforce large structures.

Natural Convection Within a Wedge-Shaped Enclosure (쐐기형 밀폐 공간 내에서의 자연 대류 열전달)

  • Bae, T.Y.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.259-266
    • /
    • 1994
  • Natural convection within a wedge-shaped enclosure has been studied numerically by finite difference method. Radial surfaces of the wedge are isothermally hot and cold while circumferential surfaces are insulated. Results show isotherms, streamlines and velocity profiles as well as Nusselt number distributions for a Rayleigh number range of $10^3$ to $10^5$. In addition, it is found that there is a wedge angle as shown the minimum mean Nusselt number for using an insulated enclosure.

  • PDF

Manufacturing of Wedge-type Light Guide Plates for Large Liquid Crystal Displays (대형 LCD용 쐐기형 도광판 제조공정에 대한 연구)

  • Kim, Min-Soo;Kim, Jangseob;Hong, Jun-Ho;Shin, Dongwon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.4
    • /
    • pp.30-35
    • /
    • 2020
  • The light guide plate (LGP) provides a surface light source on the back of the liquid crystal display (LCD), which is not self-emitting; thus, it is an essential component of display units requiring sufficient brightness. To maximize the light-emitting effect of an LGP, enough incident light, from the light source, should enter into its side. However, the current trend in LCD panels is represented by larger and thinner screens and this smaller thickness prevents the accordingly thin LGPs from providing sufficient brightness. This paper proposes a process for manufacturing wedge-type LGPs, which might increase the amount of incident light and, consequently the surface light emission, for applications in large LCDs. The proposed method was validated by building a dedicated manufacturing machine and performing illuminance experiments on the fabricated LGP.